Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Kepler Science Operations Center Architecture

We give an overview of the operational concepts and architecture of the Kepler Science Data Pipeline. Designed, developed, operated, and maintained by the Science Operations Center (SOC) at NASA Ames Research Center, the Kepler Science Data Pipeline is central element of the Kepler Ground Data System. The SOC charter is to analyze stellar photometric data from the Kepler spacecraft and report results to the Kepler Science Office for further analysis. We describe how this is accomplished via the Kepler Science Data Pipeline, including the hardware infrastructure, scientific algorithms, and operational procedures. The SOC consists of an office at Ames Research Center, software development and operations departments, and a data center that hosts the computers required to perform data analysis. We discuss the high-performance, parallel computing software modules of the Kepler Science Data Pipeline that perform transit photometry, pixel-level calibration, systematic error-correction, attitude determination, stellar target management, and instrument characterization. We explain how data processing environments are divided to support operational processing and test needs. We explain the operational timelines for data processing and the data constructs that flow into the Kepler Science Data Pipeline.

Middour, Christopher↗

CFD Simulations of the IHF Arc-Jet Flow: Compression-Pad/Separation Bolt Wedge Tests

This paper reports computational analyses in support of two wedge tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using two different wedge models, each placed in a free jet downstream of a corresponding different conical nozzle in the Ames 60-MW Interaction Heating Facility. Each panel test article included a metallic separation bolt imbedded in Orion compression-pad and heatshield materials, resulting in a circular protuberance over a flat plate. The protuberances produce complex model flowfields, containing shock-shock and shock-boundary layer interactions, and multiple augmented heating regions on the test plate. As part of the test calibration runs, surface pressure and heat flux measurements on water-cooled calibration plates integrated with the wedge models were also obtained. Surface heating distributions on the test articles as well as arc-jet test environment parameters for each test configuration are obtained through computational fluid dynamics simulations, consistent with the facility and calibration measurements. The present analysis comprises simulations of the nonequilibrium flowfield in the facility nozzle, test box, and flowfield over test articles, and comparisons with the measured calibration data.

CFD↗

Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) Concept

Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features. Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutron spectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, to derive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibrating the instrument to elemental abundance measurements made for known samples in the laboratory. We describe the Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time, it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than 10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust Solar Electric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos at distances as low as 27 km.

Dibraccio, Gina↗

OSIRIS User's Manual, v. 1.0

The On-Site Inspection RadioIsotopic Spectroscopy (OSIRIS) system is a gamma-ray spectroscopy instrument for on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). [1] OSIRIS identifies fission-product isotopes with a high-resolution gamma-ray spectrometer. The spectrometer is controlled by a ruggedized notebook computer running data acquisition and data analysis software customized for CTBT on-site inspections. This manual explains OSIRIS preparation and setup for operation; startup procedures, including energy-calibration of the spectrometer; spectral measurements and spectral analyses; and shutdown procedures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Probabilistic Groundwater Modeling of the RDX Plume at Los Alamos National Laboratory to Support Risk Assessment - 20359

A plume of the contaminant hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) with concentrations greater than the New Mexico tap water drinking standard (9.66 ppb) is present in the regional aquifer near the southwestern boundary of Los Alamos National Laboratory (LANL). A risk assessment is performed for exposure to regional aquifer groundwater, with long-term predictions of RDX concentrations provided by a calibrated, probabilistic, numerical fate and transport model. The structure of the model is hierarchical, with the RDX Regional Aquifer (RA) groundwater model acting as the primary tool for analysis of downgradient RDX concentrations. The RA model is deeply informed by the conceptual site model (CSM) and is calibrated using site RDX concentration data and hydraulic head measurements, along with other analyses. The model is calibrated using data through December 2019. Where data are scarce other lines of evidence are used to inform inputs, including the multiphase RDX Vadose Zone (VZ) model and Pipe and Disk analytical screening tool. Model inputs are described with informative prior distributions using a robust approach to development that incorporates all available lines of evidence for every parameter used as an input to the RA model. Calibration is performed using a classical nonlinear optimization routine, which is then used to initialize a Bayesian calibration. The Bayesian calibration constrains the uncertainty in the classical calibration, ultimately providing posterior distributions for all model parameters. The challenges of the calibration include high-dimensional parameter space, including spatially heterogeneous hydraulic conductivities, comparatively sparse data, and low RDX concentrations. Posterior parameter distributions developed in the calibration process are then used for stochastic predictive model runs into the future. The result of the forward runs is spatially and temporally explicit estimates of head and concentration with uncertainty at all points in space and time. The probabilistic modeling approach presented here includes innovative computational and statistical methods that leverage high-performance computing (HPC) resources. It makes use of prior modeling work performed at the chromium plume site in the central LANL area, with extensive updates. The risk assessment will ultimately be used to support decision-making at the site, using multiple appropriately weighted sources of information, as well as uncertainty, sensitivity, and value-of-information analyses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cell dark current–voltage from non-calibrated module electroluminescence image analysis

Here, we present a fast, accurate, and reliable method of obtaining cell dark current–voltage (I–V) curves from module electroluminescence (EL) images without requiring calibration or correction. For a pristine module, EL-derived dark I–V are compared to directly probed data for a variety of changing imaging parameters: camera sensor, lens, filter, aperture width, exposure time (level of sensor saturation), number of images used, and various combinations of these. Pristine modules and those experiencing different modes and degrees of degradation are examined. A recent study of modules using five different cell technologies demonstrates the practicality of our “EL sweep” technique for performance and degradation studies.

14 SOLAR ENERGY↗

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE↗

Training calibration-based counterfactual explainers for deep learning models in medical image analysis

The rapid adoption of artificial intelligence methods in healthcare is coupled with the critical need for techniques to rigorously introspect models and thereby ensure that they behave reliably. This has led to the design of explainable AI techniques that uncover the relationships between discernible data signatures and model predictions. In this context, counterfactual explanations that synthesize small, interpretable changes to a given query while producing desired changes in model predictions have become popular. This under-constrained, inverse problem is vulnerable to introducing irrelevant feature manipulations, particularly when the model’s predictions are not well-calibrated. Hence, in this paper, we propose the TraCE (training calibration-based explainers) technique, which utilizes a novel uncertainty-based interval calibration strategy for reliably synthesizing counterfactuals. Given the wide-spread adoption of machine-learned solutions in radiology, our study focuses on deep models used for identifying anomalies in chest X-ray images. Using rigorous empirical studies, we demonstrate the superiority of TraCE explanations over several state-of-the-art baseline approaches, in terms of several widely adopted evaluation metrics. Our findings show that TraCE can be used to obtain a holistic understanding of deep models by enabling progressive exploration of decision boundaries, to detect shortcuts, and to infer relationships between patient attributes and disease severity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fireball end heights - A diagnostic for the structure of meteoric material

An earlier analysis of Prairie Network fireball trajectory data failed to discriminate between the varieties of meteoric materials that are thought to be present. The Lost City meteorite event offers another calibration of the fireball data and prompts a reanalysis intended to distinguish between ordinary chondritic meteorites and the more fragile early-type carbonaceous chondrites. The carbonaceous material is expected to ablate more readily and have shorter trajectories or higher end heights. Observational error and natural dispersion in the structures produce severe smoothing effects, and the end-height diagnostic is, in itself, not entirely convincing. However, after making a tentative division of the data, one can discern differences in orbits and beginning heights among the three end-height groups. These are consistent with expectations of the behavior of chondritic stones (group I), weak carbonaceous chondrites (group II), and still more fragile cometary material (group III). It is concluded that if the carbonaceous material occurs in reasonable abundance among the fireballs, it has been properly identified by this analysis.

Ceplecha, Z.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

Mars 2020 Radiometric Data and Telemetry Processing, Attitude Estimation, and Thruster Calibration for Orbit Determination

The Mars 2020 spacecraft was spin-stabilized during cruise, just like its predecessor, the Mars Science Laboratory. This spinning motion imparts a signature in the radiometric tracking data that must be dealt with in order to properly model the motion of the spacecraft's center of mass. We discuss how the Orbit Determination team pre-processed the data for efficient computations while also providing other benefits such as high-fidelity attitude modeling and on-board clock verification. Finally, we discuss the analysis and results of the in-flight thruster calibration activity.

Seubert, Jill↗

Uncertainty Analysis of Inertial Model Attitude Sensor Calibration and Application with a Recommended New Calibration Method

Statistical tools, previously developed for nonlinear least-squares estimation of multivariate sensor calibration parameters and the associated calibration uncertainty analysis, have been applied to single- and multiple-axis inertial model attitude sensors used in wind tunnel testing to measure angle of attack and roll angle. The analysis provides confidence and prediction intervals of calibrated sensor measurement uncertainty as functions of applied input pitch and roll angles. A comparative performance study of various experimental designs for inertial sensor calibration is presented along with corroborating experimental data. The importance of replicated calibrations over extended time periods has been emphasized; replication provides independent estimates of calibration precision and bias uncertainties, statistical tests for calibration or modeling bias uncertainty, and statistical tests for sensor parameter drift over time. A set of recommendations for a new standardized model attitude sensor calibration method and usage procedures is included. The statistical information provided by these procedures is necessary for the uncertainty analysis of aerospace test results now required by users of industrial wind tunnel test facilities.

Tripp, John S.↗

Dose-Response Evaluation of Braslet-M Occlusion Cuffs

Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques.

Ebert, Douglas↗

Multiple-Input Data Acquisition System (MIDAS) for Measuring the Carbon Content in Soil Using Inelastic Neutron Scattering

This report describes work funder under STTR grants Phase I and II and carried out jointly by XIA LLC and Brookhaven National Laboratory (BNL). The project goal was to develop a mobile nuclear activation analysis instrument that could be towed behind a tractor to document soil carbon levels in agricultural lands for carbon credit certification. XIA developed large NaI(Tl) detectors with integrated digital pulse processors controlled over USB 2.0 and delivered 16 of these units to BNL for integration into the prototype instrument, together with the necessary software to calibrate them and collect data. For reasons that are unknown to XIA, the BNL participants never completed the prototype vehicle, performed system integration, or carried out the proposed qualification and field tests, leaving the project incomplete.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Measured Driver Behavior Distributions to Results from Car-Following Models using SUMO and Real-World Vehicle Trajectories from Radar: SUMO Default vs. Radar-Measured CF model Parameters

In this study, the physical principles governing car-following (CF) behavior and their impact on traffic flow at signalized intersections are investigated. High temporal-resolution radar data is used to provide valuable insights into actual CF behavior, including acceleration, deceleration, and time headway distribution. Demand-calibrated SUMO simulations are run using empirical CF parameter distributions, and three CF models are evaluated: IDM, EIDM, and Krauss. By emulating radar data in SUMO and processing simulated vehicle traces, discrepancies between empirical and simulated parameter distributions are identified. Further analysis includes comparisons with default SUMO CF model parameters. The findings reveal that measured accelerations differ from CF model parameter accelerations and using the empirical value ($\mu = 0.89m/s^2$) leads to unrealistic simulations that fail volume-based calibration. Default parameters for all three models reasonably approximate the mean and median of measured parameters, but fail to capture the true distribution shape, partly due to homogeneity when using default parameters. The results show that it is more effective to simulate with the default parameters provided by SUMO rather than using measurements of real-world distributions without additional calibration. Future work will investigate closing the loop between the measured real-world and SUMO distributions using traditional calibration tactics, as well as assess the impact of calibrated vs. default CF parameters on simulation outputs like fuel consumption.

Schrader, Max (ORCID:0000000336737672)↗

Analysis of Photogrammetry Data from ISIM Mockup, June 1, 2007

During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software.

Nowak, Maria↗

Reconstruction and analysis of exploding wire particle trajectories via automatic calibration of stereo images

Quantitative understanding of the physics of dust or granular matter transport significantly impacts several aspects of burning plasma science and technology. Here, this work takes machine vision techniques popular in robotics and self-driving cars and applies them to identification and analysis of microparticles generated from exploding wires. Using only the image frames and knowledge of the intrinsic properties of the cameras, a Python code was written to identify the particles, automatically calibrate the relative image positions, and extract trajectory data. After identifying approximately 50 particles based on the timing of secondary particle explosions, the eight point and random sample consensus algorithms were used to determine the geometric correlation between the cameras. Over 100 particle matches were found between the two camera views. These correlated trajectories were used in subsequent 3D track reconstruction and analysis of the physics behind the particle motion. The 3D reconstruction resulted in accurate positioning of the particles with respect to the experimental setup. The particle motion was consistent with the effects of a 1 g gravitational field modified by drag forces. Lastly, the methods and analyses presented here can be used in many facets of high temperature plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Skylab program: Earth resources experiment package. Sensor performance evaluation. Volume 6: (S194) L-band radiometer

Analysis of the Skylab S194 L-band radiometer experiment data provided significant results pertaining to the actual realized performance during flight. Analysis of preflight test data provided a baseline from which to compare the experiment flight performance, although many radiometric data performance capabilities could only be demonstrated in the flight environment. The final results establish the overall hardware performance of the S194 system from which prospective users of the flight data can refer for various scientific applications. Instrument performance is presented in the areas of housekeeping and internal calibration parameters, antenna system integrity, dynamic range, linearity, precision, resolution, and absolute accuracy. Supplementary evaluations were included for an error analysis of system calibration stability. Results of the evaluation show that the instrument performance was generally as expected. Conclusions are drawn from the final evaluation results, and recommendations for improving the effectiveness of a future program are offered.

Kenney, G. P.↗