Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPORIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Short-term, seasonal and interannual variability of the vertical distribution of water vapor observed by AIRS

The Atmospheric Infrared Sounder (AIRS) consists of a suite of instruments on board the Aqua spacecraft which retrieve atmospheric parameters over the globe at radiosonde quality on a daily basis in non-precipitating fields of view with less than 80% cloud cover. Although quantitative global measurements of water vapor have been available since the 1980's, the vertical resolution of these measurements was very coarse. AIRS provides global coverage amounting to 324,000 precipitable water vapor profiles with spatial resolution at nadir of 45 km and a vertical resolution in the troposphere of 2 km.

remote sounding↗

Biases in Total Precipitable Water Vapor Climatologies from Atmospheric Infrared Sounder and Advanced Microwave Scanning Radiometer

We examine differences in total precipitable water vapor (PWV) from the Atmospheric Infrared Sounder (AIRS) and the Advanced Microwave Scanning Radiometer (AMSR-E) experiments sharing the Aqua spacecraft platform. Both systems provide estimates of PWV over water surfaces. We compare AIRS and AMSR-E PWV to constrain AIRS retrieval uncertainties as functions of AIRS retrieved infrared cloud fraction. PWV differences between the two instruments vary only weakly with infrared cloud fraction up to about 70%. Maps of AIRS-AMSR-E PWV differences vary with location and season. Observational biases, when both instruments observe identical scenes, are generally less than 5%. Exceptions are in cold air outbreaks where AIRS is biased moist by 10-20% or 10-60% (depending on retrieval processing) and at high latitudes in winter where AIRS is dry by 5-10%. Sampling biases, from different sampling characteristics of AIRS and AMSR-E, vary in sign and magnitude. AIRS sampling is dry by up to 30% in most high-latitude regions but moist by 5-15% in subtropical stratus cloud belts. Over the northwest Pacific, AIRS samples conditions more moist than AMSR-E by a much as 60%. We hypothesize that both wet and dry sampling biases are due to the effects of clouds on the AIRS retrieval methodology. The sign and magnitude of these biases depend upon the types of cloud present and on the relationship between clouds and PWV. These results for PWV imply that climatologies of height-resolved water vapor from AIRS must take into consideration local meteorological processes affecting AIRS sampling.

Atmospheric Infrared Sounder (AIRS)↗

Seasonal Correlations of SST, Water Vapor, and Convective Activity in Tropical Oceans: A New Hyperspectral Data Set for Climate Model Testing

The analysis of the response of the Earth Climate System to the seasonal changes of solar forcing in the tropical oceans using four years of the Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Sounding Unit (AMSU) data between 2002 and 2006 gives new insight into amplitude and phase relationships between surface and tropospheric temperatures, humidity, and convective activity. The intensity of the convective activity is measured by counting deep convective clouds. The peaks of convective activity, temperature in the mid-troposphere, and water vapor in the 0 - 30 N and 0 - 30 S tropical ocean zonal means occur about two months after solstice, all leading the peak of the sea surface temperature by several weeks. Phase is key to the evaluation of feedback. The evaluation of climate models in terms of zonal and annual means and annual mean deviations from zonal means can now be supplemented by evaluating the phase of key atmospheric and surface parameters relative to solstice. The ability of climate models to reproduce the statistical flavor of the observed amplitudes and relative phases for broad zonal means should lead to increased confidence in the realism of their water vapor and cloud feedback algorithms. AIRS and AMSU were launched into a 705 km altitude polar sun-synchronous orbit on the EOS Aqua spacecraft on May 4, 2002, and have been in routine data gathering mode since September 2002.

Atmospheric Infrared Sounder↗

Seasonal Correlations of SST, Water Vapor, and Convective Activity in Tropical Oceans: A New Hyperspectral Data Set for Climate Model Testing

The analysis of the response of the Earth Climate System to the seasonal changes of solar forcing in the tropical oceans using four years of the Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Sounding Unit (AMSU) data between 2002 and 2006 gives new insight into amplitude and phase relationships between surface and tropospheric temperatures, humidity, and convective activity. The intensity of the convective activity is measured by counting deep convective clouds. The peaks of convective activity, temperature in the mid-troposphere, and water vapor in the 0-30 N and 0-30 S tropical ocean zonal means occur about two months after solstice, all leading the peak of the sea surface temperature by several weeks. Phase is key to the evaluation of feedback. The evaluation of climate models in terms of zonal and annual means and annual mean deviations from zonal means can now be supplemented by evaluating the phase of key atmospheric and surface parameters relative to solstice. The ability of climate models to reproduce the statistical flavor of the observed amplitudes and relative phases for broad zonal means should lead to increased confidence in the realism of their water vapor and cloud feedback algorithms. AIRS and AMSU were launched into a 705 km altitude polar sun-synchronous orbit on the EOS Aqua spacecraft on May 4, 2002, and have been in routine data gathering mode since September 2002.

Atmospheric Infrared Sounder (AIRS)↗

New Raman Water Vapor and Temperature Lidar at JPL Table Mountain Facility: Optimization, Validations and Sonde Intercomparison

Jet Propulsion Laboratory currently operates lidar systems at Table Mountain Facility (TMF), California (34.4 deg N, 117.7 deg W at 2300m) and Mauna Loa Observatory (MLO), Hawaii (19.5 deg N, 155.6 deg W at 3400m) under the Network for the Detection of Atmospheric Composition Change (NDACC, formerly NDSC). To complement existing NDACC lidars at TMF, which acts as a primary site for inter-comparisons, a new water vapor and temperature lidar has begun routine operation with typically 3-4 nightly profiles per week. As water vapor is a key greenhouse gas, and is highly variable on annual and seasonal cycles, accurate long term measurements are necessary for predictions of climate change and to increase our understanding of the atmospheric processes it contributes to. The new TMF lidar has demonstrated high spatial and temporal resolution, with a high degree of optimization being achieved over the past year, although the authors believe further improvement may yet be possible. The lidar has been designed for accuracies of 5% up to 12km in the free troposphere with the capability to measure to the tropopause and lower stratosphere with accuracies of 1 ppm. It is anticipated that the data sets produced will be used for Aura validation and for incorporation into NDACC archives. Validation results for the optimized system are presented with intercomparisons using Vaisala RS92-K radiosondes.

water vapor↗

Measurements of Humidity in the Atmosphere: Validation Experiments (MOHAVE I and MOHAVE II). Results Overview and Implication for the Long-Term Lidar Monitoring of Water Vapor in the UT/LS

1. MOHAVE+MOHAVE II = very successful. 2. MOHAVE -> Fluorescence was found to be inherent to all three participating lidars. 3. MOHAVE II -> Fluorescence was removed and agreement with CFH was extremely good up to 16-18 km altitude. 4. MOHAVE II -> Calibration tests revealed unsuspected shortfalls of widely used techniques, with important implications for their applicability to longterm measurements. 5. A factor of 5 in future lidar signal-to-noise ratio is reasonably achievable. When this level is achieved water vapor Raman lidar will become a key instrument for the long-term monitoring of water vapor in the UT/LS

MOHAVE II↗

Major Upgrades to the AIRS Version-6 Water Vapor Profile Methodology

This research is a continuation of part of what was shown at the last AIRS Science Team Meeting and the AIRS 2015 NetMeeting. AIRS Version 6 was finalized in late 2012 and is now operational. Version 6 contained many significant improvements in retrieval methodology compared to Version 5. Version 6 retrieval methodology used for the water vapor profile q(p) and ozone profile O3(p) retrievals is basically unchanged from Version 5, or even from Version 4. Subsequent research has made significant improvements in both water vapor and O3 profiles compared to Version 6.

Version-6↗

Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS) Validation of Three Years of Ozone and Water Vapor Data

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed three years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles with those of in situ and satellite data.

stratospheric ozone↗

Stratospheric Aerosol and Gas Experiment III on the International Space Station(SAGE III/ISS) Validation of Three Years of Ozone and Water Vapor Data

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed three years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles with those of in situ and satellite data.

SAGE III ISS ozone water vapor validation↗

Temporal Changes in Endmember Abundances, Liquid Water and Water Vapor Over Vegetation at Jasper Ridge

In this study, a Modtran-based calibration approach was used to map liquid water and atmospheric water vapor and retrieve surface reflectance from three AVIRIS scenes acquired in 1992 over the Jasper Ridge Biological Preserve. Temporal trends in endmember fractions, liquid water and atmospheric water vapor were investigated also. The combination of spectral mixture analysis and the Modtran based atmospheric/liquid water models was used to develop a unique vegetation community description.

liquid↗

Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS) Newly Released V5.2 Validation of Ozone and Water Vapor Data

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed over three and a half years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles from the newly released v5.2 science product with those of in situ and satellite data .

stratospheric↗

Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS) Validation of Ozone and Water Vapor Data

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed four years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. Recently, the latest version 5.2 data product has been released to the public. This presentation shows the validation results of comparing v5.2 SAGE III/ISS ozone and water vapor vertical profiles with those of in situ and satellite data.

SAGE Stratosphere Stratospheric Mesospheric Ozone ↗

Stratospheric Water Vapor Observations From the International Space Station By the Stratospheric Aerosol and Gas Experiment III (Sage III/ISS)

The Stratospheric Aerosol and Gas Experiment III has routinely observed the upper atmosphere from the International Space Station (SAGE III/ISS) since June 2017. An important greenhouse gas and molecule affecting chemistry cycles, water vapor is among the vertical profiles of trace gases measured by SAGE III/ISS. This makes SAGE III/ISS the youngest of the current fleet of space-based instruments capable of measuring the vertical distribution of stratospheric water vapor (SWV). The SWV record is mature, a candidate for multi-instrument datasets, e.g. Stratospheric Water and Ozone Satellite Homogenized (SWOOSH) dataset, and shows promise within the GEOS Constituent Data Assimilation System. This presentation reviews the variations in SWV observed by SAGE III/ISS over the past half-decade. Variations highlighted include phase changes of the Quasi-biennial Oscillation (QBO), seasonal and monsoonal moisture patterns, and terrestrial events such as the recent January 2022 Hunga Tonga eruption that perturbed the SWV in spectacular fashion.

stratospheric water vapor↗

Stratospheric Temperature and Ozone Impacts of the Hunga Tonga-Hunga Ha'apai Water Vapor Injection

The January 2022 eruption of the Hunga Tonga-Hunga Ha'apai underwater volcano injected a large amount of water vapor into the mid-stratosphere. This study uses model simulations to investigate the resulting stratospheric impacts out to 2031. Maximum radiatively-driven model temperature changes occur in the Southern Hemisphere (SH) subtropics in April–May 2022, with warming of ∼1 K in the lower stratosphere and cooling of 3 K in the mid-stratosphere. The radiative cooling combined with adiabatic cooling driven by the quasi-biennial oscillation meridional circulation explains the near-record cold anomaly observed in the SH subtropical mid-stratosphere. Projected ozone responses maximize in 2023–2024 as the water vapor plume is transported globally throughout the stratosphere and mesosphere. The excess H2O increases the OH radical, causing a negative global ozone response (2%–10%) in the upper stratosphere and mesosphere due to increased odd hydrogen-ozone loss, and a small positive ozone response (0.5%–1%) in the mid-stratosphere due to interference of the NOx catalytic loss cycle by the additional OH. In the lower stratosphere, the excess H2O is projected to increase polar stratospheric clouds and springtime halogen-ozone loss, enhancing the Antarctic ozone hole by 25–30 DU in 2023. Arctic impact is small, with maximum additional ozone loss of 4–5 DU projected in spring 2024. These responses diminish after 2024 to be quite small by 2031, as the excess H2O is removed from the stratosphere with a 2.5-year e-folding time. Given the year-to-year variability of the stratosphere, the magnitudes of these ozone responses may be below the threshold of detectability in observations.

stratosphere↗

Estimating the Impact of Vadose Zone Sources on Groundwater to Support Performance Assessment of Soil Vapor Extraction

A generalized conceptual model approach was developed that can be used to estimate the impact of volatile contaminant sources in the vadose zone on groundwater for sites where soil vapor extraction (SVE) operations have diminished source strength. The model has the potential to be broadly applicable for sites where vapor-phase transport dominates. The primary target for this conceptual model and related numerical modeling estimate of groundwater impact is for sites where contaminants have been removed from readily accessible portions of the subsurface, but where contaminants may persist in localized portions of the vadose zone. This paper describes the conceptual model, uses numerical simulations to evaluate the parameters controlling impact to groundwater, and presents estimated results for a range of input conditions. Over the implied ranges, the compliance well concentrations showed (inverse) proportionality with source concentration, Henry’s Law constant, and well screen length. An increase in site recharge caused a linear response in well concentration, with slopes dependent on the groundwater velocity. All other tested parameters resulted in nonlinear responses. The functional relationship between dimensional and transport parameters and resulting groundwater concentrations provide a basis for establishing a structured approach to evaluating the potential risk to groundwater posed by a vadose zone source. This type of evaluation is particularly important to sites where SVE has been applied and reduced contaminant concentrations, but has reached a condition of diminishing returns such that a site must consider whether continuation of SVE, remedy modifications, or closure is warranted.

remediation↗

Estimating the Impact of Vadose Zone Sources on Groundwater to Support Performance Assessment of Soil Vapor Extraction

Soil vapor extraction (SVE) is a prevalent remediation approach for volatile contaminants in the vadose zone. To support selection of an appropriate endpoint for the SVE remedy, an evaluation is needed to determine whether vadose zone contamination has been diminished sufficiently to protect groundwater. When vapor-phase transport is an important component of the overall contaminant fate and transport from a vadose zone source, the contaminant concentration expected in groundwater is controlled by a limited set of parameters, including specific site dimensions, vadose zone properties, and source characteristics. An approach was developed for estimating the contaminant concentration in groundwater resulting from a contaminant source in the vadose zone based on pre-modeling contaminant transport for a matrix of parameter value combinations covering a range of potential site conditions. An interpolation and scaling process are then applied to estimate groundwater impact for site-specific conditions.

58 GEOSCIENCES↗

Building America Top Innovations 2012: Vapor Retarder Classification

This Building America Top Innovations profile describes research in vapor retarders. Since 2006 the IRC has permitted Class III vapor retarders like latex paint (see list above) in all climate zones under certain conditions thanks to research by Building America teams.

Building America↗