Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Sample-Averaged Biexciton Quantum Yield Measured by Solution-Phase Photon Correlation

The brightness of nanoscale optical materials such as semiconductor nanocrystals is currently limited in high excitation flux applications by inefficient multiexciton fluorescence. We have devised a solution-phase photon correlation measurement that can conveniently and reliably measure the average biexciton-to-exciton quantum yield ratio of an entire sample without user selection bias. This technique can be used to investigate the multiexciton recombination dynamics of a broad scope of synthetically underdeveloped materials, including those with low exciton quantum yields and poor fluorescence stability. Here in this study, we have applied this method to measure weak biexciton fluorescence in samples of visible-emitting InP/ZnS and InAs/ZnS core/shell nanocrystals, and to demonstrate that a rapid CdS shell growth procedure can markedly increase the biexciton fluorescence of CdSe nanocrystals.

36 MATERIALS SCIENCE↗

A disk-based dynamical mass estimate for the young binary AK SCO

We present spatially and spectrally resolved Atacama Large Millimeter/submillimeter Array (ALMA) observations of gas and dust in the disk orbiting the pre-main sequence (pre-MS) binary AK Sco. By forward-modeling the disk velocity field traced by CO J = 2–1 line emission, we infer the mass of the central binary, M{sub ∗}=2.49±0.10 M{sub ⊙}, a new dynamical measurement that is independent of stellar evolutionary models. Assuming the disk and binary are co-planar within ∼2°, this disk-based binary mass measurement is in excellent agreement with constraints from radial velocity monitoring of the combined stellar spectra. These ALMA results are also compared with the standard approach of estimating masses from the location of the binary in the Hertzsprung–Russell diagram, using several common pre-MS model grids. These models predict stellar masses that are marginally consistent with our dynamical measurement (at ∼2σ), but are systematically high (by ∼10%). These same models consistently predict an age of 18 ± 1 Myr for AK Sco, in line with its membership in the Upper Centaurus–Lupus association but surprisingly old for it to still host a gas-rich disk. As ALMA accumulates comparable data for large samples of pre-MS stars, the methodology employed here to extract a dynamical mass from the disk rotation curve should prove extraordinarily useful for efforts to characterize the fundamental parameters of early stellar evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Helium-electrospray improves sample delivery in X-ray single-particle imaging experiments

Abstract Imaging the structure and observing the dynamics of isolated proteins using single-particle X-ray diffractive imaging (SPI) is one of the potential applications of X-ray free-electron lasers (XFELs). Currently, SPI experiments on isolated proteins are limited by three factors: low signal strength, limited data and high background from gas scattering. The last two factors are largely due to the shortcomings of the aerosol sample delivery methods in use. Here we present our modified electrospray ionization (ESI) source, which we dubbed helium-ESI (He-ESI). With it, we increased particle delivery into the interaction region by a factor of 10, for 26 nm-sized biological particles, and decreased the gas load in the interaction chamber corresponding to an 80% reduction in gas scattering when compared to the original ESI. These improvements have the potential to significantly increase the quality and quantity of SPI diffraction patterns in future experiments using He-ESI, resulting in higher-resolution structures.

Science & Technology - Other Topics↗

Measurement of elastic precursor decay in pre-heated aluminum films under ultra-fast laser generated shocks

Here, this article presents results from laser-driven shock compression experiments performed on pre-heated pure aluminum films at temperatures ranging from 23 to 400 °C. The samples were vapor deposited on the surface of a 500 μm thick sapphire substrate and mounted onto a custom holder with an integrated ring-heater to enable variable initial temperature conditions. A chirped pulse amplified laser was used to generate a pulse for both shocking the films and for probing the free surface velocity using Ultrafast Dynamic Ellipsometry. The particle velocity traces measured at the free surface clearly show elastic and plastic wave separation, which was used to estimate the decay of the elastic precursor amplitude over propagation distances ranging from 0.278 to 4.595 μm. Elastic precursors (which also correspond to dynamic material strength under uniaxial strain) of increasing amplitudes were observed with increasing initial sample temperatures for all propagation distances, which is consistent with expectations for aluminum in a deformation regime where phonon drag limits the mobility of dislocations. The experimental results show peak elastic amplitudes corresponding to axial stresses of over 7.5 GPa; estimates for plastic strain-rates in the samples are of the order 10 9 /s. The measured elastic amplitudes at the micron length scales are compared with those at the millimeter length-scales using a two-parameter model and used to correlate the rate sensitivity of the dynamic strength at strain-rates ranging from 10 3 to 10 9 /s and elevated temperature conditions. The overall trend, as inferred from the experimental data, indicates that the temperature-strengthening effect decreases with increasing plastic strain-rates.

36 MATERIALS SCIENCE↗

Sample glue layer investigation and mitigation for laser induced prompt impulse experiments

Understanding longer timescale material reactions under dynamic stress loading is critical for applications in materials engineering, shock physics, and planetary science. Prompt impulse experiments generate lower pressures since the ablator—the material first removed by the laser—is thicker and farther from the diagnostic plane, capturing aggregate material responses from the initial shock wave, rarefaction waves, and later time effects. This complexity demands thorough material characterization and simulation support. Since traditional sample construction is specific to supported shock experiments, designing prompt impulse experiments requires reconsideration around target design and sample engineering. Here, we present sample preparation techniques, experimental investigations, and theoretical simulations to investigate glue layer impacts, aiming to standardize samples for consistent data at lower laser fluences. We find that glue layers <30 μm have a minimal impact on peak velocity and pulse shape. The peak velocity scales linearly with glue layer thickness until a glue layer of 75 μm. For glue layers >75 μm, the peak velocity no longer scales with thickness; however, the pulse shape continues to degrade as described by simulations.

Lasers↗

A combined ensemble-volume average homogenization method for lattice structures with defects under dynamic and static loading

In the study of lattices structures, both experiments and numerical simulations are often conducted with small samples. Using combined ensemble and volume averaging, this work introduces a method to extract a macroscopic constitutive response of a lattice material from numerical simulations performed in periodic domains. The domain size needed to obtain statistically accurate results is investigated. Similar to molecular dynamics, the concept of the virial stress is introduced after homogenized equations are derived using the ensemble averaging method. Under static conditions, the virial stress is shown to agree with the volume averaged solid stress. Using the homogenization method, constitutive relations for this stress can be obtained from systems with uniform strains. Application of such obtained constitutive relations to more general cases results in an error proportional to the square of the ratio between the lattice length scale and the macroscopic length scale. Taking advantage of this property, numerical simulations are performed in systems with a uniform gradient of the average velocity. The volume average method is then used to accelerate convergence when studying lattices with defects. To avoid the artificial numerical time scale from the size of a representative volume element divided by the wave speed, a numerical scheme is developed to enforce a spatially uniform velocity gradient within the computational domain while allowing fluctuations of the velocity or displacement to develop naturally. To account for probability distribution of lattice defects, the stress is calculated as the ensemble-volume averaged value. For dynamic systems, energy dissipation properties are also studied.

36 MATERIALS SCIENCE↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

Phase segregation dynamics in mixed-halide perovskites revealed by plunge-freeze cryo-electron microscopy

Mixed-halide lead perovskites, with photoexcited charge-carrier properties suitable for high-efficiency photovoltaics, hold significant promise for high-efficiency tandem solar cells. However, phase segregation under illumination, where an iodide-rich phase forms carrier trap states, remains a barrier to application. This study employs plunge-freeze cryoelectron microscopy to visualize nanoscale phase segregation dynamics in CsPb(Br x I 1–x ) 3 films. By rapidly freezing the illuminated samples, we preserve transient photoexcited ion distributions for high-resolution structural and compositional analysis at the nanoscale. Cryogenic scanning transmission electron microscopy (STEM) techniques (electron energy loss spectroscopy [EELS] and 4D-STEM) captured the dynamics of photo-induced iodine migration from grain boundaries to centers, identified the buildup of anisotropic strain, and captured the heterogeneous evolution of this process within a single grain. These findings provide insight into microscopic phase segregation mechanisms and their dynamics, enhancing our understanding of mixed-halide perovskite photostability.

42 ENGINEERING↗

A sub-sampled approach to extremely low-dose STEM

The inpainting of deliberately and randomly sub-sampled images offers a potential means to image specimens at a high resolution and under extremely low-dose conditions (≤1 e - /Å 2 ) using a scanning transmission electron microscope. We show that deliberate sub-sampling acquires images at least an order of magnitude faster than conventional low-dose methods for an equivalent electron dose. More importantly, when adaptive sub-sampling is implemented to acquire the images, there is a significant increase in the resolution and sensitivity which accompanies the increase in imaging speed. Lastly, we demonstrate the potential of this method for beam sensitive materials and in-situ observations by experimentally imaging the node distribution in a metal-organic framework.

47 OTHER INSTRUMENTATION↗

Study of the water dynamics near hydrophilic, nanostructured CuO surfaces by quasielastic and inelastic neutron scattering

We have used quasielastic and inelastic neutron scattering to investigate the structure, dynamics, and phase transitions of water interacting with superhydrophilic CuO surfaces that not only possess a strong affinity for water but also a “grass-like” topography that is rough on both micro- and nanoscales. Here, we report quasielastic neutron scattering (QENS) measurements on two samples differing in water content at five temperatures below 280 K. The QENS spectra show water undergoing two different types of diffusive motion near the CuO surfaces: a “slow” translational diffusion occurring on a nanosecond time scale and a faster rotational motion. Further from the surfaces, there is “fast” translational diffusion comparable in rate to that of bulk supercooled water and the rotational motion occurring in the interfacial water. Analysis of the QENS spectra supports wetting of water to the CuO blades as seen in electron microscopy images. In addition, we observe an anomalous temperature dependence of the QENS spectra on cooling from 270 to 230 K with features consistent with a liquid–liquid phase transition. We suggest that the solvent-like properties of the coexisting bulk-like water in our CuO samples are a significant factor in determining the temperature dependence of the interfacial water’s dynamics. Our results are compared with those obtained from two well-studied substrate classes: (1) silicas that contain ordered cylindrical nanopores but have weaker hydrophilicity and (2) nanoparticles of other transition-metal oxides, such as TiO 2 , which share the strong hydrophilicity of our samples but lack their porosity.

36 MATERIALS SCIENCE↗

Study of Chemical Changes in Uranium Oxyfluoride Particles Progress Report June 2008 - February 2009

The present study aims to demonstrate how knowledge of time-dependent changes in uranium oxyfluoride particles can benefit particle analyses for environmental sampling. Environmental sampling depends upon laboratory analysis of nuclear material that has often been exposed to the environment after it was produced. It is therefore important to understand how those environmental conditions might have changed the chemical composition of the material over time. To investigate this, we prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (IRMM-DG Joint Research Centre of the European Commission, Belgium). These UO{sub 2}F{sub 2} particles were prepared from the release and subsequent hydrolysis of UF{sub 6} gas, and were stored at LLNL in environmental chambers, set to different humidity, temperature and lighting conditions. An experimental plan was drafted to assess the number of analyses required to track the changes in particle composition, morphology, and structure. Due to its high spatial resolution and excellent transmission, the NanoSIMS secondary ion mass spectrometer at LLNL was found to be the optimal tool to measure individual oxyfluoride particles. This was confirmed by our participation in the inter-laboratory measurement campaign for particle analysis (NUSIMEP-6), organized by the IRMM in June last year. The reported uranium isotope ratios demonstrated the precision and accuracy of the NanoSIMS and ims 3f SIMS measurements at LLNL, and provided a high degree of confidence that the new measurements on the UO{sub 2}F{sub 2} samples will be of comparable high quality. As fluorine is known to be a chemically-sensitive compound, we measured the intensity of the fluorine secondary ions relative to the ions generated by the matrix to evaluate the rate of particle degradation under different environmental conditions. A relative sensitivity factor was empirically determined to convert these measurements to absolute fluorine concentrations. Additional measurements in selected uranium compounds were carried out to account for variations in matrix composition. Because of the complexity of both the SIMS instruments, as well as the nature of the samples, we spent a substantial amount of time on instrument training and instrument set up. The latest NanoSIMS measurements on the freshly-prepared UO{sub 2}F{sub 2} particles however, showed that we are on the right track when it comes to determining the chemical changes in individual uranium particles. At PNNL, several optical techniques including cryogenic laser-induced time-resolved U(VI) fluorescence micro-spectroscopy, Raman spectroscopy, and Fourier transform infrared spectroscopy will be applied to investigate molecular transformations of the particles. As a control, dynamic SIMS measurements will also be performed on a subset of the samples sent to PNNL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE JAMES CLERK MAXWELL TELESCOPE NEARBY GALAXIES LEGACY SURVEY. II. WARM MOLECULAR GAS AND STAR FORMATION IN THREE FIELD SPIRAL GALAXIES

We present the results of large-area {sup 12}CO J = 3-2 emission mapping of three nearby field galaxies, NGC 628, NGC 3521, and NGC 3627, completed at the James Clerk Maxwell Telescope as part of the Nearby Galaxies Legacy Survey. These galaxies all have moderate to strong {sup 12}CO J = 3-2 detections over large areas of the fields observed by the survey, showing resolved structure and dynamics in their warm/dense molecular gas disks. All three galaxies were part of the Spitzer Infrared Nearby Galaxies Survey sample, and as such have excellent published multiwavelength ancillary data. These data sets allow us to examine the star formation properties, gas content, and dynamics of these galaxies on sub-kiloparsec scales. We find that the global gas depletion time for dense/warm molecular gas in these galaxies is consistent with other results for nearby spiral galaxies, indicating this may be independent of galaxy properties such as structures, gas compositions, and environments. Similar to the results from The H I Nearby Galaxy Survey, we do not see a correlation of the star formation efficiency with the gas surface density consistent with the Schmidt-Kennicutt law. Finally, we find that the star formation efficiency of the dense molecular gas traced by {sup 12}CO J = 3-2 is potentially flat or slightly declining as a function of molecular gas density, the {sup 12}CO J = 3-2/J = 1-0 ratio (in contrast to the correlation found in a previous study into the starburst galaxy M83), and the fraction of total gas in molecular form.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimating Power System Dynamic States Using Extended Kalman Filter

Abstract—The state estimation tools which are currently deployed in power system control rooms are based on a steady state assumption. As a result, the suite of operational tools that rely on state estimation results as inputs do not have dynamic information available and their accuracy is compromised. This paper investigates the application of Extended Kalman Filtering techniques for estimating dynamic states in the state estimation process. The new formulated “dynamic state estimation” includes true system dynamics reflected in differential equations, not like previously proposed “dynamic state estimation” which only considers the time-variant snapshots based on steady state modeling. This new dynamic state estimation using Extended Kalman Filter has been successfully tested on a multi-machine system. Sensitivity studies with respect to noise levels, sampling rates, model errors, and parameter errors are presented as well to illustrate the robust performance of the developed dynamic state estimation process.

Huang, Zhenyu↗

FunDiff: diffusion models over function spaces for physics-informed generative modeling

Recent advances in generative modeling-particularly diffusion models and flow matching-have been widely used for synthesizing discrete data such as images and videos. However, adapting these models to physical applications remains challenging, as the quantities of interest are continuous functions governed by complex physical laws. To address this, we introduce FunDiff, an efficient and robust framework for generative modeling in function spaces. FunDiff combines a latent diffusion process with a function autoencoder architecture to handle input functions with varying discretizations, generates continuous functions that can be evaluated at arbitrary locations, and seamlessly incorporate physical priors. These priors are enforced through architectural constraints or physics-informed loss functions, ensuring that generated samples satisfy fundamental physical laws. We theoretically establish minimax optimality guarantees for density estimation in function spaces, demonstrating that diffusion-based estimators achieve optimal convergence rates under suitable regularity conditions. We further demonstrate the practical effectiveness of FunDiff across diverse applications in fluid dynamics and solid mechanics. Empirical results indicate that our method can generate physically consistent samples with high fidelity to the target distribution, and exhibit robustness to noisy and low-resolution data.

Wang, Sifan [Yale University, New Haven, CT (Unite↗

Propagation dynamics of femtosecond pulse through subwavelength metallic hole arrays

We have studied the frequency-dependent transmission time delay of femtosecond (fs) laser pulses through subwavelength hole arrays in aluminum films using the up-conversion technique. The pulse delays measured at different wavelengths mainly follow the far-field transmission profile of the surface-plasmon polariton (SPP) resonances. Temporal delays of 60 and 100 fs were found at the major SPP resonance in the single-layer and double-layer samples. A coupled-SPP transmission model is used to explain the temporal dynamics of the transmission process. Our experiment shows that the weak coupling between the SPP waves on different metal-dielectric interfaces leads to the large temporal delay of the transmitted pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of a Cyclone Using Multiphase Flow Computational Fluid Dynamics

The U.S. Department of Energy National Energy Technology Laboratory's (NETL) 50 kW th chemical looping reactor (CLR) has an underperforming cyclone, which was designed using empirical correlations. To improve the performance of this cyclone using computational fluid dynamics (CFD)-based modeling simulations, four critical design parameters including the vortex tube radius and length, barrel radius, and the inlet width and height were optimized. Here, NETL's open source multiphase flow with interphase exchange (MFiX) CFD code has been used to model a series of cyclones by systematically varying the geometric design parameters. To perform the optimization process, the surrogate modeling and sensitivity analysis followed by the optimization capability in nodeworks was used. The basic methodology for the process is to employ a statistical design of experiments (DOE) method to generate sampling simulations that fill the design space. Corresponding CFD models are then created, executed, and postprocessed. A response surface is created to characterize the relationship between input parameters and the quantities of interest (QoI). Finally, the CFD-surrogate is used by an optimization method to find the optimal design condition based on the objective and constraints prescribed. The resulting optimal cyclone has a larger diameter and longer vortex tube, a larger diameter barrel, and a taller and narrower solids inlet. The improved design has a predicted pressure drop 11 times lower than the original design while reducing the mass loss by a factor of 2.3.

42 ENGINEERING↗

Uncertainty Quantification in Vibro-Acoustics Diagnosis of Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic testing was used on these slabs to locate ASR damage within the reactive samples. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both the Vanderbilt and Alabama samples using multiple variables for damage detection and localization. The results from the data analysis of the vibro-acoustic testing on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. A major focus of this report is to quantify the uncertainty in the diagnosis due to multiple factors and uncertainty sources. The uncertainty quantification methodology presented in this report was applied to VAM-based diagnosis and prognosis. However, the methodology is general, and is capable of being applied to multiple technique that collect spatially distributed data. Future work needs to investigate the incorporation of uncertainty quantification in developing a robust Prognostics and Health Management framework. Digital image correlation is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete specimen at the University of Tennessee is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Motion of DNA-Au Nanoconjugates in Graphene Liquid Cell Electron Microscopy

Liquid-phase transmission electron microscopy (TEM) can probe and visualize dynamic events with structural or functional details at the nanoscale in a liquid medium. Prior efforts have focused on the growth and transformation kinetics of hard material systems, relying on their stability under electron beam. Our recently developed graphene liquid cell technique pushed the spatial resolution of such imaging to the atomic scale but still focused on growth trajectories of metallic nanocrystals. Here, we adopt this technique to imaging three-dimensional (3D) dynamics of soft materials instead, double strand (dsDNA) connecting Au nanocrystals as one example, at nanometer resolution. We show first that a graphene liquid cell can seal an aqueous sample solution of a lower vapor pressure than previously investigated well against the high vacuum in TEM. Then, from quantitative analysis of real time nanocrystal trajectories, we show that the status and configuration of dsDNA dictate the motions of linked nanocrystals throughout the imaging time of minutes. This sustained connecting ability of dsDNA enables this unprecedented continuous imaging of its dynamics via TEM. Moreover, the inert graphene surface minimizes sample-substrate interaction and allows the whole nanostructure to rotate freely in the liquid environment; we thus develop and implement the reconstruction of 3D configuration and motions of the nanostructure from the series of 2D projected TEM images captured while it rotates. In addition to further proving the nanoconjugate structural stability, this reconstruction demonstrates 3D dynamic imaging by TEM beyond its conventional use in seeing a flattened and dry sample. Altogether, we foresee the new and exciting use of graphene liquid cell TEM in imaging 3D biomolecular transformations or interaction dynamics at nanometer resolution.

3D motion↗