Search NASA⌕ Search

SEARCH · Search NASA

Results for “System reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

14 SOLAR ENERGY↗

A Review of Machine Learning Applications in Power System Resilience

The integration of power electronics enabled devices and the high penetration of renewable energy drastically increase the complexity of power system operation and control. Power systems are still vulnerable to large-scale blackouts caused by extreme natural events or man-made attacks. With the recent development in artificial intelligence technique, machine learning has shown a processing ability in computational, perceptual and cognitive intelligence. It is an urgent challenge to integrate the advanced machine learning technology and large amount of real-time data from wide area measurement systems and intelligent electronic devices, in order to effectively enhance power system resilience and ensure the reliable and secure operation of power systems. Therefore, this paper aims to systematically review the existing application of machine learning methods on power system resilience enhancement, to expand the interest of researchers and scholars in this topic, and to jointly promote the application of artificial intelligence in the field of power systems.

Deep Learning↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗

Impact of High PV Penetration on Voltage Stability

Photovoltaics (PV) are becoming increasingly relevant in modern power systems. With this increase also comes reliability concerns as photovoltaics behave differently than conventional generators. One reliability concern is voltage stability. In this paper, voltage stability of the Austin area in the Electric Reliability Council of Texas (ERCOT) system is studied using dynamic models with varying levels of photovoltaic penetration. The base case is set at 0% renewable penetration. Additional cases include 15% wind penetration and up to 65% photovoltaic penetration. The study results show that voltage/var control capacity is critical to voltage stability, which PV lacks. Voltage regulation of photovoltaics may cause over-voltage and voltage collapse may be more abrupt under high regional photovoltaic penetration.

Till, Jeremy↗

Development of Non-Nuclear Microreactor Experimental Capability

Microreactors, or small, transportable reactors with a capacity of 20 MWTH or less, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions, and disaster relief zones. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. A non-nuclear system and component testing capability is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. Idaho National Laboratory has constructed the microreactor agile non-nuclear experimental test bed (MAGNET) to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support microreactor technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing.

42 ENGINEERING↗

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

Gou, Yimeng↗

Combined Heating and Power Using Microturbines in a Major Urban Hotel

This paper describes the results of a cooperative effort to install and operate a Cooling, Heating and Power (CHP) System at a major hotel in San Francisco, CA. The packaged CHP System integrated four microturbines, a double-effect absorption chiller, two fuel gas boosters, and the control hardware and software to ensure that the system operated predictably, reliably, and safely. The chiller was directly energized by the recycled hot exhaust from the microturbines, and could be configured to provide either chilled or hot water. As installed, the system was capable of providing up to 227 kW of net electrical power and 142 Refrigeration Tons (RT) of chilled water at a 59oF (15oC) ambient temperature. For the year, the CHP efficiency was 54 percent. Significant lessons learned from this test and verification project are discussed as well as measured performance and economic considerations.

42 ENGINEERING↗

Fuel Cell Backup Power System for Grid Service and Microgrid in Telecommunication Applications

This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response (DR)) as well as power for cell towers during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems can potentially enhance capabilities through information exchange with the power grid, which adds value for grid services that depend on location and time. The economic analysis focused on the potential revenue for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper includes case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs. The objective of this work is primarily on how fuel cells can become a significant part of the telecom backup power fleet to reduce system costs, environmental impact, and dependence on fossil fuels, while ensuring continuity of indispensable service for mobile users. The study identifies different fuel cell applications and nano/microgrid approaches for an extensive network of fuel cells as distributed energy resources. The possibilities of various application scenarios extend to fuel cell technologies and microgrids for reliable power supply.

30 DIRECT ENERGY CONVERSION↗

Adversarial Attacks on Deep Neural Network-based Power System Event Classification Models

Online event classification is essential to strengthening the reliability of the power transmission system. Recently, deep learning based methods have achieved great success in numerous domains such as computer vision and natural language processing. Researchers began to adopt deep learning based methods to solve the power system event identification problem and achieved effective results. However, these previous works do not consider that deep learning models are vulnerable to adversarial attacks, potentially influencing real-world applications' reliability. In this paper, we adopt several adversarial attack mechanisms by adding tailored noise signal to the input Phasor Measurement Units (PMU) time series and make the deep learning model misclassify the power system event. This numerical study discloses that current state-of-the-art deep learning based power system event classifiers are extremely vulnerable to adversarial attacks, which may jeopardize the reliability of the power transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Cell Backup Power Unit Configuration and Electricity Market Participation: A Feasibility Study

This National Renewable Energy Laboratory industry-inspired Laboratory Directed Research and Development project evaluates the feasibility and economics of using fuel cell backup power systems in cell towers to provide grid services (e.g., balancing, ancillary services, demand response). The work is intended to evaluate the integration of thousands of under-utilized, clean, efficient, and reliable fuel cell systems that are already installed in cell towers for potential grid and ancillary services.

30 DIRECT ENERGY CONVERSION↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

High-Temperature Aquifer Thermal Energy Storage (HT-ATES) Projects in Germany and the Netherlands—Review and Lessons Learned

Aquifer thermal energy storage (ATES) is a concept that can help to address heating and cooling needs through the use of the subsurface as a seasonal thermal energy storage (STES) system. Over 2800 ATES systems have been deployed with storage temperatures typically below 25 °C and only a few with higher temperatures (>40 °C), which would increase the energy density and utility of the stored thermal fluids. Until now, only a few high-temperature aquifer thermal energy storage (HT-ATES) projects have been initiated and are still in operation. These HT-ATES projects have encountered a range of technical and non-technical challenges. This study reviews ten such projects: four in Germany and six in the Netherlands. The non-technical issues include public acceptance, a lack of regulatory framework for these systems, managing overlapping uses of the subsurface, managing changes with the providers and off-takers of thermal energy, and obtaining financing to implement these projects. Common technical issues include geological factors such as incomplete characterization of the subsurface and reservoir heterogeneity; geochemical issues such as mineral scaling, corrosion, and biofouling; lower than expected thermal recovery; and issues with system design and reliability. This review highlights benefits and challenges faced by HT-ATES projects with the goal to use the lessons learned to improve the siting, design, development, and operation of such systems. Recommendations include improved initial subsurface site characterization, use of coupled process models to optimize system design and predict system performance, cascaded uses of stored thermal energy to better utilize the stored heat, monitoring networks to provide feedback on system performance, and expanded system scale to allow for continued operation even when maintenance of some system components is required. Techno-economic modeling and risk analysis could be used to optimize such HT-ATES project design and identify key factors that will affect sustained economic viability. In addition, design flexibility is important for these systems to allow for changing conditions regarding the supply and demand of thermal energy. Adopting these findings should improve the performance and reduce the risks for future HT-ATES projects worldwide.

15 - GEOTHERMAL ENERGY↗

Machine Learning in Power System Operations: Training Data

Reliability and stability of the electric grid today has depended upon operations of the grid which include the protective relay. Today, the electricity sector faces new challenges with the shift of generation resource characteristics away from the traditional “big iron” generation to inverter-based resources (IBR) which shift the physics and assumption used in grid operation and protection. These changing conditions represent new challenges for protective relays (identification of faults) and increased challenges for protection engineers (correct settings and configuration, reduction of mis-operations), both issues recognized in research and industry. Finding new approaches to reduce mis-operations in relaying and new approaches to fault identification is critical to grid operations. Using today’s modern technology of embedded systems, edge computing, machine learning (ML), and communications we can help address challenges and augment and improve on existing power system operations methodologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Test based reliability assessment method for a safety critical software in reactor protection system - 284

Digitalization of the instrumentation and control systems in nuclear power plant entails some new features which do not exist in analog systems. When the new features are applied in safety critical systems, the risk stemming from them should be quantified properly to assure the reliability of the entire power plant. Among the new features, software is considered as the most important factor because it can cause common cause failure to many redundant systems. Therefore, in this work, a test based reliability assessment method for a safety-critical software is developed. An output of a software is determined by not only inputs but also the internal state of the software at the time. In the case of safety critical software developed for usage in nuclear power plant, it is possible to directly investigate probable internal states thanks to detailed design specification and programing features, and the probable inputs also can be identified based on the physical linearity of each process parameter and hardware characteristics related to data acquisition. In this work, a development method for practical exhaustive test case consisting of investigation of internal state and probable input sets to a specific internal state are suggested. In addition to this, software logic simulator for execution of software logic test and the reliability quantification method based on the test result are developed. The feasibility of the suggested method is demonstrated via a case study. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PVDeg: Enhancing Usability and AI-Driven Multi-Mechanism Degradation Modeling

PVDeg version 0.7.0, released in December 2025, introduced major enhancements to improve usability and performance. This update reorganized tutorials and tool notebooks to create a more intuitive experience, enabling users to easily follow and adapt workflows for their specific analyses. In addition to structural improvements, both the notebooks and core logic underwent significant optimization for efficiency, robustness, and style. These refinements were supported by new testing frameworks built on nbval and pytest, adherence to PEP8 standards, and extensive code refactoring, which collectively simplify onboarding for new developers. Looking ahead, version 0.8.0 will deliver advanced AI-driven capabilities. The primary focus is to further develop and automate the degradation workflow, designed to analyze PV module degradation across diverse locations and system configurations. By integrating large language models (LLMs) to scan literature and compile a comprehensive database of materials and degradation rates, this feature will enable modeling of multiple materials and mechanisms within a single, streamlined workflow. Users will be able to evaluate degradation impacts on different system architectures under varying environmental conditions, facilitating informed decisions on bill-of-materials optimization for specific deployment scenarios. These advancements position PVDeg as a powerful, user-friendly tool for accelerating PV reliability research and system design.

14 SOLAR ENERGY↗

A Mechanistic Reliability Assessment of RVACS and Metal Fuel Inherent Reactivity Feedbacks

GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory (Argonne) participated in a two year collaboration to modernize and update the probabilistic risk assessment (PRA) for the PRISM sodium fast reactor. At a high level, the primary outcome of the project was the development of a next-generation PRA that is intended to enable risk-informed prioritization of safety- and reliability-focused research and development. A central Argonne task during this project was a reliability assessment of passive safety systems, which included the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedbacks of the metal fuel core. Both systems were examined utilizing a methodology derived from the Reliability Method for Passive Safety Functions (RMPS), with an emphasis on developing success criteria based on mechanistic system modeling while also maintaining consistency with the Fuel Damage Categories (FDCs) of the mechanistic source term assessment. This paper provides an overview of the reliability analyses of both systems, including highlights of the FMEAs, the construction of best-estimate models, uncertain parameter screening and propagation, and the quantification of system failure probability. In particular, special focus is given to the methodologies to perform the analysis of uncertainty propagation and the determination of the likelihood of violating FDC limits. Additionally, important lessons learned are also reviewed, such as optimal sampling methodologies for the discovery of low likelihood failure events and strategies for the combined treatment of aleatory and epistemic uncertainties.

Grabaskas, David↗