Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Investigation of the Effect of Temperature on the Structure of SARS-CoV-2 Spike Protein by Molecular Dynamics Simulations

Statistical and epidemiological data imply temperature sensitivity of the SARS-CoV2 coronavirus. However, the molecular level understanding of the virus structure at different temperature is still not clear. Spike protein is the outermost structural protein of the SARS-CoV-2 virus which interacts with the Angiotensin Converting Enzyme 2 (ACE2), a human receptor, and enters the respiratory system. In this study, we performed an all atom molecular dynamics simulation to study the effect of temperature on the structure of the Spike protein. After 200 ns of simulation at different temperatures, we came across some interesting phenomena exhibited by the protein. We found that the solvent exposed domain of Spike protein, namely S1, is more mobile than the transmembrane domain, S2. Structural studies implied the presence of several charged residues on the surface of N-terminal Domain of S1 which are optimally oriented at 10– 30°C. Bioinformatics analyses indicated that it is capable of binding to other human receptors and should not be disregarded. Additionally, we found that receptor binding motif (RBM), present on the receptor binding domain (RBD) of S1, begins to close around temperature of 40°C and attains a completely closed conformation at 50°C. We also found that the presence of glycan moieties did not influence the observed protein dynamics. Nevertheless, the closed conformation disables its ability to bind to ACE2, due to the burying of its receptor binding residues. Our results clearly show that there are active and inactive states of the protein at different temperatures. This would not only prove beneficial for understanding the fundamental nature of the virus, but would be also useful in the development of vaccines and therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity to Thermonuclear Reaction Rates in Modeling the Abundance Anomalies of NGC 2419

Abundance anomalies in globular clusters provide strong evidence for multiple stellar populations within each cluster. These populations are usually interpreted as distinct generations, with the currently observed second-generation stars having formed in part from the ejecta of massive, first-generation “polluter” stars, giving rise to the anomalous abundance patterns. The precise nature of the polluters and their enrichment mechanism are still unclear. Even so, the chemical abundances measured in second-generation stars within the globular cluster NGC 2419 provide insight into this puzzling process. Previous work used Monte Carlo nuclear reaction network calculations to constrain the temperature–density conditions that could reproduce the observed abundances, thereby placing robust limits on the origins of the polluter material. The effect of individual reaction rates on these conditions has not been studied, however. Thus, we perform an exhaustive sensitivity study on the nuclear physics input to determine which reactions have the greatest impact on these predictions. We find that the {sup 30}Si(p,γ){sup 31}P, {sup 37}Ar(p,γ){sup 38}K, {sup 38}Ar(p,γ){sup 39}K, and {sup 39}K(p,γ){sup 40}Ca reactions are all critical in determining the temperature–density conditions, and ultimately, the origins of the polluter material. We conclude with recommendations for future experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Building America Case Study: Advanced Controls Improve Performance of Combination Space and Water Heating Systems, Minneapolis, Minnesota

The combined space and water heating systems (combi) uses a high efficiency direct vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that utilizing condensing water heaters or boilers with hydronic air handlers can provide both space and water heating with efficiencies of 90% or greater. Improved controls have the potential to reduce some of this complexity and boost the measured performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York

Condensing boiler technology has been around for many years and has proven to be a durable, reliable method of heating. Based on previous research efforts, however, it is apparent that these types of systems are not designed and installed to achieve maximum efficiency. For example, in order to protect their equipment in the field, manufacturers of low-mass condensing boilers typically recommend design strategies and components that ensure steady, high flow rates through the heat exchangers, such as primary-secondary piping, which ultimately result in decreased efficiency. There is also a significant lack of information for contractors on how to configure these systems to optimize overall efficiency. In response to these findings, researchers from Building America team Consortium for Advanced Residential Buildings worked with industry partners to develop hydronic system designs that would address these issues and result in higher overall system efficiencies and improved response times.

AFUE↗

Library API for Z-Order Memory Layout

This library provides a simple-to-use API for implementing an altnerative to traditional row-major order in-memory layout, one based on a Morton- order space filling curve (SFC) , specifically, a Z-order variant of the Morton order curve. The library enables programmers to, after a simple initialization step, to convert a multidimensional array from row-major to Z- order layouts, then use a single, generic API call to access data from any arbitrary (i,j,k) location from within the array, whether it it be stored in row- major or z-order format. The motivation for using a SFC in-memory layout is for improved spatial locality, which results in increased use of local high speed cache memory. The basic idea is that with row-major order layouts, a data access to some location that is nearby in index space is likely far away in physical memory, resulting in poor spatial locality and slow runtime. On the other hand, with a SFC-based layout, accesses that are nearby in index space are much more likely to also be nearby in physical memory, resulting in much better spatial locality, and better runtime performance. Numerous studies over the years have shown significant runtime performance gains are realized by using a SFC-based memory layout compared to a row-major layout, sometimes by as much as 50%, which result from the better use of the memory and cache hierarchy that are attendant with a SFC-based layout (see, for example, [Beth2012]). This library implementation is intended for use with codes that work with structured, array-based data in 2 or 3 dimensions. It is not appropriate for use with unstructured or point-based data.

Bethel, E. Wes↗

A Parameter Study for Improving the Performance of the Production Target for the Muon G-2 Experiment

The target station of the Muon g-2 Experiment is one of the central pieces for the production of secondary pions which eventually will decay to the desired muons. In this paper, we report adjustments made to optimize its perfor-mance. For instance, in the simulation we vary the size of the primary incoming beam and examine its impact on the downstream production. We then compare this with the ac-tual measured beam size upstream of the target. In addition, we examine the sensitivity in performance with the strength of the lithium lens and the distance between lens and target. We compare measured data with simulation results.

43 PARTICLE ACCELERATORS↗

A Visual Analytics Framework for Reviewing Streaming Performance Data

Understanding and tuning the performance of extreme-scale parallel computing systems demands a streaming approach due to the computational cost of applying offline algorithms to vast amounts of performance log data. Analyzing large streaming data is challenging because the rate of receiving data and limited time to comprehend data make it difficult for the analysts to sufficiently examine the data without missing important changes or patterns. To support streaming data analysis, we introduce a visual analytic framework comprising of three modules: data management, analysis, and interactive visualization. The data management module collects various computing and communication performance metrics from the monitored system using streaming data processing techniques and feeds the data to the other two modules. The analysis module automatically identifies important changes and patterns at the required latency. In particular, we introduce a set of online and progressive analysis methods for not only controlling the computational costs but also helping analysts better follow the critical aspects of the analysis results. Finally, the interactive visualization module provides the analysts with a coherent view of the changes and patterns in the continuously captured performance data. Through a multi-faceted case study on performance analysis of parallel discrete-event simulation, we demonstrate the effectiveness of our framework for identifying bottlenecks and locating outliers.

Human-centered computing↗

Dosimetry in differentiated thyroid carcinoma (12-1402R)

Purpose: The aim of this study has been to perform a dosimetric study in the treatments of differentiated thyroid cancer (DTC) performed in our center in order to find a dose-effect correlation. Methods: Thirty patients treated for DTC with 3700 MBq of {sup 131}I have been included in this study. For reasons of radiological protection all of them spent two nights as inpatients. Dose rate at 1 m from all patients was measured approximately 20 and 44 h after the administration of the radioiodine and a whole body scan in the gamma camera was performed approximately 1 week later. With those measurements and by using a model of two compartments the activities in thyroid bed remnants and in the whole body were calculated as a function of time. The integration of both activities yields the corresponding cumulated activities. Absorbed doses to thyroid bed remnants and to the whole body can be calculated following the MIRDOSE method-that is, by multiplying the corresponding cumulated activities by the corresponding S factors. Results: The absorbed doses to thyroid bed remnants calculated in this study fall into a very wide range (13-1161 Gy) and showed the highest correlation factors with the following parameters: the absorbed dose rate to thyroid bed remnants, the cumulated activity in thyroid bed remnants, and the maximum radioiodine uptake in thyroid bed remnants. The absorbed doses to the whole body range from 0.12 to 0.23 Gy. The ablation was successful in all patients, and in spite of the wide range of absorbed doses to thyroid bed remnants obtained, no dose-effect correlation could be obtained. Conclusions: Facing DTC treatments from a dosimetric viewpoint in which a predosimetry to calculate the activity of {sup 131}I to be administered is performed is a subject difficult to handle. This statement is based on the fact that although a very wide range of absorbed doses to thyroid bed remnants was obtained (including several absorbed doses well below some dose thresholds previously published to achieve ablation of thyroid bed remnants), ablation of thyroid bed remnants was successful for all patients and therefore no dose-effect correlation could be determined.

60 APPLIED LIFE SCIENCES↗

Computing Bottleneck Structures at Scale for High-Precision Network Performance Analysis

The Theory of Bottleneck Structures is a recently-developed framework for studying the performance of data networks. It describes how local perturbations in one part of the network propagate and interact with others. This framework is a powerful analytical tool that allows network operators to make accurate predictions about network behavior and thereby optimize performance. Previous work implemented a software package for bottleneck structure analysis, but applied it only to toy examples. In this work, we introduce the first software package capable of scaling bottleneck structure analysis to production-size networks. Here, we benchmark our system using logs from ESnet, the Department of Energy's high-performance data network that connects research institutions in the U.S. Using the previously published tool as a baseline, we demonstrate that our system achieves vastly improved performance, constructing the bottleneck structure graphs in 0.21 s and calculating link derivatives in 0.09 s on average. We also study the asymptotic complexity of our core algorithms, demonstrating good scaling properties and strong agreement with theoretical bounds. These results indicate that our new software package can maintain its fast performance when applied to even larger networks. They also show that our software is efficient enough to analyze rapidly changing networks in real time. Overall, we demonstrate the feasibility of applying bottleneck structure analysis to solve practical problems in large, real-world data networks.

benchmark↗

SDU 6 Modeling Study to Support Design Development

In response to Technical Task Request (TTR) HLW-SSF-TTR-2012-0017 (1), SRNL performed modeling studies to evaluate alternative design features for the 32 million gallon Saltstone Disposal Unit (SDU) referred to as SDU 6. This initial modeling study was intended to assess the performance of major components of the structure that are most significant to the PA. Information provided by the modeling will support the development of a SDU 6 Preliminary Design Model and Recommendation Report to be written by SRR Closure and Waste Disposal Authority. Key inputs and assumptions for the modeling were provided to SRNL in SRR-SPT-2011-00113 (2). A table reiterates the base case and four sensitivity case studies requested in this reference. In general, as shown in Table 4, when compared to Vault 2 Case A, the Base Case SDU 6 design produced higher peak fluxes to the water table during the 10,000 year period of analysis but lower peak fluxes within a 15,000 to 20,000 time frame. SDU 6 will contain approximately ten times the inventory of a single Vault 2 and the SDU 6 footprint is comparable to that of a group of four Vault 2 disposal units. Therefore, the radionuclide flux from SDU 6 and that from a single Vault 2 are not directly comparable. A more direct comparison would be to compare the maximum dose obtained at the 100 m boundary from the seven SDU's that will replace the 64 FDC's analyzed in the 2009 PA. This analysis will be performed in the next set of calculations planned for SDU design evaluation. Aquifer transport and dose calculations were not intended to be part of this initial scoping study. However, results from this study do indicate that replacement of the FDC design with SDU would not yield significantly higher peak doses. If the thickness of the SDU 6 floor is increased, peak doses would not occur during the 10,000 year period of analysis.

54 ENVIRONMENTAL SCIENCES↗