Search NASASearch

SEARCH · Search NASA

Results for “Space Thermal Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,475 records · Page 73

Investigating permafrost carbon dynamics in Alaska with artificial intelligence

Abstract Positive feedbacks between permafrost degradation and the release of soil carbon into the atmosphere impact land–atmosphere interactions, disrupt the global carbon cycle, and accelerate climate change. The widespread distribution of thawing permafrost is causing a cascade of geophysical and biochemical disturbances with global impacts. Currently, few earth system models account for permafrost carbon feedback (PCF) mechanisms. This research study integrates artificial intelligence (AI) tools and information derived from field-scale surveys across the tundra and boreal landscapes in Alaska. We identify and interpret the permafrost carbon cycling links and feedback sensitivities with GeoCryoAI, a hybridized multimodal deep learning (DL) architecture of stacked convolutionally layered, memory-encoded recurrent neural networks (NN). This framework integratesin-situmeasurements and flux tower observations for teacher forcing and model training. Preliminary experiments to quantify, validate, and forecast permafrost degradation and carbon efflux across Alaska demonstrate the fidelity of this data-driven architecture. More specifically, GeoCryoAI logs the ecological memory and effectively learns covariate dynamics while demonstrating an aptitude to simulate and forecast PCF dynamics—active layer thickness (ALT), carbon dioxide flux (CO 2 ), and methane flux (CH 4 )—with high precision and minimal loss (i.e. ALT RMSE : 1.327 cm [1969–2022]; CO 2 RMSE : 0.697µmolCO 2 m −2 s −1 [2003–2021]; CH 4 RMSE : 0.715 nmolCH 4 m −2 s −1 [2011–2022]). ALT variability is a sensitive harbinger of change, a unique signal characterizing the PCF, and our model is the first characterization of these dynamics across space and time.

Environmental Sciences & Ecology

Lake sediment heatwaves under global warming

Lake sediment heatwaves, driven by rising global temperatures, pose emerging threats to freshwater ecosystems by altering sediment thermal regimes and intensifying sediment biogeochemical processes. Here we present a global-scale assessment of lake sediment heatwaves, examining their historical patterns and projecting future trends under various climate scenarios in 41,499 representative lakes worldwide. Using daily simulated lake sediment temperatures from 1981 to 2010 and future (2071-2100) projections under three Shared Socioeconomic Pathways (SSP126, SSP370, SSP585), we investigate lake sediment heatwave characteristics, including their duration, intensity, frequency, and seasonal timing, worldwide. Our results show that lake sediment heatwaves are generally more persistent and frequent than lake surface heatwaves, with sediment heatwaves in pelagic regions experiencing a significant lag relative to surface conditions. Under future climate scenarios, sediment heatwaves are projected to intensify, with their duration and frequency increasing substantially, particularly under SSP585. These shifts could exacerbate the production of greenhouse gases like methane and increase sediment respiration rates in lakes. This study highlights the need to account for sediment heatwaves in freshwater ecosystem management and climate adaptation strategies to mitigate future impacts.

Limnology

Uranus Orbiter and Probe: Mission Challenges and Concept Updates Since the Origins, Worlds, and Life Decadal Survey

Origins, Worlds, and Life: Planetary Science and Astrobiology in the Next Decade identified a Uranus Orbiter and Probe as the highest-priority strategic mission for the decade 2023–2032, as it enables broad cross-disciplinary science in the largely unexplored Uranian system. The mission architecture evaluated by the Decadal Survey was a singular proof of concept demonstrating that a moderately instrumented mission could deliver Decadal-priority science with a reduced cost and risk posture by leveraging existing technologies to the maximum extent possible. With revised assumptions since the Decadal, we have explored a large trade space including launch vehicles, propulsion options, cruise trajectories, available power sources, viable concept of operations, and science data return for later launch dates without a Jupiter gravity assist. The most repeatable trajectory solutions employ either a commercially derived solar electric propulsion (SEP) transfer stage or the availability of a more capable launch vehicle under development, such as the SpaceX Starship. Orbit insertion has been moved farther from Uranus to acknowledge the remaining uncertainty in Uranian ring structure. A streamlined, SEP-adaptable, orbiter design was developed using two Next Gen Radioisotope Thermoelectric Generators, and the probe design was matured, reducing the entry gravitational acceleration, and assuming the largest Decadal-recommended payload to provide margin for future instrument selections. With this updated design, we also constructed a detailed concept of operations for three representative science cases, returning 13–15 Gbit of science data and spacecraft telemetry per ∼34 day orbit.

Amy A Simon

Tunable Metasurface External-Cavity Quantum Cascade Lasers up to 5.74 THz

Vertical-external-cavity surface-emitting lasers based on amplifying quantum-cascade metasurfaces are demonstrated in the 5–6 THz range for the first time. Enhanced parasitic coupling to lossy surface modes requires updated design guidelines, while elevated losses and lower available material gain limit the scaling of the metasurface period from previous designs. A series of metasurface devices with varying periods employing both uniform and focusing metasurfaces is fabricated and characterized. Reducing the metasurface period below 70% of the free-space wavelength enables devices with superior performance, achieving pulsed operation up to 5.74 THz with peak output powers of 1.3 mW, maximum operating temperatures up to 83 K, and continuous-wave operation up to 54 K with 23 μW of output power. In the best case, single-mode tuning from 5.23–5.73 THz, which corresponds to a 9.1% fractional tuning, is realized with near-Gaussian far-field profiles maintained across the entire range. Finally, these results establish quantum cascade vertical-external-cavity surface-emitting lasers as promising candidates for high-frequency local oscillator applications in heterodyne spectroscopy.

gallium arsenide

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

Brewer, Jeffrey C.

Nuclear Safety [Vol. 34, No. 1, January-March 1993]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 An Integrated Regional Approach To Risk Management of Industrial Systems, S. Chakraborty and R. Stratton; 9 Annual Technical Meeting of the NRC Cooperative Severe Accident Research Program, E. G. Silver; ACCIDENT ANALYSIS: 13 Deterministic Severe Accident Criteria as Severe Accident Design Criteria and Policy for the New Production Reactor-Heavy Water Reactor, P. T. Rhoads; 20 Proposed Deterministic Severe Accident Criteria for the Heavy Water Reactor-New Production Reactor Containment, K. D. Bergeron, S. E. Slezak, and C. E. Leach; 33 Quasi-Static Core Liquid Level Depression and Long-Term Core Uncovery During a PWR LOCA, Y. Kukita, R. R. Schultz, H. Nakamura, and J. Katayama; 49 LIRA: An Advanced Containment System to Minimize the Accidental Radioactivity Releases, A. Turricchia; 63 Errata to “A Review of Hydrogen Production During Melt/Water Interaction in LWRs,” Vol. 33, No. 4; CONTROL AND INSTRUMENTATION: 64 The Nuplex 80+™ Advanced Control Complex from ABB Combustion Engineering, F. Ridolfo, D. Harmon, and K. Scarola; DESIGN FEATURES: 76 A Scheme for Passive Isolation of the Containment of a Reactor, A. K. Ghosh, V. V. Raj, and K. Kakodkar; 84 Utility Requirements for Safety in the Passive Advanced Light-Water Reactor, T. U. Marston, W. H. Layman, and G. Bockhold, Jr.; WASTE AND SPENT FUEL MANAGEMENT: 91 Activities Related to Waste and Spent Fuel Management, Compiled by M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 103 Testing Deficiencies in Auxiliary Systems Feedwater Systems, J. D. Kueck; 110 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 113 Selected Safety-Related Events, Compiled by G. A. Murphy; 115 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; RECENT DEVELOPMENTS: 133 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 145 Reports, Standards, and Safety Guides, D. S. Queener; 150 Proposed Rule Changes as of Sept. 30, 1992; ANNOUNCEMENTS: 75 Harvard Short Course on Risk: Science, Assessment, and Management; 102 International Conference on Reactor Physics and Reactor Computations; 102 The Fourth International Conference on Nuclear Waste Reprocessing and Waste Management [RECOD ’94]; 132 International Symposium on the Radiological Exposure of the Population of the European Community from Radioactivity in the Mediterranean Sea [MARINA-MED]; 162 International High-Level Radioactive Waste Conference ‘Technology Integration—Above and Below”; 154 The Authors; 158 Indexes to Nuclear Safety, Volume 33.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A Parametric Battery Model for the Conceptual Design of Electric Aircraft

Electric aircraft conceptual designs usually have an assumed specific power and specific energy for the aircraft’s energy storage system that dictates the total capacity and the peak power available. The specific energy and power are inherently linked to the state-of-charge and discharge rate from which they were derived; therefore, they will not directly correspond to the diverse circumstances encountered in various aircraft missions and flight segments. These parameters turn the battery system into a black box, disregard potential electrical restrictions, and disallow the aircraft and battery to be optimized as a system. Peering into this box, this study highlights the importance of incorporating a parametric battery model into the conceptual design workflow by splitting high-level terms such as power into voltage and current and investigating their variability during the discharge process. Through the modeling of these more detailed parameters, this methodology shows the feasibility of using low states-of-charge for contingency operations, including the end of the reserve mission, expanding the amount of usable capacity for electric aircraft. Stark differences in aircraft capabilities can arise between varying fidelity battery models due to late-mission, high-power flight operations. This parametric battery model effectively captures these differences by evaluating the limitations that arise within the individual battery cells and the aircraft powertrain. This paper shows that the unusable charge of a battery is set by the balked landing power requirement and can realistically range from 5% to 44% based on assumptions. This sets the analog to unusable fuel capacity in aircraft with liquid fuel systems. Needing only aircraft- and mission-level inputs and only seconds of run time, this model is a prime fit for the fast, accurate exploration of the electric aircraft conceptual design space.

Battery

Hybrid Data‐Driven Discovery of High‐Performance Silver Selenide‐Based Thermoelectric Composites

Optimizing material compositions often enhances thermoelectric performances. However, the large selection of possible base elements and dopants results in a vast composition design space that is too large to systematically search using solely domain knowledge. To address this challenge, a hybrid data-driven strategy that integrates Bayesian optimization (BO) and Gaussian process regression (GPR) is proposed to optimize the composition of five elements (Ag, Se, S, Cu, and Te) in AgSe-based thermoelectric materials. Data is collected from the literature to provide prior knowledge for the initial GPR model, which is updated by actively collected experimental data during the iteration between BO and experiments. Within seven iterations, the optimized AgSe-based materials prepared using a simple high-throughput ink mixing and blade coating method deliver a high power factor of 2100 µW m −1 K −2 , which is a 75% improvement from the baseline composite (nominal composition of Ag 2 Se 1 ). In conclusion, the success of this study provides opportunities to generalize the demonstrated active machine learning technique to accelerate the development and optimization of a wide range of material systems with reduced experimental trials.

36 MATERIALS SCIENCE

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified. These empirical models were used to predict noise levels and compared against hydrogen noise data reported in two studies: one experimental study of noise from hydrogen leaking through a pipe and another which modeled hydrogen flowing through a solenoid valve during a fuel cell vehicle refueling. The valve flow model was then applied to predict noise for hydrogen releases through a TPRD. Results show that hydrogen releases through a TPRD can produce harmful noise levels varying from 134 to 150 dB. However, further model validation and additional experimental data are needed to improve prediction confidence and accuracy.

08 HYDROGEN

WINDSAT Free Flyer Using the Advanced TIROS-N Satellite

The results of this study show the feasibility of carrying a wind measuring lidar on an ATN-derivative free flying spacecraft. The overall configuration fits within the Shuttle bay and uses the same techniques for STS Launch as the proposed SAATN spacecraft. The lidar can be made light enough that the total weight of the satellite is well within the capability of the onboard propulsion system for transfers to a Sun synchronous orbit at 833 km attitude. The principal techniques for weight minimization are the use of the Perkin Elmer proprietary HIP process for the telescope, new packaging concepts for the laser and for the optics-laser interface, and the application of current technology to the signal processing hardware. Power minimization is achieved for the lidar primarily by use of a low pulse repetition frequency, i.e., 2pps, and again by the use of current processor technology. The power capability of the spacecraft is enhanced by increasing the ATN array size 25 percent, through the addition of two more solar array panels of the present size, and by limiting the range of Sun angles over which the spacecraft is operated. The same basic concept for the lidar as proposed in the Shuttle Windsat study is recommended here, but there are some changes in details to improve weight and power. No major technology break-throughs are required for the lidar, but some technology experiments are recommended for the laser subsystem to verify isotopic gas lifetime and performance, modulator life and weight, and for space qualification. Spacecraft changes are all natural modifications or growth to accommodate the payload. Overall, the proposed system provides substantial margin for the uncertainties for the future and for potential payload change, and also demonstrates the reasonableness of the Windsat Free Flyer concept.

Herbert M Gurk

Gas permeation properties of amorphous zeolitic imidazolate framework membranes made by atomic/molecular layer deposition

Amorphous metal-organic framework (MOF) membranes are desirable because they may retain some of the molecular sieving properties of their crystalline counterparts while being free of grain boundary defects, which often hinder the consistent achievement of high membrane performance. However, current methods, like melting and compression, for fabricating amorphous MOF membranes involve multi-step processes that require the formation of a crystalline membrane first, that is then amorphized, and therefore, could be challenging to scale. Here, we utilize atomic/molecular layer deposition (ALD/MLD) of diethylzinc (DEZ) and 2-methylimidazole (2mIm) to directly synthesize ultrathin amorphous zeolitic imidazolate framework (aZIF) deposits on γ-alumina-coated α-alumina supports. As the number of ALD/MLD cycles increased from 10 to 300, gas permeances decreased while ideal selectivities increased. Mixture separation factors for C3H6/C3H8, CO2/N2, and H2/C3H8 as high as 4, 37, and 194, respectively, were obtained. At 200 °C and 2.5 bar equimolar feed of H2 and C3H8, a H2/C3H8 mixture separation factor of 185 is obtained with an H2 permeance of ca. 4.15x10-8 mol/m2-s-Pa (124 GPU). Additionally, the membrane achieves a CO2/N2 mixture separation factor of 37 at 25 °C and 1 bar with a CO2 permeance of ca. 3.96x10-8 mol/m2-s-Pa (118 GPU). Considering the vast array of compositionally distinct aZIFs that can be potentially deposited by this approach, an enormously large parameter space for membrane design is emerging to be explored.

36 MATERIALS SCIENCE

Swamp Works Regolith Compaction Technologies

While the level of compaction below the lunar surface increases quickly after only a few cm of depth, in many cases during a construction mission there will be a need to excavate and transport regolith to a new location for cut-and-fill or horizontal construction of structures such as berms. In these cases to achieve high levels of bulk density, compaction must be per-formed. Additionally, in some cases surface technologies such as systems that sinter/melt the surface may desire the maximum possible compaction at the sur-face to improve melting/heating performance and the final material strength properties. Kennedy Space Center’s (KSC) Swamp Works has developed two means of compaction, lunar and mar-tian compaction. Planetary Autonomous Compaction Technology (PACT) which is part of the Multifunction End Effector for Regolith Compaction Acquisition and Transfer (MEERCAT) robotic arm end effector system’s capabilities and the Site Preparation Tooling for Operations on Mobility Platforms (STOMP) vibratory roller compactor. PACT on MEERCAT has been demonstrated to a TRL 5 and STOMP to a TRL 4 in ambient testing. The results of PACT on MEERCAT and STOMP testing will be shared with results for various simulants including BP-1, ICN-LHT-1G (aka CSM-LHT-1G), RDW-LHT-1GH (a simulant developed for the Mason Tipping Point to match characteristics of ICN-LHT-1G), and Exolith LHS-1E. This will also include discussions on methods used to verify relative density before and after compaction and means to verify density effects below depth. To calculate relative density, maximum and minimum densities for simulants were taken from literature and additional lab testing (publication in work).

redwire

Collapse of magnetized white dwarfs as site of heavy-element formation and kilonova signal

We present the first end-to-end calculation connecting the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf to observable kilonova signatures, combining two-dimensional (2D) general-relativistic neutrino-magnetohydrodynamic simulations, followed by radiation hydrodynamics with in-situ nuclear network and 2D Monte Carlo radiative transfer with spatially resolved heating rates. Unlike all previous unmagnetized AIC models – which predicted proton-rich, $^{56}$Ni-dominated ejecta – strong magnetic fields eject ${\approx }\, 0.2\, \mathrm{ M}_\odot$ of neutron-rich material ($\langle Y_e \rangle \sim 0.24$) on dynamical time-scales, before neutrino irradiation can raise the electron fraction, enabling strong r-process nucleosynthesis up to and beyond the third peak. The resulting kilonova is lanthanide-rich ($X_{\rm lan} \approx 8~{{\ \rm per\ cent}}$) and dominated by near-infrared emission. We compute synthetic light curves in the Large Synoptic Survey Telescope and J ames Webb Space Telescope bands and find striking agreement, without parameter tuning, between the observations of AT 2023vfi/GRB 230307A and our broadband light curves for polar viewing angles. These results establish magnetized AIC as a viable channel for heavy r-process element production and a compelling progenitor candidate for long-duration gamma-ray bursts with kilonova signatures.

MHD

Simulations of Yarn Micro-Mechanics of Woven Heat Shield Materials

Carbon and phenolic fibers are commonly used in ablative thermal protection materials, such as 3-dimensional Mid-Density Carbon Phenolic (3MDCP), a 3D-woven composite comprised of mixed-fiber yarn bundles. Predicting the micro-mechanical response and fracture of twisted yarns composed of brittle and ductile fibers requires a modeling approach that captures per-fiber yielding, fiber fracture, and inter-fiber friction and contact. This work presents an extended bonded particle model (BPM) for discrete element method (DEM) simulation of fiber and yarn mechanics, implemented in LAMMPS. The model builds on the incremental bond formulation of Guo et al. and introduces a piecewise elasto-plastic constitutive law for axial extension, enabling representation of fibers that yield before failure. 3MDCP yarns were constructed using measured fiber radius distributions and helical twist geometry. Tensile simulations of single-ply 3MDCP yarns show good agreement with vender stress–strain results. Fiber breakage models also show details on yarn breakage propagration, centered radially in the yarn. Yarn breakage of multi-ply 3MDCP also matched experimental observations in per-ply breakage; however, predicted yarn breakage strength were found higher than experimental observations.

Discrete Element Method

Simulations of Yarn Micro-Mechanics of Woven Heat Shield Materials (3MDCP)

Carbon and phenolic fibers are commonly used in ablative thermal protection materials, such as 3-dimensional Mid-Density Carbon Phenolic (3MDCP), a 3D-woven composite comprised of mixed-fiber yarn bundles. Predicting the micro-mechanical response and fracture of twisted yarns composed of brittle and ductile fibers requires a modeling approach that captures per-fiber yielding, fiber fracture, and inter-fiber friction and contact. This work presents an extended bonded particle model (BPM) for discrete element method (DEM) simulation of fiber and yarn mechanics, implemented in LAMMPS. The model builds on the incremental bond formulation of Guo et al. and introduces a piecewise elasto-plastic constitutive law for axial extension, enabling representation of fibers that yield before failure. 3MDCP yarns were constructed using measured fiber radius distributions and helical twist geometry. Tensile simulations of single-ply 3MDCP yarns show good agreement with vender stress–strain results. Fiber breakage models also show details on yarn breakage propagration, centered radially in the yarn. Yarn breakage of multi-ply 3MDCP also matched experimental observations in per-ply breakage; however, predicted yarn breakage strength were found higher than experimental observations.

Woven

Electron Microscopy Studies of Soft Nanomaterials

This review highlights recent efforts on applying electron microscopy (EM) to soft (including biological) nanomaterials. We will show how developments of both the hardware and software of EM have enabled new insights into the formation, assembly, and functioning (e.g., energy conversion and storage, phonon/photon modulation) of these materials by providing shape, size, phase, structural, and chemical information at the nanometer or higher spatial resolution. Specifically, we first discuss standard real-space two-dimensional imaging and analytical techniques which are offered conveniently by microscopes without special holders or advanced beam technology. The discussion is then extended to recent advancements, including visualizing three-dimensional morphology of soft nanomaterials using electron tomography and its variations, identifying local structure and strain by electron diffraction, and recording motions and transformation by in situ EM. On these advancements, we cover state-of-the-art technologies designed for overcoming the technical barriers for EM to characterize soft materials as well as representative application examples. Here, the even more recent integration of machine learning and its impacts on EM are also discussed in detail. With our perspectives of future opportunities offered at the end, we expect this review to inspire and stimulate more efforts in developing and utilizing EM-based characterization methods for soft nanomaterials at the atomic to nanometer length scales in academic research and industrial applications.

Imaging