Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Cost-Effective Three-Phase Current Amplifier Interface for Real-time Simulator with Relays in-the-Loop

This paper presents a prototype of a simple and cost-effective design using a high-power monolithic power amplifier that allows the relay in-the-loop connectivity for protection and control applications using a real-time simulator. This low-cost amplifier interface increases the number of protective relays in-the-loop connected with the real-time simulator, expanding the scalability of protection devices that could be tested. The amplifier control design was developed in abc coordinates and utilizes integral and proportional-resonant controllers to provide a good tracking of both the fundamental component as the dc component that might be present during fault conditions. To validate the prototype, the current signals and tripping time of a relay interfaced with the current amplifier were compared against a reference relay connected to the low-voltage interface. Both protective relays were set with a U3 Very Inverse time overcurrent curve. The experimental results exhibited similar behaviors for the breaker currents, validating the amplifier interface prototype.

Ferrari Maglia, Max↗

Transmission and Distribution Co-Simulation with Possible Distribution Loops

A co-simulation algorithm for three-phase modeled distribution systems and sequence modeled transmission is de- veloped. Novel in the approach is the combination of looped distribution capability, i.e. closing current paths between trans- mission system nodes in the distribution system, with the option to model transmission in three sequence detail instead of just positive sequence. This is achieved by placing equivalent branches in the transmission model and accounting for the loop currents. Additionally, we provide validation for co-simulation results against a full, combined three-phase model. This comparison allows us to better analyze the strengths and weaknesses of different modeling choices.

Schweitzer, Eran↗

Hardware-in-the-Loop Testing of Wide-Area Damping Controller for Field Implementation in Large-scale Power Grid

In our previous work, an adaptive measurement-driven wide-area damping controller (WADC) for suppressing inter-area oscillations has been proposed and a hardware prototype was developed and validated through hardware-in-the-loop tests. As a continuation of the work, this paper introduces a WADC software prototype to handle the realistic challenges for field implementation in the control room of the power grid. The WADC software is developed and operated as an openPDC adapter with a graphical user interface (GUI) to monitor the WADC inputs and output, the communication delays and other variables. The software prototype has been fully tested through an enhanced hardware-in-the-loop (HIL) test setup. Its performance is verified under various realistic communication uncertainties, such as random time delays and data losses, with different communication protocols. The experiment results have proven the WADC software can deliver sufficient damping to suppress the targeted oscillation mode in handling various communication uncertainties for future field deployment.

Jia, Xinlan↗

Hardware-in-the-Loop Co-simulation of Distribution Grid for Demand Response

In modern power systems, co-simulation is proposed as an enabler for analyzing the interactions between disparate systems. This paper introduces the co-simulation platform Virtual Grid Integration Laboratory (VirGIL) including Hardware-in-the-Loop testing, and demonstrates its potential to assess demand response strategies. VirGIL is based on a modular architecture using the Functional Mock-up Interface industrial standard to integrate new simulators. VirGIL combines state-of-the-art simulators in power systems, communications, buildings, and control. In this work, VirGIL is extended with a Hardware-in-the-Loop component to control the ventilation system of a real 12-story building in Denmark. VirGIL capabilities are illustrated in three scenarios: load following, primary reserves and load following aggregation. Experimental results show that the system can track one minute changing signals and it can provide primary reserves for up-regulation. Furthermore, the potential of aggregating several ventilation systems is evaluated considering the impact at distribution grid level and the communications protocol effect.

Rotger-Griful, Sergi↗

A Dynamically Reconfigurable System for Closed-Loop Measurements of Network Traffic

Streaming network traffic measurement and analysis is critical for detecting and preventing any real-time anomalies in the network. The high speeds and complexity of today's networks, coupled with ever evolving threats, necessitate closing of the loop between measurements and their analysis in real time. The ensuing system demands high levels of programmability and processing where streaming measurements adapt to the changing network behavior in a goal-oriented manner. In this work, we exploit the features and requirements of the problem and develop an application-specific FPGA-based closed-loop measurement (CLM) system. We make novel use of fine-grained partial dynamic reconfiguration (PDR) as underlying reprogramming paradigm, performing low-latency just-in-time compiled logic changes in FPGA fabric corresponding to the dynamic measurement requirements. Our innovative dynamically reconfigurable socket offers 3× logic savings over conventional static solutions, while offering much reduced reconfiguration latencies over conventional PDR mechanisms. Here, we integrate multiple sockets in a highly parallel CLM framework and demonstrate its effectiveness in identifying heavy flows in streaming network traffic. The results using an FPGA prototype offer 100 percent detection accuracy while sustaining increasing link speeds.

97 MATHEMATICS AND COMPUTING↗

Active Field Cancellation to Prevent Saturation in Ferromagnetic-Core Loop Antennas

Ferromagnetic-core loop antennas with high-permeability core materials are typically used in size-constrained applications requiring the detection and reception of weak very low frequency and extremely low frequency signals. However, high-permeability materials are susceptible to saturation in the presence of strong magnetic fields such as those generated by power lines, in research laboratories, or through natural phenomena. Here, a system is presented that actively controls the magnetic flux in the core of the antenna by applying a control signal to an independent set of windings on the same core. This control signal is phase locked to the offending signal and the two signals destructively combine in the core. Our results show that it is possible to actively cancel the fundamental component of a strong interferer in the core of a high sensitivity ferromagnetic-core loop antenna and prevent core saturation. This approach eliminates signal distortion caused by magnetic saturation that passive signal cancellation or signal processing in the receiver do not. Furthermore, high-sensitivity ferromagnetic-core antennas can be used in applications where they were previously thought unsuitable.

42 ENGINEERING↗

A General Framework for Human-in-the-Loop Cognitive Digital Twins

Modelling and analysis of systems that are equipped with sensors and connected to the Internet are becoming more automated and less human-dependent. However, bringing expert knowledge into the loop along with data obtained from Internet of Thing (IoT) devices minimizes the risk of making poor and unexplainable decisions and helps to assess the impact of different strategies before applying them in reality. While Digital Twins are more of a data-driven simulation of the physical system, Cognitive Digital Twins bring the human dimension into the modelling and simulation. In this paper, we aim to emphasize the crucial role of explainability and the underlying rationale behind automated or interactive decision-making processes. Furthermore, we propose an initial framework that delineates the specific points within the feedback loop of a cognitive digital twin where human involvement can be incorporated.

Niloofar, Parisa↗

Ni( II )-binding affinity of Cc NikZ-II and its homologs: the role of the HH -prong and variable loop revealed by structural and mutational studies

Extracytoplasmic Ni(II)-binding proteins (NiBPs) are molecular shuttles involved in cellular nickel uptake. Here, we determined the crystal structure of apo CcNikZ-II at 2.38 Å, which revealed a Ni(II)-binding site comprised of the double His (HH-)prong (His511, His512) and a short variable (v-)loop nearby (Thr59-Thr64, TEDKYT). Mutagenesis of the site identified Glu60 and His511 as critical for high affinity Ni(II)-binding. Phylogenetic analysis showed 15 protein clusters with two groups containing the HH-prong. Metal-binding assays with 11 purified NiBPs containing this feature yielded higher Ni(II)-binding affinities. Replacement of the wild type v-loop with those from other NiBPs improved the affinity by up to an order of magnitude. This work provides molecular insights into the determinants for Ni(II) affinity and paves way for NiBP engineering.

59 BASIC BIOLOGICAL SCIENCES↗

Transient Cold Flow Simulation of Fast Fluidized Bed Fuel Reactors for Chemical-Looping Combustion

Circulating fluidized bed in chemical-looping combustion (CLC) is a recent technology that provides great advantage for gas–solid interaction and efficiency. In order to obtain a thorough understanding of this technology and to assess its effectiveness for industrial scale deployment, numerical simulations are conducted. Computational fluid dynamics (CFD) simulations are performed with dense discrete phase model (DDPM) to simulate the gas–solid interactions. CFD commercial software ansysfluent is used for the simulations. Two bed materials of different particle density and diameter, namely the molochite and Fe100, are used in studying the hydrodynamics and particle behavior in a fuel reactor corresponding to the experimental setup of Haider et al. (2016, “A Hydrodynamic Study of a Fast-Bed Dual Circulating Fluidized Bed for Chemical Looping Combustion,” Energy Technol., 4(10), pp. 1254–1262.) at Cranfield University in the UK. Both the simulations show satisfactory agreement with the experimental data for both the static pressure and volume fraction at various heights above the gas inlet in the reactor. It is found that an appropriate drag law should be used in the simulation depending on the particle size and flow conditions in order to obtain accurate results. Furthermore, the simulations demonstrate the ability of CFD/DDPM to accurately capture the physics of circulating fluidized bed-based CLC process at pilot scale which can be extended to industrial scale projects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Artificial-Intelligence and Machine-Learning-Based Methodology to Conduct Seemingly Strain-Controlled Fatigue Test in a Pressurized-Water-Reactor-Test-Loop-Autoclave, While Not Controlling the Strain

In general, low cycle fatigue analysis of pressurized water reactor (PWR) components, requires strain-controlled fatigue test data such as using strain versus life (ε–N) curves. Conducting strain-controlled fatigue tests under in-air conditions is not an issue. However, controlling strain in a PWR-test-loop-autoclave is a challenge, since an extensometer cannot be placed in a narrow autoclave (typically used in a high-temperature-pressure PWR-test-loop). This is due to lack of space inside an autoclave that houses the test specimen. In addition, installing a contact-type extensometer in the path of a high-pressure flow can be a challenge. These difficulties of using an extensometer inside an autoclave led us to use an outside-autoclave displacement sensor which measures the displacement of pull-rod-specimen assembly. However, in our study (based on in-air fatigue test data), we found that a pull-rod-controlled based fatigue test can lead to substantial cyclic hardening/softening resulting in substantially different cyclic strain amplitudes and their rates compared to the desired cyclic strain amplitudes and its rates. In this paper, we propose an Artificial-Intelligence and Machine-Learning based technique such as using k-means clustering technique to improve the pull-rod-control based fatigue test method, such that the gage-area strain amplitude and rates can reasonably be achieved. In support of this, we present the fatigue test results for both 316 SS base and 81/182 dissimilar-metal-weld specimens.

42 ENGINEERING↗

A Compact Gas Liquid Separator for the Spallation Neutron Source Mercury Process Loop

Upgrades at the spallation neutron source (SNS) accelerator at Oak Ridge National Laboratory are underway to double its proton beam power from 1.4 to 2.8 MW. About 2 MW will go to the current first station while the rest will go to the future Second Target Station. The increase of beam power to the first target station is especially challenging for its mercury target. When the short proton beam hits the target, strong pressure waves are generated, causing cavitation erosion and challenging stresses for the target's weld regions. SNS has successfully operated reliably at 1.4 MW by mitigating the pressure wave with the injection of small Helium bubbles into the mercury. To operate reliably at 2 MW, more gas will be injected into mercury to mitigate the pressure wave further. However, the mercury process loop was not originally designed for gas injection, and the accumulation of gas in the pipes is a concern. Due to space constraints, a custom gas liquid separator (GLS) was designed to fit a 90-deg horizontal elbow space in the SNS mercury loop. Simulations and experiments were performed, and a successful design was developed that has the desired efficiency while keeping the pressure losses acceptable.

42 ENGINEERING↗

Open-Loop Control Co-Design of Semisubmersible Floating Offshore Wind Turbines Using Linear Parameter-Varying Models

Here, this paper discusses a framework to design elements of the plant and control systems for floating offshore wind turbines in an integrated manner using linear parameter-varying models. Multiple linearized models derived from aero-elastic simulation software in different operating regions characterized by the incoming wind speed are combined to construct an approximate low-fidelity model of the system. The combined model is then used to generate open-loop, optimal control trajectories as part of a nested control co-design strategy that explores the system’s power production and stability using the platform pitch tilt as a proxy in the context of crucial plant and control design decisions. The radial distance between the central and outer columns and the diameter of the outer columns of the semisubmersible platform are the plant design variables. The platform stability and power production are studied for different plant design decisions. The effect of plant decisions on subsequent power production and stability response of the floating wind turbine is quantified in terms of the levelized cost of energy. The results show that the inner-loop constraints and the plant design decisions affect the turbine’s power and, subsequently, the cost of the system.

17 WIND ENERGY↗

Assessment of Prototypic and Closed Loop Operation during Pulse Jet Mixer Tests with Non-Cohesive Solids to Develop Scale-up Relationships

Scaled tests were conducted to develop correlations describing pulse jet mixer (PJM) performance with non-cohesive solids in water. These correlations were developed in scaled test systems that incorporated certain simplified aspects including non-prototypic refill associated with closed-loop operation of the mixing jets. When this test data was compared with experiments that used prototypic PJM refill, a difference in the critical suspension velocity (UCS) was identified. The non-prototypic aspects of the initial testing were reviewed and assessed. The effects of non-prototypic refill associated with the closed loop operation of the jets, previously known to affect solids cloud height, can be described in terms of a modified settling velocity. When the modified settling velocity is incorporated into the physical model, the adjusted new physical model does a better job of predicting UCS results for prototypic PJM refill tests. The adjusted new physical model was bench-marked with data taken during three prototypic drive tests with a mono-disperse simulant, a 3-part medium distribution stimulant and a 5-part broad distribution simulant The applicability of the non-prototypic scale-up behavior to prototypic testing was analyzed. The effects of non-prototypic refill caused measured values of UCS to be somewhat reduced at larger scales. Hence the scale-up exponents for the non-prototypic drive tests are believed to be smaller than they would have been had there been prototypic refill. Estimated scale-up exponents for the prototypic testing were developed for 8 and 12 pulse tube configurations.

comparison between prototypic and simplified drive↗

SU-F-T-201: Acceleration of Dose Optimization Process Using Dual-Loop Optimization Technique for Spot Scanning Proton Therapy

Purpose: The purpose was to demonstrate a developed acceleration technique of dose optimization and to investigate its applicability to the optimization process in a treatment planning system (TPS) for proton therapy. Methods: In the developed technique, the dose matrix is divided into two parts, main and halo, based on beam sizes. The boundary of the two parts is varied depending on the beam energy and water equivalent depth by utilizing the beam size as a singular threshold parameter. The optimization is executed with two levels of iterations. In the inner loop, doses from the main part are updated, whereas doses from the halo part remain constant. In the outer loop, the doses from the halo part are recalculated. We implemented this technique to the optimization process in the TPS and investigated the dependence on the target volume of the speedup effect and applicability to the worst-case optimization (WCO) in benchmarks. Results: We created irradiation plans for various cubic targets and measured the optimization time varying the target volume. The speedup effect was improved as the target volume increased, and the calculation speed increased by a factor of six for a 1000 cm3 target. An IMPT plan for the RTOG benchmark phantom was created in consideration of ±3.5% range uncertainties using the WCO. Beams were irradiated at 0, 45, and 315 degrees. The target’s prescribed dose and OAR’s Dmax were set to 3 Gy and 1.5 Gy, respectively. Using the developed technique, the calculation speed increased by a factor of 1.5. Meanwhile, no significant difference in the calculated DVHs was found before and after incorporating the technique into the WCO. Conclusion: The developed technique could be adapted to the TPS’s optimization. The technique was effective particularly for large target cases.

60 APPLIED LIFE SCIENCES↗

Estimating two-loop radiative effects in the MOLLER experiment

Within the on-shell renormalization scheme, two-loop electroweak corrections to the parityviolating polarization asymmetry in the reaction e{sup -}e{sup -} {yields} e{sup -}e{sup -}({gamma}, {gamma}{gamma}) were estimated for the MOLLER experiment at JLab. The infrared divergence and the imaginary part of the amplitude were taken completely under control. Relevant compact expressions obtained by using asymptotic methods are free from unphysical parameters and are convenient for analysis and for numerical estimations. A numerical analysis revealed a significant scale of two-loop effects and the need for taking them into account in the MOLLER experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Convergence and gauge dependence properties of the resummed one-loop quark-quark scattering amplitude in perturbative QCD

The one-loop QCD effective charge α{sup eff}{sub s }for quark-quark scattering is derived by diagrammatic resummation of the one-loop amplitude using an arbitrary covariant gauge. Except for the particular choice of gauge parameter ξ = −3, α{sup eff}{sub s }is found to increase with increasing physical scale, Q, as lnQ or ln{sup 2} Q. For ξ = −3, α{sup eff}{sub s }decreases with increasing Q and satisfies a renormalization group equation. Also, except for the case ξ = 19/9, convergence radii of geometric series are found to impose upper limits on Q.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polyakov loop fluctuations and deconfinement in the limit of heavy quarks

We explore the influence of heavy quarks on color deconfinement within an effective model of gluons interacting with dynamical quarks. As the quark mass decreases, the strength of the explicit breaking of the Z(3) symmetry grows, and the first-order transition in the pure SU(3) gauge theory ends in a critical end point. The nature of this critical end point is examined by studying the fluctuations of the Polyakov loop, quantified by the corresponding susceptibilities. The properties of the Polyakov loop fluctuations and their ratios are also studied in QCD with physical quark masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compactified rotating branes in the matrix model, and excitation spectrum towards one loop

Here, we study compactified brane solutions of type $\mathbb{R}^{4} \times K$ in the IIB matrix model, and obtain explicitly the bosonic and fermionic fluctuation spectrum required to compute the one-loop effective action. We verify that the one-loop contributions are UV finite for $\mathbb{R}^{4} \times T^{2}$, and supersymmetric for $\mathbb{R}^{3} \times S^{1}$. The higher Kaluza–Klein modes are shown to have a gap in the presence of flux on T 2 , and potential problems concerning stability are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗