Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Engineering strain, densification, order parameter and magnetic properties of FePt thin films by dense electronic excitations

FePt films prepared by DC sputtering on Si 〈100〉 substrates when annealed at 600 °C for 1 h exhibited a structurally ordered and magnetically hard L1{sub 0} phase. These FePt films were exposed to dense electronic excitations by using 100 MeV oxygen ions as a function of increasing fluences. Such excitations induce pressure and result in the enhancement of order parameter by increasing strain on the FePt films. Apart from this, the surface morphological images from field emission scanning electron microscopy reveal a densification of the films consequent to irradiation and are correlated with the details obtained from Rutherford back scattering analysis. The variation in the values of coercivity correlates well with the change in volume percentage of face centered tetragonal and face centered cubic phase. A coercivity of 14.7 kOe with order parameter 0.92 is achieved at a fluence of 5 × 10{sup 12} ions/cm{sup 2}. The theoretical simulation of the demagnetization curve shows a strong correlation of coercivity and order parameter between the experimentally obtained values with that of simulation. The effect of irradiation induced strain, the structural ordering and coercivity of FePt films as a function of fluences have been discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STAR FORMATION: STATISTICAL MEASURE OF THE CORRELATION BETWEEN THE PRESTELLAR CORE MASS FUNCTION AND THE STELLAR INITIAL MASS FUNCTION

We present a simple statistical analysis of recent numerical simulations exploring the correlation between the core mass function (CMF) obtained from the fragmentation of a molecular cloud and the stellar mass function which forms from these collapsing cores. Our analysis shows that the distributions of bound cores and sink particles obtained in the simulations are consistent with the sinks being formed predominantly from their parent core mass reservoir, with a statistical dispersion of the order of one-third of the core mass. Such a characteristic dispersion suggests that the stellar initial mass function (IMF) is relatively tightly correlated to the parent CMF, leading to two similar distributions, as observed. This in turn argues in favor of the IMF being essentially determined at the early stages of core formation and being only weakly affected by the various environmental factors beyond the initial core mass reservoir, at least in the mass range explored in the present study. Accordingly, the final IMF of a star-forming region should be determined reasonably accurately, statistically speaking, from the initial CMF, provided some uniform efficiency factor. The calculations also show that these statistical fluctuations, due to, e.g., variations among the core properties, broaden the low-mass tail of the IMF compared with the parent CMF, providing an explanation for the fact that the latter appears to underestimate the number of 'pre brown dwarf' cores compared with the observationally derived brown dwarf IMF.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-AB-207A-11: Anatomical and Functional Assessment of Coronary Artery Disease Using Low-Dose Whole-Organ Dynamic Computed Tomography

Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosis level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

A computationally efficient approach for calculating galaxytwo-point correlations

We developed a modification to the calculation of the two-point correlation function commonly used in the analysis of large-scale structure in cosmology. An estimator of the two-point correlation function is constructed by contrasting the observed distribution of galaxies with that of a uniformly populated random catalogue. The assumption that the distribution of random galaxies in redshift is independent of angular position allows us to replace pair-wise combinatorics with fast integration over probability maps. The new method significantly reduces the computation time while simultaneously increasing the precision of the calculation. Also, it only requires cosmological parameters at the last and least computationally expensive stage, which allows for faster exploration of the parameter space.

79 ASTRONOMY AND ASTROPHYSICS↗

Prediction of Spatiotemporal Patterns of Neural Activity from Pairwise Correlations

We designed a model-based analysis to predict the occurrence of population patterns in distributed spiking activity. Using a maximum entropy principle with a Markovian assumption, we obtain a model that accounts for both spatial and temporal pairwise correlations among neurons. This model is tested on data generated with a Glauber spin-glass system and is shown to correctly predict the occurrence probabilities of spatiotemporal patterns significantly better than Ising models only based on spatial correlations. This increase of predictability was also observed on experimental data recorded in parietal cortex during slow-wave sleep. This approach can also be used to generate surrogates that reproduce the spatial and temporal correlations of a given data set.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms might have varying accuracy depending on the underlying cause of ventilation abnormality. This research was supported by a National Health and Medical Research Council (NHMRC) Australia Fellowship, an Cancer Institute New South Wales Early Career Fellowship 13-ECF-1/15 and NHMRC scholarship APP1038399. No commercial funding was received for this work.

60 APPLIED LIFE SCIENCES↗

Dark Energy Survey Year 6 Results: Cosmological Constraints from Galaxy Clustering and Weak Lensing

We present cosmology results combining galaxy clustering and weak gravitational lensing measured in the full six years (Y6) of observations by the Dark Energy Survey (DES) covering $\sim$5000 deg$^2$. We perform a large-scale structure analysis using three two-point correlation functions (3$\times$2pt): (i) cosmic shear from 140 million source galaxy shapes, (ii) galaxy clustering of 9 million lens galaxy positions, and (iii) galaxy-galaxy lensing from their cross-correlation. We model the data in flat $Λ$CDM and $w$CDM cosmologies. The combined analysis yields $S_8\equiv σ_8 (Ω_{\rm m}/0.3)^{0.5} = 0.789^{+0.012}_{-0.012}$ and matter density $Ω_{\rm m} = 0.333^{+0.023}_{-0.028}$ in $Λ$CDM (68% CL), where $σ_8$ is the clustering amplitude. These constraints show a (full-space) parameter difference of 1.8$σ$ from a combination of cosmic microwave background (CMB) primary anisotropy datasets from Planck 2018, ACT-DR6, and SPT-3G DR1. Projected only into $S_8$ the difference is $2.6σ$. In $w$CDM the Y6 3$\times$2pt results yield $S_8 = 0.782^{+0.021}_{-0.020}$, $Ω_{\rm m} = 0.325^{+0.032}_{-0.035}$, and dark energy equation-of-state parameter $w = -1.12^{+0.26}_{-0.20}$. For the first time, we combine all DES dark-energy probes: 3$\times$2pt, SNe Ia, BAO and Clusters. In $Λ$CDM this combination yields a $2.8σ$ parameter difference from the CMB. When combining DES 3$\times$2pt with other low-redshift datasets (DESI DR2 BAO, DES SNe Ia, SPT clusters), we find a 2.3$σ$ parameter difference with CMB. A joint fit of Y6 3$\times$2pt, CMB, and those low-redshift datasets produces the tightest $Λ$CDM constraints to date: $S_8 = 0.806^{+0.006}_{-0.007}$, $Ω_{\rm m} = 0.302^{+0.003}_{-0.003}$, $h = 0.683^{+0.003}_{-0.002}$, and $\sum m_ν< 0.14$ eV (95% CL). In $w$CDM, this combination yields $w = -0.981^{+0.021}_{-0.022}$.

Abbott, T. M.C. [Cerro-Tololo InterAmerican Obs.]↗

Nanoscale magnetic configurations of supported Fe nanoparticle assemblies studied by scanning electron microscopy with spin analysis

Microscopic magnetic behavior of supported nanoparticles is strongly correlated with their functionalities, especially in data storage and biological applications, but still needs to be clarified. We studied nanoscale magnetic configurations of Fe nanoparticle assemblies using scanning electron microscopy with polarization analysis. The flux closure domain configurations and the reduced magnetic correlation length ({approx}250 nm), relative to the conventional thin films, are determined. Quantitative analysis indicates the magnetic interaction energy to be 80-99 meV, close to the magnetic dipolar coupling energy. These direct observations evidence the aforereported simulations and will be valuable for fabricating magnetic nanoparticle assemblies with the desired magnetic properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prediction of Chest Wall Toxicity From Lung Stereotactic Body Radiotherapy (SBRT)

Purpose: To determine patient, tumor, and treatment factors related to the development of late chest wall toxicity after lung stereotactic body radiotherapy (SBRT). Methods and Materials: We reviewed a registry of 134 patients treated with lung SBRT to 60 Gy in 3 fractions who had greater than 1 year of clinical follow-up and no history of multiple treatments to the same lobe (n = 48). Patients were treated as per Radiation Therapy Oncology Group Protocol 0236 without specific chest wall avoidance criteria. The chest wall was retrospectively contoured. Thirty-two lesions measured less than 3 cm, and sixteen measured 3 to 5 cm. The median planning target volume was 29 cm{sup 3}. Results: With a median follow-up of 18.8 months, 10 patients had late symptomatic chest wall toxicity (4 Grade 1 and 6 Grade 2) at a median of 8.8 months after SBRT. No patient characteristics (age, diabetes, hypertension, peripheral vascular disease, or body mass index) were predictive for toxicity, whereas there was a trend for continued smoking (p = 0.066; odds ratio [OR], 4.4). Greatest single tumor dimension (p = 0.047; OR, 2.63) and planning target volume (p = 0.040; OR, 1.04) were correlated with toxicity, whereas distance from tumor edge to chest wall and gross tumor volume did not reach statistical significance. Volumes of chest wall receiving 30 Gy (V30) through 70 Gy (V70) were all highly significant, although this correlation weakened for V65 and V70 and maximum chest wall point dose only trended to significance (p = 0.06). On multivariate analysis, tumor volume was no longer correlated with toxicity and only V30 through V60 remained statistically significant. Conclusions: Tumor size and chest wall dosimetry are correlated to late chest wall toxicity. Only chest wall V30 through V60 remained significant on multivariate analysis. Restricting V30 to 30 cm{sup 3} or less and V60 to 3 cm{sup 3} or less should result in a 10% to 15% risk of late chest wall toxicity or lower.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Convergence behavior of the random phase approximation renormalized correlation energy

Based on the random phase approximation (RPA), RPA renormalization is a robust many-body perturbation theory that works for molecules and materials because it does not diverge as the Kohn-Sham gap approaches zero. Additionally, RPA renormalization enables the simultaneous calculation of RPA and beyond-RPA correlation energies since the total correlation energy is the sum of a series of independent contributions. The first-order approximation (RPAr1) yields the dominant beyond-RPA contribution to the correlation energy for a given exchange-correlation kernel, but systematically underestimates the total beyond-RPA correction. For both the homogeneous electron gas model and real systems, we demonstrate numerically that RPA renormalization beyond first order converges monotonically to the infinite-order beyond-RPA correlation energy for several model exchange-correlation kernels and that the rate of convergence is principally determined by the choice of the kernel and spin polarization of the ground state. The monotonic convergence is rationalized from an analysis of the RPA renormalized correlation energy corrections, assuming the exchange-correlation kernel and response functions satisfy some reasonable conditions. In this work, for spin-unpolarized atoms, molecules, and bulk solids, we find that RPA renormalization is typically converged to 1 meV error or less by fourth order regardless of the band gap or dimensionality. Most spin-polarized systems converge at a slightly slower rate, with errors on the order of 10 meV at fourth order and typically requiring up to sixth order to reach 1 meV error or less. Slowest to converge, however, open-shell atoms present the most challenging case and require many higher orders to converge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Machine-Learning Analysis of Moisture Carryover in Boiling Water Reactors

Moisture carryover (MCO) is modeled in the General Electric Type-4 boiling water reactor (BWR) using machine-learning methods and data from operating plants. Understanding MCO and the conditions that give rise to an elevated value is important since excessive MCO can damage critical turbine components, can result in elevated dose levels to on-site personnel, and can interfere with late-cycle power management. The analysis of MCO takes into account simplifying reactor symmetries and important geometric dependencies. The plant data are taken from several reactors and were collected over multiple years and multiple fuel cycles. A brief description of the origin of MCO in U.S. BWR plants is given. A machine-learning model is constructed from the data using applicable algorithms and data-reduction techniques. Matching model complexity with available data is one of the more challenging machine-learning tasks. Too many features and too little data will lead to overfitting. The data for each fuel cycle included over 6876 original features, 9 for each fuel bundle. Two approaches are used to reduce the data set into a manageable number of features. The first was an engineering analysis that resulted in the selection of steam quality Q and steam liquid phase velocity V L as the main features driving MCO. Using a Q and a V L for each fuel bundle gives 1528 Q and a V L feature describing the reactor behavior. An analysis of different functional forms of these two variables led to the actual inputs to the neural network model. The second approach involved the use of statistical techniques such as Pearson’s correlation and k-means analysis. The identified groupings of bundles behaved similarly. Treating each grouping as a single feature further reduced the input variable set to a manageable number. Here, a model selection criterion is proposed, and results are presented along with a discussion of related issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The completed SDSS-IV extended baryon oscillation spectroscopic survey: geometry and growth from the anisotropic void–galaxy correlation function in the luminous red galaxy sample

ABSTRACT We present an analysis of the anisotropic redshift-space void–galaxy correlation in configuration space using the Sloan Digital Sky Survey extended Baryon Oscillation Spectroscopic Survey (eBOSS) Data Release 16 luminous red galaxy (LRG) sample. This sample consists of LRGs between redshifts 0.6 and 1.0, combined with the high redshift z > 0.6 tail of the Baryon Oscillation Spectroscopic Survey Data Release 12 CMASS sample. We use a reconstruction method to undo redshift-space distortion (RSD) effects from the galaxy field before applying a watershed void-finding algorithm to remove bias from the void selection. We then perform a joint fit to the multipole moments of the correlation function for the growth rate fσ8 and the geometrical distance ratio DM/DH, finding $f\sigma _8(z_\rm {eff})=0.356\pm 0.079$ and $D_M/D_H(z_\rm {eff})=0.868\pm 0.017$ at the effective redshift $z_\rm {eff}=0.69$ of the sample. The posterior parameter degeneracies are orthogonal to those from galaxy clustering analyses applied to the same data, and the constraint achieved on DM/DH is significantly tighter. In combination with the consensus galaxy BAO and full-shape analyses of the same sample, we obtain fσ8 = 0.447 ± 0.039, DM/rd = 17.48 ± 0.23, and DH/rd = 20.10 ± 0.34. These values are in good agreement with the ΛCDM model predictions and represent reductions in the uncertainties of $13{{\ \rm per\ cent}}$, $23{{\ \rm per\ cent}}$, and $28{{\ \rm per\ cent}}$, respectively, compared to the combined results from galaxy clustering, or an overall reduction of 55 per cent in the allowed volume of parameter space.

Nadathur, Seshadri↗

Exploiting correlations in multi-coincidence Coulomb explosion patterns for differentiating molecular structures using machine learning

Coulomb explosion imaging (CEI) is a powerful technique for capturing the real-time motion of individual atoms during ultrafast photochemical reactions. CEI generates high-dimensional data with naturally embedded correlations that allow mapping the coordinated motion of nuclei in molecules. This enables reliable separation of competing reaction pathways and makes this approach uniquely suited for characterizing weak reaction channels. However, rich information contained in experimental CEI patterns remains largely underexploited due to challenges in visualizing correlations between multiple observables in multi-dimensional parameter space. Here we present a new approach to CEI of intermediate-sized polyatomic molecules, detecting up to eight ionic fragments in coincidence and leveraging machine-learning-based analysis to identify patterns and correlations in the resulting high-dimensional momentum-space data, enabling robust molecular structure identification and differentiation. Our approach provides high-dimensional background-free data encoding exceptionally rich structural information and establishes an automated, scalable framework for extracting insightful information from the data. As a demonstration, we apply this method to image and distinguish dichloroethylene isomers, showcasing its potential for broader applications in molecular imaging. Our results pave the way for channel-specific analysis of ultrafast structural dynamics in chemically relevant systems, particularly for disentangling mixed reaction pathways and detecting contributions from weak channels and minority species.

Chemical Physics (physics.chem-ph)↗

Welch Method and Bootstrapping Applied to Subcritical Gamma Noise

We measured the prompt neutron decay constant 𝛼 of the CROCUS zero-power reactor at the Swiss Federal Institute of Technology Lausanne using cross-power spectral density (CPSD) analysis of gamma-gamma correlations from two trans-stilbene organic scintillators positioned near the reactor core. We measured critical and subcritical states, with water levels ranging from 960 mm (critical) to 800 mm (𝜌=−1.4 $ subcritical). Our analysis used the Welch method, dividing signal segments for fast Fourier transform (FFT) frequency analysis and applying bootstrapping uncertainty quantification that uses Welch-defined segments. Results demonstrated a clear increase in the measured 𝛼 as reactor reactivity decreased, distinguishing critical from subcritical conditions. At the 960-mm critical level, 𝛼 was estimated at 155.9 ± 0.7 s −1 , and for the 800-mm subcritical level, 𝛼 increased significantly to 367.3 ± 6.9 s –1 . A linear regression of subcritical states yielded a critical estimate of 154.0 ± 3.1 s –1 , aligning with the static 𝛼 estimate at critical. The bootstrapping method produced normally distributed 𝛼 estimates, confirming data consistency. The gamma CPSD 𝛼 estimates clearly distinguish reactor states and improve monitoring of zero-power reactors. The future deployment of modular and microreactors as potential candidates for noise analysis is demonstrated in CROCUS, particularly zero-power mock-ups of new designs. The improvement of noise analysis in the subcritical domain from this work will support experimental data for reactor deployment and procedure.

CROCUS↗

Internal-external correlation investigations of respiratory induced motion of lung tumors

In gated radiation therapy procedures, the lung tumor position is used directly (by implanted radiopaque markers) or indirectly (by external surrogate methods) to decrease the volume of irradiated healthy tissue. Due to a risk of pneumothorax, many clinics do not implant fiducials, and the gated treatment is primarily based on a respiratory induced external signal. The external surrogate method relies upon the assumption that the internal tumor motion is well correlated with the external respiratory induced motion, and that this correlation is constant in time. Using a set of data that contains synchronous internal and external motion traces, we have developed a dynamic data analysis technique to study the internal-external correlation, and to quantitatively estimate its underlying time behavior. The work presented here quantifies the time dependent behavior of the correlation between external respiratory signals and lung implanted fiducial motion. The corresponding amplitude mismatch is also reported for the lung patients studied. The information obtained can be used to improve the accuracy of tumor tracking. For the ten patients in this study, the SI internal-external motion is well correlated, with small time shifts and corresponding amplitude mismatches. Although the AP internal-external motion reveals larger time shifts than along the SI direction, the corresponding amplitude mismatches are below 5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identifying Nuclear Data Correlated Through Predicting Bias in Integral Experiments via Applying Principal Component Analysis to Random Forest

ABSTRACT Nuclear data (ND) are the input data for neutron‐transport simulations to answer questions related to nuclear technologies. Subsets of ND, here > 20,000 data points, are validated with respect to thousands of criticality experiments that represent various applications on a small scale. The aim of validation with these experiments is to find errors in ND or methods. The key challenge here is that several hundreds of ND are used to simulate one integral value. Hence, one cannot clearly identify what ND are leading to bias in criticality measurements. In fact, a mistake in one nuclear‐data observable can be compensated with an error in another, and the predicted criticality value would still be predicted in agreement with experimental data. Random forest (RF) was previously employed to predict bias in criticality measurements using sensitivities of simulated criticality experiments to ND. The SHapley Additive exPlanations (SHAP) metric was then applied to attribute the importance of each ND experiment and observable to bias prediction. This, however, did not highlight what ND were jointly related to predicting bias. This is important as it could inform us about where compensating errors in ND could hide. We tackle this shortcoming here by first decomposing the ND sensitivities to integral‐experiment simulations into principal components. Then we use principal component projections to predict bias via the RF and SHAP. The SHAP values and principal components are employed to reconstruct detailed SHAP values for each ND observable. We demonstrate that these extended SHAP bias predictions are more robust, less noisy, and more efficient. In addition, we show that this approach accounts for covariance in ND sensitivities and automates the identification of where compensating errors could hide in ND.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗