Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Capacity Gain in Li-Ion Cells with Silicon-Containing Electrodes

Silicon-containing lithium-ion batteries can exhibit capacity gain early in life, which makes forecasting future cell behavior difficult. We have observed these anomalous trends even in conditions where known mechanisms, such as overhang equalization and excessive electrolyte oxidation, are unlikely to be significant. Here, we combine simulations and experiments to analyze four cases that can produce increased capacity in Si cells. Three of these pathways relate to “break-in” processes, where improved mass and charge transport can lead to increased access to active electrode domains and decreased cell impedance. The fourth case occurs at high levels of prelithiation, when the positive electrode (PE) is completely replenished with Li + at the end of cell discharge. We show that the commonality among these mechanisms is that the underlying transformations change the potentials experienced by electrodes at the end of half-cycles, increasing the Li + inventory available to the cell. A quantitative framework to describe these effects is presented, enabling these ideas to be extended to other battery systems.

25 ENERGY STORAGE↗

Revealing the aging process of solid electrolyte interphase on SiOx anode

Abstract As one of the most promising alternatives to graphite negative electrodes, silicon oxide (SiO x ) has been hindered by its fast capacity fading. Solid electrolyte interphase (SEI) aging on silicon SiO x has been recognized as the most critical yet least understood facet. Herein, leveraging 3D focused ion beam-scanning electron microscopy (FIB-SEM) tomographic imaging, we reveal an exceptionally characteristic SEI microstructure with an incompact inner region and a dense outer region, which overturns the prevailing belief that SEIs are homogeneous structure and reveals the SEI evolution process. Through combining nanoprobe and electron energy loss spectroscopy (EELS), it is also discovered that the electronic conductivity of thick SEI relies on the percolation network within composed of conductive agents (e.g., carbon black particles), which are embedded into the SEI upon its growth. Therefore, the free growth of SEI will gradually attenuate this electron percolation network, thereby causing capacity decay of SiO x . Based on these findings, a proof-of-concept strategy is adopted to mechanically restrict the SEI growth via applying a confining layer on top of the electrode. Through shedding light on the fundamental understanding of SEI aging for SiO x anodes, this work could potentially inspire viable improving strategies in the future.

25 ENERGY STORAGE↗

Direct current injection and thermocapillary flow for purification of aligned arrays of single-walled carbon nanotubes

Aligned arrays of semiconducting single-walled carbon nanotubes (s-SWNTs) represent ideal configurations for use of this class of material in high performance electronics. Development of means for removing the metallic SWNTs (m-SWNTs) in as-grown arrays represents an essential challenge. Here, we introduce a simple scheme that achieves this type of purification using direct, selective current injection through interdigitated electrodes into the m-SWNTs, to allow their complete removal using processes of thermocapillarity and dry etching. Experiments and numerical simulations establish the fundamental aspects that lead to selectivity in this process, thereby setting design rules for optimization. Single-step purification of arrays that include thousands of SWNTs demonstrates the effectiveness and simplicity of the procedures. The result is a practical route to large-area aligned arrays of purely s-SWNTs with low-cost experimental setups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scalable tensor factorizations with incomplete data.

The problem of incomplete data - i.e., data with missing or unknown values - in multi-way arrays is ubiquitous in biomedical signal processing, network traffic analysis, bibliometrics, social network analysis, chemometrics, computer vision, communication networks, etc. We consider the problem of how to factorize data sets with missing values with the goal of capturing the underlying latent structure of the data and possibly reconstructing missing values (i.e., tensor completion). We focus on one of the most well-known tensor factorizations that captures multi-linear structure, CANDECOMP/PARAFAC (CP). In the presence of missing data, CP can be formulated as a weighted least squares problem that models only the known entries. We develop an algorithm called CP-WOPT (CP Weighted OPTimization) that uses a first-order optimization approach to solve the weighted least squares problem. Based on extensive numerical experiments, our algorithm is shown to successfully factorize tensors with noise and up to 99% missing data. A unique aspect of our approach is that it scales to sparse large-scale data, e.g., 1000 x 1000 x 1000 with five million known entries (0.5% dense). We further demonstrate the usefulness of CP-WOPT on two real-world applications: a novel EEG (electroencephalogram) application where missing data is frequently encountered due to disconnections of electrodes and the problem of modeling computer network traffic where data may be absent due to the expense of the data collection process.

99 GENERAL AND MISCELLANEOUS↗

Nanostructured Materials for High Efficiency Low Cost Solution-Processed Photovoltaics

The goal of the project was to develop a suite of materials coupled with processing technologies aimed at the fabrication of entirely solution-processed photovoltaic devices. Most of the emphasis in terms of innovation was placed on the transparent electrodes, widely considered a critical component of the solar cell in terms of cost and performance. The active layer technologies proposed hinged on the fabrication and deposition of semiconducting nanoparticles. The electrode development hit all the milestones proposed: by the end of the grant we were able to fabricate transparent and flexible electrodes with transmission over the solar spectrum higher than 85% and sheet resistance lower than 10 Ω/square. To the best of our knowledge, this is the highest-performance transparent electrode reported. Furthermore these electrodes were deposited by spray-coating, a large-area, low-cost deposition techniques. Hence the first main goal of the proposal, which was to find an alternative to ITO was successfully achieved. Organic photovoltaic devices were made with these electrodes having a performance indistinguishable from that of devices made on ITO (the industry standard), e.g. ~5% for P3HT:PCBM cells. We also innovated in the active-area part of the device where semiconducting inks were designed rather than nanoparticle suspensions. The process we selected, called air-stable ink rolling (AIR) allowed to deposit well-controlled films of ternary and quaternary II-VI semiconductors. Developing a new technology from scratch proved to be more challenging than anticipated and therefore we were not able to demonstrate a fully integrated device using our nanostructured high-performance transparent electrodes as well as AIR active layers. As a result, we did not achieve the second main goal of the proposal, which was to fabricate an entire cell using nanostructured materials. We were able to develop the components separately but did not integrate them in a device.

14 SOLAR ENERGY↗

Generating Control Commands From Gestures Sensed by EMG

An effort is under way to develop noninvasive neuro-electric interfaces through which human operators could control systems as diverse as simple mechanical devices, computers, aircraft, and even spacecraft. The basic idea is to use electrodes on the surface of the skin to acquire electromyographic (EMG) signals associated with gestures, digitize and process the EMG signals to recognize the gestures, and generate digital commands to perform the actions signified by the gestures. In an experimental prototype of such an interface, the EMG signals associated with hand gestures are acquired by use of several pairs of electrodes mounted in sleeves on a subject s forearm (see figure). The EMG signals are sampled and digitized. The resulting time-series data are fed as input to pattern-recognition software that has been trained to distinguish gestures from a given gesture set. The software implements, among other things, hidden Markov models, which are used to recognize the gestures as they are being performed in real time. Thus far, two experiments have been performed on the prototype interface to demonstrate feasibility: an experiment in synthesizing the output of a joystick and an experiment in synthesizing the output of a computer or typewriter keyboard. In the joystick experiment, the EMG signals were processed into joystick commands for a realistic flight simulator for an airplane. The acting pilot reached out into the air, grabbed an imaginary joystick, and pretended to manipulate the joystick to achieve left and right banks and up and down pitches of the simulated airplane. In the keyboard experiment, the subject pretended to type on a numerical keypad, and the EMG signals were processed into keystrokes. The results of the experiments demonstrate the basic feasibility of this method while indicating the need for further research to reduce the incidence of errors (including confusion among gestures). Topics that must be addressed include the numbers and arrangements of electrodes needed to acquire sufficient data; refinements in the acquisition, filtering, and digitization of EMG signals; and methods of training the pattern- recognition software. The joystick and keyboard simulations were chosen for the initial experiments because they are familiar to many computer users. It is anticipated that, ultimately, interfaces would utilize EMG signals associated with movements more nearly natural than those associated with joysticks or keyboards. Future versions of the pattern-recognition software are planned to be capable of adapting to the preferences and day-today variations in EMG outputs of individual users; this capability for adaptation would also make it possible to select gestures that, to a given user, feel the most nearly natural for generating control signals for a given task (provided that there are enough properly positioned electrodes to acquire the EMG signals from the muscles involved in the gestures).

Wheeler, Kevin R.↗

Quantitatively controlled electrophoretic deposition of nanocrystal films from non-aqueous suspensions

This study presents a novel method to correlate the mass and charge transfer kinetics during the electrophoretic deposition of nanocrystal films by using a purpose-built double quartz crystal microbalance combined with simultaneous current-measurement. Our data support a multistep process for film formation: generation of charged nanocrystal flux, charge transfer at the electrode, and polarization of neutral nanocrystals near the electrode surface. The polarized particles are then subject to dielectrophoretic forces that reduce diffusion away from the interface, generating a sufficiently high neutral particle concentration at the interface to form a film. The correlation of mass and charge transfer enables quantification of the nanocrystal charge, the fraction of charged nanocrystals, and the initial sticking coefficient of the particles. These quantities permit calculation of the film thickness, providing a theoretical basis for using concentration and voltage as process parameters to grow films of targeted thicknesses.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of high productivity medium current ion implanter 'EXCEED 3000AH Evo2'

High productivity medium current ion implanter 'EXCEED 3000AH Evo2' is developed. In semiconductor manufacturing field, improvement of the productivity is continuously required. Especially mass production lines recently tend to use low energy beam and 2 pass implant for higher throughput. The 'Evo2' has been developed in an effort to fulfill these requirements. The 'Evo2' increases low energy beam current by 150 to 250% by applying electrostatic einzel lens called 'V-lens' installed at the exit of the Collimator magnet. This lens is also able to control the beam incident angle by adjusting the upper and lower electrode's voltages independently. Besides, mechanical scanning speed is enhanced to minimize process time of 2 pass implant, while also frequency of the fast beam scanning is enhanced to keep dose uniformity. In addition, a vacuum pumping capability at the target chamber is enhanced to reduce a vacuum waiting time during processing photo-resist wafers. This improvement achieved to reduce process time by 40% for a specific recipe. Furthermore, a modified Indirectly Heated Cathode with electron active Reflection 2 (IHC-R2) ion source which has a long life time filament has been installed. These new elements and/or functions have realized typically 25% improvement of productivity compared to standard EXCEED, and also improve a precise implantation capability.

43 PARTICLE ACCELERATORS↗

Deposition of tungsten metal by an immersion process

A new multi-step, solution-phase method for the spontaneous deposition of tungsten from a room temperature ethereal solution is reported. This immersion process relies on the deposition of a sacrificial zinc coating which is galvanically displaced by the ether-mediated reduction of oxophilic WCl 6 . Subsequent thermal treatment renders a crystalline, metallic tungsten film. The chemical evolution of the surface and formation of a complex intermediate tungsten species is characterized by X-ray diffraction, infrared spectroscopy, and X-ray photoelectron spectroscopy. Efficient metallic tungsten deposition is first characterized on a graphite substrate and then demonstrated on a functional carbon foam electrode. The resulting electrochemical performance of the modified electrode is interrogated with the canonical aqueous ferricyanide system. A tungsten-coated carbon foam electrode showed that both electrode resistance and overall electrochemical cell resistance were reduced by 50%, resulting in a concomitant decrease in redox peak separation from 1.902 V to 0.783 V. Furthermore, this process promises voltage efficiency gains in electrodes for energy storage technologies and demonstrates the viability of a new route to tungsten coating for technologies and industries where high conductivity and chemical stability are paramount.

36 MATERIALS SCIENCE↗

Radiation-Insensitive Inverse Majority Gates

To help satisfy a need for high-density logic circuits insensitive to radiation, it has been proposed to realize inverse majority gates as microscopic vacuum electronic devices. In comparison with solid-state electronic devices ordinarily used in logic circuits, vacuum electronic devices are inherently much less adversely affected by radiation and extreme temperatures. The proposed development would involve state-of-the-art micromachining and recent advances in the fabrication of carbon-nanotube-based field emitters. A representative three-input inverse majority gate would be a monolithic, integrated structure that would include three gate electrodes, six bundles of carbon nanotubes (serving as electron emitters) at suitable positions between the gate electrodes, and an overhanging anode. The bundles of carbon nanotubes would be grown on degenerately doped silicon substrates that would be parts of the monolithic structure. The gate electrodes would be fabricated as parts of the monolithic structure by means of a double-silicon-on-insulator process developed at NASA's Jet Propulsion Laboratory. The tops of the bundles of carbon nanotubes would lie below the plane of the tops of the gate electrodes. The particular choice of shapes, dimensions, and relative positions of the electrodes and bundles of carbon nanotubes would provide for both field emission of electrons from the bundles of carbon nanotubes and control of the electron current to obtain the inverse majority function, which is described in the paper.

Manohara, Harish↗

Probing Depth-Dependent Transition-Metal Redox of Lithium Nickel, Manganese, and Cobalt Oxides in Li-Ion Batteries

Layered lithium nickel, manganese, and cobalt oxides (NMC) are among the most promising commercial positive electrodes in the past decades. Understanding the detailed surface and bulk redox processes of Ni-rich NMC can provide useful insights into material design options to boost reversible capacity and cycle life. Both hard X-ray absorption (XAS) of metal K-edges and soft XAS of metal L-edges collected from charged LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) and LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) showed that the charge capacity up to removing ~0.7 Li/f.u. was accompanied with Ni oxidation in bulk and near the surface (up to 100 nm). Of significance to note is that nickel oxidation is primarily responsible for the charge capacity of NMC622 and 811 up to similar lithium removal (~0.7 Li/f.u.) albeit charged to different potentials, beyond which was followed by Ni reduction near the surface (up to 100 nm) due to oxygen release and electrolyte parasitic reactions. Overall, this observation points toward several new strategies to enhance reversible redox capacities of Ni-rich and/or Co-free electrodes for high-energy Li-ion batteries.

25 ENERGY STORAGE↗

Effect of the Nature of Both Cation and Anion Substitution on the Structural Symmetry of Li‐Rich 3 d ‐Metal Chalcogenide Electrodes

Abstract Li‐rich layered chalcogenides have recently led to better understanding of the anionic redox process and its associated high capacity while providing ways to overcome its practical limitations of voltage fade and irreversibility. This study reports on the feasibility of triggering anionic activity in Li 2 TiS 3 , through anionic substitution (Se for S) or cationic substitution (Fe for Ti). Herein, the chalcogenide chemical space is further explored to prepare mono‐substituted Li 1.7 Ti 0.85 Mn 0.45 Ch 3 (Ch = S/Se) and doubly substituted cationic and anionic phases (Li 1.7 Ti 0.85 Fe 0.45 S 3‐z Se z ) which crystallize either in the O3‐ or O1‐type structures depending upon substituents. All series show a bell‐shape capacity variation as function of the transition metal (TM) substitution degree with values up to 240 mAh g −1 . For specific compositions, a structural O3 to O1 phase transition is observed upon Li removal, which is not reversible upon Li re‐insertion due to kinetic limitations and negatively affects long‐term cycling performance. Density functional theory (DFT) calculations confirm the O3/O1 relative stability along the different series and point subtle electronic differences in the TM‐doping, rationalizing the structural and electrochemical behaviors of these phases upon cycling. These findings provide further insights into the link between structural and electronic stability, which is of key importance for designing chalcogenide‐based anionic redox compounds.

Chemistry↗

Quantitative Effects of Disorder on Chemically Modified Amorphous Carbon Electrodes

Real materials are disordered. This disorder influences the properties of these materials and the chemical processes that occur at their interfaces. Gaining a molecular-level understanding of the underlying physical manifestations caused by disordered materials is crucial to unraveling and ultimately controlling the efficiency and performance of these materials in a range of energy-related devices. This understanding necessitates measurement techniques through which disorder can be detected, quantified, and monitored. However, such quantitative measurements are notoriously difficult, as effects often average out in ensemble measurements. In this work, we describe how a combination of electrochemical and spatially resolved surface spectroscopy measurements illuminate a molecular-level picture of disorder in materials. Using amorphous carbon as an intrinsically disordered material, we covalently attached a monolayer of ferrocene. Interfacial electron transfer across the amorphous carbon–ferrocene interface is highly sensitive to disruptions of order. Here, by systematically varying linker properties and surface loadings, the influence of lateral interactions between nonuniformly distributed ferrocene headgroups on ensemble electrochemical measurements is demonstrated. Electrochemical and imaging data collectively indicate that conformational flexibility of the ferrocene moieties provides a mechanism to elude repulsive and unbalanced lateral interactions, while rigid linkages provide direct information about the underlying disorder of the material. This study is the first of its kind to quantify and visualize molecular disorder and heterogeneity with an experimental model accessed through ensemble measurements.

36 MATERIALS SCIENCE↗

Self-aligned nanostructures created by swift heavy ion irradiation

In tetrahedral amorphous carbon (ta-C) swift heavy ions create conducting tracks of about 8 nm in diameter. To apply these nanowires and implement them into nanodevices, they have to be contacted and gated. In the present work, we demonstrate the fabrication of conducting vertical nanostructures in ta-C together with self-aligned gate electrodes. A multilayer assembly is irradiated with GeV heavy ions and subsequently exposed to several selective etching processes. The samples consist of a Si wafer as substrate covered by a thin ta-C layer. On top is deposited a SiN{sub x} film for insulation, a Cr layer as electrode, and finally a polycarbonate film as ion track template. Chemical track etching opens nanochannels in the polymer which are self-aligned with the conducting tracks in ta-C because they are produced by the same ions. Through the pores in the polymer template, the Cr and SiN{sub x} layers are opened by ion beam sputtering and plasma etching, respectively. The resulting structure consists of nanowires embedded in the insulating carbon matrix with a built in gate electrode and has potential application as gated field emission cathode.

36 MATERIALS SCIENCE↗

Investigation of field induced trapping on floating gates

The development of a technology for building electrically alterable read only memories (EAROMs) or reprogrammable read only memories (RPROMs) using a single level metal gate p channel MOS process with all conventional processing steps is outlined. Nonvolatile storage of data is achieved by the use of charged floating gate electrodes. The floating gates are charged by avalanche injection of hot electrodes through gate oxide, and discharged by avalanche injection of hot holes through gate oxide. Three extra diffusion and patterning steps are all that is required to convert a standard p channel MOS process into a nonvolatile memory process. For identification, this nonvolatile memory technology was given the descriptive acronym DIFMOS which stands for Dual Injector, Floating gate MOS.

Gosney, W. M.↗

Characterization of Unimorph-Membrane Microactuators and Error-Analysis of the Characterization Process

Microactuators are versatile, low-cost, low-mass electrical-mechanical devices that can be used in many applications. Microactuators consist of two electrodes sandwiching a PZT (piezo-electric) film between them. The centers of the microactuators deflect when a voltage is applied across the electrodes. In order to correctly apply this technology for use, it is important to fully characterize the actuation behavior. Measuring the deflection profile as a function of the voltage of various microactuators is crucial. This measurement process has errors associated with it, so it is being studied to determine the accuracy of the data. In certain applications, microactuators may undergo many cycles of deflection; testing various microactuators through many cycles of deflection simulates these circumstances. However, due to an unknown issue, many of the microactuators exhibit defects that cause them to fail when voltage is applied to their electrodes. These defects do not allow for the acquisition of significant deflection profiles. Vibrations are the largest cause of error in deflection measurements, and the microactuators withstand continuous cycles of deflection, yet the cause of damage is still to be determined. Future projects will be needed to characterize the deflection profiles of various microactuators and to overcome the defects in the microactuators that are currently present.

Wright, Matthew W.↗