Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Key insights from US Department of Energy Better Plants workforce development bootcamps (2022–2025)

This study examines the effectiveness of the US Department of Energy’s Better Plants Program Bootcamps, which are designed to enhance participants’ technical skills in improving energy efficiency and optimizing operations in manufacturing facilities. Through the analysis of survey data collected from 529 participants across 9 bootcamps, the research investigates the motivations, benefits, and demographic trends of attendees. The findings reveal that skill acquisition and improvement are primary drivers for participation, with key benefits including hands-on training on diagnostic equipment and software tools, networking opportunities, and access to technical resources. The analysis shows strong participation from sectors characterized by high energy consumption and employment, such as chemical and transportation equipment manufacturing. Over 50% of participants have job titles that include “EHS” or “Energy” showing their key roles in leading energy efficiency and energy management efforts in manufacturing. Furthermore, the analysis highlights the distribution of participants across managerial, engineering, and technical roles, revealing a higher representation of managers and engineers. This observation suggests a need for targeted outreach to engage technicians, equipment operators, maintenance staff, and floor workers to ensure comprehensive workforce development. The post-bootcamp survey showed that the participants highly valued the opportunities for peer learning and idea exchange, and the benefits they gained from them. This research contributes to the advancement of manufacturing education by demonstrating the efficacy of specialized training in addressing critical industry challenges and fostering a more competent and empowered workforce.

Energy efficiency↗

Biocompatible surface functionalization architecture for a diamond quantum sensor

Significance Diamond-based quantum sensing enables nanoscale measurements of biological systems with unprecedented sensitivity. Potential applications of this emerging technology range from the investigation of fundamental biological processes to the development of next-generation medical diagnostics devices. One of the main challenges faced by bioquantum sensing is the need to interface quantum sensors with biological target systems. Specifically, such an interface needs to maintain the highly fragile quantum states of our sensor and at the same time be able to fish intact biomolecules out of solution and immobilize them on our quantum sensor surface. Our work overcomes these challenges by combining tools from quantum engineering, single-molecule biophysics, and material processing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analyst Tools and Quality Control Software for the ARM Data System

Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed web-based data analysis and visualization tools such as the interactive plotting program NCVweb, various diagnostic plot browsers, and a datastream processing status application. These tools allow even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers. We have also embarked on a system to comprehensively generate long time-series plots, frequency distributions, and other relevant statistics for scientific and engineering data in most high-level, publicly available ARM data streams. Furthermore, frequency distributions categorized by month or by season are made available to help define valid data ranges specific to those time domains. These statistics can be used to set limits that when checked, will improve upon the reporting of suspicious data and the early detection of instrument malfunction. The statistics and proposed limits are stored in a database for easy reporting, refining, and for use by other processes. Web-based applications to view the results are also available.

54 ENVIRONMENTAL SCIENCES↗

High intensity 5 eV O-atom exposure facility for material degradation studies

An atomic oxygen exposure facility was developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in low Earth orbit. The studies that are being undertaken will provide: (1) absolute reaction cross sections for the engineering design problems, (2) formulations of reaction mechanisms for use in the selection of suitable existing materials and the design of new more resistant ones, and (3) the calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in low Earth orbit to ground based investigations. The facility consists of a CW laser sustained discharge source of O-atoms, an atomic beam formation and diagnostics system, a spinning rotor viscometer, and provision for using the system for calibration of actual flight instruments.

Cross, J. B.↗

Plume spectrometry for liquid rocket engine health monitoring

An investigation of Space Shuttle Main Engine (SSME) testing failures identified optical events which appeared to be precursors of those failures. A program was therefore undertaken to detect plume trace phenomena characteristic of the engine and to design a monitoring system, responsive to excessive activity in the plume, capable of delivering a warning of an anomalous condition. By sensing the amount of extraneous material entrained in the plume and considering engine history, it may be possible to identify wearing of failing components in time for a safe shutdown and thus prevent a catastrophic event. To investigate the possibilities of safe shutdown and thus prevent a monitor to initiate the shutdown procedure, a large amount of plume data were taken from SSME firings using laboratory instrumentation. Those data were used to design a more specialized instrument dedicated to rocket plume diagnostics. The spectral wavelength range of the baseline data was about 220 nanometers (nm) to 15 micrometer with special attention given to visible and near UV. The data indicates that a satisfactory design will include a polychromator covering the range of 250 nM to 1000 nM, along with a continuous coverage spectrometer, each having a resolution of at least 5A degrees. The concurrent requirements for high resolution and broad coverage are normally at odds with one another in commercial instruments, therefore necessitating the development of special instrumentation. The design of a polychromator is reviewed herein, with a detailed discussion of the continuous coverage spectrometer delayed to a later forum. The program also requires the development of applications software providing detection, variable background discrimination, noise reduction, filtering, and decision making based on varying historical data.

Powers, William T.↗

Rotating Detonation Rocket Engine Concept Development

Programmatic overview of rotating detonation rocket engine (RDRE) research at NASA GRC for Scientific American for reference for Scientific American article. This is a compilation of previously released slides. This material will NOT be published as part of the article, but are being provided for background information.

Propulsion↗

Diagnostics of low-temperature structural stability

The failure of materials at low temperatures is studied. The acoustic signals emitted in the extension of steel 45 at low temperature are analyzed. In this conditions, the yield point and strength increase, while the relative elongation declines.

42 ENGINEERING↗

Diagnostics and Recycling of Discarded Automobile Components

Recycling of metal from discarded auto components is expedient and economically efficient. Uses of metal from discarded components are proposed. Information is presented regarding the mechanical properties of structural steels widely used in the auto industry. Technology for recycling of the metal in truck components is identified.

42 ENGINEERING↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

A Few Observations about Mounting Moderately Sized Mirrors

Most of the mirror mounting literature has focused on small (less than 0.1 meters) or large (greater than 1 meter) mirrors. We will examine the theory and practice of mounting moderately sized mirrors (between 0.1 and 1 meter). Two examples will be taken from optical diagnostic systems designed for the National Ignition Facility (NIF). In both cases the mirrors were removable (not bonded in place). One of the examples will be for a mirror with a poor aspect ratio (i.e. diameter to thickness ratio greater than 15:1).

42 ENGINEERING↗

Diagnosing Undersampling in Monte Carlo Eigenvalue and Flux Tally Estimates

This study explored the impact of undersampling on the accuracy of tally estimates in Monte Carlo (MC) calculations. Steady-state MC simulations were performed for models of several critical systems with varying degrees of spatial and isotopic complexity, and the impact of undersampling on eigenvalue and fuel pin flux/fission estimates was examined. This study observed biases in MC eigenvalue estimates as large as several percent and biases in fuel pin flux/fission tally estimates that exceeded tens, and in some cases hundreds, of percent. This study also investigated five statistical metrics for predicting the occurrence of undersampling biases in MC simulations. Three of the metrics (the Heidelberger-Welch RHW, the Geweke Z-Score, and the Gelman-Rubin diagnostics) are commonly used for diagnosing the convergence of Markov chains, and two of the methods (the Contributing Particles per Generation and Tally Entropy) are new convergence metrics developed in the course of this study. These metrics were implemented in the KENO MC code within the SCALE code system and were evaluated for their reliability at predicting the onset and magnitude of undersampling biases in MC eigenvalue and flux tally estimates in two of the critical models. Of the five methods investigated, the Heidelberger-Welch RHW, the Gelman-Rubin diagnostics, and Tally Entropy produced test metrics that correlated strongly to the size of the observed undersampling biases, indicating their potential to effectively predict the size and prevalence of undersampling biases in MC simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiochemistry diagnostics for the National Ignition Facility

Radiochemistry-based techniques will be an important complement to x-ray implosion diagnostics. Simulations demonstrate the value of alpha-induced or deuteron-induced reactions as a direct measurement of static mix contamination in DT-filled ignition capsules. In this proceedings we examine to what extent neutron-induced reactions might be highly correlated with the energetically down-scattered neutron fraction which is, in turn, related to the critical quantity of fuel areal density, {rho}R. Although alpha and deuteron reactions are highly suppressed in HT/D-filled capsules, neutron-induced reactions produce robust abundances and 2% measurements of the relevant radiological ratios is achievable. We conclude that radiochemical data are strongly correlated with the down-scattered fraction and fuel areal density. Unknown physics, primarily uncertainties in the direct T-T fusion neutron cross section and, to a lesser extent, various radiochemical production cross sections are important but calibration shots can be used to reduce these errors. The primary advantage of radiochemistry remains - it is the only technique that samples down-scattered neutrons from the entire capsule during the burn. In particular radiochemistry correlated with other diagnostics can be used to minimize experimental uncertainties and thus maximize gain.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High intensity 5 eV atomic oxygen source and Low Earth Orbit (LEO) simulation facility

An atomic oxygen exposure facility has been developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in LEO. The studies that are being undertaken using the facility will provide: absolute reaction cross sections for use in engineering design problems; formulations of reaction mechanisms; and calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in LEO to ground based investigations. The facility consists of: (1) a CW laser sustained discharge source of O atoms having a variable energy up to 5 eV and an intensity between 10(15) and 10(17) O atoms s(-1) cm(-2); (2) an atomic beam formation and diagnostics system consisting of various stages of differential pumping, a mass spectrometer detector, and a time of flight analyzer; (3) a spinning rotor viscometer for absolute O atom flux measurements; and (4) provision for using the system for calibration of actual flight instruments. Surface analysis equipment is available for the characterization of material surfaces before and after exposure to O atoms.

Cross, J. B.↗

Earth-Independent Medical Operations (EIMO) Concept of Operations

In contrast to the current crew health paradigm for low-Earth orbit and Lunar missions, which depends on real-time communication with Mission Control, deep-space exploration missions will require a significant shift in medical operations. This shift is driven by the constraints of operating at a considerable distance from Earth, such as resource limitations—lack of resupply, restricted mass, power, volume, and data—as well as communication delays and the inability to evacuate back to Earth during emergencies. To move toward a more self-reliant medical model, a strategy is needed to gradually increase space-based crew autonomy and reduce risks to mission success in the challenging environment of deep space. This transformative change, known as "Earth-Independent Medical Operations" (EIMO), explores the gradual transfer of medical care and decision-making from Earth-based support to space-based systems. The goal of this transition is to enhance astronaut health and performance while minimizing mission risks. EIMO requires the development of a medical system that integrates seamlessly with mission planning, vehicle and spacesuit design, and data architecture. This integration is crucial for building a robust medical infrastructure that not only safeguards astronaut well-being but also ensures overall mission success. The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has revised the EIMO model-based Concept of Operations (ConOps) which outlines an initial vision for EIMO. The ConOps, which is built on the stakeholders’ need, system goals, and objectives (NGOs), presents an array of in-mission scenarios that span a wide range of medical conditions demonstrating the system’s capabilities from basic to complex events. Developed by a multidisciplinary team of systems engineers, scientists, and clinicians within ExMC, the ConOps revision includes two new scenarios(Barotrauma and Self-Medical Management and Behavioral Health and Chronic Medical Care), and implementation of findings from EIMO technical interchange meetings that focused on data and training. The envisioned EIMO Medical System (MS) operates as a system of systems, gathering data from various sources such as reference databases, real-time wearable sensors, point-of-care diagnostics, and environmental controls. The MS also incorporates advanced training tools to support autonomous medical care, assisting the Crew Medical Officer (CMO) during medical events where Ground Support is either unavailable or communication-delayed beyond practicality. Furthermore, MS functions and capabilities were decomposed from the scenarios to establish foundational requirements for EIMO and traced to the NASA Spaceflight Human-System Standard(NASA-STD-3001, Volumes 1 and 2). These traces were performed to gain insights on the alignment of EIMO requirements with the NASA standard. This work serves as an initial recommendation to increase crew autonomy gradually and safely for Mars missions and future deep-space exploration.

medical system↗

A Dual-Line Detection Rayleigh Scattering Diagnostic Technique for the Combustion of Hydrocarbon Fuels and Filtered UV Rayleigh Scattering for Gas Velocity Measurements

Non-intrusive techniques for the dynamic measurement of gas flow properties such as density, temperature and velocity, are needed in the research leading to the development of new generation high-speed aircraft. Accurate velocity, temperature and density data obtained in ground testing and in-flight measurements can help understand the flow physics leading to transition and turbulence in supersonic, high-altitude flight. Such non-intrusive measurement techniques can also be used to study combustion processes of hydrocarbon fuels in aircraft engines. Reliable, time and space resolved temperature measurements in various combustor configurations can lead to a better understanding of high temperature chemical reaction dynamics thus leading to improved modeling and better prediction of such flows. In view of this, a research program was initiated at Polytechnic University's Aerodynamics Laboratory with support from NASA Lewis Research Center through grants NAG3-1301 and NAG3-1690. The overall objective of this program has been to develop laser-based, non-contact, space- and time-resolved temperature and velocity measurement techniques. In the initial phase of the program a ND:YAG laser-based dual-line Rayleigh scattering technique was developed and tested for the accurate measurement of gas temperature in the presence of background laser glare. Effort was next directed towards the development of a filtered, spectrally-resolved Rayleigh/Mie scattering technique with the objective of developing an interferometric method for time-frozen velocity measurements in high-speed flows utilizing the uv line of an ND:YAG laser and an appropriate molecular absorption filter. This effort included both a search for an appropriate filter material for the 266 nm laser line and the development and testing of several image processing techniques for the fast processing of Fabry-Perot images for velocity and temperature information. Finally, work was also carried out for the development of a new laser-based strain-rate and vorticity technique for the time-resolved measurement of vorticity and strain-rates in turbulent flows.

Otugen, M. Volkan↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Test Results of the First US ITER TF Conductor in SULTAN

The US Domestic Agency is one of six parties supplying TF cable-in-conduit conductors (CICCs) for ITER. Previous tests have shown that measured performance of the TF CICCs can be much lower than expected from the strand properties at the projected uniaxial strain and that the cabling pattern may also be an important factor. Worst of all, voltage signals well below the expected critical surface could not be reliably interpreted or canceled, making test results very suspect. The TFUS1 sample was prepared to achieve multiple goals: (1) to ensure uniform current distribution and to eliminate parasitic voltage signals by improving joints, (2) to explore the potential benefits of a different cabling pattern for better support of strain-sensitive strands, and (3) to explore the source of voltage development in the cable through the use of innovative penetrating diagnostics. Test results of the first US-made samples are presented and discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗