Building State-of-the-Art Wind Technology Testing Facilities (Fact Sheet)
The new Wind Technology Test Center is the only facility in the nation capable of testing wind turbine blades up to 90 meters in length.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The new Wind Technology Test Center is the only facility in the nation capable of testing wind turbine blades up to 90 meters in length.
Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal’s intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-GHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (μm-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor’s architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perót displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.
This shared resources CRADA defines collaborations between the National Renewable Energy Laboratory (NREL) and Free Flow Power (FFP) set forth in the following Joint Work Statement. Under the terms and conditions described in this CRADA, NREL and FFP will collaborate on the testing of FFP's hydrokinetic river turbine project on the Mississippi River (baseline location near Baton Rouge, LA; alternate location near Greenville, MS). NREL and FFP will work together to develop testing plans, instrumentation, and data acquisition systems; and perform field measurements.
An experiment that measured the parity violating (PV) asymmetry A d in e- 2 H deep inelastic scattering (DIS) at Q 2 ~ 1.10 and 1.90 (GeV/c) 2 and x B ~ 0.3 was completed in experimental Hall A at the Thomas Jefferson National Accelerator Facility. The asymmetry can be used to extract the neutral weak coupling combination (2C 2u -C 2d ), providing a factor of five to six improvement over the current world data. To achieve this precision, asymmetries of the 10 -4 level needed to be measured at event rates up to 500 kHz with high electron detection efficiency and high pion background rejection capability. A specialized scaler-based counting data acquisition system (DAQ) with hardware-based particle identification was successfully implemented. The statistical quality of the asymmetry measurement agreed with the Gaussian distribution to over five orders of magnitudes and the experimental goal of 3-4% statistical uncertainty was achieved. The design and performance of the new DAQ system is presented with the preliminary asymmetry results given in the end.
This funding is to develop a new Synchrotron user facility for microbeam X-ray absorption spectroscopy (XAS) and quantitative X-ray fluorescence (XRF) imaging, at the National Synchrotron Light Source (NSLS) and NSLS-II. It includes design, purchase of components, and construction of the microprobe endstation and controls. Initial development, commissioning, and application is ongoing at NSLS Beamline X15B, with planned transition in 2014-15 to the NSLS-II TES (Tender-Energy Spatially Resolved X-ray Absorption Spectroscopy) beamline. It is optimized for the “tender” energy range of 1-5 keV, reaching up to 8 keV. Thus it uniquely covers the K absorption edges of critical elements Mg, Al, Si, P, S, Cl, and Ca, and can reach up to Co. A stable, high-flux microbeam focus, user-tunable from ~50 to ~5 microns, has been achieved using two-stage achromatic focusing. Existing beamline optics collimate, monochromate, and macro-focus the X-ray beam to ~1 mm at a secondary source aperture (SSA). Beam from the SSA is then re-focused by a pair of mirrors in KB geometry to the microbeam scale. Size of the microbeam is tunable, at the expense of flux, by adjusting the size of the SSA as a virtual source. The new experimental endstation consists of 1) a sample chamber operable as a radiation enclosure with helium atmosphere to facilitate measurements in this energy range, 2) the KB microfocusing optics, 3) a sample-positioning stage for raster-scanning and positioning the sample, 4) X-ray fluorescence detectors, an existing Ge detector for low-signal sensitivity and a new Si detector for high count rates, 5) an optical camera for viewing samples and locating target locations, 6) beam intensity monitors and diagnostics, and 7) controls and data acquisition system. An important aspect of this project is the added capability for fast, on-the-fly scanning of the monochromator (energy), required for fast XAS and advanced XAS imaging. This instrument will be available for initial PI and Co-I measurements, and for General Users to apply for beamtime to use, at NSLS X15B for the remaining operation of NSLS, to September 30, 2014. Phase two of this project will transition this facility, both the primary optics and the endstation, to NSLS-II after NSLS ceases operation. While this transition itself is beyond the scope of the current grant, preparation and planning for it is included.
Fresh fuel experiments for the differential die-away (DDA) project were performed using a DT neutron generator, a 15x15 PWR fuel assembly, and nine 3 He detectors in a water tank inside of a shielded cell at Los Alamos National Laboratory (LANL). Eight different fuel enrichments were created using low enriched (LEU) and depleted uranium (DU) dioxide fuel rods. A list-mode data acquisition system recorded the time-dependent signal and analysis of the DDA signal die-away time was performed. The die-away time depended on the amount of fissile material in the fuel assembly and the position of the detector. These experiments were performed in support of the spent nuclear fuel Next Generation Safeguards Initiative DDA project. Lessons learned from the fresh fuel DDA instrument experiments and simulations will provide useful information to the spent fuel project.
The Renewable Energy Institute International, in collaboration with Greyrock Energy and Red Lion Bio-Energy (RLB) has successfully demonstrated operation of a 25 ton per day (tpd) nameplate capacity, pilot, pre-commercial-scale integrated biorefinery (IBR) plant for the direct production of premium, “drop-in”, synthetic fuels from agriculture and forest waste feedstocks using next-generation thermochemical and catalytic conversion technologies. The IBR plant was built and tested at the Energy Center, which is located in the University of Toledo Medical Campus in Toledo, Ohio.
The Seismo-Hydroacoustic Data Acquisition System (SHDAS) is undergoing evaluation in preparation for its engineering, development, and deployment by the U.S Navy as an ocean bottom seismic monitoring system. At the current stage of development, the production digitizers are being evaluated to confirm their performance prior to packaging and assembly for deployment. The testing of the digitizers is being conducted at Delta Group Electronics, the digitizer fabricator, in San Diego, California, performed by Sandia National Laboratories with the assistance of Leidos and Delta Group Electronics.
We report the results from the March 2, 2017, Ancho Canyon RF collection. While bright electromagnetic signals were seen nearby the firing point, there were no detections of signals from the explosively-fired fuse at a collection point about 570m distant on the East Mesa. However, "liveness" tests of the East Mesa data acquisition system and checks of the timing both suggest that the collection system was working correctly. We examine possible reasons for the lack of detection. Principal among these is that the impulsive signal may be small compared to the radio frequency background on the East Mesa.
The Sodium Freezing and Remelting experiment facility at Argonne National Laboratory has been significantly modified and improved. The main improvement was replacement of the two original stainless steel test sections that had strain gages limited by their bonds to the stainless steel to maximum temperatures of 350°C with a single new test section with strain gages that can be utilized up to 980°C and a thin wall to enhance measured strains. Wetting of stainless steel by sodium within a practical time of one to a few days is expected to require temperatures of 450°C or greater. Thus, the higher temperature strain gages enable wetting in a short time of a few days. Wetting below 350°C would have required an impractically long time of at least weeks. Other improvements included upgrading of the loop configuration, incorporation of a cold finger to purify sodium, a new data acquisition system, and reinstallation of the many heaters, heater controllers, and thermocouples. After the loop had been heated to 400°C for about two hours, an initial sodium freezing test was conducted. It is thought that the sodium might have at least partially wetted the stainless steel wall under these conditions. The strain gage measurements indicate that an incremental step inward deformation of the test section thin wall occurred as the temperature decreased through the sodium freezing temperature. This behavior is consistent with sodium initially adhering to the stainless steel inner wall but breaking away from the wall as the freezing sodium contracted. Conduct of additional sodium freezing tests under well wetted conditions was prevented as a result of stoppage of all electrical work at Argonne by the Laboratory Director on July 25, 2017. A pathway to resuming electrical work is now in place at Argonne and additional sodium freezing testing will resume next fiscal year.
The Atmospheric Radiation Measurement program (ARM) maintains a fleet of monitoring stations to aid in the improved scientific understanding of the basic physics related to radiative feedback processes in the atmosphere, particularly the interactions among clouds and aerosols. ARM obtains continuous measurements and conducts field campaigns to provide data products that aid in the improvement and further development of climate models. All of the measurement campaigns include a suite of solar measurements. The Solar Radiation Research Laboratory at the National Renewable Energy Laboratory supports ARM's full suite of stations in a number of ways, including troubleshooting issues that arise as part of the data-quality reviews; managing engineering changes to the standard setup; and providing calibration services and assistance to the full fleet of solar-related instruments, including pyranometers, pyrgeometers, pyrheliometers, as well as the temperature/relative humidity probes, multimeters, and data acquisition systems that are used in the calibrations performed at the Southern Great Plains Radiometer Calibration Facility. This paper discusses all aspects related to the support provided to the calibration of the instruments in the solar monitoring fleet.
Our proposal was a comprehensive upgrade to the Data Acquisition System and Level 2 Trigger of the KOTO experiment which included: an increase in the number of channels processed due to the construction of a new inner main barrel; an increase in the interconnectivity and computing power of the Level 2 Trigger to allow for real time clustering and veto timing; and an improvement in the processing power and temporary storage capability of the Level 3 Trigger and online reconstruction.
In this paper, we derive the full expression for the shape of the charge distribution that results from the illumination of a photo-multiplier tube. The derivation assumes that the photo-multiplier is operated with low intensity illumination with constant gain. Under these conditions, it is shown that an analytic expression can be formulated that describes details of the spectrum including the pedestal and dark noise with excellent fidelity to allow statistical fits to data. The full formula and its limiting forms under various simplifying assumptions are presented with strategies on their use. The analytic description can be used to formulate data acquisition strategies to perform precise absolute calibration of photo-multipliers, the digitizers, and the data acquisition system.
This note presents the results of a beam test conducted at the Fermilab test beam facility in March 2019. The beam test represents the first such test of the UT readout ASIC, SALT 3.0, in a beam with production UT sensors. Two sensors were tested, one an unirradiated p-in-n sensor, and the second a n-in-p sensor irradiated to twice the maximum expected uence. The beam test demonstrates that the SALT 3.0 ASIC meets our specifications, and can be used for the production. Due to specific issues with the data acquisition system that will not be present in the system in LHCb, a higher threshold was used in the beam test, corresponding to about $6 \sigma$ on the noise. With this higher threshold, the signal-to-noise ratio (S/N) and efficiency are measured. For the unirradiated sensor, a S/N of about 12 is achieved, with a single-hit effciency of at least 99.5%. For the irradiated sensor, a S/N of about 11 is obtained, with a single-hit effciency of about 94%. In the final system in LHCb with a proper threshold of about $3-4 \sigma$ of the noise, we expect to achieve a single-hit effciency of at least 99.5%.
Researchers at Los Alamos National Laboratory have developed the Unattended Dual Current Monitor (UDCM). The UDCM is an ideal solution for current measurement needs such as ion chamber gamma measurements. This data acquisition system simplifies hardware requirements for current applications, and provides added reliability, flexibility, and compatibility as compared with the legacy Miniature Gamma Ray and Neutron Detector (MiniGRAND) technology. It is lightweight, can be portable or mounted, is manufactured using COTS parts, and features a modern Internet-of-Things (IoT) enabled design.
The spindle balancing operation is critical to the performance of precision lathes and should be conducted anytime the configuration of the spindle or its tooling is modified such that an unbalanced condition may occur. Within the machine tool community, accelerometers are typically used as the feedback device during the balancing operation. At Lawrence Livermore National Laboratory (LLNL), we have nearly 40 years of history using displacement sensors, such as capacitance gauges, in place of accelerometers when balancing precision spindles. The process of balancing a precision machine spindle using displacement sensors is presented in the context of two work examples. In this case, the details of the one-dimensional balancing operation performed after replacing a flycutter on the spindles of two unique large optic diamond turning machines is discussed. The pros and cons of accelerometer driven balancing and displacement driven balancing are also presented. In the accelerometer context, the level of balance achieved for our work example is less than 100 micro-g or a total indicator reading (TIR) of 1.6 µm. The process of balancing has been enhanced over the years as advances have been made in software, data acquisition systems, and instrumentation. The balancing system is described including details about instrumentation, set-up, how phase and spindle structure stiffness is calculated, and how the LLNL developed software that guides the user through the process by suggesting corrective action.
The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY21 Sandia’s Neutron Effects Diagnostics (NEDs) and data acquisition systems were upgraded to test novel commercial off-the-shelf and Sandia-fabricated electronic components that support SNL’s National Security mission. The upgrades to the Sandia platform consisted of new cable chains, sample mount fixtures and a new fiber optics platform for testing optoelectronic devices.
The PV Operations and Maintenance (O&M) service industry lacks an affordable, well-documented, intuitive PV modeling and analytics tool to calculate modeled performance from actual data from multiple data acquisition systems (DAS). We envision a performance modeling and analytics platform built on open-source, extensible, community-maintained code. The key innovation is the community-driven development of pvlib python delivered through a lightweight web service to provide configurable, consistent and reproducible PV modeling for O&M providers.