Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Multicomponent Convection Induced by Fronts in the Chlorate-Sulfite Reaction

An application of a new method is presented for the measurement of the temperature profiles of chemical waves propagating through a solution. Using solutions of thermocolor materials, the temperature distribution caused by the heat released in the propagating chlorate oxidation of sulfite was visualized and recorded using digital image processing methods. After calibration, the temperature gradient was calculated from the gray scale value in a digitized image. Extensive multicomponent convection ('fingering') was induced by descending fronts. Only ascending fingers were observed because of the large thermal gradient that suppressed descending ones. The characteristics of the temperature profile were determined as a function of initial sulfite and chlorate concentration, and tube diameter. Unusual behavior was observed when the fronts propagated under conditions of continuously changing diameter in a conical vessel. Fingering occurred periodically in a front descending in a flask with an increasing diameter. However, when a front propagated down in flask whose diameter decreased, no multicomponent convection was observed.

Nagy, Istvan P.↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

A block matching-based registration algorithm for localization of locally advanced lung tumors

Purpose: To implement and evaluate a block matching-based registration (BMR) algorithm for locally advanced lung tumor localization during image-guided radiotherapy. Methods: Small (1 cm{sup 3}), nonoverlapping image subvolumes (“blocks”) were automatically identified on the planning image to cover the tumor surface using a measure of the local intensity gradient. Blocks were independently and automatically registered to the on-treatment image using a rigid transform. To improve speed and robustness, registrations were performed iteratively from coarse to fine image resolution. At each resolution, all block displacements having a near-maximum similarity score were stored. From this list, a single displacement vector for each block was iteratively selected which maximized the consistency of displacement vectors across immediately neighboring blocks. These selected displacements were regularized using a median filter before proceeding to registrations at finer image resolutions. After evaluating all image resolutions, the global rigid transform of the on-treatment image was computed using a Procrustes analysis, providing the couch shift for patient setup correction. This algorithm was evaluated for 18 locally advanced lung cancer patients, each with 4–7 weekly on-treatment computed tomography scans having physician-delineated gross tumor volumes. Volume overlap (VO) and border displacement errors (BDE) were calculated relative to the nominal physician-identified targets to establish residual error after registration. Results: Implementation of multiresolution registration improved block matching accuracy by 39% compared to registration using only the full resolution images. By also considering multiple potential displacements per block, initial errors were reduced by 65%. Using the final implementation of the BMR algorithm, VO was significantly improved from 77% ± 21% (range: 0%–100%) in the initial bony alignment to 91% ± 8% (range: 56%–100%;p < 0.001). Left-right, anterior-posterior, and superior-inferior systematic BDE were 3.2, 2.4, and 4.4 mm, respectively, with random BDE of 2.4, 2.1, and 2.7 mm. Margins required to include both localization and delineation uncertainties ranged from 5.0 to 11.7 mm, an average of 40% less than required for bony alignment. Conclusions: BMR is a promising approach for automatic lung tumor localization. Further evaluation is warranted to assess the accuracy and robustness of BMR against other potential localization strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maskless Fourier transform holography

Fourier transform holography is a lensless imaging technique that retrieves an object's exit-wave function with high fidelity. It has been used to study nanoscale phenomena and spatio-temporal dynamics in solids, with sensitivity to the phase component of electronic and magnetic textures. However, the method requires an invasive and labor-intensive nanopatterning of a holography mask directly onto the sample, which can alter the sample properties, forces a fixed field-of-view, and leads to a low signal-to-noise ratio at high resolution. In this work, we propose using wavefront-shaping diffractive optics to create a structured probe with full control of its phase at the sample plane, circumventing the need for a mask. We demonstrate in silico that the method can image nanostructures and magnetic textures and validate our approach with a visible light-based experiment. The method enables investigation of a plethora of phenomena at the nanoscale including magnetic and electronic phase coexistence in solids, with further uses in soft and biological matter research.

Keskinbora, Kahraman↗

Evaluation of pebble scanning strategies for fuel qualification by simple simulated radiography

Reactor designs using tristructural-isotropic (TRISO) particles in pebble fuel forms have been developed in multiple programs and are now being designed and deployed by several companies around the world. Fuel pebbles for these designs commonly contain an inner fueled zone packed with TRISO particles and a fuel-free zone on the surface of the pebble to protect the particles within. Therefore, qualification of pebbles for use in a reactor commonly requires determination that there are no TRISO particles within a given minimum distance to the pebble surface. This determination may be made non-destructively by pebble radiography, in which a series of x-ray projections of the pebble are acquired. In this work, a method to create and image representative digital pebbles was developed to allow for rapid testing of various pebble radiography strategies to evaluate their effectiveness in detecting escapee particles. Using this method, imaging strategies in two and three dimensions were tested with fixed and adaptive angular distributions. Here it was found that an adaptive two-dimensional pebble scanning strategy was the most effective for fuel pebble qualification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging

Purpose: To substantiate the interdependency of contrast dose, radiation dose, and image quality in CT towards the patient- specific optimization of the imaging protocols Methods: The study deployed two phantom platforms. A variable sized (12, 18, 23, 30, 37 cm) phantom (Mercury-3.0) containing an iodinated insert (8.5 mgI/ml) was imaged on a representative CT scanner at multiple CTDI values (0.7–22.6 mGy). The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast-to-noise ratio (CNR), were calculated for 16 iodine-concentration levels (0–8.5 mgI/ml). The analysis was extended to a recently developed suit of 58 virtual human models (5D XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a simulation platform (CatSim, GE). 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The ratios of change in iodine-concentration versus dose (IDR) to yield a constant change in CNR were calculated for each patient size. Results: Mercury phantom results show the image-quality size- dependence on CTDI and IC levels. For desired image-quality values, the iso-contour-lines reflect the trade off between contrast-material and radiation doses. For a fixed iodine-concentration (4 mgI/mL), the IDR values for low (1.4 mGy) and high (11.5 mGy) dose levels were 1.02, 1.07, 1.19, 1.65, 1.54, and 3.14, 3.12, 3.52, 3.76, 4.06, respectively across five sizes. The simulation data from XCAT models confirmed the empirical results from Mercury phantom. Conclusion: The iodine-concentration, image quality, and radiation dose are interdependent. The understanding of the relationships between iodine-concentration, image quality, and radiation dose will allow for a more comprehensive optimization of CT imaging devices and techniques, providing the methodology to balance iodine-concentration and dose based on patient’s attributes.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 01: New technologies for astatine-211 targeted alpha therapy research

Purpose: The short-range, densely ionizing α-particles emitted by {sup 211}At (t{sub 1/2}=7.2h) are well suited for the treatment of diffuse microscopic disease, using cancer targeting biomolecules. {sup 211}At availability is limited by the rarity of α-cyclotrons required for standard production. Image-based dosimetry is also limited for {sup 211}At, which emits low intensity X-rays. Our goal was to leverage state-of-the-art infrastructure at TRIUMF to produce and evaluate two related isotopes, {sup 211}Rn (t{sub 1/2}=14.6h, 73% decay to {sup 211}At) as a generator for {sup 211}At, and {sup 209}At (t{sub 1/2}=5.4h, X-ray/gamma-ray emitter) as a novel 211At surrogate for preclinical imaging studies. Methods: Produced by spallation of uranium with 480 MeV protons, mass separated ion beams of short-lived francium isotopes were implanted into NaCl targets where {sup 211}Rn or {sup 209}At were produced by radioactive decay, in situ. {sup 211}Rn was transferred to dodecane from which {sup 211}At was efficiently extracted and evaluated for clinical applicability. High energy SPECT/CT was evaluated for measuring {sup 209}At activity distributions in mice and phantoms. Results: Our small scale {sup 211}Rn/{sup 211}At generator system provided high purity {sup 211}At samples. The methods are immediately scalable to the level of radioactivity required for in vivo experiments with {sup 211}At. {sup 209}At-based high energy SPECT imaging was determined suitable for pursuing image-based dosimetry in mouse tumour models. In the future, we will utilize quantitative {sup 209}At-SPECT for image-based dose calculations. Conclusion: These early studies provided a foundation for future endeavours with {sup 211}At-based α-therapy. Canada is now significantly closer to clinical targeted α-therapy of cancer.

60 APPLIED LIFE SCIENCES↗

Hubble Space Telescope Imaging of the Circumnuclear Environments of the CfA Seyfert Galaxies: Nuclear Spirals and Fueling

We present archival Hubble Space Telescope (HST) images of the nuclear regions of 43 of the 46 Seyfert galaxies found in the volume limited,spectroscopically complete CfA Redshift Survey sample. Using an improved method of image contrast enhancement, we created detailed high-quality " structure maps " that allow us to study the distributions of dust, star clusters, and emission-line gas in the circumnuclear regions (100-1000 pc scales) and in the associated host galaxy. Essentially all of these Seyfert galaxies have circumnuclear dust structures with morphologies ranging from grand-design two-armed spirals to chaotic dusty disks. In most Seyfert galaxies there is a clear physical connection between the nuclear dust spirals on hundreds of parsec scales and large-scale bars and spiral arms in the host galaxies proper. These connections are particularly striking in the interacting and barred galaxies. Such structures are predicted by numerical simulations of gas flows in barred and interacting galaxies and may be related to the fueling of active galactic nuclei by matter inflow from the host galaxy disks. We see no significant differences in the circumnuclear dust morphologies of Seyfert 1s and 2s, and very few Seyfert 2 nuclei are obscured by large-scale dust structures in the host galaxies. If Sevfert 2s are obscured Sevfert Is, then the obscuration must occur on smaller scales than those probed by HST.

Pogge, Richard W.↗

A Grobner Basis Solution for Lightning Ground Flash Fraction Retrieval

A Bayesian inversion method was previously introduced for retrieving the fraction of ground flashes in a set of flashes observed from a (low earth orbiting or geostationary) satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters, a scalar function was minimized by a numerical method. In order to improve this optimization, we introduce a Grobner basis solution to obtain analytic representations of the model parameters that serve as a refined initialization scheme to the numerical optimization. Using the Grobner basis, we show that there are exactly 2 solutions involving the first 3 moments of the (exponentially distributed) data. When the mean of the ground flash optical characteristic (e.g., such as the Maximum Group Area, MGA) is larger than that for cloud flashes, then a unique solution can be obtained.

Solakiewicz, Richard↗

SkyFACT: high-dimensional modeling of gamma-ray emission with adaptive templates and penalized likelihoods

We present SkyFACT (Sky Factorization with Adaptive Constrained Templates), a new approach for studying, modeling and decomposing diffuse gamma-ray emission. Like most previous analyses, the approach relies on predictions from cosmic-ray propagation codes like GALPROP and DRAGON. However, in contrast to previous approaches, we account for the fact that models are not perfect and allow for a very large number (∼> 10{sup 5}) of nuisance parameters to parameterize these imperfections. We combine methods of image reconstruction and adaptive spatio-spectral template regression in one coherent hybrid approach. To this end, we use penalized Poisson likelihood regression, with regularization functions that are motivated by the maximum entropy method. We introduce methods to efficiently handle the high dimensionality of the convex optimization problem as well as the associated semi-sparse covariance matrix, using the L-BFGS-B algorithm and Cholesky factorization. We test the method both on synthetic data as well as on gamma-ray emission from the inner Galaxy, |ℓ|<90{sup o} and | b |<20{sup o}, as observed by the Fermi Large Area Telescope. We finally define a simple reference model that removes most of the residual emission from the inner Galaxy, based on conventional diffuse emission components as well as components for the Fermi bubbles, the Fermi Galactic center excess, and extended sources along the Galactic disk. Variants of this reference model can serve as basis for future studies of diffuse emission in and outside the Galactic disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the maximum cross-correlation method of estimating sea surface velocities from sequential satellite images

The maximum cross correlation (MCC) method of Leese et al. (1971) for estimating sea surface velocities from sequences of satellite images is evaluated by comparing the MCC fields obtained from sequences of AVHRR and CZCS with in situ data and velocity fields calculated with a high-resolution quasi-geostrophic model. The rms differences and vector correlations between the velocity field produced by the MCC method and the model's field are presented. It is shown that much of the difference between the MCC fields and either the in situ data or the model velocity fields can be accounted for by considering physical and biological processes not included in the MCC method. The conditions under which the method is likely to be most successful are discussed.

Tokmakian, Robin↗

SU-D-12A-01: An Inter-Projection Interpolation (IPI) Approach for the Synchronized Moving Grid (SMOG) to Reduce Dose in Cone Beam CT

Purpose: Synchronized moving grid is a promising technique to reduce scatter and ghost artifacts in cone beam computed tomography (CBCT). However, it requires 2 projections in the same gantry angle to obtain full information due to signal blockage by the grid. We proposed an inter-projection interpolation (IPI) method to estimate blocked signals, which may reduce the scan time and the dose. This study aims to provide a framework to achieve a balance between speed, dose and image quality. Methods: The IPI method is based on the hypothesis that an abrupt signal in a projection can be well predicted by the information in the two immediate neighboring projections if the gantry angle step is small. The study was performed on a Catphan and a head phantom. The SMOG was simulated by erasing the information (filling with “0”) of the areas in each projection corresponding to the grid. An IPI algorithm was applied on each projection to recover the erased information. FDK algorithm was used to reconstruct CBCT images for the IPI-processed projections, and compared with the original image in term of signal to noise ratio (SNR) measured in the whole reconstruction image range. The effect of gantry angle step was investigated by comparing the CBCT images from projection sets of various gantry intervals, with IPI-predicted projections to fill the missing projection in the interval. Results: The IPI procession time was 1.79s±0.53s for each projection. SNR after IPI was 29.0db and 28.1db for the Catphan and head phantom, respectively, comparing to 15.3db and 22.7db for an inpainting based interpolation technique. SNR was 28.3, 28.3, 21.8, 19.3 and 17.3 db for gantry angle intervals of 1, 1.5, 2, 2.5 and 3 degrees, respectively. Conclusion: IPI is feasible to estimate the missing information, and achieve an reasonable CBCT image quality with reduced dose and scan time. This study is supported by NIH/NCI grant 1R01CA166948-01.

60 APPLIED LIFE SCIENCES↗

Cathodoluminescence-activated nanoscale imaging

Provided herein are non-invasive methods of nanoscale imaging of a sample using an illumination layer and an electron beam. For example, the electron may activate the illumination layer without activating the sample, and the illumination layer may emit cathodoluminescence to produce a nanoscale image of the sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Defect Detection of Industrial Radiography Images of Ammonia Pipes by a Sparse Coding Model

Pipeline transportation systems for liquid anhydrous ammonia require periodic inspections for pipe defects. Defects such as crack-like flaws, including those due to stress corrosion and fatigue crack growth and fatigue of welded joints, can be tested by in situ radiography testing (RT). It is required that the detection technique should reveal the defect region without any significant distortion. Imaging noise such as that due to radiation scattering reduces contrast over the whole or part of the image, causing a reduction in image quality. Various image processing methods can be utilized to improve the outcome of RT of pipes. The sparse coding model is a powerful contrast improvement algorithm, but it tends to eliminate imaging details, passing them off as noise. We present a novel implementation of the sparse coding model based on a probabilistic interpretation to improve defect detection in ammonia pipelines radiography images. The performance of this procedure was evaluated in radiographic images of defect and corrosion regions for different pipe types. For ammonia pipes, the technique was found to offer a significant improvement in defect detection while preserving imaging details.

42 ENGINEERING↗

Stress-induced alteration of left ventricular eccentricity: An additional marker of multivessel CAD

Background: Abnormal left ventricular (LV) eccentricity index (EI) is a marker of adverse cardiac remodeling. However, the interaction between stress-induced alterations of EI and major cardiac parameters has not been explored. We sought to evaluate the relationship between LV EI and coronary artery disease (CAD) burden in patients submitted to myocardial perfusion imaging (MPI). Methods and results: Three-hundred and forty-three patients underwent MPI and coronary angiography. LV ejection fraction (EF) and EI were computed from gated stress images as measures of stress-induced functional impairment. One-hundred and thirty-six (40%), 122 (35%), and 85 (25%) patients had normal coronary arteries, single-vessel CAD, and multivessel CAD, respectively. Post-stress EI was lower in patients with multivessel CAD than in those with normal coronary arteries and single-vessel CAD (P = 0.001). This relationship was confirmed only in patients undergoing exercise stress test, where a lower post-stress EI predicted the presence of multivessel CAD (P = 0.039). Conclusions: Post-stress alterations of LV EI on MPI may unmask the presence of multivessel CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Restoration of multichannel microwave radiometric images

A constrained iterative image restoration method is applied to multichannel diffraction-limited imagery. This method is based on the Gerchberg-Papoulis algorithm utilizing incomplete information and partial constraints. The procedure is described using the orthogonal projection operators which project onto two prescribed subspaces iteratively. Its properties and limitations are presented. The effect of noise was investigated and a better understanding of the performance of the algorithm with noisy data has been achieved. The restoration scheme with the selection of appropriate constraints was applied to a practical problem. The 6.6, 10.7, 18, and 21 GHz satellite images obtained by the scanning multichannel microwave radiometer (SMMR), each having different spatial resolution, were restored to a common, high resolution (that of the 37 GHz channels) to demonstrate the effectiveness of the method. Both simulated data and real data were used in this study. The restored multichannel images may be utilized to retrieve rainfall distributions.

Chin, R. T.↗

Invariant discovery of features across multiple length scales: Applications in microscopy and autonomous materials characterization

Physical imaging is a foundational characterization method in areas from condensed matter physics and chemistry to astronomy and spans length scales from atomic to universe. Images encapsulate crucial data regarding atomic bonding, materials microstructures, and dynamic phenomena such as microstructural evolution and turbulence, among other phenomena. The challenge lies in effectively extracting and interpreting this information. Variational Autoencoders (VAEs) have emerged as powerful tools for identifying the underlying factors of variation in image data, providing a systematic approach to distilling meaningful patterns from complex data sets. However, a significant hurdle in their application is the definition and selection of appropriate descriptors reflecting local structures. Here, we introduce the scale-invariant VAE approach (SI-VAE) based on the progressive training of the VAE with the descriptors sampled at different length scales. The SI-VAE allows the discovery of the length scale-dependent factors of variation in the system. Here, we illustrate this approach using the ferroelectric domain images and generalize it to the movies of the electron-beam induced phenomena in graphene and topography evolution across combinatorial libraries. This approach can further be used to initialize the decision making in automated experiments including structure–property discovery and can be applied across a broad range of imaging methods. This approach is universal and can be applied to any spatially resolved data including both experimental imaging studies and simulations, and can be particularly useful for exploration of phenomena such as turbulence and scale-invariant transformation fronts.

36 MATERIALS SCIENCE↗

Energy dissipation via acoustic emission in ductile crack initiation

In this article, we present a modeling approach to estimate the energy release due to ductile crack initiation in conjunction to the energy dissipation associated with the formation and propagation of transient stress waves typically referred to as acoustic emission. To achieve this goal, a ductile fracture problem is investigated computationally using the finite element method based on a compact tension geometry under Mode I loading conditions. To quantify the energy dissipation associated with acoustic emission, a crack increment is produced given a pre-determined notch size in a 3D cohesive-based extended finite element model. The computational modeling methodology consists of defining a damage initiation state from static simulations and linking such state to a dynamic formulation used to evaluate wave propagation and related energy redistribution effects. The model relies on a custom traction separation law constructed using full field deformation measurements obtained experimentally using the digital image correlation method. The amount of energy release due to the investigated first crack increment is evaluated through three different approaches both for verification purposes and to produce an estimate of the portion of the energy that radiates away from the crack source in the form of transient waves. The results presented herein propose an upper bound for the energy dissipation associated to acoustic emission, which could assist the interpretation and implementation of relevant nondestructive evaluation methods and the further enrichment of the understanding of effects associated with fracture.

42 ENGINEERING↗