Search NASA⌕ Search

SEARCH · Search NASA

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Noise Constraints on Sensitivity Scaling in Quantum Nonlinear Metrology

Quantum-enhanced metrology surpasses classical metrology by improving estimation precision scaling with a resource 𝑁 (e.g., particle number or energy) from 1/√𝑁 to 1/𝑁. Through the use of nonlinear effects, Roy and Braunstein [Exponentially enhanced quantum metrology, Phys. Rev. Lett. 100, 220501 (2008)] derived a 1/𝑁 2 scaling. However, later works argued this exponential improvement is unphysical and that even modest gains, like 1/𝑁 2 , may vanish under noise. We show that, in the presence of small errors, the nonlinear interactions enabling metrological enhancement induce emergent errors. Here, the errors propagate through the sensing protocol and are magnified proportional to any intended nonlinear enhancement. We identify a critical value of the parameter to be estimated, for a fixed error, below which the emergent errors can be avoided.

Quantum Fisher information↗

Constant-Overhead Fault-Tolerant Bell-Pair Distillation Using High-Rate Codes

We present a fault-tolerant Bell-pair distillation scheme achieving constant overhead through high-rate quantum low-density parity-check (qLDPC) codes. Our approach maintains a constant distillation rate equal to the code rate while requiring no additional overhead beyond the physical qubits of the code. Full circuit-level analysis demonstrates fault-tolerance for input Bell-pair infidelities below a threshold ∼10%, readily achievable with near-term capabilities. Unlike previous proposals, our scheme keeps the output Bell pairs encoded in qLDPC codes at each node, eliminating unencoding overhead and enabling direct use in distributed quantum applications through recent advances in qLDPC computation. These results establish qLDPC-based distillation as a practical route toward resource-efficient quantum networks and distributed quantum computing.

quantum communication, protocols & technology↗

Controlling X-ray deformable mirrors during inspection

The X-ray deformable mirror (XDM) is becoming widely used in the present synchrotron/free-electron laser facilities because of its flexibility in correcting wavefront errors or modification of the beam size at the sample location. Owing to coupling among the N actuators of an XDM, (N + 1) or (2N + 1) scans are required to learn the response of each actuator one by one. When the mirror has an important number of actuators (N) and the actuator response time including stabilization or the necessary metrology time is long, the learning process can be time consuming. In this paper, a fast and accurate method is presented to drive an XDM to a target shape usually with only three or four measurements during inspection. The metrology data are used as feedback to calculate the curvature discrepancy between the current and the target shapes. Three different derivative estimation methods are introduced to calculate the curvature from measured data. The mirror shape is becoming close to the target through iterative compensations. Finally, the feasibility of this simple and effective approach is demonstrated by a series of experiments.

42 ENGINEERING↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel fabrication technique for high-resolution spherical crystal analyzers using a microporous aluminium base

Modern inelastic X-ray spectrometers employ curved, bent and diced analyzers to capture sufficiently large solid angles of radially emitted scattered radiation emanating from the sample. Fabricating these intricate analyzers, especially when a high energy resolution of a few millielectronvolts is required, is very time-consuming, expensive and often a hit-or-miss affair. A novel fabrication technique is introduced, utilizing a concave-spherical, microporous aluminium base to hold an assembly of a thin glass substrate with a diced crystal wafer bonded to it. Under uniform vacuum forces, the glass substrate is drawn into the aluminium base, achieving the desired bending radius, while dicing of the diffracting crystal layer prevents bending strain from being imposed on the individual crystal pixels. This technique eliminates the need for permanently bonding the crystal assembly to the concave lens, offering the opportunity for correcting figure errors, avoiding long-term degradation of the permanent bond, and making both lens and crystal reusable. Process and material costs are thus substantially decreased. Two analyzers, Si(844) and Ge(337) with intrinsic resolutions of 14.6 meV and 36.5 meV, respectively, were produced in this fashion and characterized in resonant inelastic X-ray scattering (RIXS) measurements. The achieved overall energy resolutions for both analyzers were 29.4 meV for Si(844) and 56.6 meV for Ge(337). Although the RIXS technique is veru sensitive to analyzer imperfections, the analyzers were found to be equal, if not superior, in quality to their traditional, permanently bonded counterparts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Solovay-Kitaev Algorithm and Randomized Compilation Data Availability

This zipped folder contains simulation notebooks, simulated data, and experimental data from the QSCOUT trapped-ion device that were used in the publication "Solovay-Kitaev Algorithm and Randomized Compilation" (https://doi.org/10.1103/ll6m-dbl7). The raw data is in the form of measurement outcomes of simple tomographic quantum circuits that were executed on the QSCOUT device and simulated using JAQALPAQ. These data are used to create plots within the jupyter notebooks that were included in the publication.

Quantum benchmarking↗

Metabolites Annotations and Genes Integrated (MAGI) v1.0

With the benefit of hindsight, it is easy to see that the readout of the human genome, spectacular milestone that it was, represents only the beginning of the "omics" information explosion. The technical side of the 'omics explosion--enabling researchers to efficiently readout terabytes of information spelling out whole genomes, transcriptomes, proteomes and metabolomes, does not per se provide a clear picture of how life works. Nor does it show us how we can engineer biology to solve the grand challenges of the 21st century: feeding 10 billion people with declining per capita supplies of arable land and clean water, sustaining biological diversity and slowing the increase in greenhouse gas formation, primarily carbon dioxide and methane. The 2017-063 invention--Metabolites and Genes Integration Technology--proposes an integrated approach to correcting and connecting the dots of the 'omics explosion: linking genes to proteins, proteins to pathways, pathways to biochemical reactions and metabolites. The '063 invention is potentially transformational in that it can generate testable hypotheses across thousands of genes to predict their chemical and metabolic products. It can also do the reverse; i.e., starting from chemical and metabolic products it can generate testable hypotheses about which genes and pathways those molecules are linked to. Since we know that genomic, transcriptomic, proteomic and metabolomic databases are chock full or erroneous information, MAGI also has the unique benefit of correcting these errors through its own independent pathway of bidirectional hypothesis generation (genes=>proteins=>metabolites + metabolites=>proteins=>genes). Perfectly amenable to high-throughput hypothesis generation and experimentation, MAGI can transform our understanding of human, animal, plant and microbial biology over several decades, laying the essential knowledge foundation to addressing the grand scientific challenges of the 21st century.

Bowen, Benjamin↗

An Interactive Spectral Analysis Tool for Chemical Identification and Quantification of Gas-Phase Species in Complex Spectra

A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm –1 ) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.

Thompson, Christopher J.↗

Bayesian homodyne and heterodyne tomography: erratum

We correct typographical errors in Eq. (15) in [ Opt. Express 30 , 15184 ( 2022 ) 10.1364/OE.456597 ]. These errors were not present in the actual formulas used to calculate the results of the paper, so all results remain unaffected.

Chapman, Joseph C. (ORCID:0000000233460914)↗

E-PVT: enhanced position-velocity-time scheduler for computer-controlled optical finishing with comprehensive considerations of dynamics constraints, continuity and efficiency

Deterministic computer-controlled optical finishing is an essential approach for achieving high-quality optical surfaces. Its determinism and convergence rely heavily on precise and smooth motion control to guide the machine tool over an optical surface to correct residual errors. One widely supported and smooth motion control model is position-velocity-time (PVT), which employs piecewise cubic polynomials to describe positions. Our prior research introduced a PVT-based velocity scheduling method, demonstrating sub-nanometer level convergence in ion beam figuring (IBF) processes. However, three challenges remained. Firstly, this method relies on quadratic programming, resulting in computational intensiveness for dense tool paths. Secondly, the dynamics constraints and velocity and acceleration continuities are not comprehensively considered, limiting the full potential of PVT-based control. Thirdly, no compensation mechanism existed when dynamics constraints are exceeded. In this study, in response to these challenges, we proposed the Enhanced PVT (E-PVT) method, reducing the time complexity from O ( n 3 ) to O ( n ) while fully addressing dynamics constraints and continuities. A novel compensation method utilizing particle swarm optimization was proposed to address situations where dynamics constraints might be exceeded while maintaining the overall processing efficiency. Validation through simulation and experimentation confirmed the improved performance of E-PVT.

36 MATERIALS SCIENCE↗

CCSI Toolset 3.22 Release

CCSI Toolset 3.22 Release Highlights The Sequential Design of Experiments user interface was updated to resolve an issue where the results would fail to plot in some cases (e.g., Non-Uniform Space Filling designs). The Machine Learning/Artificial Intelligence module was updated to support Keras 3 and to reflect changes made to dependencies’ syntax. A check was added to ensure PSUADE is installed and available at FOQUS startup. If PSUADE is not installed, a link to the FOQUS documentation is displayed and FOQUS is closed. The copyright year was updated to include 2024 in places where it had not previously been updated. Typographical errors were corrected to improve clarity in variable names and documentation. The FOQUS documentation was updated to reflect the fact that ALAMO can have two executables and indicates the correct executable to add to the Settings path. SimSinter was updated to version 3.1.0. This version removed gPROMS support and included security updates.

AS↗

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator ↗

Parton Dynamics Inferred from High-Mass Drell-Yan Dimuons Induced by 120 GeV p+D Interactions

Fermilab Experiment 906/SeaQuest (E906/SeaQuest) is the latest in a well established tradition of studying leptoproduction from the annihilation of a quark and anti-quark, known as the Drell-Yan process. The broad goal of E906/SeaQuest is measuring various properties of nucleon structure in order to learn more about quarks and Quantum Chromodynamics (QCD), the mathematical description of the strong force. The present work investigated violations of the Lam-Tung relation between virtual photon polarization and quark and lepton angular momentum. The violation of Lam-Tung can be explained as the signature of quark-nucleon spin-orbit coupling through the use of the Transverse-Momentum-Dependent (TMD) framework, which assumes that the initial transverse momentum of quarks is smaller than the hard scattering scale, but also non-negligible. An analysis of the angular moments in Drell-Yan collected by E906/SeaQuest was performed with four different configurations in order to estimate the systematic errors attributed to each correction. After correction for background and error propagation, the final extraction of the azimuthal moment excluding contributions from the trigger was ν = 0.151 ± 0.88(stat.) ± 0.346(syst.) at an average transverse momentum of 0.87 ± 0.50 GeV/c and an average dimuon mass of 5.48 ± 0.70 GeV. In the future, the magnitude of the systematic errors on the extraction could potentially be reduced by improving the quality of the trigger efficiency calculation, improving the intensity dependent event reconstruction efficiency, considering the changes in acceptance due to a beam shift relative to the E906/SeaQuest spectrometer, and improving the modeling of background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scattering Angular Distributions in the ENDF/B Nuclear Data Library

Nuclear reactors function by controlling the chain reaction of fission events in a fissile material. Understanding the gain and loss of neutrons is crucial for controlling this chain reaction. The role of fission in liberating neutrons from nuclei is well known. The fact that neutrons can scatter out of a reactor and therefore be lost is less well appreciated. Scattering can happen within fissile fuel or off of any number of the non-fissile structural components holding a reactor together. The scattering angular distributions for reactor material are the quantity that give the probability for a particle (usually a neutron) to scatter off a nucleus into a given angle. The Evaluated Nuclear Data File/B (ENDF/B) nuclear data library is the most complete and authoritative reference for neutron scattering data, containing reaction cross sections and outgoing particle distributions (including scattering angular distributions). In this project, we will compare the scattering angular distributions given in these ENDF/B data sets with those that can be derived using the Blatt-Biedenharn formalism and the resolved resonance data also in the ENDF/B files. More comparisons between the scattering angular distributions of relevant isotopes will help identify and correct any errors in the ENDF/B files. The results of this study will be an important component of the next major release of the ENDF/B library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗