Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

The implementation of POSTGRES

The design and implementation decisions made for the three-dimensional data manager POSTGRES are discussed. Attention is restricted to the DBMS backend functions. The POSTGRES data model and query language, the rules system, the storage system, the POSTGRES implementation, and the current status and performance are discussed.

Stonebraker, Michael↗

Advanced satellite workstation: An integrated workstation environment for operational support of satellite system planning and analysis

A prototype integrated environment, the Advanced Satellite Workstation (ASW), is described that has been developed and delivered for evaluation and operator feedback in an operational satellite control center. The current ASW hardware consists of a Sun Workstation and Macintosh II Workstation connected via an ethernet Network Hardware and Software, Laser Disk System, Optical Storage System, and Telemetry Data File Interface. The central mission of ASW is to provide an intelligent decision support and training environment for operator/analysts of complex systems such as satellites. There have been many workstation implementations recently which incorporate graphical telemetry displays and expert systems. ASW is a considerably broader look at intelligent, integrated environments for decision support, based upon the premise that the central features of such an environment are intelligent data access and integrated toolsets. A variety of tools have been constructed in support of this prototype environment including: an automated pass planner for scheduling vehicle support activities, architectural modeler for hierarchical simulation and analysis of satellite vehicle subsystems, multimedia-based information systems that provide an intuitive and easily accessible interface to Orbit Operations Handbook and other relevant support documentation, and a data analysis architecture that integrates user modifiable telemetry display systems, expert systems for background data analysis, and interfaces to the multimedia system via inter-process communication.

Sutton, Stewart A.↗

LCOH Estimated from Existing Geothermal District Heating Systems in the U.S.

Levelized cost of heat for geothermal district heating systems in the US was calculated from reported construction and operation costs obtained from a literature review. These costs were inflation adjusted to 2016 dollars. To obtain geothermal district heating levelized cost of heat, capital costs were amortized over 30 years with an interest rate of 4%. These results suggest that the levelized cost of heat produced in these systems is on the order of $35,750 per gigawatt hr (thermal). Expressed in more common units, the levelized cost of geothermal district heat is $36/MWh (~$10.5/MMBtu). This cost is reflective of state-of-the-art systems at the time of installation and does not account for recent technology advances such as combine heating/cooling systems and storage systems.

15 GEOTHERMAL ENERGY↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

HI-STORM Overpack and MPC-32 Thermal-Hydraulic Model with MOOSE Framework

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a MOOSE thermal model of the MPC-32 canister and HI-STORM overpack

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact System for Operating and Decommissioned Reactor Used Fuel Management - 17243

Most nuclear power plants in operation today were designed with limited wet storage for their discharged used nuclear fuel (UNF), predicated on the assumption that either recycling or geologic storage would be available within the reactor's lifetime. While that has proven to be the case in some countries such as France with its recycling, it has not for most. In the USA, dry storage of UNF at the plant site at an Independent Spent Fuel Storage Installation (ISFSI) has since the mid-1980s been the primary mode of interim storage so that the plant can off-load its UNF from the pools at the power plants. Initially the space reserved for the ISFSI at a reactor site was based on the assumption that the Department of Energy (DOE) would be transporting that UNF to a geological repository site, such as Yucca Mountain, by 1998. However, due to the delay in the opening of any geological repository the utilities are running out of space on their existing ISFSIs for additional UNF dry storage systems. Since plants prefer to keep their ISFSIs inside the protected area of the plant, options for expanding the ISFSI are becoming limited. At the same time, increasing the capacity of the dry storage systems is also not an option in most cases as the dry storage systems have almost reached their capacity limits with the 37 PWR or 89 BWR fuel assembly canister designs. For plants that have announced plans to shut down, their main priority is to off-load the UNF from the pool to dry storage at an ISFSI so that they can proceed to 'Safe store' or other storage options, and start their decommissioning process as soon as possible. Thus, keeping the size of the ISFSI compact is very important for safety, security and economics. This paper will describe the details of a reduced footprint version of AREVA TN's NUHOMS{sup R} System that addresses the need for maximizing ISFSI capacity. This system not only offers a compact design that stores nearly double the number of UNF assemblies in the same space, it also offers superior radiation protection to the workers and public. In addition, it offers unmatched protection against beyond design basis (BDB) events like the tsunami at Fukushima in Japan, the earthquake at North Anna site, tornadoes and manmade attacks such as the 9/11 attack on the World Trade Center in New York. It also includes significant enhancement for a robust Canister Evolved Safety Program for Aging Management. The utilities in the USA are currently using dry storage systems with canisters of different diameter, different length, and different weights. The fuel assemblies that are stored in these canisters are also different in their fuel types (PWR or BWR),different fuel parameters like burnups, enrichments, and cooling times and different storage orientations in the storage overpacks like horizontal or vertical. The compact version of AREVA TN's NUHOMS{sup R} System offers a 'Universal' Storage Overpack which is designed to accept all these different design dry storage canister available in the industry. As UNF storage continues to drives the industry towards innovations that address the need for consolidated storage, compact ISFSIs and aging management, this new evolution of the AREVA TN NUHOMS{sup R} system offers a significant leap forward in addressing all of these challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy storage using an REP with an engine

An energy storage system includes a power plant configured to generate an exhaust gas comprising carbon dioxide. The energy storage system further includes a first fuel cell configured to operate in reverse as an electrolyzer. The first fuel cell is configured to receive at least a portion of the exhaust gas from the power plant. An anode is configured to receive carbon dioxide via the exhaust gas and methane from a separate feed, and the anode is configured to output a hydrogen-containing gas mixture. The energy storage system further includes a reformer configured to methanate the hydrogen-containing gas mixture to convert substantially all of the carbon monoxide in the hydrogen-containing gas mixture to methane. The energy storage system further includes a second fuel cell operating in reverse as a hydrogen pump, the second fuel cell configured to separate hydrogen from a gas mixture output by the reformer.

25 ENERGY STORAGE↗

Inspection of Used Fuel Dry Storage Casks

The U.S. Nuclear Regulatory Commission (NRC) regulates the storage of used nuclear fuel, which is now and will be increasingly placed in dry storage systems. Since a final disposition pathway is not defined, the fuel is expected to be maintained in dry storage well beyond the time frame originally intended. Due to knowledge gaps regarding the viability of current dry storage systems for long term use, efforts are underway to acquire the technical knowledge and tools required to understand the issues and verify the integrity of the dry storage system components. This report summarizes the initial efforts performed by researchers at Idaho National Laboratory and Argonne National Laboratory to identify and evaluate approaches to in-situ inspection dry storage casks. This task is complicated by the design of the current storage systems that severely restrict access to the casks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated clustering-based workload characterization

The demands placed on the mass storage systems at various federal agencies and national laboratories are continuously increasing in intensity. This forces system managers to constantly monitor the system, evaluate the demand placed on it, and tune it appropriately using either heuristics based on experience or analytic models. Performance models require an accurate workload characterization. This can be a laborious and time consuming process. It became evident from our experience that a tool is necessary to automate the workload characterization process. This paper presents the design and discusses the implementation of a tool for workload characterization of mass storage systems. The main features of the tool discussed here are: (1)Automatic support for peak-period determination. Histograms of system activity are generated and presented to the user for peak-period determination; (2) Automatic clustering analysis. The data collected from the mass storage system logs is clustered using clustering algorithms and tightness measures to limit the number of generated clusters; (3) Reporting of varied file statistics. The tool computes several statistics on file sizes such as average, standard deviation, minimum, maximum, frequency, as well as average transfer time. These statistics are given on a per cluster basis; (4) Portability. The tool can easily be used to characterize the workload in mass storage systems of different vendors. The user needs to specify through a simple log description language how the a specific log should be interpreted. The rest of this paper is organized as follows. Section two presents basic concepts in workload characterization as they apply to mass storage systems. Section three describes clustering algorithms and tightness measures. The following section presents the architecture of the tool. Section five presents some results of workload characterization using the tool.Finally, section six presents some concluding remarks.

Pentakalos, Odysseas I.↗

High Burnup Dry Storage Cask Research and Development Project, Final Test Plan

EPRI is leading a project team to develop and implement the first five years of a Test Plan to collect data from a SNF dry storage system containing high burnup fuel.12 The Test Plan defined in this document outlines the data to be collected, and the storage system design, procedures, and licensing necessary to implement the Test Plan.13 The main goals of the proposed test are to provide confirmatory data14 for models, future SNF dry storage cask design, and to support license renewals and new licenses for ISFSIs. To provide data that is most relevant to high burnup fuel in dry storage, the design of the test storage system must mimic real conditions that high burnup SNF experiences during all stages of dry storage: loading, cask drying, inert gas backfilling, and transfer to the ISFSI for multi-year storage.15 Along with other optional modeling, SETs, and SSTs, the data collected in this Test Plan can be used to evaluate the integrity of dry storage systems and the high burnup fuel contained therein over many decades. It should be noted that the Test Plan described in this document discusses essential activities that go beyond the first five years of Test Plan implementation.16 The first five years of the Test Plan include activities up through loading the cask, initiating the data collection, and beginning the long-term storage period at the ISFSI. The Test Plan encompasses the overall project that includes activities that may not be completed until 15 or more years from now, including continued data collection, shipment of the Research Project Cask to a Fuel Examination Facility, opening the cask at the Fuel Examination Facility, and examining the high burnup fuel after the initial storage period.

high burnup, dry storage cask, final test plan, fu↗

Hybrid Power Management-Based Vehicle Architecture

Hybrid Power Management (HPM) is the integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications (s ee figure). The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The basic vehicle architecture consists of a primary power source, and possibly other power sources, that provides all power to a common energy storage system that is used to power the drive motors and vehicle accessory systems. This architecture also provides power as an emergency power system. Each component is independent, permitting it to be optimized for its intended purpose. The key element of HPM is the energy storage system. All generated power is sent to the energy storage system, and all loads derive their power from that system. This can significantly reduce the power requirement of the primary power source, while increasing the vehicle reliability. Ultracapacitors are ideal for an HPM-based energy storage system due to their exceptionally long cycle life, high reliability, high efficiency, high power density, and excellent low-temperature performance. Multiple power sources and multiple loads are easily incorporated into an HPM-based vehicle. A gas turbine is a good primary power source because of its high efficiency, high power density, long life, high reliability, and ability to operate on a wide range of fuels. An HPM controller maintains optimal control over each vehicle component. This flexible operating system can be applied to all vehicles to considerably improve vehicle efficiency, reliability, safety, security, and performance. The HPM-based vehicle architecture has many advantages over conventional vehicle architectures. Ultracapacitors have a much longer cycle life than batteries, which greatly improves system reliability, reduces life-of-system costs, and reduces environmental impact as ultracapacitors will probably never need to be replaced and disposed of. The environmentally safe ultracapacitor components reduce disposal concerns, and their recyclable nature reduces the environmental impact. High ultracapacitor power density provides high power during surges, and the ability to absorb high power during recharging. Ultracapacitors are extremely efficient in capturing recharging energy, are rugged, reliable, maintenance-free, have excellent lowtemperature characteristic, provide consistent performance over time, and promote safety as they can be left indefinitely in a safe, discharged state whereas batteries cannot.

Eichenberg, Dennis J.↗

Potential Ancillary Services Revenue for Nuclear Power Plants with Thermal Energy Storage

A large-scale thermal energy storage system could be used by a nuclear power plant to counteract price volatility from wind and solar generation. The potential revenue available to the combined system could come from wholesale energy markets as well as ancillary services markets for capacity reserves and frequency regulation. We found that ancillary services may provide up to 1/3 of the total net revenue for an energy storage system, and adding energy storage to nuclear power plants increased net revenue in all scenarios we evaluated. However, adding four energy storage systems only marginally increased net revenue compared to two systems. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Defining Safe and Efficient Interconnection Policies for Energy Storage and Solar + Storage to Improve Integration and Reduce Costs

Energy storage has a unique and pivotal role to play in the transition to a low-carbon economy because it can help the electric grid accommodate more renewable energy. However, a number of barriers currently impede the process of connecting energy storage systems to the distribution grid. The Toolkit and Guidance for the Interconnection of Energy Storage and Solar-Plus-Storage (the “BATRIES Toolkit”), which is the publication subject to this Final Technical / Scientific Report, provides vetted solutions to eight regulatory and technical barriers to the interconnection of standalone storage and solar-plus-storage systems (referred to as “energy storage”) to the distribution grid. These recommendations are based on over a year of research and analysis by utility and industry experts. The BATRIES Toolkit also includes model language that utilities and utility regulators can use to update state interconnection rules to reduce the costs and time to safely interconnect energy storage and solar-plus-storage systems. The solutions are nationally applicable and can be applied in diverse states and markets across the U.S.

14 SOLAR ENERGY↗

Integrated protonic ceramic electrochemical cell for sustainable energy economy using water-energy nexus framework

Reliance on fossil fuels will continue for the next decades even though there are global pushes away from it to mitigate the overarching climate challenge, most especially by its highest consumers and availability. While there is a hastening global shift away from fossil fuel, integrating its assets into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. Moreover, the generation of electricity from intermittent renewable sources like solar and wind has witnessed a significant surge in recent years, leading to a pressing demand for practical energy storage systems. Electrical energy storage is anticipated to play a pivotal role in the future global energy system, facilitating load-leveling operations to support the greater integration of renewable and distributed generation. Reversible electrochemical cells (RECs) offer a promising option for addressing the fossil fuel assets integration and energy storage challenges through the interconversion between electrical and chemical energy and concurrent utilizing carbon emission. In their electrolysis mode, the RECs convert electricity into durable, storable, and portable valuable chemical fuels such as syngas and methane. Conversely, the produced chemical fuels can be used as reactants in the fuel cell mode to generate electricity on demand with minimal (hydrocarbons) or zero when H2 or NH3 is used emissions. However, a challenging goal for this type of technology remains to achieve optimal operation and high roundtrip efficiencies, which has hindered the deployment of previous electrochemical cells. This dissertation demonstrates how reversible protonic ceramic electrochemical cells (RePCECs) can be integrated with fossil fuel power plants and renewable energy sources as a potential energy storage system. In this work, integrated RePCEC systems are designed and examined using computational modeling at scales to determine appropriate system configurations and operating conditions that achieve high roundtrip efficiencies. Cell level design of the PCEC is the first approach, several cells are assembled for the stack level model that is integrated into combined cycle powerplant and solar photovoltaic for the system level model. After critical literature review, this answered the operational and integration research questions proposed to address these challenges. The designed systems perform two functions, utilizing captured CO2 and storing renewable energy through co-electrolysis of steam and CO2. The co-electrolysis reaction involves endothermic water electrolysis and exothermic methanation reaction. To enhance high roundtrip efficiency, there is a need for thermal balance and management in the electrolysis mode. This involves operating the RePCEC stack under conditions that favor methane production to balance out heat needed by water electrolysis, it crucial for the RePCEC system operation. Methanation is enhanced by low temperatures. Leveraging on fabricated BCZYYb-electrolyte RePCEC, the cell model designed revealed that the optimum temperature for methane production is 450℃ at atmospheric pressure. Thus, to achieve optimum system performance, operating in the temperature range 450-525℃ is recommended at the given configuration, combining between the optimum temperature for methane production and temperature for the optimum stack roundtrip efficiency. Configuration with carbon capture system and purge stream is the optimum configuration from the seven conceptualized and evaluated. The modeling outcomes include a thermodynamic examination of integrated RePCEC systems, calibration of cell and stack level models, and steady-state simulation and integration into a 600MW combined cycle power plant retrofitted with two two-stage membrane-based carbon capture system and a wastewater treatment and recovery unit. At 100% powerplant loading, the stack and system roundtrip efficiencies are 72% and 51.37% respectively. Adding a purge stream for produced hydrogen at the system downstream improves the efficiencies to 74 and 55.48% respectively. At atmospheric pressure and 525℃, the system model suggests that a stack roundtrip of 82% is achievable, and overall system efficiency increases by reducing the energy consumption by the balance of plant components for steam generation and storage. Economic analysis of the process gives levelized cost of methane as $2.24/MMBtu lower than the conventional production route that range between $3.46/MMBtu and $9.85/MMBtu. The lifecycle analysis shows that the global warming potential for the production of methane and hydrogen from the RePCEC system is 3.83 kg CO2 eq which is lower than 9.35 kg CO2 eq emission during steam methane reforming for hydrogen production. This answered both the environmental and economic concerns in the raised research question. The proposed RePCEC configuration and analysis carried out in this dissertation to address the surge in renewable energy and challenges with PCEC technology hold significant potential in achieving large-scale energy storage while simultaneously reducing carbon emissions. These advancements, coupled with suitable governmental policies and incentive programs, have the potential to economically disrupt the natural gas industries by using RePCEC systems for methane production, thereby making them more favorable for eventual implementation and commercialization.

25 ENERGY STORAGE↗

Technical Assessment of Compressed Hydrogen Storage Tank Systems for Automotive Applications

This technical report describes DOE's assessment of the performance and cost of compressed hydrogen storage tank systems for automotive applications. The on-board performance (by Argonne National Lab) and high-volume manufacturing cost (by TIAX LLC) were estimated for compressed hydrogen storage tanks. The results were compared to DOE's 2010, 2015, and ultimate full fleet hydrogen storage targets. The Well-to-Tank (WTT) efficiency as well as the off-board performance and cost of delivering compressed hydrogen were also documented in the report.

08 HYDROGEN↗

On Secured Spinning Reserve Deployment of Energy-Limited Resources Against Contingencies

Featured with fast response abilities and high ramp rates, energy storage systems (ESS), such as pumped-storage hydropower (PSH) plants and battery storage systems (BSS), are considered as key first-responders to provide spinning reserve in response to system contingencies. However, ESSs are energy-limited resources, and their sustained spinning reserve deployment is restricted by the stored energy and available capacity. Indeed, the spinning reserve deployment against contingencies may deviate actual state-of-charge (SOC) from the scheduled value, inducing potential SOC boundary violations and non-dispatchability in later hours. This paper proposes the post-contingency operation model and the spinning reserve secure constraints to address these issues. The post-contingency operation model describes that spinning reserve from ESSs is promptly deployed when contingency occurs, and then gradually substituted by quick-start units when they are switched online. By leveraging this operation strategy, spinning reserve secure constraints in terms of SOC headrooms are adopted to guarantee its deplorability. Furthermore, a modified IEEE 118-bus system with multiple PSHs and BSSs is used to verify the proposed approach.

13 HYDRO ENERGY↗