Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

User Directed Tools for Exploiting Expert Knowledge in an Immersive Segmentation and Visualization Environment

Volumetric data sets have become common in medicine and many sciences through technologies such as computed x-ray tomography (CT), magnetic resonance (MR), positron emission tomography (PET), confocal microscopy and 3D ultrasound. When presented with 2D images humans immediately and unconsciously begin a visual analysis of the scene. The viewer surveys the scene identifying significant landmarks and building an internal mental model of presented information. The identification of features is strongly influenced by the viewers expectations based upon their expert knowledge of what the image should contain. While not a conscious activity, the viewer makes a series of choices about how to interpret the scene. These choices occur in parallel with viewing the scene and effectively change the way the viewer sees the image. It is this interaction of viewing and choice which is the basis of many familiar visual illusions. This is especially important in the interpretation of medical images where it is the expert knowledge of the radiologist which interprets the image. For 3D data sets this interaction of view and choice is frustrated because choices must precede the visualization of the data set. It is not possible to visualize the data set with out making some initial choices which determine how the volume of data is presented to the eye. These choices include, view point orientation, region identification, color and opacity assignments. Further compounding the problem is the fact that these visualization choices are defined in terms of computer graphics as opposed to language of the experts knowledge. The long term goal of this project is to develop an environment where the user can interact with volumetric data sets using tools which promote the utilization of expert knowledge by incorporating visualization and choice into a tight computational loop. The tools will support activities involving the segmentation of structures, construction of surface meshes and local filtering of the data set. To conform to this environment tools should have several key attributes. First, they should be only rely on computations over a local neighborhood of the probe position. Second, they should operate iteratively over time converging towards a limit behavior. Third, they should adapt to user input modifying they operational parameters with time.

Senger, Steven O.↗

Securing Federated Learning Against Active Reconstruction Attacks

Federated Learning (FL) has amassed notable attention for its ability to preserve user privacy while emphasizing the retainment of model training efficiency. Due to this potential, FL has been integrated in many domains, such as healthcare, finance, law, and industrial engineering, where data cannot be easily exchanged due to sensitive information and strict privacy laws. However, current research has indicated that FL protocols are easily compromised by active data reconstruction attacks employed by actively dishonest servers. The malicious modification of global model parameters allows an actively dishonest server to obtain a direct copy of users’ private data via gradient inversion. Here, this class of attacks is highly underexplored and continues to be a major challenge due to the intense threat model. In this paper, we propose OASIS as a scalable and modality-agnostic defense based on data augmentation that counteracts active data reconstruction attacks while preserving model performance. To generalize our defense, we uncover the intuition behind gradient inversion that enables these attacks and theoretically establish the conditions by which the defense can be considered robust regardless of attack design. From this, we formulate our defense with data augmentation that illustrates its ability to undermine the attack principle. We evaluate OASIS on five real-world datasets–two image-based (ImageNet and CIFAR100) and three text-based (Wikitext, Stack Overflow, and Shakespeare)–which span diverse uses cases such as vision tasks and language modeling. Comprehensive evaluations on these datasets exhibit the efficacy of OASIS and highlight its feasibility as a solution.

97 MATHEMATICS AND COMPUTING↗

TU-CD-BRB-01: Normal Lung CT Texture Features Improve Predictive Models for Radiation Pneumonitis

Purpose: Existing normal tissue complication probability (NTCP) models for radiation pneumonitis (RP) traditionally rely on dosimetric and clinical data but are limited in terms of performance and generalizability. Extraction of pre-treatment image features provides a potential new category of data that can improve NTCP models for RP. We consider quantitative measures of total lung CT intensity and texture in a framework for prediction of RP. Methods: Available clinical and dosimetric data was collected for 198 NSCLC patients treated with definitive radiotherapy. Intensity- and texture-based image features were extracted from the T50 phase of the 4D-CT acquired for treatment planning. A total of 3888 features (15 clinical, 175 dosimetric, and 3698 image features) were gathered and considered candidate predictors for modeling of RP grade≥3. A baseline logistic regression model with mean lung dose (MLD) was first considered. Additionally, a least absolute shrinkage and selection operator (LASSO) logistic regression was applied to the set of clinical and dosimetric features, and subsequently to the full set of clinical, dosimetric, and image features. Model performance was assessed by comparing area under the curve (AUC). Results: A simple logistic fit of MLD was an inadequate model of the data (AUC∼0.5). Including clinical and dosimetric parameters within the framework of the LASSO resulted in improved performance (AUC=0.648). Analysis of the full cohort of clinical, dosimetric, and image features provided further and significant improvement in model performance (AUC=0.727). Conclusions: To achieve significant gains in predictive modeling of RP, new categories of data should be considered in addition to clinical and dosimetric features. We have successfully incorporated CT image features into a framework for modeling RP and have demonstrated improved predictive performance. Validation and further investigation of CT image features in the context of RP NTCP modeling is warranted. This work was supported by the Rosalie B. Hite Fellowship in Cancer research awarded to SPK.

60 APPLIED LIFE SCIENCES↗

Deep learning-driven super-resolution in Raman hyperspectral imaging: Efficient high-resolution reconstruction from low-resolution data

Deep learning (DL) has become an indispensable tool in hyperspectral data analysis, automatically extracting valuable features from complex, high-dimensional datasets. Super-resolution reconstruction, an essential aspect of hyperspectral data, involves enhancing spatial resolution, particularly relevant to low-resolution hyperspectral data. Yet, the pursuit of super-resolution in hyperspectral analysis is fraught with challenges, including acquiring ground truth high-resolution data for training, generalization, and scalability. The pressing issue of extended spectral acquisition times, notably for high-resolution scans, is a significant roadblock in hyperspectral imaging. Super-resolution methods offer a promising solution by providing higher spatial resolution data to expedite data collection and yield more efficient outcomes. This paper delves into a practical application of these concepts using Raman imaging, where spectral acquisition times can be prohibitively long. In this context, DL-based super-resolution models demonstrate their efficacy by predicting and reconstructing high-resolution Raman data from low-resolution input, eliminating the need for resource-intensive high-resolution scans. While previous work often relied on substantial high-resolution datasets, this study showcases the ability to achieve similar outcomes even with limited data, presenting a more practical and cost-effective approach. In conclusion, the results offer a glimpse into the transformative potential of this technology to streamline hyperspectral imaging applications by saving valuable time and resources through the successful generation of high-resolution data from low-resolution inputs.

42 ENGINEERING↗

MO-FG-CAMPUS-IeP1-02: Dose Reduction in Contrast-Enhanced Digital Mammography Using a Photon-Counting Detector

Purpose: Photon-counting detectors (PCDs) allow multi-energy X-ray imaging without additional exposures and spectral overlap. This capability results in the improvement of accuracy of material decomposition for dual-energy X-ray imaging and the reduction of radiation dose. In this study, the PCD-based contrast-enhanced dual-energy mammography (CEDM) was compared with the conventional CDEM in terms of radiation dose, image quality and accuracy of material decomposition. Methods: A dual-energy model was designed by using Beer-Lambert’s law and rational inverse fitting function for decomposing materials from a polychromatic X-ray source. A cadmium zinc telluride (CZT)-based PCD, which has five energy thresholds, and iodine solutions included in a 3D half-cylindrical phantom, which composed of 50% glandular and 50% adipose tissues, were simulated by using a Monte Carlo simulation tool. The low- and high-energy images were obtained in accordance with the clinical exposure conditions for the conventional CDEM. Energy bins of 20–33 and 34–50 keV were defined from X-ray energy spectra simulated at 50 kVp with different dose levels for implementing the PCD-based CDEM. The dual-energy mammographic techniques were compared by means of absorbed dose, noise property and normalized root-mean-square error (NRMSE). Results: Comparing to the conventional CEDM, the iodine solutions were clearly decomposed for the PCD-based CEDM. Although the radiation dose for the PCD-based CDEM was lower than that for the conventional CEDM, the PCD-based CDEM improved the noise property and accuracy of decomposition images. Conclusion: This study demonstrates that the PCD-based CDEM allows the quantitative material decomposition, and reduces radiation dose in comparison with the conventional CDEM. Therefore, the PCD-based CDEM is able to provide useful information for detecting breast tumor and enhancing diagnostic accuracy in mammography.

60 APPLIED LIFE SCIENCES↗

An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy

Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. Conclusions: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Accurate shear estimation with fourth-order moments

ABSTRACT As imaging surveys progress in exploring the large-scale structure of the Universe through the use of weak gravitational lensing, achieving sub-per cent accuracy in estimating shape distortions caused by lensing, or shear, is imperative for precision cosmology. In this paper, we extend the Fourier power function shapelets (FPFS) shear estimator using fourth-order shapelet moments and combine it with the original second-order shear estimator to reduce galaxy shape noise. We calibrate this novel shear estimator analytically to a sub-per cent level-accuracy using the AnaCal framework. This higher order shear estimator is tested with realistic image simulations, and after analytical correction for the detection/selection bias and noise bias, the multiplicative shear bias $|m|$ is below $3\times 10^{-3}$ (99.7 per cent confidence interval) for both isolated and blended galaxies. Once combined with the second-order FPFS shear estimator, the shape noise is reduced by $\sim 35~{{\ \rm per\ cent}}$ for isolated galaxies in simulations with Hyper Suprime-Cam and Vera C. Rubin Observatory Legacy Survey of Space and Time observational conditions. However, for blended galaxies, the effective number density does not significantly improve with the combination of the two estimators. Based on these results, we recommend exploration of how this framework can further reduce the systematic uncertainties in shear due to point spread function leakage and modelling error, and potentially provide improved precision in shear inference in high-resolution space-based images.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-CD-BRB-08: Radiomic Analysis of FDG-PET Identifies Novel Prognostic Imaging Biomarkers in Locally Advanced Pancreatic Cancer Patients Treated with SBRT

Purpose: This study aims to identify novel prognostic imaging biomarkers in locally advanced pancreatic cancer (LAPC) using quantitative, high-throughput image analysis. Methods: 86 patients with LAPC receiving chemotherapy followed by SBRT were retrospectively studied. All patients had a baseline FDG-PET scan prior to SBRT. For each patient, we extracted 435 PET imaging features of five types: statistical, morphological, textural, histogram, and wavelet. These features went through redundancy checks, robustness analysis, as well as a prescreening process based on their concordance indices with respect to the relevant outcomes. We then performed principle component analysis on the remaining features (number ranged from 10 to 16), and fitted a Cox proportional hazard regression model using the first 3 principle components. Kaplan-Meier analysis was used to assess the ability to distinguish high versus low-risk patients separated by median predicted survival. To avoid overfitting, all evaluations were based on leave-one-out cross validation (LOOCV), in which each holdout patient was assigned to a risk group according to the model obtained from a separate training set. Results: For predicting overall survival (OS), the most dominant imaging features were wavelet coefficients. There was a statistically significant difference in OS between patients with predicted high and low-risk based on LOOCV (hazard ratio: 2.26, p<0.001). Similar imaging features were also strongly associated with local progression-free survival (LPFS) (hazard ratio: 1.53, p=0.026) on LOOCV. In comparison, neither SUVmax nor TLG was associated with LPFS (p=0.103, p=0.433) (Table 1). Results for progression-free survival and distant progression-free survival showed similar trends. Conclusion: Radiomic analysis identified novel imaging features that showed improved prognostic value over conventional methods. These features characterize the degree of intra-tumor heterogeneity reflected on FDG-PET images, and their biological underpinnings warrant further investigation. If validated in large, prospective cohorts, this method could be used to stratify patients based on individualized risk.

60 APPLIED LIFE SCIENCES↗

Comparison of special sensor microwave imager vector wind stress with model-derived and subjective products for the tropical Pacific

An assessment of a new source of vector wind stress data relative to existing analyses of the surface wind field is presented. The large-scale variability of vector wind stress generated by Atlas et al. (1991) and based on the special sensor microwave imager (SSM/I) remotely sensed observations of surface wind speed is compared with five operational and subjectively analyzed wind products across the tropical Pacific basin for the first year of SSM/I, July 1987 through June 1988. The spatial and temporal variability of the zonal component, meridional component, and curl of the wind stress are examined relative to their future use in wind-driven ocean model studies of tropical Pacific Ocean circulation.

Busalacchi, Antonio J.↗

Surface Chemistry and Reactions for Bimetallic Au Catalysis (Final Report)

Gold-based catalysts offer tremendous opportunities for developing new technologies for selective oxidation reactions that directly use gas-phase oxygen as a benign reagent and produce either no byproducts or water as the only byproduct. These processes are urgently needed and critical for achieving the sustainable production of chemicals. While recent studies demonstrate that the catalytic properties of gold can be significantly enhanced by addition of other metals, the development of these catalysts with sufficient performance for commercialization is hindered by a lack of fundamental understanding of how the catalytic properties of gold can be controlled and tailored. This project addressed this need by synergistically combining experimental and computational studies to establish fundamental composition-structure-activity relationships for gold-based catalysts for several industrially important reactions. Results from surface spectroscopy, atomic imaging and thermal desorption experiments were combined with molecular models and reaction mechanisms from quantum chemical calculations to link observable reaction rates to the structure and composition of surfaces at the molecular level. The results were used to develop improved catalyst formulations and identify optimized reaction conditions for gold-based catalysts. For broader impacts, the developed methodology was extended to other metallic catalysts, such as silver, platinum-molybdenum and nickel-tin, for improved catalytic efficiency and sustainable production of specialty and commodity chemicals.

36 MATERIALS SCIENCE↗

SU-E-T-116: Dose Response in the Treatment of Unresectable Cholangiocarcinoma with Yttrium-90 Microspheres

Purpose: The purpose of this study is to assess the dose response of radioembolization using yttrium-90 (Y-90) microspheres in patients treated for unresectable cholangiocarcinoma. This study utilized partition dosimetry model for the dose calculation. The results show survival benefit with dose escalation. Methods: Between February 2009 and March 2013, ten patients with pathology proven unresectable cholangiocarcinoma were radioembolized with Y-90 microspheres. Patients underwent initial pre-treatment angiographic assessment for blood flow and 99mTc- MAA for lung shunt evaluation. Activity of Y-90 administration was calculated using the Body Surface Area (BSA) and target volumes which were determined by contouring the pre-treatment MRI/CT images using a radiation therapy treatment planning system. Medical Internal Radiation Dose (MIRD) method was used to assess the dosimetric results of Y90. Partition model based on the tumor to-liver activity uptake estimated from pretreatment 99mTc- MAA study was used to calculate the dose delivered to the target. The variables assessed included: administered dose, toxicity based on clinical changes, imaging based tumor response, and survival. Results: Ten patients were radioembolized with Y-90 microspheres to either one hepatic lobe or both left and right lobes. Patients were stratified by dose. Four patients who received dose greater than 140Gy (p < 0.05) all survived. The corresponding activity they received was greater than 35 mCi. Six out of ten patients died of disease with median survival of 18 weeks (range 12–81wks). Conclusion: Given the growing body of data for Y-90 microspheres in the context of cholangiocarcinoma, radioembolization may become an important treatment modality for an appropriately selected group of patients. Our study further substantiates past studies and shows additional evidence of a survival benefit with dose escalation.

60 APPLIED LIFE SCIENCES↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗

Radiation-induced Swelling and Microcracking in SiC Cladding for LWRs

After the Fukushima accident in 2011, SiC has attracted considerable attention as a potential material for fuel cladding that can offer increased accident tolerance in light water reactors (LWRs) compared to zircaloy cladding. Existing measurements on nuclear grade SiC/SiC composites made of high-purity, stoichiometric SiC have already shown very good radiation tolerance in various harsh environments. However, there are a number of challenges that need to be addressed before SiC composites can be successfully used in LWR technologies. One of them is irradiation-induced swelling, which can lead to development of significant stresses in the matrix, followed by microcracking and subsequent release of fission products. Models of irradiation-induced swelling had been largely empirical and therefore they cannot be used to predict the microstructural dependence of microcracking. Existing models are also limited by the lack of understanding of defects that form due to irradiation in the range of temperatures relevant to fuel cladding in LWRs (<1000°C). Many of the defects in this regime of temperature are too small to be detected with traditional transmission electron microscopy (TEM) techniques. In fact the defects observed in traditional TEM account only for 10-45% of the swelling measured in irradiated SiC. Here, we developed a multi-scale simulation methodology combined with state of the art experimental imaging techniques based on aberration corrected scanning transmission electron microscopy (STEM) to provide a scientific basis for predictive models of radiation swelling and microcracking in SiC. Specifically, we have developed a phase field fracture model that predicts microcrack initiation and growth in polycrystalline SiC. The model accounts for single crystal anisotropy, including anisotropy in the elastic constants and anisotropic surface energy. It also considers the reduced fracture strength of grain boundaries. The model was implemented using the MARMOT mesoscale nuclear materials tool. We have parameterized the model for SiC using molecular dynamics simulation results. The model has been verified using single crystal, bicrystal, and polycrystal examples. Swelling model has also been developed based on cluster dynamics simulations of defect evolution in SiC. We found that point defects and small defect clusters have a significant contribution to swelling. This finding is important because point defects and very small defect clusters are not visible in experiments (e.g., in TEM). Combined modeling and experiments can bring critical insights into how swelling depends on irradiation conditions and the microstructure. In situ nanoindentation tests and ex situ nanoindentation tests were performed on assynthesized 3C-SiC and 3C-SiC irradiated under different radiation conditions. Without radiation, bend contour movement and residual bend contours after indentation demonstrate some room temperature plastic flow and residual plastic deformation. Plastic deformation recovery is also observed on unirradiated samples during unloading. Radiation-induced embrittlement is demonstrated by differences in crack geometry in in situ tests, and is consistent with ex situ test results. Failure by single, straight, cracks indicates decreased fracture toughness due to irradiation in 3C-SiC. Future work includes coupling of the swelling and fracture models and development of a master equation that can be used in the BISON code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive millimeter-wave imaging

Millimeter-wave hardware systems are being developed. Our approach begins with identifying and defining the applications. System requirements are then specified based on mission needs using our end-to-end performance model. The model was benchmarked against existing data bases and, where data is deficient, it is acquired via field measurements. The derived system requirements are then validated with the appropriate field measurements using our imaging testbeds and hardware breadboards. The result is a final system that satisfies all the requirements of the target mission.

Young, Stephen K.↗

Evaluation of Advanced Signal Processing Techniques to Improve Detection and Identification of Embedded Defects

By the end of 1996, 109 Nuclear Power Plants were operating in the United States, producing 22% of the Nation’s electricity [1]. At present, more than two thirds of these power plants are more than 40 years old. The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years [2]. The most important safety structures in an NPP are constructed of concrete. The structures generally do not allow for destructive evaluation and access is limited to one side of the concrete element. Therefore, there is a need for techniques and technologies that can assess the internal health of complex, reinforced concrete structures nondestructively. Previously, we documented the challenges associated with Non-Destructive Evaluation (NDE) of thick, reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures [3]. Consequently, a 7 feet tall, by 7 feet wide, by 3 feet and 4-inch-thick concrete specimen was constructed with 2.257-inch-and 1-inch-diameter rebar every 6 to 12 inches. In addition, defects were embedded the specimen to assess the performance of existing and future NDE techniques. The defects were designed to give a mix of realistic and controlled defects for assessment of the necessary measures needed to overcome the challenges with more heavily reinforced concrete structures. Information on the embedded defects is documented in [4]. We also documented the superiority of Frequency Banded Decomposition (FBD) Synthetic Aperture Focusing Technique (SAFT) over conventional SAFT when probing defects under deep concrete cover. Improvements include seeing an intensity corresponding to a defect that is either not visible at all in regular, full frequency content SAFT, or an improvement in contrast over conventional SAFT reconstructed images. This report documents our efforts in four fronts: 1) Comparative study between traditional SAFT and FBD SAFT for concrete specimen with and without Alkali-Silica Reaction (ASR) damage, 2) improvement of our Model-Based Iterative Reconstruction (MBIR) for thick reinforced concrete [5], 3) development of a universal framework for sharing, reconstruction, and visualization of ultrasound NDE datasets, and 4) application of machine learning techniques for automated detection of ASR inside concrete. Our comparative study between FBD and traditional SAFT reconstruction images shows a clear difference between images of ASR and non-ASR specimens. In particular, the left first harmonic shows an increased contrast and sensitivity to ASR damage. For MBIR, we show the superiority of model-based techniques over delay and sum techniques such as SAFT. Improvements include elimination of artifacts caused by direct arrival signals, and increased contrast and Signal to Noise Ratio. For the universal framework, we document a format for data storage based on the HDF5 file format, and also propose a modular Graphic User Interface (GUI) for easy customization of data conversion, reconstruction, and visualization routines. Finally, two techniques for ASR automated detection are presented. The first technique is based on an analysis of the frequency content using Hilbert Transform Indicator (HTI) and the second technique employees Artificial Neural Network (ANN) techniques for training and classification of ultrasound data as ASR or non-ASR damaged classes. The ANN technique shows great potential with classification accuracy above 95%. These approaches are extensible to the detection of additional reinforced, thick concrete defects and damage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-BRF-02: Automated Lung Segmentation Method Using Atlas-Based Sparse Shape Composition with a Shape Constrained Deformable Model

Purpose: To develop an automated lung segmentation method, which combines the atlas-based sparse shape composition with a shape constrained deformable model in thoracic CT for patients with compromised lung volumes. Methods: Ten thoracic computed tomography scans for patients with large lung tumors were collected and reference lung ROIs in each scan was manually segmented to assess the performance of the method. We propose an automated and robust framework for lung tissue segmentation by using single statistical atlas registration to initialize a robust deformable model in order to perform fine segmentation that includes compromised lung tissue. First, a statistical image atlas with sparse shape composition is constructed and employed to obtain an approximate estimation of lung volume. Next, a robust deformable model with shape prior is initialized from this estimation. Energy terms from ROI edge potential and interior ROI region based potential as well as the initial ROI are combined in this model for accurate and robust segmentation. Results: The proposed segmentation method is applied to segment right lung on three CT scans. The quantitative results of our segmentation method achieved mean dice score of (0.92–0.95), mean accuracy of (0.97,0.98), and mean relative error of (0.10,0.16) with 95% CI. The quantitative results of previously published RASM segmentation method achieved mean dice score of (0.74,0.96), mean accuracy of (0.66,0.98), and mean relative error of (0.04, 0.38) with 95% CI. The qualitative and quantitative comparisons show that our proposed method can achieve better segmentation accuracy with less variance compared with a robust active shape model method. Conclusion: The atlas-based segmentation approach achieved relatively high accuracy with less variance compared to RASM in the sample dataset and the proposed method will be useful in image analysis applications for lung nodule or lung cancer diagnosis and radiotherapy assessment in thoracic computed tomography.

60 APPLIED LIFE SCIENCES↗

A benchmark concept for simulation in radiographic testing

The new standard ISO 17636–2:2013 “NDT of welds: Radiographic testing - Part 2: X- and gamma ray techniques with digital detectors” describes a complex procedure for film replacement by phosphor imaging plates and digital detector arrays. RT modeling software should consider these detector types, X-ray film, and the standard requirements for image quality. Practitioners expect the same visibility of image quality indicators (IQI) in the simulated radiographs as in the experimental exposures. The proposed benchmark test is based on the comparison of experimental radiographs taken at BAM with modeled ones of participants. The experimental setup and the determination of the equivalent penetrameter sensitivity (EPS) as described in the procedure of ASTM E 746 are used for quantitative evaluation of the achievable contrast sensitivity for step hole IQIs as considered in Annex B of ISO 17636–2. System classification data for Computed Radiography (CR) and film systems will be provided by BAM according to ISO 11699–1 for selected film systems and according to ASTM E 2446 for selected CR systems. The classification of films and digital detectors is based on the measurement of the dose response function, the basic spatial resolution (SR{sub b}) of the image, and the measured image noise, which depends on the detector efficiency, the quantum statistics, and the detector fixed pattern noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Algorithms for detection of objects in image sequences captured from an airborne imaging system

This research was initiated as a part of the effort at the NASA Ames Research Center to design a computer vision based system that can enhance the safety of navigation by aiding the pilots in detecting various obstacles on the runway during critical section of the flight such as a landing maneuver. The primary goal is the development of algorithms for detection of moving objects from a sequence of images obtained from an on-board video camera. Image regions corresponding to the independently moving objects are segmented from the background by applying constraint filtering on the optical flow computed from the initial few frames of the sequence. These detected regions are tracked over subsequent frames using a model based tracking algorithm. Position and velocity of the moving objects in the world coordinate is estimated using an extended Kalman filter. The algorithms are tested using the NASA line image sequence with six static trucks and a simulated moving truck and experimental results are described. Various limitations of the currently implemented version of the above algorithm are identified and possible solutions to build a practical working system are investigated.

Kasturi, Rangachar↗