Search NASA⌕ Search

SEARCH · Search NASA

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Embedded expert system for space shuttle main engine maintenance

The SPARTA Embedded Expert System (SEES) is an intelligent health monitoring system that directs analysis by placing confidence factors on possible engine status and then recommends a course of action to an engineer or engine controller. The technique can prevent catastropic failures or costly rocket engine down time because of false alarms. Further, the SEES has potential as an on-board flight monitor for reusable rocket engine systems. The SEES methodology synergistically integrates vibration analysis, pattern recognition and communications theory techniques with an artificial intelligence technique - the Embedded Expert System (EES).

Pooley, J.↗

Rapidly Deployable Acoustic Monitoring and Localization System Based on a Low-Cost Wave Buoy Platform

The primary objective of this project is to develop a cost-effective, fit-for-purpose environmental monitoring system, “NoiseSpotter®,” that characterizes, classifies, and provides accurate location information for anthropogenic and natural sounds in near real-time. NoiseSpotter was developed to support the evaluation of potential acoustic effects of marine energy (ME) projects. By utilizing a compact array of three acoustic particle motion sensors, NoiseSpotter triangulates individual bearings to provide sound source localization to within 5% accuracy, allowing the ability to discern ME device sounds relative to other confounding sounds in the environment, while providing location estimates to nearby marine mammals for environmental mitigation purposes. The ME industry needs proven solutions to meet environmental impact assessment needs. The NoiseSpotter® includes off-the-shelf, modular components that are easy to assemble and disassemble. Its acoustic particle motion sensors are commercially available and the data logger and real-time telemetry system is designed to be plug-and-play. The entire system is relatively compact and can be deployed from small vessels. NoiseSpotter’s near real-time capability enables operational monitoring of ME sounds, particularly during early stages of technology adoption to facilitate mitigation of potential noise effects. Widespread adoption of the technology for acoustic monitoring of ME devices requires that it be cost effective; hence the anticipated commercial cost of system hardware is $35,000. This project contributes to reducing barriers to ME testing through support of scientific research focused on reducing or mitigating environmental risks and lowering costs and complexity of environmental monitoring. This project has developed an acoustic monitoring system, NoiseSpotter® (U.S. Patent No. 11,156,734 and U.S. Registered Trademark No. 6,442,313), to detect and characterize baseline noise and sounds from ME operations and support geolocation of detected sounds. The intended outcome of the project is to mitigate concerns about the potential for ME device noise to alter marine mammal or fish behavior. NoiseSpotter® enables cost-effective, near real-time acoustic monitoring of an operational ME device relative to ambient environmental noise and provides a technical basis for ME developers seeking to navigate the permitting process in an efficient manner.

16 TIDAL AND WAVE POWER↗

Real-time space system control with expert systems

Many aspects of space system operations involve continuous control of real time processes. These processes include electrical power system monitoring, prelaunch and ongoing propulsion system health and maintenance, environmental and life support systems, space suit checkout, onboard manufacturing, and vehicle servicing including satellites, shuttles, orbital maneuvering vehicles, orbital transfer vehicles and remote teleoperators. Traditionally, monitoring of these critical real time processes has been done by trained human experts monitoring telemetry data. However, the long duration of future space missions and the high cost of crew time in space creates a powerful economic incentive for the development of highly autonomous knowledge based expert control procedures for these space systems.

Leinweber, David↗

Experimental Validation of a Resilient Monitoring and Control System

Complex, high performance, engineering systems have to be closely monitored and controlled to ensure safe operation and protect public from potential hazards. One of the main challenges in designing monitoring and control algorithms for these systems is that sensors and actuators may be malfunctioning due to malicious or natural causes. To address this challenge, this paper addresses a resilient monitoring and control (ReMAC) system by expanding previously developed resilient condition assessment monitoring systems and Kalman filter-based diagnostic methods and integrating them with a supervisory controller developed here. While the monitoring and diagnostic algorithms assess plant cyber and physical health conditions, the supervisory controller selects, from a set of candidates, the best controller based on the current plant health assessments. To experimentally demonstrate its enhanced performance, the developed ReMAC system is then used for monitoring and control of a chemical reactor with a water cooling system in a hardware-in-the-loop setting, where the reactor is computer simulated and the water cooling system is implemented by a machine condition monitoring testbed at Idaho National Laboratory. Results show that the ReMAC system is able to make correct plant health assessments despite sensor malfunctioning due to cyber attacks and make decisions that achieve best control actions despite possible actuator malfunctioning. Monitoring challenges caused by mismatches between assumed system component models and actual measurements are also identified for future work.

97 MATHEMATICS AND COMPUTING↗

Overview of the national ignition facility

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory will be the world's largest and most powerful laser system for inertial confinement fusion (ICF) and experiments studying high energy density (HED) science. NIF is a 192 beam Nd-glass laser facility that will produce 1.8 MJ, 500 TW of ultraviolet light making it over fifty times more energetic than present ICF facilities. The NIF Project began in 1995 and is scheduled for completion in 2009. Ignition experiments on NIF, which will use tritium, are scheduled to begin in 2010. Tritium will arrive at the facility in individual target assemblies. The assemblies will be mounted to the Cryogenic Target Positioner (TARPOS), which provides the cryogenic cooling systems necessary to complete the formation of the ignition target's fuel ice layer. It also provides the positioning system that transports and holds the target at the center of the NIF chamber during a shot. After a shot, unburned tritium will be captured by the cryopumps. Upon regeneration, the cryopump effluent will be directed to the Tritium Processing System, part of NIF's. Personnel and Environmental Protection Systems. These systems also include, local contamination control systems, area and stack tritium monitoring systems, a decontamination area, and waste packaging and characterization capability. This equipment will be used along with standard contamination control practices to manage the tritium hazard to workers and to limit releases to the environment to negligibly small amounts. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NASA's Plans for Developing Life Support and Environmental Monitoring and Control Systems

Life Support and Monitoring have recently been reworked in response to the Vision for Space Exploration. The Exploration Life Support (ELS) Project has replaced the former Advanced Life Support Element of the Human Systems Research and Technology Office. Major differences between the two efforts include: the separation of thermal systems into a new stand alone thermal project, deferral of all work in the plant biological systems, relocation of food systems to another organization, an addition of a new project called habitation systems, and overall reduction in the number of technology options due to lower funding. The Advanced Environmental Monitoring and Control (AEMC) Element is retaining its name but changing its focus. The work planned in the ELS and AEMC projects is organized around the three major phases of the Exploration Program. The first phase is the Crew Exploration Vehicle (CEV). The ELS and AEMC projects will develop hardware for this short duration orbital and trans-lunar vehicle. The second phase is sortie landings on the moon. Life support hardware for lunar surface access vehicles including upgrades of the CEV equipment and technologies which could not be pursued in the first phase due to limited time and budget will be developed. Monitoring needs will address lunar dust issues, not applicable to orbital needs. The ELS and AEMC equipment is of short duration, but has different environmental considerations. The third phase will be a longer duration lunar outpost. This will consist of a new set of hardware developments better suited for long duration life support and associated monitoring needs on the lunar surface. The presentation will show the planned activities and technologies that are expected to be developed by the ELS and AEMC projects for these program phases.

Lawson, B. Michael↗

Reliability inputs to Mariner 9 data explosion

This paper describes the prelaunch and post-launch reliability functions which contributed to the success of the Mariner 9 spacecraft. Examples are included to illustrate how each reliability activity was a vital part of each phase of the project. Prelaunch reliability functions included: (1) establishing, negotiating, and monitoring system and subsystem requirements, (2) participating in spacecraft system and subsystem design/hardware reviews, (3) monitoring preparation of failure mode effects and criticality analyses (FMECA), (4) establishing and managing a problem failure reporting (PFR) system for the spacecraft and its support equipment, (5) monitoring electronic parts activities, and (6) participating in spacecraft reviews. Particular emphasis is placed on mission operations reliability assurance activities, which included: (1) spacecraft problem/failure reporting, (2) managing an integrating failure reporting system which covered all mission operations activities, (3) real-time analysis of spacecraft anomalies, and (4) risk assessment.

Macgregor, D. S.↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Laser-Pulse/Fiber-Optic Liquid-Leak Detector

Several potential leak sites monitored using single sensing fiber. Fluid systems monitored quickly for leaks in remote, hazardous, or inaccessible locations by system of compact, lightweight fiber-optic leak sensors presently undergoing development. Sensors installed at potential leak sites as joints, couplings, and fittings. Sensor read by sending laser pulse along fiber, then noting presence or relative amplitude of return pulse. Leak-monitoring technique applicable to wide range of fluid systems and minimizes human exposure to toxic or dangerous fluids.

Padgett, M. E.↗

Personal Cabin Pressure Monitor and Warning System

A cabin pressure altitude monitor and warning system provides a warning when a detected cabin pressure altitude has reached a predetermined level. The system is preferably embodied in a portable, pager-sized device that can be carried or worn by an individual. A microprocessor calculates the pressure altitude from signals generated by a calibrated pressure transducer and a temperature sensor that compensates for temperature variations in the signals generated by the pressure transducer. The microprocessor is programmed to generate a warning or alarm if a cabin pressure altitude exceeding a predetermined threshold is detected. Preferably, the microprocessor generates two different types of warning or alarm outputs, a first early warning or alert when a first pressure altitude is exceeded. and a second more serious alarm condition when either a second. higher pressure altitude is exceeded, or when the first pressure altitude has been exceeded for a predetermined period of time. Multiple types of alarm condition indicators are preferably provided, including visual, audible and tactile. The system is also preferably designed to detect gas concentrations and other ambient conditions, and thus incorporates other sensors, such as oxygen, relative humidity, carbon dioxide, carbon monoxide and ammonia sensors, to provide a more complete characterization and monitoring of the local environment.

Jan A Zysko↗

Intrusion Monitoring in Process Control Systems

To protect process control networks from cyber intrusions, preventive security measures such as perimeter defenses (for example, network firewalls and demilitarized zones) and secure versions of process control network protocols have been increasingly adopted or proposed. Although system hardening and fixing known vulnerabilities of existing systems are crucial to secure process control systems, intrusion monitoring is essential to ensure that the preventive measures are not compromised or bypassed. Our approach involves a multilayer security architecture for monitoring process control systems to achieve accurate and effective situational awareness. Also, we leverage some of the characteristics of process control systems such as the regularity of network traffic patterns to perform intrusion detection, with the potential to detect unknown attacks. To facilitate human analysts to gain a better understanding of anomalous network traffic patterns, we present a visualization tool that supports multiple usercustomizable views and animation for analyzing network packet traces.

97 MATHEMATICS AND COMPUTING↗

WM2024 Symposia Student Poster - ARG-US System Remote Area Monitoring at INL Experimental Proxy Design and Early Results

The patent-pending ARG-US system uses customizable high-tech sensors and monitoring systems in conjunction with a remote network connection to provide easy and quick access to the status of nuclear and radiological facilities and storage containers. In a partnership with the Argonne National Laboratory and the Idaho National Laboratory, the research team are finding new ways to customize and test the limitations the ARG-US system. This presentation is for the student poster session.

99 GENERAL AND MISCELLANEOUS↗

Determination of monitor unit check tolerances based on a comparison with measurement and treatment planning system data

ABSTRACT: This work describes the experimental validation of treatment planning system monitor unit (MU) calculations against measurement for a range of scenarios. This, together with a comparison of treatment planning system MUs and an independent MU check method, allows the derivation of confidence intervals for the check process. Data were collected for open and 60° motorized wedge fields using an Elekta Synergy linac at 6 and 8 MV using homogeneous and heterogeneous phantoms. Masterplan (Version 4.0) pencil-beam and collapsed cone algorithms were used for the primary MU calculations with full inhomogeneity correction. Results show that both algorithms agree with measurement to acceptable tolerance levels in the majority of the cases studied. The confidence interval for the pencil-beam algorithm MU against an independent check was determined as + 1.6% to −3.4%. This is modified to + 2.3% to −2.5% when data collected with low-density heterogeneities are removed as this algorithm is not used clinically for these cases. The corresponding interval for the collapsed cone algorithm was + 1.2% to −4.3%, indicating that an offset tolerance for the independent check is appropriate. Analysis of clinical conformal treatment plan data generated using the pencil-beam algorithm (1393 beams) returned 93% of beams within the independent check tolerance. Similarly, using the collapsed cone algorithm as the primary MU calculation, 77% (of 1434 beams) were within the confidence interval.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computer program analyzes and monitors electrical power systems (POSIMO)

Requirements to monitor and/or simulate electric power distribution, power balance, and charge budget are discussed. Computer program to analyze power system and generate set of characteristic power system data is described. Application to status indicators to denote different exclusive conditions is presented.

Jaeger, K.↗

Knowledge-Acquisition Tool For Expert System

Digital flight-control systems monitored by computer program that evaluates and recommends. Flight-systems engineers for advanced, high-performance aircraft use knowlege-acquisition tool for expert-system flight-status monitor suppling interpretative data. Interpretative function especially important in time-critical, high-stress situations because it facilitates problem identification and corrective strategy. Conditions evaluated and recommendations made by ground-based engineers having essential knowledge for analysis and monitoring of performances of advanced aircraft systems.

Disbrow, James D.↗

Detector positioning for the initial subcriticality level determination in accelerator-driven systems

Within the GUINEVERE project (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) carried out at SCK-CEN in Mol, the continuous deuteron accelerator GENEPI-3C was coupled to the VENUS-F fast simulated lead-cooled reactor. Today the FREYA project (Fast Reactor Experiments for hYbrid Applications) is ongoing to study the neutronic behavior of this Accelerator Driven System (ADS) during different phases of operation. In particular the set-up of a monitoring system for the subcriticality of an ADS is envisaged to guarantee safe operation of the installation. The methodology for subcriticality monitoring in ADS takes into account the determination of the initial subcriticality level, the monitoring of reactivity variations, and interim cross-checking. At start-up, the Pulsed Neutron Source (PNS) technique is envisaged to determine the initial subcriticality level. Thanks to its reference critical state, the PNS technique can be validated on the VENUS-F core. A detector positioning methodology for the PNS technique is set up in this paper for the subcritical VENUS-F core, based on the reduction of higher harmonics in a static evaluation of the Sjoestrand area method. A first case study is provided on the VENUS-F core. This method can be generalised in order to create general rules for detector positions and types for full-scale ADS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capacitive system detects and locates fluid leaks

Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.

Source record↗