Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Line positions and intensities for the gamma 1 + gamma 2 and gamma 2 + gamma 3 bands of (16)O3

Using 0.005 cm-resolution Fourier transform spectra of (16)O3, generated by electric discharge from a greater than 99.98 percent pure sample of (16)O3, an extensive analysis of the gamma 1 + gamma 2 and the gamma 2 + gamma 3 bands in the 5.7 micron region was performed. The rotational energy levels of the upper (110) and (011) vibrational states of (16)O3 were reproduced within their experimental uncertainties using a Hamiltonian which takes explicitly into account the Coriolis-type interaction occurring between the rotational energy levels of both states. Improved vibrational energies and rotational and coupling constants were also derived for the (110) and (011) states. Precise transition moment constants for these two bands were deduced from analysis of 220 measured line intensities. Finally, a complete list of line positions, intensities, and lower state energies for both bands has been generated.

Devi, V. Malathy↗

Determination and characterization of the Hubble Space Telescope pointing stability

The Hubble Space Telescope (HST) was designed to maintian a pointing stability (jitter) of 0.007 arc seconds rms throughout every observing period, which can last from a few seconds to several orbits. On-orbit measurements indicate that the hardware excitation induced by the reaction wheels. gyros, high gain antennae, science instrument mechanisms and tape recorders are well within specifications. Unexpectedly, the solar arrays because the dominant source of jitter. Every passage through an orbital terminator produces vibrations which emanate from the solar arrays due to thermal effects, which affect the relative positional stability. Broadband frequencies centered about 0.11 and 0.65 Hz were detected in the frequency content of the vehicle jitter. On-board modifications to the control law have attenuated the disturbance torques and reduced the vehicle jitter close to specification. Replacement of the solar arrays in December, 1993, should eliminate the torque distubances. Astrometric science observations are extremely susceptible to corruption from vehicle jitter. The removal of vehicle jitter from astrometric Transfer function scans of binary stars is explained in detail. A binary star separation of 16 milli-seconds of arc has been achieved, a separation resolution of 10 to 12 milli-seconds of arc appears feasible, with a binary star magnitude of 9 m(sub V). The achievement of this resolution is in part due to vehicle jitter removal. Comparison of vehicle jitter measurements from the position path of the vehicle control law, or from the guiding Fine Guidance Sensors (FGS), are shown to be equivalent to approximately 0.001 arc second.

Bradley, A. J.↗

Regional CO2 and latent heat surface fluxes in the Southern Great Plains: Measurements, modeling, and scaling

Characterizing net ecosystem exchanges (NEE) of CO{sub 2} and sensible and latent heat fluxes in heterogeneous landscapes is difficult, yet critical given expected changes in climate and land use. We report here a measurement and modeling study designed to improve our understanding of surface to atmosphere gas exchanges under very heterogeneous land cover in the mostly agricultural U.S. Southern Great Plains (SGP). We combined three years of site-level, eddy covariance measurements in several of the dominant land cover types with regional-scale climate data from the distributed Mesonet stations and Next Generation Weather Radar precipitation measurements to calibrate a land surface model of trace gas and energy exchanges (isotope-enabled land surface model (ISOLSM)). Yearly variations in vegetation cover distributions were estimated from Moderate Resolution Imaging Spectroradiometer normalized difference vegetation index and compared to regional and subregional vegetation cover type estimates from the U.S. Department of Agriculture census. We first applied ISOLSM at a 250 m spatial scale to account for vegetation cover type and leaf area variations that occur on hundred meter scales. Because of computational constraints, we developed a subsampling scheme within 10 km 'macrocells' to perform these high-resolution simulations. We estimate that the Atmospheric Radiation Measurement Climate Research Facility SGP region net CO{sub 2} exchange with the local atmosphere was -240, -340, and -270 gC m{sup -2} yr{sup -1} (positive toward the atmosphere) in 2003, 2004, and 2005, respectively, with large seasonal variations. We also performed simulations using two scaling approaches at resolutions of 10, 30, 60, and 90 km. The scaling approach applied in current land surface models led to regional NEE biases of up to 50 and 20% in weekly and annual estimates, respectively. An important factor in causing these biases was the complex leaf area index (LAI) distribution within cover types. Biases in predicted weekly average regional latent heat fluxes were smaller than for NEE, but larger than for either ecosystem respiration or assimilation alone. However, spatial and diurnal variations of hundreds of W m{sup -2} in latent heat fluxes were common. We conclude that, in this heterogeneous system, characterizing vegetation cover type and LAI at the scale of spatial variation are necessary for accurate estimates of bottom-up, regional NEE and surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Rapid nondestructive measurement of bacterial cultures with 3D interferometric imaging

The agar culture plate has played a crucial role in bacteriology since the origins of the discipline. However, plating, inoculating, and waiting for microbes to develop colonies that are visible is time-consuming. In this work, we explored if white-light interferometry (WLI) would be a practical tool for reducing the wait time required before colonies can be identified and counted. High resolution surface profile imaging was used for non-destructive characterization and counting of bacterial colonies on agar before they became visible to the naked eye. The three-dimensional (3D) morphology of Gram-negative ( Pseudomonas fluorescens ) and Gram-positive ( Bacillus thuringiensis ) bacterial species were visualized over time by collecting surface profiles of colonies on agar plates with high vertical resolution (3-5 nanometers) and large field of view (3-5 mm). This unique combination of sensitive vertical resolution at low magnification enabled simultaneous detection of hundreds of microcolonies. The colonies were accurately counted within the first few hours after plating with results comparing favorably to counts made by traditional methods. Since the imaging is non-destructive it was used to track single cells multiplying into small colonies and the volumetric changes in the colony were used to accurately measure colony growth rates over time. Based on the results herein, bioimaging with WLI was demonstrated as a powerful bacterial culture assay. Fast non-destructive counting of colony-forming units in a culture and simultaneous measurement of bacterial growth rates with this method suggest that it may lead to beneficial future applications in research, clinical, and other settings.

59 BASIC BIOLOGICAL SCIENCES↗

A soft x-ray beamline capable of canceling the performance impairment due to power absorbed on its optical elements

We present an entrance slitless beamline design capable of maintaining its very high performance in terms of energy resolution (>10{sup 4}) and spot size (4x4 {mu}m{sup 2}) at the sample position despite being exposed to more than 2.15 kW of undulator radiation and a maximum power density on the optics of more than 0.9 W/mm{sup 2}. Ray tracing simulations of this beamline under the worst-case thermal deformations of the optical element surfaces verify that appropriate focusing corrections are able to cancel the deleterious effects of these deformations. One of the necessary conditions for this cancellation is to illuminate the optical elements with a larger solid angle than the undulator's central cone, which contains the usable photons but is considerably smaller than the angular power distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Catalysis-dependent selenium incorporation and migration in the nitrogenase active site iron-molybdenum cofactor

Dinitrogen reduction in the biological nitrogen cycle is catalyzed by nitrogenase, a two-component metalloenzyme. Understanding of the transformation of the inert resting state of the active site FeMo-cofactor into an activated state capable of reducing dinitrogen remains elusive. Here we report the catalysis dependent, site-selective incorporation of selenium into the FeMo-cofactor from selenocyanate as a newly identified substrate and inhibitor. The 1.60 Å resolution structure reveals selenium occupying the S2B site of FeMo-cofactor in the Azotobacter vinelandii MoFe-protein, a position that was recently identified as the CO-binding site. The Se2B-labeled enzyme retains substrate reduction activity and marks the starting point for a crystallographic pulse-chase experiment of the active site during turnover. Through a series of crystal structures obtained at resolutions of 1.32–1.66 Å, including the CO-inhibited form of Av1-Se2B, the exchangeability of all three belt-sulfur sites is demonstrated, providing direct insights into unforeseen rearrangements of the metal center during catalysis.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral measurements of runaway electrons by a scanning probe in the TEXTOR tokamak

Energy spectral measurements of runaway electrons were performed by a scanning probe with high spatial and temporal resolution in the TEXTOR tokamak. The probe consists of ten YSO (Y{sub 2}SiO{sub 5}:Ce) crystals, which are shielded by tungsten filters. The probe can resolve electrons with different energies between 4 and 30 MeV. An insertion of the probe to the plasma boundary several times during the discharge allowed spectral measurements of runaway electrons at different minor radial positions at the plasma edge as well as the study of runaway production in time. The high temporal resolution of the probe, 0.05 ms, enabled measurements of runaway electrons not only during low density discharges, but also during plasma disruptions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functional Flight Test Report for Positive Systems' ADAR System 5500 Sensor SN8 Linear

This report describes results of the functional flight test conducted with the Positive Systems' ADAR 5500 sensor system (serial number 8, linear configuration) near Winslow, Arizona on June 30 and July 1, 1999. The in-flight test is one component of the NASA Scientific Data Purchase (SDP) Validation and Verification (V&V) process. It allows to measure characteristics of the entire sensor system affected by both performance of the sensor during a flight and post-flight image processing. The following characteristics were analyzed: changes of dark digital numbers (DN's), radiometric linearity, signal-to-noise ratio (SNR), spatial resolution, and geolocation accuracy. The measured characteristics were compared with the image product specifications defined in the Positive Systems' SDP contract. Dependence of the dark DN's on several factors was analyzed, but no significant correlation was found. However, the observed changes in dark DN's were relatively small, which justifies usage of a constant value in the dark DN subtraction procedure during post-processing. Dependence of measured at-sensor, in-band radiance (in arbitrary units) on measured in-band ground reflectance is very well described by a linear function - The sensor fulfills the linearity requirement. Measured SNR values lower than the contract specifications, but accuracy of that test was possibly affected by non-uniformity of the employed gray-scale panels. The SNR values are generally sufficiently high for most applications. SNR can also be improved during standard flights by using longer exposure times. Full width at half maximum (FWHM) of an edge response derived line spread function was used as a measure of spatial resolution. FWHM was generally smaller than twice the ground sample distance (GSD), in agreement with the contract specifications. Accuracy of the geolocation information, which is provided for the particular images in a metadata file, was found to meet contract requirements as well.

Stanley, Tom↗

Time Resolution of Fast Photomultipliers for Time of Flight PET

Time resolution study of 1 inch Photonis XP1020 photomultiplier is reported. The number of photoelectrons, time jitter and time resolution with 4x4x20 mm{sup 3} LSO crystal were measured. All the mentioned PMT properties were measured at five positions on the photocathode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BREAKDOWN OF KENNICUTT-SCHMIDT LAW AT GIANT MOLECULAR CLOUD SCALES IN M33

We have mapped the northern area (30' x 20') of a Local Group spiral galaxy M33 in {sup 12}CO(J = 1-0) line with the 45 m telescope at the Nobeyama Radio Observatory. Along with H{alpha} and Spitzer 24 {mu}m data, we have investigated the relationship between the surface density of molecular gas mass and that of star formation rate (SFR) in an external galaxy (Kennicutt-Schmidt law) with the highest spatial resolution ({approx}80 pc) to date, which is comparable to scales of giant molecular clouds (GMCs). At positions where CO is significantly detected, the SFR surface density exhibits a wide range of over four orders of magnitude, from {Sigma}{sub SFR} {approx_lt} 10{sup -10} to {approx}10{sup -6} M {sub sun} yr{sup -1} pc{sup -2}, whereas the {Sigma}{sub H{sub 2}} values are mostly within 10-40 M {sub sun} pc{sup -2}. The surface density of gas and that of SFR correlate well at an {approx}1 kpc resolution, but the correlation becomes looser with higher resolution and breaks down at GMC scales. The scatter of the {Sigma}{sub SFR}-{Sigma}{sub H{sub 2}} relationship in the {approx}80 pc resolution results from the variety of star-forming activity among GMCs, which is attributed to the various evolutionary stages of GMCs and to the drift of young clusters from their parent GMCs. This result shows that the Kennicutt-Schmidt law is valid only in scales larger than that of GMCs, when we average the spatial offset between GMCs and star-forming regions, and their various evolutionary stages.

79 ASTRONOMY AND ASTROPHYSICS↗

Extreme ultraviolet spectrograph ATM experiment S082B

The extreme-ultraviolet double-dispersion photographic spectrograph for the Apollo Telescope Mount (ATM) experiment S082B on Skylab is described. Novel features were the use of a predisperser grating with a ruling whose spacing varied approximately linearly with distance for the purpose of increasing the instrument speed by reducing the astigmatism and a photoelectric servosystem to stabilize to 1 sec of arc the solar image at various near-limb positions. The 970-3940-A range was covered in two sections with effective resolving power of approximately 30,000 from 1100 A to 1970 A. The spatial resolution was 2 x 60 solar sec of arc. During the Skylab mission 6400 exposures were made with the instrument pointed by an astronaut at selected and recorded solar positions.

Bartoe, J.-D. F.↗

Satellite image analysis for surveillance, vegetation and climate change

Recently, many studies have provided abundant evidence to show the trend of tree mortality is increasing in many regions, and the cause of tree mortality is associated with drought, insect outbreak, or fire. Unfortunately, there is no current capability available to monitor vegetation changes, and correlate and predict tree mortality with CO{sub 2} change, and climate change on the global scale. Different survey platforms (methods) have been used for forest management. Typical ground-based forest surveys measure tree stem diameter, species, and alive or dead. The measurements are low-tech and time consuming, but the sample sizes are large, running into millions of trees, covering large areas, and spanning many years. These field surveys provide powerful ground validation for other survey methods such as photo survey, helicopter GPS survey, and aerial overview survey. The satellite imagery has much larger coverage. It is easier to tile the different images together, and more important, the spatial resolution has been improved such that close to or even higher than aerial survey platforms. Today, the remote sensing satellite data have reached sub-meter spatial resolution for panchromatic channels (IKONOS 2: 1 m; Quickbird-2: 0.61 m; Worldview-2: 0.5 m) and meter spatial resolution for multi-spectral channels (IKONOS 2: 4 meter; Quickbird-2: 2.44 m; Worldview-2: 2 m). Therefore, high resolution satellite imagery can allow foresters to discern individual trees. This vital information should allow us to quantify physiological states of trees, e.g. healthy or dead, shape and size of tree crowns, as well as species and functional compositions of trees. This is a powerful data resource, however, due to the vast amount of the data collected daily, it is impossible for human analysts to review the imagery in detail to identify the vital biodiversity information. Thus, in this talk, we will discuss the opportunities and challenges to use high resolution satellite imagery and machine learning theory to monitor tree mortality at the level of individual trees.

47 OTHER INSTRUMENTATION↗

Use of the BrainLAB ExacTrac X-Ray 6D System in Image-Guided Radiotherapy

The ExacTrac X-Ray 6D image-guided radiotherapy (IGRT) system will be described and its performance evaluated. The system is mainly an integration of 2 subsystems: (1) an infrared (IR)-based optical positioning system (ExacTrac) and (2) a radiographic kV x-ray imaging system (X-Ray 6D). The infrared system consists of 2 IR cameras, which are used to monitor reflective body markers placed on the patient's skin to assist in patient initial setup, and an IR reflective reference star, which is attached to the treatment couch and can assist in couch movement with spatial resolution to better than 0.3 mm. The radiographic kV devices consist of 2 oblique x-ray imagers to obtain high-quality radiographs for patient position verification and adjustment. The position verification is made by fusing the radiographs with the simulation CT images using either 3 degree-of-freedom (3D) or 6 degree-of-freedom (6D) fusion algorithms. The position adjustment is performed using the infrared system according to the verification results. The reliability of the fusion algorithm will be described based on phantom and patient studies. The results indicated that the 6D fusion method is better compared to the 3D method if there are rotational deviations between the simulation and setup positions. Recently, the system has been augmented with the capabilities for image-guided positioning of targets in motion due to respiration and for gated treatment of those targets. The infrared markers provide a respiratory signal for tracking and gating of the treatment beam, with the x-ray system providing periodic confirmation of patient position relative to the gating window throughout the duration of the gated delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

MULTI-COMPONENT ANALYSIS OF POSITION-VELOCITY CUBES OF THE HH 34 JET

We present an analysis of H{alpha} spectra of the HH 34 jet with two-dimensional spectral resolution. We carry out multi-Gaussian fits to the spatially resolved line profiles and derive maps of the intensity, radial velocity, and velocity width of each of the components. We find that close to the outflow source we have three components: a high (negative) radial velocity component with a well-collimated, jet-like morphology; an intermediate velocity component with a broader morphology; and a positive radial velocity component with a non-collimated morphology and large linewidth. We suggest that this positive velocity component is associated with jet emission scattered in stationary dust present in the circumstellar environment. Farther away from the outflow source, we find only two components (a high, negative radial velocity component, which has a narrower spatial distribution than an intermediate velocity component). The fitting procedure was carried out with the new AGA-V1 code, which is available online and is described in detail in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Studying the Role of a Single Mutation of a Family 11 Glycoside Hydrolase Using High-Resolution X-ray Crystallography

XynII is a family 11 glycoside hydrolase that uses the retaining mechanism for catalysis. In the active site, E177 works as the acid/base and E86 works as the nucleophile. Mutating an uncharged residue (N44) to an acidic residue (D) near E177 decreases the enzyme’s optimal pH by ~ 1.0 unit. D44 was previously suggested to be a second proton carrier for catalysis. To test this hypothesis, we abolished the activity of E177 by mutating it to be Q, and mutated N44 to be D or E. These double mutants have dramatically decreased activities. Our high-resolution crystallographic structures and the microscopic pK a calculations show that D44 has similar position and pK a value during catalysis, indicating that D44 changes electrostatics around E177, which makes it prone to rotate as the acid/base in acidic conditions, thus decreases the pH optimum. Our results could be helpful to design enzymes with different pH optimum.

59 BASIC BIOLOGICAL SCIENCES↗

Resolving the Chemically Discrete Structure of Synthetic Borophene Polymorphs

Atomically thin two-dimensional (2D) materials exhibit superlative properties dictated by their intralayer atomic structure, which is typically derived from a limited number of thermodynamically stable bulk layered crystals (e.g., graphene from graphite). The growth of entirely synthetic 2D crystals, those with no corresponding bulk allotrope, would circumvent this dependence upon bulk thermodynamics and substantially expand the phase space available for structure-property engineering of 2D materials. However, it remains unclear if synthetic 2D materials can exist as structurally and chemically distinct layers anchored by van der Waals (vdW) forces, as opposed to strongly bound adlayers. Here, we show that atomically thin sheets of boron (i.e., borophene) grown on the Ag(111) surface exhibit a vdW-like structure without a corresponding bulk allotrope. Using X-ray standing wave-excited X-ray photoelectron spectroscopy, the positions of boron in multiple chemical states are resolved with sub-angstrom spatial resolution, revealing that the borophene forms a single planar layer that is 2.4 angstrom above the unreconstructed Ag surface. Moreover, our results reveal that multiple borophene phases exhibit these characteristics, denoting a unique form of polymorphism consistent with recent predictions. Furthermore, this observation of synthetic borophene as chemically discrete from the growth substrate suggests that it is possible to engineer a much wider variety of 2D materials than those accessible through bulk layered crystal structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal structure of Cu2Zn(GexSi1−x)Se4 solid solution: the kesterite to wurtz–kesterite structural phase transition

Developing low-cost, sustainable, and environmentally friendly top absorber layers for tandem solar cells is essential to advancing photovoltaic technologies and accelerating the transition to renewable energy. In this work, we explore the potential of tetravalent (Cu2Zn(GexSi1−x)Se4) cation mutations in chalcogenide compound semiconductors with the aim of finding a material with increased band gap and reduced structural disorder. A combination of high-resolution synchrotron powder diffraction and neutron powder diffraction was used to determine the atomic positions and monoclinic angles in monoclinic wurtz–kesterite type Cu2Zn(GexSi1−x)Se4 mixed crystals as well as to determine the cation distribution in the crystal structure of Ge-rich kesterite-type and Si-rich wurtz–kesterite type mixed crystals. These investigations enabled us to deduce the structural transition scenario within the Cu2Zn(GexSi1−x)Se4 series. The transition occurs via a region where two phases with different crystal structures, tetragonal and monoclinic and thus a different distortion of the coordination tetrahedra, but the same cation distribution within the element specific cation sites co-exist. Thus, the structural transition between the kesterite and the wurtz–kesterite structure within the Cu2Zn(GexSi1−x)Se4 series is a distortion driven transition. The study identifies cation mutation in quaternary chalcogenides as a promising strategy beyond chalcopyrites and kesterites for low cost and environmentally friendly top absorbers in tandem solar cells.

Gurieva, Galina [Helmholtz Center Berlin for Mater↗