Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantum efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

SU-C-304-05: Use of Local Noise Power Spectrum and Wavelets in Comprehensive EPID Quality Assurance

Purpose: As EPIDs are increasingly used for IMRT QA and real-time treatment verification, comprehensive quality assurance (QA) of EPIDs becomes critical. Current QA with phantoms such as the Las Vegas and PIPSpro™ can fail in the early detection of EPID artifacts. Beyond image quality assessment, we propose a quantitative methodology using local noise power spectrum (NPS) to characterize image noise and wavelet transform to identify bad pixels and inter-subpanel flat-fielding artifacts. Methods: A total of 93 image sets including bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Quantitative metrics such as modulation transform function (MTF), NPS and detective quantum efficiency (DQE) were computed for each image set. Local 2D NPS was calculated for each subpanel. A 1D NPS was obtained by radial averaging the 2D NPS and fitted to a power-law function. R-square and slope of the linear regression analysis were used for panel performance assessment. Haar wavelet transformation was employed to identify pixel defects and non-uniform gain correction across subpanels. Results: Overall image quality was assessed with DQE based on empirically derived area under curve (AUC) thresholds. Using linear regression analysis of 1D NPS, panels with acceptable flat fielding were indicated by r-square between 0.8 and 1, and slopes of −0.4 to −0.7. However, for panels requiring flat fielding recalibration, r-square values less than 0.8 and slopes from +0.2 to −0.4 were observed. The wavelet transform successfully identified pixel defects and inter-subpanel flat fielding artifacts. Standard QA with the Las Vegas and PIPSpro phantoms failed to detect these artifacts. Conclusion: The proposed QA methodology is promising for the early detection of imaging and dosimetric artifacts of EPIDs. Local NPS can accurately characterize the noise level within each subpanel, while the wavelet transforms can detect bad pixels and inter-subpanel flat fielding artifacts.

60 APPLIED LIFE SCIENCES↗

Avalanche photodiode based detector for beam emission spectroscopy

An avalanche photodiode based (APD) detector for the visible wavelength range was developed for low light level, high frequency beam emission spectroscopy (BES) experiments in fusion plasmas. This solid state detector has higher quantum efficiency than photomultiplier tubes, and unlike normal photodiodes, it has internal gain. This paper describes the developed detector as well as the noise model of the electronic circuit. By understanding the noise sources and the amplification process, the optimal amplifier and APD reverse voltage setting can be determined, where the signal-to-noise ratio is the highest for a given photon flux. The calculations are compared to the absolute calibration results of the implemented circuit. It was found that for a certain photon flux range, relevant for BES measurements ({approx_equal}10{sup 8}-10{sup 10} photons/s), the new detector is superior to both photomultipliers and photodiodes, although it does not require cryogenic cooling of any component. The position of this photon flux window sensitively depends on the parameters of the actual experimental implementation (desired bandwidth, detector size, etc.) Several detector units based on these developments have been built and installed in various tokamaks. Some illustrative results are presented from the 8-channel trial BES system installed at Mega-Ampere Spherical Tokamak (MAST) and the 16-channel BES system installed at the Torus Experiment for Technology Oriented Research (TEXTOR).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Cs 3 Sb photocathodes at cryogenic temperatures

Here, we report measurements of quantum efficiency (QE) and mean transverse energy (MTE) from Cs 3 Sb photocathodes in a wide range of photon energies at both room and cryogenic temperatures. Our measurements show a strong temperature dependence of MTE even at photon energies well above threshold, indicating the presence of strong inelastic scattering of excited electrons during transport before emission into vacuum. We also demonstrate a cathode cooling method that largely preserves the QE while reducing MTE, allowing us to achieve MTEs as low as 58 meV with 3% QE in green light from Cs 3 Sb photocathodes. Our results are crucial for producing brighter electron beams for various photoinjector applications like ultrafast electron diffraction and microscopy, x-ray free-electron lasers, and particle colliders.

36 MATERIALS SCIENCE↗

Performance characterization of a MVCT scanner using multislice thick, segmented cadmium tungstate-photodiode detectors

Purpose: Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography (MVCBCT) can be used for visualizing anatomical structures prior to radiation therapy treatments to assist in patient setup and target localization. These systems are less susceptible to metal artifacts and provide better CT number linearity than conventional CT scanners. However, their contrast is limited by the properties of the megavoltage photons and the low detective quantum efficiency (DQE) of flat panel detector systems currently available. By using higher DQE, thick, segmented cadmium tungstate detectors, the authors can improve the low contrast detectability of a MVCT system. This in turn would permit greater soft tissue visualization for a given radiation dose, allowing MVCT to be used in more clinical situations. Methods: This article describes the evaluation of our prototype system that uses thick, segmented detectors. In order to create images using a dose that would be acceptable for day to day patient imaging, the authors evaluated their system using the low intensity bremsstrahlung component of a 6 MeV electron beam. The system was evaluated for its uniformity, high contrast resolution, low contrast detectability, signal to noise ratio, contrast to noise ratio, and CT number linearity. Results: The prototype system was found to have a high contrast spatial resolution of about 5 line pairs per cm, and to be able to visualize a 15 mm 1.5% contrast target with 2 cGy of radiation dose delivered. SNR{sup 2} vs radiation dose and mean pixel value vs electron density curves were linear. Conclusions: This prototype system shows a large improvement in low contrast detectability over current MVCBCT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R&D ERL: Photocathode Deposition and Transport System

The purpose of the photocathode deposition and transport system is to (1) produce a robust, high yield multialkali photocathode and (2) have a method of transporting the multialkali photocathode for insertion into a super conducting RF electron gun. This process is only successful if a sufficient quantum efficiency lifetime of the cathode, which is inserted in the SRF electron gun, is maintained. One important element in producing a multialkali photocathode is the strict vacuum requirements of 10{sup -11} torr to assure success in the production of longlived photocathodes that will not have their QE or lifetime depleted due to residual gas poisoning in a poor vacuum. A cutaway view of our third generation deposition system is shown in figure 1. There are certain design criteria and principles required. One must be able to install, remove, rejuvenate and replace a cathode without exposing the source or cathode to atmosphere. The system must allow one to deposit Cs, K, and Sb on a cathode tip surface at pressures in the 10{sup -10} to 10{sup -9} torr range. The cathode needs to be heated to as high as 850 C for cleaning and maintained at 130 C to 150 C during deposition. There should also be the capability for in-situ QE measurements. In addition the preparation of dispenser photocathodes must be accounted for, thus requiring an ion source for cathode cleaning. Finally the transport cart must be mobile and be able to negotiate the ERL facility labyrinth.

43 PARTICLE ACCELERATORS↗

Evaluation of the irising effect of a slow-gating intensified charge-coupled device on laser-induced incandescence measurements of soot

Intensified charge-coupled devices (ICCDs) are used extensively in many scientific and engineering environments to image weak or temporally short optical events. To optimize the quantum efficiency of light collection, many of these devices are chosen to have characteristic intensifier gate times that are relatively slow, on the order of tens of nanoseconds. For many measurements associated with nanosecond laser sources, such as scattering-based diagnostics and most laser-induced fluorescence applications, the signals rise and decay sufficiently fast during and after the laser pulse that the intensifier gate may be set to close after the cessation of the signal and still effectively reject interferences associated with longer time scales. However, the relatively long time scale and complex temporal response of laser-induced incandescence (LII) of nanometer-sized particles (such as soot) offer a difficult challenge to the use of slow-gating ICCDs for quantitative measurements. In this paper, ultraviolet Rayleigh scattering imaging is used to quantify the irising effect of a slow-gating scientific ICCD camera, and an analysis is conducted of LII image data collected with this camera as a function of intensifier gate width. The results demonstrate that relatively prompt LII detection, generally desirable to minimize the influences of particle size and local gas pressure and temperature on measurements of the soot volume fraction, is strongly influenced by the irising effect of slow-gating ICCDs.

36 MATERIALS SCIENCE↗

A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems

Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of measuring the temporal MTF under fluoroscopic conditions using a moving slanted edge, a generalization of the slanted-edge method used to measure the (spatial) MTF, providing the temporal MTF of the entire imaging system. The method uses a single x-ray exposure, constant edge velocity, and assumes spatial and temporal blurring are separable. The method was validated on a laboratory x-ray image intensifier (XRII) system by comparison with direct measurements of the XRII optical response, showing excellent agreement over the entire frequency range tested ({+-}100 Hz). With proper access to linearized data and continuous fluoroscopy, this method can be implemented in a clinical setting on both XRII and flat-panel detectors. It is shown that the temporal MTF of the CsI-based validation system is a function of exposure rate. The rising-edge response showed more lag than the falling edge, and the temporal MTF decreased with decreasing exposure rate. It is suggested that a small-signal approach, in which the range of exposure rates is restricted to a linear range by using a semitransparent moving edge, would be appropriate for measuring the DQE of these systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale deformable registration for dual-energy x-ray imaging

Dual-energy (DE) imaging of the chest improves the conspicuity of subtle lung nodules through the removal of overlying anatomical noise. Recent work has shown double-shot DE imaging (i.e., successive acquisition of low- and high-energy projections) to provide detective quantum efficiency, spectral separation (and therefore contrast), and radiation dose superior to single-shot DE imaging configurations (e.g., with a CR cassette). However, the temporal separation between high-energy (HE) and low-energy (LE) image acquisition can result in motion artifacts in the DE images, reducing image quality and diminishing diagnostic performance. This has motivated the development of a deformable registration technique that aligns the HE image onto the LE image before DE decomposition. The algorithm reported here operates in multiple passes at progressively smaller scales and increasing resolution. The first pass addresses large-scale motion by means of mutual information optimization, while successive passes (2-4) correct misregistration at finer scales by means of normalized cross correlation. Evaluation of registration performance in 129 patients imaged using an experimental DE imaging prototype demonstrated a statistically significant improvement in image alignment. Specific to the cardiac region, the registration algorithm was found to outperform a simple cardiac-gating system designed to trigger both HE and LE exposures during diastole. Modulation transfer function (MTF) analysis reveals additional advantages in DE image quality in terms of noise reduction and edge enhancement. This algorithm could offer an important tool in enhancing DE image quality and potentially improving diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physical and psychophysical characterization of a novel clinical system for digital mammography

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light. In these detectors the readout is usually achieved through arrays of thin film transistors (TFTs). However, TFT readout tends to display noise characteristics worse than those from indirect detectors. To address this problem, a novel clinical system for digital mammography has been recently marketed based on direct-conversion detector and optical readout. This unit, named AMULET and manufactured by FUJIFILM, is based on a dual layer of amorphous selenium that acts both as a converter of x rays (first layer) and as an optical switch for the readout of signals (second layer) powered by a line light source. The optical readout is expected to improve the noise characteristics of the detector. The aim is to obtain images with high resolution and low noise, thanks to the combination of optical switching technology and direct conversion with amorphous selenium. In this article, the authors present a characterization of an AMULET system. Methods: The characterization was achieved in terms of physical figures as modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and contrast-detail analysis. The clinical unit was tested by exposing it to two different beams: 28 kV Mo/Mo (namely, RQA-M2) and 28 kV W/Rh (namely, W/Rh). Results: MTF values of the system are slightly worse than those recorded from other direct-conversion flat panels but still within the range of those from indirect flat panels: The MTF values of the AMULET system are about 45% and 15% at 5 and 8 lp/mm, respectively. On the other hand, however, AMULET NNPS results are consistently better than those from direct-conversion flat panels (up to two to three times lower) and flat panels based on scintillation phosphors. DQE results lie around 70% when RQA-M2 beams are used and approaches 80% in the case of W/Rh beams. Contrast-detail analysis, when performed by human observers on the AMULET system, results in values better than those published for other full-field digital mammography systems. Conclusions: The novel clinical unit based on direct-conversion detector and optical reading presents great results in terms of both physical and psychophysical characterizations. The good spatial resolution, combined with excellent noise properties, allows the achievement of very good DQE, better than those published for clinical FFDM systems. The psychophysical analysis confirms the excellent behavior of the AMULET unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum networks with neutral atom processing nodes

Abstract Quantum networks providing shared entanglement over a mesh of quantum nodes will revolutionize the field of quantum information science by offering novel applications in quantum computation, enhanced precision in networks of sensors and clocks, and efficient quantum communication over large distances. Recent experimental progress with individual neutral atoms demonstrates a high potential for implementing the crucial components of such networks. We highlight latest developments and near-term prospects on how arrays of individually controlled neutral atoms are suited for both efficient remote entanglement generation and large-scale quantum information processing, thereby providing the necessary features for sharing high-fidelity and error-corrected multi-qubit entangled states between the nodes. We describe both the functionality requirements and several examples for advanced, large-scale quantum networks composed of neutral atom processing nodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A mulitple cathode gun design for the eRHIC polarized electron source

The future electron-ion collider eRHIC requires a high average current ({approx}50 mA), short bunch ({approx}3 mm), low emittance ({approx}20 {micro}m) polarized electron source. The maximum average current of a polarized electron source so far is more than 1 mA, but much less than 50 mA, from a GaAs:Cs cathode. One possible approach to overcome the average current limit and to achieve the required 50 mA beam for eRHIC, is to combine beamlets from multiple cathodes to one beam. In this paper, we present the feasibility studies of this technique. The future eRHIC project, next upgrade of RHIC, will be the first electron-heavy ion collider in the world. It requires polarized electron source with a high average current ({approx}50 mA), short bunch ({approx}3 mm), emittance of about 20 {micro}m and energy spread of {approx}1% at 10 MeV. The state-of-art polarized electron cathode can generate average current of about more than 1 mA, but much less than 50 mA. The current is limited by the low quantum efficiency, space charge and ultra-high vacuum requirement of the polarized cathode. A possible approach to achieve the 50 mA beam is to employ multiple cathodes, such as 20 cathodes, and funnel the multiple bunched beams from cathodes to the same axis. Fig.1 illustrates schematically the concept of combining the multiple beams. We name it as 'Gatling gun' because it bears functional similarity to a Gatling gun. Laser beams strike the cathodes sequentially with revolution frequency of 700 kHz. Each beam bunch is focused by a solenoid and is bent toward the combiner. The combiner with rotating bending field bends all bunches arriving the combiner with a rotational pattern to the same axis. The energy of each bunch is modified by a bunching cavity (112MHz) and a 3rd harmonic cavity (336MHz). The bunch length is compressed ballistically in the drift space and is frozen after energy has been boosted to 10 MeV by the Booster linac. Each beam bunch contains 3.5 nC charge. The space charge is very strong at energy of 200 keV. A long bunch, {sigma} of 250 ps, is adopted to reduce the space charge on cathode. To compress the beam to final length of 3 mm (10 ps) can be achieved by ballistic compression with a 3rd harmonic cavity.

43 PARTICLE ACCELERATORS↗

Structural, thermal, optical properties and simulation of white light of titanium-tungstate-tellurite glasses doped with dysprosium

Graphical abstract: CIE coordinate diagram of different concentrations of the Dy{sup 3+}-doped TTWD glasses with coordinates in the white light region. - Highlights: • Radiative lifetime of {sup 4}F{sub 9/2} level of Dy{sup 3+} ions is longer in the tellurite glass. • Quantum efficiency is found to be high. • These glasses are suitable materials for generating white light. - Abstract: Structural, thermal, optical properties and simulation of white light of Dy{sup 3+}-doped tellurite glasses of composition TTWD: (75 − x)TeO{sub 2} − 10TiO{sub 2} − 15WO{sub 3} − xDy{sub 2}O{sub 3} (x = 0, 0.1, 0.5, 1.0 and 2.0 mol%) were investigated. Raman spectra revealed that the glass contains TeO{sub 4}, TeO{sub 3}, WO{sub 4} and WO{sub 6} units. Differential scanning calorimetry (DSC) measurements were carried out to measure the glass transition temperature of all the glasses. From the optical absorption spectra, luminescence spectra and using the Judd–Ofelt (JO) analysis, we estimated the radiative transition probabilities, emission cross-sections, branching ratios and radiative lifetimes. The decay curves at lower concentrations are exponential while they show a non-exponential behavior at higher concentrations (≥0.5 mol%) due to energy transfer processes. The effective lifetime for the {sup 4}F{sub 9/2} level decreases with increase in Dy{sub 2}O{sub 3} concentration for the glasses under investigation. The non-exponential decay curves could fit well to the Inokuti–Hirayama (IH) model with S = 6, indicating that the nature of interaction responsible for energy transfer is of dipole–dipole type. Simulation of white light is examined with varying concentration and the results indicate that these glasses are suitable for white light emitting diode applications.

36 MATERIALS SCIENCE↗

High broadband photoconductivity of few-layered MoS 2 field-effect transistors measured using multi-terminal methods: effects of contact resistance

Among the layered two dimensional semiconductors, molybdenum disulfide (MoS 2 ) is considered to be an excellent candidate for applications in optoelectronics and integrated circuits due to its layer-dependent tunable bandgap in the visible region, high ON/OFF current ratio in field-effect transistors (FET) and strong light–matter interaction properties. In this study, using multi-terminal measurements, we report high broadband photocurrent response ( R ) and external quantum efficiency (EQE) of few-atomic layered MoS 2 phototransistors fabricated on a SiO 2 dielectric substrate and encapsulated with a thin transparent polymer film of Cytop. The photocurrent response was measured using a white light source as well as a monochromatic light of wavelength λ = 400 nm–900 nm. We measured responsivity using a 2-terminal configuration as high as R = 1 × 10 3 A W -1 under white light illumination with an optical power P opt = 0.02 nW. The R value increased to 3.5 × 10 3 A W -1 when measured using a 4-terminal configuration. Using monochromatic light on the same device, the measured values of R were 10 3 and 6 × 10 3 A W -1 under illumination of λ = 400 nm when measured using 2- and 4-terminal methods, respectively. The highest EQE values obtained using λ = 400 nm were 10 5 % and 10 6 % measured using 2- and 4-terminal configurations, respectively. The wavelength dependent responsivity decreased from 400 nm to the near-IR region at 900 nm. The observed photoresponse, photocurrent–dark current ratio (PDCR), detectivity as a function of applied gate voltage, optical power, contact resistances and wavelength were measured and are discussed in detail. The observed responsivity is also thoroughly studied as a function of contact resistance of the device.

36 MATERIALS SCIENCE↗

Degradation of Alkali-Based Photocathodes from Exposure to Residual Gases: A First-Principles Study

Photocathodes are a key component in the production of electron beams in systems such as X-ray free-electron lasers and X-ray energy-recovery linacs. Alkali-based materials display high quantum efficiency (QE), however, their QE undergoes degradation faster than metal photocathodes even in the high vacuum conditions where they operate. The high reactivity of alkali-based surfaces points to surface reactions with residual gases as one of the most important factors for the degradation of QE. In order to advance the understanding on the degradation of the QE, we investigated the surface reactivity of common residual gas molecules (e.g., O 2 , CO 2 , CO, H 2 O, N 2 , and H 2 ) on one of the best-known alkali-based photocathode materials, cesium antimonide (Cs 3 Sb), using first-principles calculations based on density functional theory. Furthermore, the reaction sites, adsorption energy, and effect in the local electronic structure upon reaction of these molecules on (001), (110), and (111) surfaces of Cs 3 Sb were computed and analyzed. The adsorption energy of these molecules on Cs3Sb follows the trend of O 2 (-4.5 eV) > CO 2 (-1.9 eV) > H 2 O (-1.0 eV) > CO (-0.8 eV) > N 2 (-0.3 eV) ≈ H 2 (-0.2 eV), which agrees with experimental data on the effect of these gases on the degradation of QE. The interaction strength is determined by the charge transfer from the surfaces to the molecules. The adsorption and dissociation of O containing molecules modify the surface chemistry such as the composition, structure, charge distribution, surface dipole, and work function of Cs 3 Sb, resulting in the degradation of QE with exposure to O 2 , CO 2 , H 2 O, and CO.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface science analysis of GaAs photocathodes following sustained electron beam delivery

Degradation of the photocathode materials employed in photoinjectors represents a challenge for sustained operation of nuclear physics accelerators and high power Free Electron Lasers (FEL). Photocathode quantum efficiency (QE) degradation is due to residual gasses in the electron source vacuum system being ionized and accelerated back to the photocathode. These investigations are a first attempt to characterize the nature of the photocathode degradation, and employ multiple surface and bulk analysis techniques to investigate damage mechanisms including sputtering of the Cs-oxidant surface monolayer, other surface chemistry effects, and ion implantation. Surface and bulk analysis studies were conducted on two GaAs photocathodes, which were removed from the JLab FEL DC photoemission gun after delivering electron beam, and two control samples. The analysis techniques include Helium Ion Microscopy (HIM), Rutherford Backscattering Spectrometry (RBS), Atomic Force Microscopy (AFM) and Secondary Ion Mass Spectrometry (SIMS). In addition, two high-polarization strained superlattice GaAs photocathode samples, one removed from the Continuous Electron Beam Accelerator Facility (CEBAF) photoinjector and one unused, were also analyzed using Transmission Electron Microscopy (TEM) and SIMS. It was found that heat cleaning the FEL GaAs wafer introduces surface roughness, which seems to be reduced by prolonged use. The bulk GaAs samples retained a fairly well organized crystalline structure after delivering beam but shows evidence of Cs depletion on the surface. Within the precision of the SIMS and RBS measurements the data showed no indication of hydrogen implantation or lattice damage from ion back bombardment in the bulk GaAs wafers. In contrast, SIMS and TEM measurements of the strained superlattice photocathode show clear crystal damage in the wafer from ion back bombardment.

36 MATERIALS SCIENCE↗

High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose

Purpose: Electronic portal imaging devices (EPIDs) based on active matrix, flat-panel imagers (AMFPIs) have become the gold standard for portal imaging and are currently being investigated for megavoltage cone-beam computed tomography (CBCT) and cone-beam digital tomosynthesis (CBDT). However, the practical realization of such volumetric imaging techniques is constrained by the relatively low detective quantum efficiency (DQE) of AMFPI-based EPIDs at radiotherapy energies, {approx}1% at 6 MV. In order to significantly improve DQE, the authors are investigating thick, segmented scintillators, consisting of 2D matrices of scintillating crystals separated by septal walls. Methods: A newly constructed segmented BGO scintillator (11.3 mm thick) and three segmented CsI:Tl scintillators (11.4, 25.6, and 40.0 mm thick) were evaluated using a 6 MV photon beam. X-ray sensitivity, modulation transfer function, noise power spectrum, DQE, and phantom images were obtained using prototype EPIDs based on the four scintillators. Results: The BGO and CsI:Tl prototypes were found to exhibit improvement in DQE ranging from {approx}12 to 25 times that of a conventional AMFPI-based EPID at zero spatial frequency. All four prototype EPIDs provide significantly improved contrast resolution at extremely low doses, extending down to a single beam pulse. In particular, the BGO prototype provides contrast resolution comparable to that of the conventional EPID, but at 20 times less dose, with spatial resolution sufficient for identifying the boundaries of low-contrast objects. For this prototype, however, the BGO scintillator exhibited an undesirable radiation-induced variation in x-ray sensitivity. Conclusions: Prototype EPIDs based on thick, segmented BGO and CsI:Tl scintillators provide significantly improved portal imaging performance at extremely low dose (i.e., down to 1 beam pulse corresponding to {approx}0.022 cGy), creating the possibility of soft-tissue visualization using MV CBCT and CBDT at clinically practical dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of layer thickness on device response of silicon heavily supersaturated with sulfur

We report on a simple experiment in which the thickness of a hyperdoped silicon layer, supersaturated with sulfur by ion implantation followed by pulsed laser melting and rapid solidification, is systematically varied at constant average sulfur concentration, by varying the implantation energy, dose, and laser fluence. Contacts are deposited and the external quantum efficiency (EQE) is measured for visible wavelengths. We posit that the sulfur layer primarily absorbs light but contributes negligible photocurrent, and we seek to support this by analyzing the EQE data for the different layer thicknesses in two interlocking ways. In the first, we use the measured concentration depth profiles to obtain the approximate layer thicknesses, and, for each wavelength, fit the EQE vs. layer thickness curve to obtain the absorption coefficient of hyperdoped silicon for that wavelength. Comparison to literature values for the hyperdoped silicon absorption coefficients [S.H. Pan et al. Applied Physics Letters 98, 121913 (2011)] shows good agreement. Next, we essentially run this process in reverse; we fit with Beer’s law the curves of EQE vs. hyperdoped silicon absorption coefficient for those wavelengths that are primarily absorbed in the hyperdoped silicon layer, and find that the layer thicknesses obtained from the fit are in good agreement with the original values obtained from the depth profiles. We conclude that the data support our interpretation of the hyperdoped silicon layer as providing negligible photocurrent at high S concentrations. This work validates the absorption data of Pan et al. [Applied Physics Letters 98, 121913 (2011)], and is consistent with reports of short mobility-lifetime products in hyperdoped layers. It suggests that for optoelectronic devices containing hyperdoped layers, the most important contribution to the above band gap photoresponse may be due to photons absorbed below the hyperdoped layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amorphous In–Ga–Zn–O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis

Purpose: The breast cancer detection rate for digital breast tomosynthesis (DBT) is limited by the x-ray image quality. The limiting Nyquist frequency for current DBT systems is around 5 lp/mm, while the fine image details contained in the high spatial frequency region (>5 lp/mm) are lost. Also today the tomosynthesis patient dose is high (0.67–3.52 mGy). To address current issues, in this paper, for the first time, a high-resolution low-dose organic photodetector/amorphous In–Ga–Zn–O thin-film transistor (a-IGZO TFT) active pixel sensor (APS) x-ray imager is proposed for next generation DBT systems. Methods: The indirect x-ray detector is based on a combination of a novel low-cost organic photodiode (OPD) and a cesium iodide-based (CsI:Tl) scintillator. The proposed APS x-ray imager overcomes the difficulty of weak signal detection, when small pixel size and low exposure conditions are used, by an on-pixel signal amplification with a significant charge gain. The electrical performance of a-IGZO TFT APS pixel circuit is investigated by SPICE simulation using modified Rensselaer Polytechnic Institute amorphous silicon (a-Si:H) TFT model. Finally, the noise, detective quantum efficiency (DQE), and resolvability of the complete system are modeled using the cascaded system formalism. Results: The result demonstrates that a large charge gain of 31–122 is achieved for the proposed high-mobility (5–20 cm{sup 2}/V s) amorphous metal-oxide TFT APS. The charge gain is sufficient to eliminate the TFT thermal noise, flicker noise as well as the external readout circuit noise. Moreover, the low TFT (<10{sup −13} A) and OPD (<10{sup −8} A/cm{sup 2}) leakage currents can further reduce the APS noise. Cascaded system analysis shows that the proposed APS imager with a 75 μm pixel pitch can effectively resolve the Nyquist frequency of 6.67 lp/mm, which can be further improved to ∼10 lp/mm if the pixel pitch is reduced to 50 μm. Moreover, the detector entrance exposure per projection can be reduced from 1 to 0.3 mR without a significant reduction of DQE. The signal-to-noise ratio of the a-IGZO APS imager under 0.3 mR x-ray exposure is comparable to that of a-Si:H passive pixel sensor imager under 1 mR, indicating good image quality under low dose. A threefold reduction of current tomosynthesis dose is expected if proposed technology is combined with an advanced DBT image reconstruction method. Conclusions: The proposed a-IGZO APS x-ray imager with a pixel pitch <75 μm is capable to achieve a high spatial frequency (>6.67 lp/mm) and a low dose (<0.4 mGy) in next generation DBT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗