Model-Driven Test Generation of Distributed Systems

This report describes a novel test generation technique for distributed systems. Utilizing formal models and formal verification tools, spe cifically the Symbolic Analysis Laboratory (SAL) tool-suite from SRI, we present techniques to generate concurrent test vectors for distrib uted systems. These are initially explored within an informal test validation context and later extended to achieve full MC/DC coverage of the TTEthernet protocol operating within a system-centric context.

Easwaran, Arvind↗

Evaluation of Long Term Microbial Regrowth in Slosh Water Tanks From the International Space Station

The NASA Launch Services Program (LSP) maintained the SPHERES-Slosh experiment aboard the International Space Station (ISS) between 2013 and 2019. The purpose of the Slosh experiment was to examine how liquids move inside fuel tanks in a microgravity environment. These tanks were similar to water storage tanks planned for use aboard future space systems, where large dormant periods between crew-use will provide similar conditions for biological growth or chemical leaching. The water within the SLOSH tanks remained undisturbed for over five years after testing concluded, providing a unique sample for stored water under microgravity conditions without prior protocols for microbial control such as sterilization or addition of biocides. The Slosh storage tanks were returned to Kennedy Space Center (KSC) aboard SpaceX CRS-18 mission in November 2019. Upon return of the tanks, the water within each tank was analyzed to determine how the water chemistry and biology changed during its tenure in microgravity. The data obtained and described within this publication provided a basis and reasoning for planning water storage and purification treatment methods aboard ISS, Gateway, and future space habitats. Results demonstrated that low microbial concentrations were present within the water, as expected since no biocide treatment was employed, yet no extensive biofilm formation was observed after 5 years even in the presence of microbial food sources such as the polycarbonate structure and food color additives. This experimentation demonstrates that future biofilm studies should be performed on this type of experimental setup with proper controls aboard ISS to examine microbial regrowth to improve microbial control within space water systems.

Luke B. Roberson↗

Exploration Medical Capability - Advancing Medical System Design and Risk-Informed Decision Making for Deep Space Exploration

BACKGROUND: Within NASA’s Human Research Program, the Exploration Medical Capability (ExMC) Element has three primary focus areas: clinical and scientific research, systems engineering and trade space analysis, and technology development and demonstrations. These focus areas feed into the overarching goal of enabling progressively Earth-Independent Medical Operations (EIMO), a new paradigm that will be necessary for future Artemis and Mars medical and vehicle systems. This EIMO end state aligns with NASA’s Moon to Mars Objectives, which clearly outline the need for NASA deep space exploration missions to reduce their reliance upon Earth and become increasingly autonomous, in preparation for the first human Mars mission. OVERVIEW: To advance exploration medical systems and ultimately, integrated crew health and performance systems, ExMC’s portfolio includes: funding ground development & testing of novel medical capabilities; creation of new approaches for the development of medical protocols and procedures; deployment of innovative technologies into analog environments; technology demonstrations in spaceflight; and eventual transition to operations of new capabilities for deep space exploration missions. The portfolio also includes: pharmaceutical research targeting stability, pharmacokinetics, and pharmacodynamics; integrated data architectures and clinical decision support tools; and systems engineering and trade space analysis tools to assist NASA in the development of future medical system models as well as the medical system requirements that can serve as a foundation for deep space exploration missions. All of these investments are done in a collaborative and coordinated fashion with other NASA stakeholders, such as the Environmental Control and Life Support Systems – Crew Health and Performance System Capability Leadership Team and the Health and Medical Technical Authority. DISCUSSION: In this presentation, ExMC will provide an overview of our work from across our portfolio, all of which will inform future EIMO efforts at NASA. ExMC’s research and development investments are targeted to reduce the human system risks associated with deep space exploration to the Moon and Mars.

Kris Lehnhardt↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adsorbent materials development and testing for the extraction of uranium from seawater

The extraction of uranium from seawater has been the focus of a research project for the U.S. Department of Energy to develop amidoxime functional group adsorbents using radiation-induced graphing on polymer-based fiber materials and subsequent chemical conversion of the radical sites to form the desired adsorbent material. Materials with promising uranium adsorption capacities were prepared through a series of parametric studies on radiation dose, time, temperature, graphing solutions, and properties of the base polymer materials. A laboratory screening protocol was developed to determine the uranium adsorption capacity to identify the most promising candidate materials for seawater testing. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mobile/Modular BSL-4 Containment Facilities Integrated into a Curation Receiving Laboratory for Restricted Earth Return Missions

NASA robotic sample return missions designated Category V Restricted Earth Return by the NASA Planetary Protection (PP) Office require sample containment and biohazard testing upon return to Earth. Since the 1960s, sample containment from an unknown extraterrestrial biohazard have been related to the highest containment standards and protocols known to modern science. Today, this is Biosafety Level (BSL) 4 containment. In the U.S., the Biosafety in Microbiological and Biomedical Laboratories publication authored by the U.S. Department of Health and Human Services (HHS): Public Health Service, Centers for Disease Control and Prevention, and the National Institutes of Health houses the primary recommendations, standards, and design requirements for all BSL labs. Past mission concept studies for constructing a NASA Curation Receiving Laboratory with an integrated BSL-4 quarantine and biohazard testing facility have been estimated in the hundreds of millions of dollars (USD). As an alternative option, we have conducted a trade study for constructing a mobile and/or modular sample containment laboratory that would meet all BSL-4 and planetary protection standards and protocols at a fraction of the cost. Mobile and modular BSL-2 and 3 facilities have been successfully constructed and deployed world-wide for government testing of pathogens and pharmaceutical production. Our study showed that a modular BSL-4 construction could result in ~ 90% cost reduction when compared to traditional BSL-4 construction methods without compromising the preservation of the samples or Earth. For the design/construction requirements of a mobile/modular BSL-4 containment, we used the established HHS document standards and protocols for manipulation of agents in Class III Biosafety Cabinets (BSC; i.e., negative pressure gloveboxes) that are currently followed in operational BSL-4 facilities in the U.S.

Calaway, Michael J.↗

J-integral measured from experimental torque load versus torque-ends rotation angle obtained from a spiral notch torsion test

In this work, Spiral Notch Torsion Test (SNTT) was developed to measure the intrinsic fracture toughness of structural materials using small specimens. The SNTT system operates by applying pure torsion to cylindrical specimens with a notch line that spirals around the specimen at a 45° pitch. 3-D finite-element analysis has been used to estimate the fracture toughness obtained from SNTT test specimen with 3-D non-coplanar crack front. Furthermore, here a newly developed SNTT protocol to estimate J-integral directly from the experimental torque load versus torque-ends rotation angle trend curve without the aid of 3-D finite element analyses is presented and its applicability is illustrated by applying it for the evaluation of fracture toughness of SS304/308 weldment. The estimated JQ’ for the SS304/308 weld is 144.2 kJ/m2, which is consistent with that obtained from CT specimen.

36 MATERIALS SCIENCE↗

CFD Modeling and Image Analysis of Exhaled Aerosols due to a Growing Bronchial Tumor: towards Non-Invasive Diagnosis and Treatment of Respiratory Obstructive Diseases

Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure vari-ations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treat the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagran-gian tracking approach were used to model respiratory airflows and aerosol dynamics. Respira-tions of tracer aerosols of 1 µm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug de-livery protocol.

Aerosol breath test↗

TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regions were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.

60 APPLIED LIFE SCIENCES↗

Lighting Automation - Flying an Earthlike Habitat

Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.

Clark, Tori A.↗

Lighting Automation Flying an Earthlike Habitat

Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.

Clark, Toni A.↗

Spatial Cognitive Performance During Adaptation to Conflicting Tilt-Translation Stimuli as a Sensorimotor Spaceflight Analog

The need to resolve new patterns of sensory feedback in altered gravitoinertial environments requires cognitive processes to develop appropriate reference frames for spatial orientation awareness. The purpose of this study was to examine deficits in spatial cognitive performance during adaptation to conflicting tilt-translation stimuli. Fourteen subjects were tilted within a lighted enclosure that simultaneously translated at one of 3 frequencies. Tilt and translation motion was synchronized to maintain the resultant gravitoinertial force aligned with the longitudinal body axis, resulting in a mismatch analogous to spaceflight in which the canals and vision signal tilt while the otoliths do not. Changes in performance on different spatial cognitive tasks were compared 1) without motion, 2) with tilt motion alone (pitch at 0.15, 0.3 and 0.6 Hz or roll at 0.3 Hz), and 3) with conflicting tilt-translation motion. The adaptation paradigm was continued for up to 30 min or until the onset of nausea. The order of the adaptation conditions were counter-balanced across 4 different test sessions. There was a significant effect of stimulus frequency on both motion sickness and spatial cognitive performance. Only 3 of 14 were able to complete the full 30 min protocol at 0.15 Hz, while 7 of 14 completed 0.3 Hz and 13 of 14 completed 0.6 Hz. There were no changes in simple visual-spatial cognitive tests, e.g., mental rotation or match-to-sample. There were significant deficits during 0.15 Hz adaptation in both accuracy and reaction time during a spatial reference task in which subjects are asked to identify a match of a 3D reoriented cube assemblage. Our results are consistent with antidotal reports of cognitive impairment that are common during sensorimotor adaptation with G-transitions. We conclude that these cognitive deficits stem from the ambiguity of spatial reference frames for central processing of inertial motion cues.

Kayanickupuram, A. J.↗

Prospective Study of Hippocampal-Sparing Prophylactic Cranial Irradiation in Limited-Stage Small Cell Lung Cancer

Purpose: To prospectively evaluate cognitive function and intracranial failure patterns after hippocampal-sparing prophylactic cranial irradiation (PCI) for limited-stage small cell lung cancer (SCLC). Methods and Materials: Adults with limited-stage SCLC, achieving a complete response to chemoradiotherapy and no brain metastases, were eligible. Patients received PCI 25 Gy/10 fractions, with a mean hippocampal dose limited to <8 Gy and ≥90% of the brain receiving 90% of the prescription. A diverse battery of neuropsychological testing was performed at baseline and 6 and 12 months after PCI. Brain MRI scans were performed at baseline and 6, 12, 18, and 24 months. The primary endpoint was memory measured by the Hopkins Verbal Learning Test-Revised Delayed Recall at 6 months after PCI. The 25-Gy arm of Radiation Therapy Oncology Group protocol 0212 was used as a reference of potential efficacy. Development of intracranial metastases was recorded. Overall survival and progression-free survival were estimated using the Kaplan-Meier method. Results: Eight men and 12 women with a median age of 61 years enrolled. Two-year overall survival was 88% (95% confidence interval 68%-100%). There was no significant decline in performance between baseline and 6 or 12 months for any of the tests. The association between baseline intelligence quotient and change in performance on testing was not significant. Magnetic resonance imaging revealed asymptomatic brain metastases at a cumulative rate of 20%, with no concurrent extracranial progression. Two patients developed a metastasis in the under-dosed region. Neither involved the dentate gyrus, but 1 involved the avoidance region. Both patients concurrently developed additional metastasis in fully treated brain regions. There were 2 neurologic deaths. Conclusions: This prospective study suggests a potential benefit of hippocampal sparing in limiting the neuropsychological sequelae of brain radiation, but with a risk of failures in the spared region. These data strongly support continued enrollment on ongoing cooperative group randomized trials. Clinical Trials registration number: (NCT01797159).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

National Campaign (NC)-1 Strategic Conflict Management Simulation (X4) Final Report

Urban Air Mobility (UAM) enables highly automated, cooperative, passenger or cargo-carrying air transportation services in and around urban areas. UAM is a subset of the Advanced Air Mobility (AAM) concept under development by the National Aeronautics and Space Administration (NASA), the Federal Aviation Administration (FAA), and industry. The Strategic Conflict Management (SCM) Simulation, dubbed “X4”, was conducted between July 2021 and June 2022 by NASA with the FAA and industry to evolve the Provider of Services for UAM (PSU) that will be needed to ensure initial UAM operations can scale in the National Airspace System (NAS). The FAA UAM Concept of Operations (ConOps) v1 [1] served as an initial guiding document for the X4 airspace management system design to ensure the architecture supports testing of services provided by third-party service providers. To that end, the X4 architecture leveraged concepts and technologies developed for Unmanned Aircraft System (UAS) Traffic Management (UTM) while also developing and testing new capabilities and services needed for UAM. The architecture included an initial prototype of the FAA-Industry Exchange Protocol (FIDXP), third-party services such as the PSUs, and Discovery and Synchronization Service (DSS), and other new services such as Demand-Capacity Balancing (DCB) to facilitate UAM strategic conflict management. During X4, NASA led discussions and collaborated with seven industry airspace partners to develop initial airspace management concepts for UAM that drove what would be tested and evaluated during the simulations. The initial capabilities defined for PSU leveraged UTM UAS Service Supplier (USS) as a starting point and evolved to meet UAM requirements. These discussions were also an opportunity for NASA to collaborate with industry to develop a set of initial Community-Based Rules (CBRs). These CBRs enabled how UAM traffic would be cooperatively managed among UAM operators. The collaborative, iterative process of developing CBRs with industry during X4 provided insight into the challenges involved and identified the need for a suitable and effective forum for future CBR development. In parallel with these discussions, NASA conducted a series of seven software sprints and two collaborative simulations with the airspace partners that built up in complexity. Over the course of the year, all seven partners successfully completed all the sprints by demonstrating the required capabilities. They also participated in the two collaborative simulations to demonstrate how multiple PSUs could work together in a collaborative, more complex environment with higher traffic density. The X4 simulation accomplished NASA's objectives and helped advance the development of the seven participating PSUs. The lessons learned provided insight into key elements of the UAM Notional Architecture from the FAA ConOps v1 [1] and UTM technologies when applied to UAM: - Having a Concept of Use (ConUse) defined prior to the activity would accelerate the time and effort from concept development to testing. - While the UAM Notional Architecture provided a starting point for a federated architecture that support services provided by third-party providers, the USS and PSU differed in their capability definitions for operational intent submission and sharing, conformance monitoring, airspace authorization, strategic conflict management, airspace constraints and dynamic replanning. - While existing DSS developed for UTM provided a way for PSU and other UAM services (such as DCB) to discover relevant operations from each other, additional complexity and challenges were found during X4 testing and illuminated the need for a more suitable solution for UAM. Industry can leverage the results of this demonstration to accelerate UAM requirements, CBRs, and standards development. The FAA and other government municipalities and agencies will be able to leverage results to inform future policies and identify additional gaps that require further analysis, moving toward operationalization of UAM.

Urban Air Mobility↗

Resistance exercise countermeasures for space flight: implications of training specificity

While resistance exercise should be a logical choice for prevention of strength loss during unloading, the principle of training specificity cannot be overlooked. Our purpose was to explore training specificity in describing the effect of our constant load exercise countermeasure on isokinetic strength performance. Twelve healthy men (mean +/- SD: 28.0 +/- 5.2 years, 179.4 +/- 3.9 cm, 77.5 +/- 13.6 kg) were randomly assigned to no exercise or resistance exercise (REX) during 14 days of bed rest. REX performed five sets of leg press exercise to volitional fatigue (6-10 repetitions) every other day. Unilateral isokinetic concentric-eccentric knee extension testing performed before and on day 15 prior to reambulation included torque-velocity and power-velocity relationships at four velocities (0.52, 1.75, 2.97, and 4.19 rad s-1), torque-position relationship, and contractile work capacity (10 repetitions at 1.05 rad s-1). Two (group) x 2 (time) ANOVA revealed no group x time interactions; thus, groups were combined. Across velocities, angle-specific torque fell 18% and average power fell 20% (p < 0.05). No velocity x time or mode (concentric/eccentric) x time interactions were noted. Torque x position decreased on average 24% (p < 0.05). Total contractile work dropped 27% (p < 0.05). Results indicate bed rest induces rapid and marked reductions in strength and our constant load resistance training protocol did not prevent isokinetic strength losses. Differences between closed-chain training and open-chain testing may explain the lack of protection.

Randomized Controlled Trial↗

No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark Credentialing Results for NRG-BR001: The First National Cancer Institute-Sponsored Trial of Stereotactic Body Radiation Therapy for Multiple Metastases

Purpose: The NRG-BR001 trial is the first National Cancer Institute–sponsored trial to treat multiple (range 2-4) extracranial metastases with stereotactic body radiation therapy. Benchmark credentialing is required to ensure adherence to this complex protocol, in particular, for metastases in close proximity. The present report summarizes the dosimetric results and approval rates. Methods and Materials: The benchmark used anonymized data from a patient with bilateral adrenal metastases, separated by <5 cm of normal tissue. Because the planning target volume (PTV) overlaps with organs at risk (OARs), institutions must use the planning priority guidelines to balance PTV coverage (45 Gy in 3 fractions) against OAR sparing. Submitted plans were processed by the Imaging and Radiation Oncology Core and assessed by the protocol co-chairs by comparing the doses to targets, OARs, and conformity metrics using nonparametric tests. Results: Of 63 benchmarks submitted through October 2015, 94% were approved, with 51% approved at the first attempt. Most used volumetric arc therapy (VMAT) (78%), a single plan for both PTVs (90%), and prioritized the PTV over the stomach (75%). The median dose to 95% of the volume was 44.8 ± 1.0 Gy and 44.9 ± 1.0 Gy for the right and left PTV, respectively. The median dose to 0.03 cm{sup 3} was 14.2 ± 2.2 Gy to the spinal cord and 46.5 ± 3.1 Gy to the stomach. Plans that spared the stomach significantly reduced the dose to the left PTV and stomach. Conformity metrics were significantly better for single plans that simultaneously treated both PTVs with VMAT, intensity modulated radiation therapy, or 3-dimensional conformal radiation therapy compared with separate plans. No significant differences existed in the dose at 2 cm from the PTVs. Conclusions: Although most plans used VMAT, the range of conformity and dose falloff was large. The decision to prioritize either OARs or PTV coverage varied considerably, suggesting that the toxicity outcomes in the trial could be affected. Several benchmarks met the dose-volume histogram metrics but produced unacceptable plans owing to low conformity. Dissemination of a frequently-asked-questions document improved the approval rate at the first attempt. Benchmark credentialing was found to be a valuable tool for educating institutions about the protocol requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EVA Swab Kit: Tools and Techniques for Collecting Aseptic Samples from Crewed Space Missions

Introduction: When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed spacecraft meet planetary protection requirements—and to protect our science from human contamination—we'll need to assess and verify whether micro-organisms may be leaking/venting from our spacesuits. This requires collecting samples under Extravehicular Activity (EVA) conditions. Detailed, systematic research on forward contamination from robotic spacecraft has been steadily progressing since the Viking missions, but systematic studies of contamination from space suits has not been conducted in many years. The modern EMU (Extravehicular Mobility Unit) suit used by NASA is designed to leak at rates as high as 100 cc/min. Before humans land on Mars there is a critical need to understand the types and quantities of microbes that could be introduced via space suits. The Human Forward Contamination Assessment team at NASA’s Johnson Space Center (JSC) has developed a prototype EVA swab tool [1,2,3,4] designed for use in space to sample cleaned and uncleaned space suits to determine the present day microbial load and eventually the rate of leakage. The ability to assess microbial leakage early in advanced space suit and life support system design cycles will help avoid costly hardware redesign later. Test Objectives: The primary objective of EMU testing was to characterize the type of micro-organisms typically found on or near selected suit pressure joints under suit differential pressure conditions. Most human-borne microbes can fit through a 0.5 to 1.0 µm gap. Knowing which joints are more likely to leak will inform hardware design decisions. Knowing which types of micro-organisms may leak from EVA suits provides a basis for subsequent studies to characterize the viability of those organisms under destination conditions, as well as how far they might spread through natural or human-influenced processes. That data, in turn, will inform exploration mission operations and hardware design. The secondary objective of testing was to evaluate the interface between a fully suited test subject and the EVA swab tool at vacuum. Bulky EVA suits can restrict movement and limit visibility through the helmet visor. Fully suited testing is important for identifying tool design issues prior to flight. At exploration destinations, such as Mars, suited crew may be required to periodically sample their suits as part of an environmental monitoring protocol. Suit Microbial Sampling Results: This report details results of microbial swabs collected from current flight suit configurations worn by crew members assigned to upcoming ISS expedition missions as well as swabs collected from prototype suits intended for use on the Orion spacecraft. These tests were intended to characterize the types of contaminants found on flight suits under current, typical handling conditions. No attempt was made to change suit handling procedures, provide additional sterilization, or to limit typical potential contaminant sources. Using culture based techniques, we cultivated 235 CFU (colony forming units) comprised of 26 bacterial species and one fungal species on the outside of the suits. The fungal species and 14 of the bacterial species were unique to the suit surfaces and were not detected in any of the background samples collected within the chambers. We sequenced 755,434 ribosomal fragments on all of the suit surfaces from swab samples. 557,016 of these sequences represent DNA that survived at least 4 hours at vacuum. These sequences formed 2,464 OTU's (Operational Taxonomic Units, 97% similarity) showing low diversity in the samples. The most abundant sequences that survived vacuum belong to the genera Staphyloccocus, Ralstona, Bacillus and Rhodobacter all of which are common to the human microbiome. [5] See Danko et al., (2021) for more complete details of these first analyses. Further analysis of EVA suit materials with respect to the efficacy of various cleaning protocols and engineered containment solutions is planned to inform suit design for NASA’s Artemis Moon to Mars program crew testing. Swab Tool Function Results: The kit was demonstrated for fit and function in suited subject vacuum tests to determine how well the tool worked as an aseptic microbial sampling device as well as to identify any design elements that could be upgraded for EVA task specific improvement. It was found that sample acquisition efficacy could be enhanced by redesign of the sample canister to end-effector interface. Several modifications of the sample caddy assemblies to optimize EVA safety and functionality were also identified. Consequently, fabrication of the redesigned sample canister to end-effector assembly interfaces and and the sample caddy assemblies are required. Fabrication of sixteen flight sample canister assemblies (8 per each of two EVA Swab Kits) and two sample caddy assemblies are in process to be followed by hardware testing and certification to produce two flight-certified EVA Swab Kits for transport to ISS no earlier than summer of 2022. Sampling Strategy: The International Space Station is an ideal testbed for systematic studies of contamination from crewed vehicles since it has been continuously occupied for 20 years and exposed to non-terrestrial conditions. We will sample the exterior of the ISS during EVA using a purpose-built swab tool capable of maintaining sterility while undergoing temperature changes from -151 to +121°C under hard vacuum. Prior to each EVA, the project team will work with ISS mission managers to identify precise sampling locations, which will vary by EVA based on the translation paths and worksites scheduled for that particular EVA. Ideally, translation path handrails and areas near ECLSS (Environmental Control and Life Support System) external vent openings on a spacecraft would be assessed. There are currently more than a dozen ECLSS external vents on the ISS. Some are connected to systems that vent waste products, while others are intended to equalize cabin pressure. As EVA opportunity allows, microbial samples from any of these external vents would provide a valuable data point, though some will be more useful than others. Four criteria have been identified to help prioritize sampling sites near vents: • EVA Accessibility: To minimize cost, it is desired to piggy-back onto a planned EVA. Therefore, the sampling location must be readily accessible by an EVA crew • Type of Vented Products: Vent products that have been in direct contact with crew, such as cabin air, are more likely to contain microorganisms than vent products associated with isolated systems, such as experiment module combustion products. • Mass of Vented Products: Higher-flow vents are more likely to contain detectible levels of microbial contaminants than lower-flow vents. • Local Environment: Sample locations with relatively benign local conditions, such as warm surfaces shielded from direct ultraviolet (UV) radiation exposure, may be more likely to support microbial growth than locations with harsher local environmental conditions. Because EVA accessibility is the most important criteria, the proposal team worked with an astronaut and flight controllers using the Dynamic Onboard Ubiquitous Graphics (DOUG) tool. The DOUG virtual environment allows an operator to “fly” around the current ISS vehicle configuration to assess EVA translation paths, attach points, and keep-out zones. While analysis on station or rapid return to Earth would be preferable, samples collected from the exterior of the ISS have already been exposed to temperature variations between -157 and +121 °C as well as hard vacuum. Therefore, they should be fairly stable and robust. We hypothesize that samples collected from the ISS exterior could be stored for up to 6 months at -80°C without degradation. Sample canisters will be returned to Earth while frozen at -80°C for analysis, and sterilized canisters can be re-flown back to ISS to support additional sampling opportunities Relevance to NASA Exploration Objectives: These data will allow us to identify new or improved methods, technologies, and procedures for spacecraft sterilization and leakage mitigation to minimize the amount of contamination introduced to the environment by human explorers. This work is funded by NASA research grant: NNH18ZDA001N-PPR References: [1] Bell, M.S. et al. (2015) LPS XLVI, Abst. #1832 [2] Rucker et al. (2018) 42nd COSPAR (PPP.3) [3] Bell, M.S. et al. (2019) Mars Extant Life Conference, Abst. #5096.[4] Bell, M.S. et al., (2020) 43rd COSPAR (BO.2).[5] Danko D, et.al.,(2021)Front.Microbiol.12:608478.