Search NASA⌕ Search

SEARCH · Search NASA

Results for “User Guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Evidence-based indicator approach to guide preliminary environmental impact assessments of hydropower development

Global expansion of hydropower resources has increased in recent years to meet growing energy demands and fill worldwide gaps in electricity supply. However, hydropower induces significant environmental impacts on river ecosystems - impacts that are addressed through environmental impact assessment (EIA) processes. The need for effective EIA processes is increasing as environmental regulations are either stressed in developing countries undertaking rapid expansion of hydropower capacity or time- and resource-intensive in developed countries. Part of the challenge in implementing EIAs lies in reaching a consensus among stakeholders regarding the most important environmental factors as the focus of impact studies. To help address this gap, we developed a weight-of-evidence approach (and toolkit) as a preliminary and coarse assessment of the most relevant impacts of hydropower on primary components of the river ecosystem, as identified using river function indicators. Through a science-based questionnaire and predictive model, users identify which environmental indicators may be impacted during hydropower development as well as those indicators that have the highest levels of uncertainty and require further investigation. Furthermore, an assessment tool visualizes inter-dependent indicator relationships, which help formulate hypotheses about causal relationships explored through environmental studies. We apply these tools to four existing hydropower projects and one hypothetical new hydropower project of varying sizes and environmental contexts. We observed consistencies between the output of our tools and the Federal Energy Regulatory Commission licensing process (inclusive of EIAs) but also important differences arising from holistic scientific evaluations (our toolkit) versus regulatory policies. The tools presented herein are aimed at increasing the efficiency of the EIA processes that engender environmental studies without loss of rigor or transparency of rationale necessary for understanding, considering, and mitigating the environmental consequences of hydropower.

54 ENVIRONMENTAL SCIENCES↗

The Bioverse API and Web Application

The Bioverse is a framework for creating, warehousing and presenting biological information based on hierarchical levels of organisation. The framework is guided by a deeper philosophy of desiring to represent all relationships between all components of biological systems towards the goal of a wholistic picture of organismal biology. Data from various sources is combined into a single repository and a uniform interface is exposed to access it. The power of the approach of the Bioverse is that, due to its inclusive nature, patterns emerge from the acquired data and new predictions are made. The implementation of this repository (beginning with acquisition of source data, processing in a pipeline and concluding with storage in a relational database) and interfaces to the data contained in it, from a programmatic application interface to a user friendly web application, are discussed

59 BASIC BIOLOGICAL SCIENCES↗

A knowledge brokerage approach for assessing the impacts of the setting up young farmers policy measure in Greece

This study explores Knowledge Brokerage (KB) aspects of an ex-post Impact Assessment (IA) for the Rural Development Programme (RDP) measure of setting up young farmers, under the Common Agricultural Policy (CAP), at the regional level in Northern Greece. The measure supports the entry of young farmers in agriculture by moving land from older to younger farmers. The aim of the study was to test a set of KB tools for improving the interaction between researchers and policy makers. Our analysis mainly focused on a suite of IA Support Modules to guide practitioners, and on a technical tool kit, a web-based contextualisation platform, to support the IA of the specific test case. Offering a structured approach towards IA, both the Support Modules and LIAISE-KIT allow framing the context, organisation, scheduling and method selection in the light of KB objectives. The evaluation of how IA Support Modules influence the Science Policy Interface (SPI), in the case of the ex-post assessment, demonstrated the high relevance of KB activities for facilitating the interaction between researchers and regional policy makers. The assessment bridges the gap between knowledge producers developing scientific output to be applied in a specific context, and knowledge users, who want clear messages regarding the policy challenges they face. Other conclusions include the need for specific guidelines and training for knowledge users, especially with regard to the use of tools. According to our findings, a consequent application of KB activities is a crucial pre-condition for successfully implementing IAs in future RDP measures.

54 ENVIRONMENTAL SCIENCES↗

On Performance Prediction of Big Data Transfer in High-performance Networks

Big data generated by large-scale scientific and industrial applications need to be transferred between different geographical locations for remote storage, processing, and analysis. High-speed dedicated connections provisioned in High-performance Networks (HPNs) are increasingly utilized to carry out such big data transfer. HPN management highly relies on an important capability of performance (mainly throughput) prediction to reserve sufficient bandwidth and meanwhile avoid over-provisioning that may result in unnecessary resource waste. This capability is critical to improving the resource (mainly bandwidth) utilization of dedicated connections and meeting various user requests for data transfer. Conventional methods conduct performance prediction by fitting prior observed transfer history with predefined loss functions, without considering unobservable latent factors such as competing loads on end hosts. Such latent factors also have a significant impact on the application-level data transfer performance, which may result in an inaccurate prediction model. In this paper, we first investigate the impact of latent factors and propose a clustering-based method to eliminate their negative impact on performance prediction. We then develop a robust machine learning-based performance predictor by: i) incorporating the proposed latent factor elimination method into data preprocessing, and ii) adopting a customized domain guided loss function. Extensive experimental results show that our predictor achieves significantly higher prediction accuracy than several other state-of-the-art methods.

Liu, Wuji↗

Guided construction of single cell reference for human and mouse lung

Accurate cell type identification is a key and rate-limiting step in single-cell data analysis. Single-cell references with comprehensive cell types, reproducible and functionally validated cell identities, and common nomenclatures are much needed by the research community for automated cell type annotation, data integration, and data sharing. Here, we develop a computational pipeline utilizing the LungMAP CellCards as a dictionary to consolidate single-cell transcriptomic datasets of 104 human lungs and 17 mouse lung samples to construct LungMAP single-cell reference (CellRef) for both normal human and mouse lungs. CellRefs define 48 human and 40 mouse lung cell types catalogued from diverse anatomic locations and developmental time points. We demonstrate the accuracy and stability of LungMAP CellRefs and their utility for automated cell type annotation of both normal and diseased lungs using multiple independent methods and testing data. We develop user-friendly web interfaces for easy access and maximal utilization of the LungMAP CellRefs.

59 BASIC BIOLOGICAL SCIENCES↗

A2Cloud‐RF : A random forest based statistical framework to guide resource selection for high‐performance scientific computing on the cloud

Summary This article proposes a random‐forest based A2Cloud framework to match scientific applications with Cloud providers and their instances for high performance. The framework leverages four engines for this task: PERF engine, Cloud trace engine, A2Cloud‐ext engine, and the random forest classifier (RFC) engine. The PERF engine profiles the application to obtain performance characteristics, including the number of single‐precision (SP) floating‐point operations (FLOPs), double‐precision (DP) FLOPs, x87 operations, memory accesses, and disk accesses. The Cloud trace engine obtains the corresponding performance characteristics of the selected Cloud instances including: SP floating point operations per second (FLOPS), DP FLOPS, x87 operations per second, memory bandwidth, and disk bandwidth. The A2Cloud‐ext engine uses the application and Cloud instance characteristics to generate objective scores that represent the application‐to‐Cloud match. The RFC engine uses these objective scores to generate two types of random forests to assist users with rapid analysis: application‐specific random forests (ARF) and application‐class based random forests. The ARF consider only the input application's characteristics to generate a random forest and provide numerical ratings to the selected Cloud instances. To generate the application‐class based random forests, the RFC engine downloads the application profiles and scores of previously tested applications that perform similar to the input application. Using these data, the RFC engine creates a random forest for instance recommendation. We exhaustively test this framework using eight real‐world applications across 12 instances from different Cloud providers. Our tests show significant statistical agreement between the instance ratings given by the framework and the ratings obtained via actual Cloud executions.

Samuel, David↗

Visualizing nD Point Clouds as Topological Landscape Profiles to Guide Local Data Analysis

Analyzing high-dimensional point clouds is a classical challenge in visual analytics. Traditional techniques, such as projections or axis-based techniques, suffer from projection artifacts, occlusion, and visual complexity.We propose to split data analysis into two parts to address these shortcomings. First, a structural overview phase abstracts data by its density distribution. This phase performs topological analysis to support accurate and non-overlapping presentation of the high-dimensional cluster structure as a topological landscape profile. Utilizing a landscape metaphor, it presents clusters and their nesting as hills whose height, width, and shape reflect cluster coherence, size, and stability, respectively. A second local analysis phase utilizes this global structural knowledge to select individual clusters or point sets for further, localized data analysis. Focusing on structural entities significantly reduces visual clutter in established geometric visualizations and permits a clearer, more thorough data analysis. In conclusion, this analysis complements the global topological perspective and enables the user to study subspaces or geometric properties, such as shape.

97 MATHEMATICS AND COMPUTING↗

Demystifying asynchronous I/O Interference in HPC applications

With increasing complexity of HPC workflows, data management services need to perform expensive I/O operations asynchronously in the background, aiming to overlap the I/O with the application runtime. However, this may cause interference due to competition for resources: CPU, memory/network bandwidth. The advent of multi-core architectures has exacerbated this problem, as many I/O operations are issued concurrently, thereby competing not only with the application but also among themselves. Furthermore, the interference patterns can dynamically change as a response to variations in application behavior and I/O subsystems (e.g. multiple users sharing a parallel file system). Without a thorough understanding, I/O operations may perform suboptimally, potentially even worse than in the blocking case. To fill this gap, here we investigate the causes and consequences of interference due to asynchronous I/O on HPC systems. Specifically, we focus on multi-core CPUs and memory bandwidth, isolating the interference due to each resource. Then, we perform an in-depth study to explain the interplay and contention in a variety of resource sharing scenarios such as varying priority and number of background I/O threads and different I/O strategies: sendfile, read/write, mmap/write underlining trade-offs. The insights from this study are important both to enable guided optimizations of existing background I/O, as well as to open new opportunities to design advanced asynchronous I/O strategies.

97 MATHEMATICS AND COMPUTING↗

S4PST: Sustainability for Programming Systems and Tools: May Workshop Report

The US Department of Energy (DOE) Exascale Computing Project (ECP) has fostered and strengthened the use of modern software engineering practices for developing applications and libraries, and this effort has resulted in the coordinated and interoperable E4S1 and xSDK2 ecosystems. Although this approach is cost-effective, it relies on robust programming systems and tools (PST) as the underlying foundation for our HPC software. At present, our primary PST stack consists of traditional high-performance computing (HPC) languages, namely Fortran, C, C++, and the popular Python language for data analysis and AI workflows. These languages support various programming frameworks and run-time abstractions that enable parallelism and concurrency across multiple node architectures and thousands of nodes through a variety of interconnect systems. However, to accommodate users’ diverse needs, certain aspects of the HPC ecosystem are delegated to vendor-specific or third-party implementations that extend beyond a particular scientific domain. This broader scope results in a multitude of specifications and variations, which leads to a complex orchestration of many-ecosystems. Unfortunately, this complexity in the ecosystem imposes additional overhead costs on consumers during the latter stages of the development cycle. In addition to the software ecosystem challenge, the upcoming conclusion of the ECP by December 2023 has raised significant concerns within the HPC programming systems community, from both the economic and social perspectives. The ECP has implemented a management structure for software development and funding decisions across all ECP participants by following a conventional hierarchical and centralized approach. However, this structure has prompted certain considerations within the community, particularly in anticipation of the Software Sustainability initiative by the DOE’s Advanced Scientific Computing Research Program (ASCR). For the success of this new initiative, it is of utmost importance to secure consistent funding and foster close engagement with researchers and core developers of existing programming-system products. This collaboration is vital to maintaining the critical capabilities of the current software during the transition phase while proactively adapting to future technology and workforce trends. The community recognizes the significance of adapting to emerging trends and is aware of the inherent fragility of the HPC software ecosystem, particularly in relation to programming systems that cater to all users. The ability to adapt and evolve is essential to staying relevant and effectively addressing these technical, economic, and social challenges. The S4PST team, which represents one of the six ASCR Software Sustainability seedling projects, is dedicated to tackling these challenges through community-based approaches that go beyond the scope of the DOE. This involves collaboration between national laboratories with academia, non-DOE institutions, hardware and system vendors, and international partners. By fostering these partnerships, we aim to create a robust and sustainable HPC software ecosystem that can effectively meet the needs of the community. This new community effort, driven by the eight DOE labs, will take on the responsibility of guiding funding decisions for programming-systems development and maintenance with transparency and consistency across all decisions. Additionally, the team will offer common technical services to the programming systems community, irrespective of their funding situations, and facilitate community-wide incubation to proactively nurture the software ecosystem. By actively engaging with stakeholders and employing a collaborative approach, we can collectively shape the future of programming systems and ensure a robust and thriving HPC software landscape. On May 11–12, 2023, the S4PST team conducted its inaugural kick-off workshop at the Innovative Computing Laboratory (ICL) in the University of Tennessee, Knoxville, hosted by Hartwig Anzt. The workshop encompassed various sessions dedicated to presentations and discussions, with the aim of comprehending the team members’ perspectives on the vision of software sustainability. Additionally, the workshop aimed to identify the technical, economic, and social requirements for sustaining the programming-systems community in the field of HPC. This report provides a summary of the S4PST effort by highlighting five major thrust areas discussed during the workshop: (i) community, (ii) technical support, (iii) training and diversity, (iv) verification, validation and correctness, and (v) emerging technologies. It also encompasses an overview of the presentations and discussions held throughout the event, our views and potential synergies with other seedling efforts, along with the outcomes and key takeaways from our initial discussions.

97 MATHEMATICS AND COMPUTING↗

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Guide to Using GitHub for Developing and Versioning Data Standards and Reporting Formats

Abstract Data standardization combined with descriptive metadata facilitate data reuse, which is the ultimate goal of the Findable, Accessible, Interoperable, and Reusable (FAIR) principles. Community data or metadata standards are increasingly created through an approach that emphasizes collaboration between various stakeholders. Such an approach requires platforms for collaboration on the development process that centers on sharing information and receiving feedback. Our objective in this study was to conduct a systematic review to identify data standards and reporting formats that use version control for developing data standards and to summarize common practices, particularly in earth and environmental sciences. Out of 108 data standards and reporting formats identified in our review, 32 used GitHub as the version control platform, and no other platforms were used. We found no universally accepted methodology for developing and publishing data standards. Many GitHub repositories did not use key features that could help developers to gather user feedback, or to create and revise standards that build on previous work. We provide guidance for community‐driven standard development and associated documentation on GitHub based on a systematic review of existing practices.

54 ENVIRONMENTAL SCIENCES↗

Spatially weighted mutual information image registration for image guided radiation therapy

Purpose: To develop a new metric for image registration that incorporates the (sub)pixelwise differential importance along spatial location and to demonstrate its application for image guided radiation therapy (IGRT). Methods: It is well known that rigid-body image registration with mutual information is dependent on the size and location of the image subset on which the alignment analysis is based [the designated region of interest (ROI)]. Therefore, careful review and manual adjustments of the resulting registration are frequently necessary. Although there were some investigations of weighted mutual information (WMI), these efforts could not apply the differential importance to a particular spatial location since WMI only applies the weight to the joint histogram space. The authors developed the spatially weighted mutual information (SWMI) metric by incorporating an adaptable weight function with spatial localization into mutual information. SWMI enables the user to apply the selected transform to medically ''important'' areas such as tumors and critical structures, so SWMI is neither dominated by, nor neglects the neighboring structures. Since SWMI can be utilized with any weight function form, the authors presented two examples of weight functions for IGRT application: A Gaussian-shaped weight function (GW) applied to a user-defined location and a structures-of-interest (SOI) based weight function. An image registration example using a synthesized 2D image is presented to illustrate the efficacy of SWMI. The convergence and feasibility of the registration method as applied to clinical imaging is illustrated by fusing a prostate treatment planning CT with a clinical cone beam CT (CBCT) image set acquired for patient alignment. Forty-one trials are run to test the speed of convergence. The authors also applied SWMI registration using two types of weight functions to two head and neck cases and a prostate case with clinically acquired CBCT/MVCT image sets. The SWMI registration with a Gaussian weight function (SWMI-GW) was tested between two different imaging modalities: CT and MRI image sets. Results: SWMI-GW converges 10% faster than registration using mutual information with an ROI. SWMI-GW as well as SWMI with SOI-based weight function (SWMI-SOI) shows better compensation of the target organ's deformation and neighboring critical organs' deformation. SWMI-GW was also used to successfully fuse MRI and CT images. Conclusions: Rigid-body image registration using our SWMI-GW and SWMI-SOI as cost functions can achieve better registration results in (a) designated image region(s) as well as faster convergence. With the theoretical foundation established, we believe SWMI could be extended to larger clinical testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PathBot: A Radiology-Pathology Correlation Dashboard

Pathology is considered the “gold standard” of diagnostic medicine. The importance of radiology-pathology correlation is seen in interdepartmental patient conferences such as “tumor boards” and by the tradition of radiology resident immersion in a radiologic-pathology course at the American Institute of Radiologic Pathology. In practice, consistent pathology follow-up can be difficult due to time constraints and cumbersome electronic medical records. We present a radiology-pathology correlation dashboard that presents radiologists with pathology reports matched to their dictations, for both diagnostic imaging and image-guided procedures. In creating our dashboard, we utilized the RadLex ontology and National Center for Biomedical Ontology (NCBO) Annotator to identify anatomic concepts in pathology reports that could subsequently be mapped to relevant radiology reports, providing an automated method to match related radiology and pathology reports. Radiology-pathology matches are presented to the radiologist on a web-based dashboard. We found that our algorithm was highly specific in detecting matches. Our sensitivity was slightly lower than expected and could be attributed to missing anatomy concepts in the RadLex ontology, as well as limitations in our parent term hierarchical mapping and synonym recognition algorithms. By automating radiology-pathology correlation and presenting matches in a user-friendly dashboard format, we hope to encourage pathology follow-up in clinical radiology practice for purposes of self-education and to augment peer review. We also hope to provide a tool to facilitate the production of quality teaching files, lectures, and publications. Diagnostic images have a richer educational value when they are backed up by the gold standard of pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the underlying data structure for such CBPS. The objective of the research effort is to develop guidance on how to design both the user interface and the underlying schema. This paper will describe the result and insights gained from the research activities conducted to date.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Radiation Doses Due to Consumption of Contaminated Food Items and Calculation of Food Class-Specific Derived Intervention Levels

This document evaluates the expected radiation dose due to the consumption of several specific food classes (dairy, meat, produce, etc.) contaminated with specific radionuclides, and relates concentration levels in food to the detection abilities of typical aboratory analysis/measurement methods. The attached charts present the limiting organ dose as a function of the radionuclide concentration in a particular food class, and allow the user to compare these concentrations and doses to typical analytical detection apabilities. The expected radiation dose depends on several factors: the age of the individual; the radionuclide present in the food; the concentration of the radionuclide in the food; and the amount of food consumed. Food consumption rates for individuals of various ges were taken from the 1998 United States Food and Drug Administration (FDA) document, Accidental Radioactive Contamination of HUman Food and Animal Feeds: Recommendations for State and Local Agencies. In that document, the FDA defines the erived Intervention Level (DIL), which is the concentration of a particular radionuclide in food that if consumed could result in an individual receiving a radiation dose exceeding the Protection Action Guide (PAG) thresholds for intervention. This document also resents odified, food class specific DIL, which is calculated using a somewhat modified version of the FDA's procedure. This document begins with an overview of the FDA's DIL calculation, followed by a description of the food class specific DIL calculations, and finally charts of the radiation dose per radioactivity concentration for several food class/radionuclide combinations.

61 RADIATION PROTECTION AND DOSIMETRY↗