Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Integrated Demand Management: The FCA Balancing Algorithm

The Collaborative Trajectory Options Program (CTOP) is a new NextGen function that resides within the FAA’s Traffic Flow Management System (TFMS) software. CTOP was designed to be used in the United States’ national airspace to control the distribution of air traffic demand, both temporally and geographically, through a set of Flow Constrained Areas (FCAs). Each FCA is assigned capacity values that represent an estimated upper limit of manageable demand, and CTOP controls to that capacity by using Expect Departure Clearance Time (EDCT) air traffic control clearances, and/or rerouting flights to an alternate FCA or out of the CTOP completely. CTOP’s decisions about which control options best meet system and user needs are based on the Trajectory Options Set (TOS) submitted by airline operators for each flight. The FCA Balancing Algorithm (FBA) described in this document is a proposed decision support capability that generates CTOP capacity entries for FCAs controlling traffic to a common downstream constraint. The FBA provides an equitable distribution of impact, and addresses the added complexity of assigning FCA capacity values for this specific type of use case, greatly simplifying the FAA air traffic manager’s task.

IDM↗

Regulating the spatial distribution of metal nanoparticles within metal-organic frameworks to enhance catalytic efficiency

Composites incorporating metal nanoparticles (MNPs) within metal-organic frameworks (MOFs) have broad applications in many fields. However, the controlled spatial distribution of the MNPs within MOFs remains a challenge for addressing key issues in catalysis, for example, the efficiency of catalysts due to the limitation of molecular diffusion within MOF channels. We report a facile strategy that enables MNPs to be encapsulated into MOFs with controllable spatial localization by using metal oxide both as support to load MNPs and as a sacrificial template to grow MOFs. This strategy is versatile to a variety of MNPs and MOF crystals. By localizing the encapsulated MNPs closer to the surface of MOFs, the resultant MNPs@MOF composites not only exhibit effective selectivity derived from MOF cavities, but also enhanced catalytic activity due to the spatial regulation of MNPs as close as possible to the MOF surface.

36 MATERIALS SCIENCE↗

Decentralized Low-Rank State Estimation for Power Distribution Systems

This article considers the low-observability state estimation problem in power distribution networks and develops a decentralized state estimation algorithm leveraging the matrix completion methodology. Matrix completion has been shown to be an effective technique in state estimation that exploits the low dimensionality of the power system measurements to recover missing information. This technique can utilize an approximate (linear) load flow model, or it can be used with no physical models in a network where no information about the topology or line admittance is available. The direct application of matrix completion algorithms requires solving a semi-definite programming (SDP) problem, which becomes computationally challenging for large networks. We therefore develop a decentralized algorithm that capitalizes on the popular proximal alternating direction method of multipliers (proximal ADMM). The method allows us to distribute the computation among different areas of the network, leading to a scalable algorithm. By doing all computations at individual control areas and only communicating with neighboring areas, the algorithm eliminates the need for data to be sent to a central processing unit and thus increases efficiency and contributes to the goal of autonomous control of distribution networks. We illustrate the advantages of the proposed algorithm numerically using standard IEEE test cases.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Microstructurally based model of fatigue initiation and growth

A model to calculate fatigue life is developed based on the assumption that fatigue life is entirely composed of crack growth from an initial microstructural inhomogeneity. Specifically, growth is considered to start from either an ellipsoidal void, a cracked particle, or a debonded particle. The capability of predicting fatigue life from material microstructure is based on linear elastic fracture mechanics principles, the sizes of the crack-initiating microstructural inhomogeneities, and an initiation parameter that is proportional to the cyclic plastic zone size. A key aspect of this modeling approach is that it is linked with a general purpose probability program to analyze the effect of the distribution of controlling microstructural features within the material. This enables prediction of fatigue stress versus life curves for various specimen geometries using distributional statistics obtained from characterizations of the microstructure. Results are compared to experimental fatigue data from an aluminum alloy.

Brockenbrough, J. R.↗

Modular Autonomous Systems Technology Framework: A Distributed Solution for System Monitoring and Control

The Modular Autonomous Systems Technology (MAST) framework is a tool for building distributed, hierarchical autonomous systems. Originally intended for the autonomous monitoring and control of spacecraft, this framework concept provides support for variable autonomy, assume-guarantee contracts, and efficient communication between subsystems and a centralized systems manager. MAST was developed at NASA's Johnson Space Center (JSC) and has been applied to an integrated spacecraft example scenario.

Badger, Julia M.↗

Plasma-controlled adatom delivery and (re)distribution: Enabling uninterrupted, low-temperature growth of ultralong vertically aligned single walled carbon nanotubes

Large-scale ({approx}10{sup 9} atoms) numerical simulations reveal that plasma-controlled dynamic delivery and redistribution of carbon atoms between the substrate and nanotube surfaces enable the growth of ultralong single walled carbon nanotubes (SWCNTs) and explain the common experimental observation of slower growth at advanced stages. It is shown that the plasma-based processes feature up to two orders of magnitude higher growth rates than equivalent neutral-gas systems and are better suited for the SWCNT synthesis at low nanodevice friendly temperatures.

36 MATERIALS SCIENCE↗

Observation of three dimensional optical rogue waves through obstacles

We observe three-dimensional rogue waves in the speckle distribution of a spatially modulated optical beam. Light is transmitted beyond a partially reflecting obstacle generating optical rogue waves at a controlled position in the shadow of the barrier. When the barrier transmits only 0.07% of the input laser power, we observe the mostly localized event. These results demonstrate that an optimum amount of spatial non-homogeneity maximizes the probability of a gigantic event while the technique we exploit enables to control light behind a fully reflective wall.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demand Response in the ERCOT Markets [Slides]

ERCOT grid serves 85% of Texas load over 40K+ miles transmission line. Demand response: voluntary load response, load resources, controllable load resources, and emergency interruptible load service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Loads Due to Controls at Transonic and Low Supersonic Speeds

Some results of recent experimental investigations at supersonic and transonic speeds are presented to show the present status in the estimation of load distributions on controls and adjacent wing surfaces resulting from the deflection of flap controls and spoiler controls. The results indicate that the development of methods for predicting loads associated with controls has not kept pace with the acquisition of experimental data. At low supersonic speeds sweeping the hinge line induces strong three-dimensional-flow characteristics which cannot be treated by the simplified methods previously developed for controls without sweep. At transonic speeds the estimation of loads associated with controls must usually be dependent upon experimental information inasmuch as the latest attempts to predict chordwise and spanwise loadings have met with only limited success.

West, F. E, Jr↗

Design and implementation of dynamic I/O control scheme for large scale distributed file systems

In this paper, we have analyzed the input/output (I/O) activities of Cori, which is a high-performance computing system at the National Energy Research Scientific Computing Center at Lawrence Berkeley National Laboratory. Our analysis results indicate that most users do not adjust storage configurations but rather use the default settings. In addition, owing to the interference from many applications running simultaneously, the performance varies based on the system status. To configure file systems autonomously in complex environments, we developed DCA-IO, a dynamic distributed file system configuration adjustment algorithm that utilizes the system log information to adjust storage configurations automatically. Our scheme aims to improve the application performance and avoid interference from other applications without user intervention. Moreover, DCA-IO uses the existing system logs and does not require code modifications, an additional library, or user intervention. To demonstrate the effectiveness of DCA-IO, we performed experiments using I/O kernels of real applications in both an isolated small-sized Lustre environment and Cori. Our experimental results shows that our scheme can improve the performance of HPC applications by up to 263% with the default Lustre configuration.

97 MATHEMATICS AND COMPUTING↗

Price Based Local Power Distribution Management System (Local Power Distribution Manager) v1.0

A trans-active energy micro-grid controller is implemented in the VOLTTRON distributed control platform. The system uses the price of electricity as the mechanism for conducting transactions that are used to manage energy use and to balance supply and demand. In order to allow testing and analysis of the control system, the implementation is designed to run completely as a software simulation, while allowing the inclusion of selected hardware that physically manages power. Equipment to be integrated with the micro-grid controller must have an IP (Internet Protocol)-based network connection and a software "driver" must exist to translate data communications between the device and the controller.

BROWN, RICHARDE.↗

High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

14 SOLAR ENERGY↗

A model study of assisted adiabatic transfer of population in the presence of collisional dephasing

Previous studies have demonstrated that when experimental conditions generate non-adiabatic dynamics that prevents highly efficient population transfer between states of an isolated system by stimulated Raman adiabatic passage (STIRAP), the addition of an auxiliary counter-diabatic field (CDF) can restore most or all of that efficiency. This paper examines whether that strategy is also successful in a non-isolated system in which the energies of the states fluctuate, e.g., when a solute is subject to collisions with solvent. We study population transfer in two model systems: (i) the three-state system used by Demirplak and Rice [J. Chem. Phys. 116, 8028 (2002)] and (ii) a four-state system, derived from the simulation studies of Demirplak and Rice [J. Chem. Phys. 125, 194517 (2006)], that mimics HCl in liquid Ar. Simulation studies of the vibrational manifold of HCl in dense fluid Ar show that the collision induced vibrational energy level fluctuations have asymmetric distributions. Representations of these asymmetric energy level fluctuation distributions are used in both models (i) and (ii). We identify three sources of degradation of the efficiency of STIRAP generated selective population transfer in model (ii): too small pulse areas of the laser fields, unwanted interference arising from use of strong fields, and the vibrational detuning. For both models (i) and (ii), our examination of the efficiency of STIRAP + CDF population transfer under the influence of the asymmetric distribution of the vibrational energy fluctuations shows that there is a range of field strengths and pulse durations under which STIRAP + CDF control of population transfer has greater efficiency than does STIRAP generated population transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Load Restoration in Unbalanced Active Distribution Systems

We present that the resilience of modern power systems has been constantly threatened by various natural disasters and manmade attacks. Under those threats, fast and automatic restoration actions are critical for restoring impacted systems to normal operating conditions and preventing from additional disastrous consequences. Smart grid technologies, such as distributed energy resources (DERs) and microgrids, provide both opportunities and challenges for distribution system restoration. In this paper, distributed load restoration (DLR), in unbalanced active distribution networks is developed using the alternating direction method of multipliers (ADMM) algorithm. The step-by-step restoration actions are provided to schedule the output of DERs and distribution system control devices, as well as the power consumption from transmission system restoration. The nonlinearities from three-phase unbalanced power flow and distribution components modeling are relaxed into a convex quadratic programming model. Then, the problem is decomposed into subproblems for each node by applying ADMM-DLR; and solves through each agent by exchanging limited information with neighboring nodes in an iterative procedure. The developed models and algorithms are validated and demonstrated through testing of the IEEE 13-node and 123-node test feeders. Lastly, simulation results demonstrate the effectiveness of restoring unbalanced distribution system with the hybrid bottom-up and top-down restoration strategies.

14 SOLAR ENERGY↗

Balancing Hydronic Systems in Multifamily Buildings

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 5: Integration of Renewable Energy Technologies in Buildings and Cities

Sustainable Energy Technologies, such as the solar, wind, and waterpower systems described in other chapters of this book, need to be integrated into our energy systems to expand access to energy while avoiding harmful effects on the environment. The existing utility system or 'grid' is a network that consists of components for generation, transmission, distribution, and control of electric power from producers (also called 'resources') to consumers (also called 'loads' or 'demand'). Public safety necessitates that the grid be reliable, and public policy requires that grid power be affordable and broadly accessible. Much of the existing power grid was constructed before the advent of modern information technology for controls and automation. The existing grid is facing new challenges related to increases in power demand, complexity in managing more diverse and distributed resources, power quality issues introduced by 'non-linear' loads (that have parasitic inductance and capacitance like LED lights or computers), physical and cybersecurity threats, and challenges to the existing economic model of costs and revenues. Increases in power demand include not only growth in population and per-capita electricity use, but also call for electricity to meet the need for heating and transportation as well. Electric vehicles are a rapidly growing example of this electrification of previously fossil-fueled uses. [Your author's Chevrolet Volt vehicle uses about the same amount of electricity as his house, around 300 kWh/month. Fortunately, both are served with solar photovoltaics (PVs)]. Therefore, there is an immediate need for improvement toward a reliable, self-regulating, efficient, and economical grid system that will allow the integration of renewable distributed power generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗