Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Advances in imaging, scattering, spectroscopy, and machine learning-aided approaches for multiscale characterization of cementitious systems

Recent progress in methods used in the multiscale characterization of cementitious systems is reviewed, focusing on advances in imaging, scattering, and spectroscopy. The review includes relevant applications and developments in machine learning and other data analytics approaches to enhance characterization. Developments in imaging using light and electron microscopy as well as x-ray (i.e., from synchrotron) methods are summarized. Updates include scanning electron microscopy (SEM), transmission electron microscopy (TEM), tomography, and holography. A critical overview of spectroscopy (e.g., MAS NMR, Raman) and scattering (e.g., neutron, x-ray, synchrotron x-ray) methods is provided, and the intersection of these with imaging is developed (e.g., Raman imaging). Additionally, the paper summarizes recent developments in and implementations of state-of-the-art machine-learning algorithms and data analytics methods for automated, systematic, and/or quantitative analyses of image data sets. The review considers but is not limited to the application of these methods for investigating the hydration and microstructure development of cement phases, low-carbon-footprint cements (e.g., limestone calcined clay cements, LC3), environmental interactions (e.g., ASR) and model systems. Finally, the present work provides a critical presentation of advances in characterization methods that link together the composition and multiscale structure of cementitious materials.

42 ENGINEERING↗

Analysis of X-ray images and spectra (aXis2000): A toolkit for the analysis of X-ray spectromicroscopy data

Spectromicroscopy refers to analytical methods that combine imaging and spectroscopy to provide detailed, spatially resolved analytical information about a sample, such as the type and quantitative spatial distributions of chemical components, geometric or magnetic alignment information, crystal structure, etc. The analysis of X-ray images and spectra (aXis2000) software described in this work provides a set of routines within a single, integrated, graphical-oriented package to read, display, manipulate and analyze spectromicroscopy data, with particular focus on soft X-ray spectromicroscopy methods such as scanning transmission X-ray microscopy (STXM), X-ray photoemission electron microscopy (XPEEM), scanning photoelectron X-ray microscopy (SPEM) and transmission X-ray microscopy (TXM). Here, this free software is described and compared to other software that can provide similar or complementary capabilities. Examples of spectromicroscopic analyses using advanced features of aXis2000 are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect and structural evolution under high-energy ion irradiation informs battery materials design for extreme environments

Understanding defect evolution and structural transformations constitutes a prominent research frontier for ultimately controlling the electrochemical properties of advanced battery materials. Herein, for the first time, we utilize in situ high-energy Kr ion irradiation with transmission electron microscopy to monitor how defects and microstructures evolve in Na- and Li-layered cathodes with 3d transition metals. Our experimental and theoretical analyses reveal that Li-layered cathodes are more resistant to radiation-induced structural transformations, such as amorphization than Na-layered cathodes. The underlying mechanism is the facile formation of Li-transition metal antisite defects in Li-layered cathodes. The quantitative mathematical analysis of the dynamic bright-field imaging shows that defect clusters preferentially align along the Na/Li ion diffusion channels ( a-b planes), which is likely governed by the formation of dislocation loops. Our study provides critical insights into designing battery materials for extreme irradiation environments and understanding fundamental defect dynamics in layered oxides.

25 ENERGY STORAGE↗

Atomic-scale secondary electron imaging for heterogeneous catalysis research

Surface characterization at the atomic scale is essential for understanding the catalytic properties of supported metal nanoparticles. Secondary electron (SE) imaging in scanning transmission electron microscopy (STEM) provides three-dimensional surface topographic information, enabling the characterization of the size, morphology, and distribution of supported nanoparticles. Furthermore, real-time observation of catalyst materials in a gaseous environment would enhance the understanding of catalyst dynamics under operational conditions. Ongoing technical developments in SE-STEM and advancements in computational methods are expected to facilitate atomic-scale surface observations and enable more quantitative and statistical analyses. This progress will not only elucidate fundamental mechanisms at the atomic level but also provide comprehensive and universal insights into catalyst performances. Here, this minireview showcases the recent advancements and research findings in surface-sensitive SE imaging in STEM for the characterization of active catalyst materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Image formation, resolution, and height measurement in scanning ion conductance microscopy

Scanning ion conductance microscopy (SICM) is an emerging tool for the noncontact investigation of biological samples such as live cells. It uses an ion current through the opening of a tapered nanopipette filled with an electrolyte for topography measurements. Despite its successful application to numerous systems no systematic investigation of the image formation process has yet been performed. Here, we use finite element modeling to investigate how the scanning ion conductance microscope images small particles on a planar surface, providing a fundamental characterization of the imaging process. We find that a small particle appears with a height that is only a fraction of its actual height. This has significant consequences for the quantitative interpretation of SICM images. Furthermore, small and low particles are imaged as rings in certain cases. This can cause small, closely spaced particles to appear with a lateral orientation that is rotated by 90 deg. Considering both real space and spatial frequency space we find that a reasonable and useful definition of lateral resolution of SICM is the smallest distance at which two small particles can clearly be resolved from each other in an image. We find that this resolution is approximately equal to three times the inner radius of the pipette tip opening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Analysis of Micro-structural Changes in a Bituminous Coal After Exposure to Supercritical CO{sub 2} and Water

High-volatile bituminous coal samples were reacted in deionized water with supercritical CO{sub 2} (ScCO{sub 2}–water) under simulated in situ pressure and temperature conditions (8 MPa and 40 °C) in unconfined stress state for 14 days, in order to characterize potential CO{sub 2}–water–coal reactions. Micro-structural changes were identified pre- and post-experiment using X-ray powder diffraction (XRD) analysis for powdered coal (mineralogical changes), optical microscopy and scanning electron microscopy (SEM) for polished thin sections (surface feature changes) and micro-CT scanning for a small core (porosity and permeability changes). XRD analysis revealed that carbonic acid leaches out mineral matters in coal, including carbonates (calcite) and silicate minerals (albite, illite and kaolinite). Optical microscopy, SEM and CT images confirmed that the interaction of coal with ScCO{sub 2}–water causes an abundance of micro-cracks to open or propagate in unconfined coal samples. Most micro-cracks preferably propagated along maceral–mineral and maceral–maceral interfaces, which demonstrates that the micro-cracking was caused by differential swelling of different coal lithotypes. Wormhole formation was observed in coal caused by mineral dissolution and hydrocarbon mobilization, which significantly increases coal porosity compared with swelling-induced cracking. 3-D pore network models extracted from CT images show that ScCO{sub 2}–water treatment enlarges the pore and throat size, increases the numbers of pores and throats and improves pore network connectivity. Overall, CO{sub 2}–water–coal interactions under unconfined conditions enhance coal porosity, connectivity and permeability, which can be attributed to the combined effect of micro-cracking, mineral dissolution and hydrocarbon mobilization.

58 GEOSCIENCES↗

Scanning tunneling microscopic analysis of Cu(In,Ga)Se{sub 2} epitaxial layers

Scanning tunneling microscopy (STM) measurements have been made on single-crystal epitaxial layers of CuInSe{sub 2} grown on GaAs substrates. Results were obtained for as-grown, air-exposed, and cleaned surfaces; in situ cleaved surfaces; surfaces sputtered and annealed in the STM system; and samples prepared by a light chemical etch. Conventional constant-current topographs, current-voltage curves, and current imaging tunneling spectroscopy (CITS) scans were obtained. Topographic images show that the surfaces appear rough on the atomic scale and often exhibit regular features consistent with a previously proposed surface ad-dimer reconstruction. CITS scans show a spatially varying energy gap consistent with band-edge fluctuations on a scale of a few atomic spacings. Energy variations were observed in both band edges. Although quantitative description of the magnitude of these fluctuations is difficult, the fluctuations on the atomic scale appear much larger than observed by methods such as photoluminescence, which average over larger volumes.

36 MATERIALS SCIENCE↗

Monitoring reinforcement corrosion and corrosion-induced cracking by X-ray microcomputed tomography method

X-ray microcomputed tomography (X-ray μCT) method is proposed to trace steel corrosion and corrosion-induced cracking in cement paste. Experimental results show it can track the time-dependent development of steel corrosion and corrosion products, as well as the subsequent initiation and propagation of corrosion-induced cracks. Furthermore, the information of corrosion pits, corrosion products, and corrosion-induced cracks can be clearly obtained from the whole specimen by this novel method. Additionally, SEM/EDS results agree closely with image analyses by X-ray μCT. This method provides a new angle to investigate the reinforcement corrosion process and can help to improve the numerical analysis of corrosion-induced damage in reinforced concrete structures. - Highlights: • Reinforcement corrosion and corrosion-induced cracking is traced by X-ray μCT method. • The development of corrosion products can be determined as a function of time and space. • Subsequent initiation and propagation of corrosion-induced cracks can be monitored. • The time-dependent corrosion process can be quantitative analyzed by X-ray μCT measurement.

36 MATERIALS SCIENCE↗

In-situ ion irradiation study of alloy 709 stainless steels with different processing histories

Alloy 709 stainless steel (A709 SS) has gained an increased interest in nuclear applications due to its advanced properties at high temperatures over the widely used Type 316 SS. However, how this alloy behaves under irradiation with concurrent environmental factors, such as mechanical deformation and/or thermal annealing, has not been studied. In this work, we used in-situ ion irradiation inside a transmission electron microscope (TEM) to investigate the effects of irradiation on the microstructures of A709 SS samples with different prior processing histories, including as-received, annealed, and creep-deformed. It was found that, compared to room temperature irradiation, 600 degrees C irradiation led to larger dislocation loop sizes and lower loop densities. Furthermore, with 600 degrees C irradiation, the creep-deformed sample, which had the highest precipitate density and the highest dislocation density, had the smallest loop size and the lowest loop density compared to others. This observation has been rationalized with quantitative evaluation of the sink strength factors in each sample. This study shows that in-service deformation can significantly affect the irradiation performance in structural materials at reactor operating conditions.

36 MATERIALS SCIENCE↗

Moving Beyond p-Type mc-Si: Quantified Measurements of Iron Content and Lifetime of Iron-Rich Precipitates in n-Type Silicon

N-type multicrystalline silicon (mc-Si) is a promising alternative to the dominant p-type mc-Si for solar cells because it combines the cost advantages of mc-Si while benefiting from higher tolerance to transition metal contamination. A detailed understanding of the relative roles of point defect and precipitated transition metals has enabled advanced processing and high minority carrier lifetimes in p-type mc-Si. This contribution extends that fundamental understanding to Fe contamination in n-type mc-Si, helping enable processing of this material into an economical and high-performance photovoltaic device. Finally, by directly correlating micro-photoluminescence-based minority carrier lifetime mapping and synchrotron-based micro-X-ray fluorescence mapping of Fe-rich precipitates, we develop a quantitative, physical understanding of the recombination activity of Fe-rich precipitates in n-type mc-Si.

36 MATERIALS SCIENCE↗

Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research

Three-dimensional (3D) structural analysis is essential to understand the relationship between the structure and function of an object. Many analytical techniques, such as X-ray diffraction, neutron spectroscopy, and electron microscopy imaging, are used to provide structural information. Transmission electron microscopy (TEM), one of the most popular analytic tools, has been widely used for structural analysis in both physical and biological sciences for many decades, in which 3D objects are projected into two-dimensional (2D) images. In many cases, 2D-projection images are insufficient to understand the relationship between the 3D structure and the function of nanoscale objects. Electron tomography (ET) is a technique that retrieves 3D structural information from a tilt series of 2D projections, and is gradually becoming a mature technology with sub-nanometer resolution. Distinct methods to overcome sample-based limitations have been separately developed in both physical and biological science, although they share some basic concepts of ET. Here, this review discusses the common basis for 3D characterization, and specifies difficulties and solutions regarding both hard and soft materials research. It is hoped that novel solutions based on current state-of-the-art techniques for advanced applications in hybrid matter systems can be motivated. Electron tomography produces quantitative 3D reconstructions for biological and physical sciences from sets of 2D projections acquired at different tilting angles in a transmission electron microscope. Finally, state-of-the-art techniques capable of producing 3D representations such as Pt-Pd core-shell nanoparticles and IgG1 antibody molecules are reviewed.

36 MATERIALS SCIENCE↗

Investigation of early growth of calcium hydroxide crystals in cement solution by soft x-ray transmission microscopy

Research on cement hydration was performed at the full-field soft transmission X-ray microscope XM-1 located at beamline 6.1.2 at the Advanced Light Source (ALS) in Berkeley CA which is operated by the Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California. A series of works [1-3] has been conducted using this microscope for the in situ observation and qualitative analysis of through-solution hydration products and products of topochemical reactions, which form in cementitious aqueous solutions. This paper studies the precipitation of the calcium hydroxide (CH) crystals from the cement solution. The analysis of successive images of the hydration process provides critical quantitative information about the growth rate of calcium hydroxide (CH) crystals, the supersaturation ratio, and the kinetic and diffusion coefficients of the growth process. ASTM Type II portland cement and 6% C{sub 4}A{sub 3}{bar S} admixture were mixed in aqueous solution and saturated with respect to CH and gypsum. The C{sub 4}A{sub 3}{bar S} admixture was included in the experimental program because of the general research program on expansive cements, and adding C{sub 4}A{sub 3}{bar S} to portland cement is an efficient method of generating ettringite and significant early-age expansion. The solution/solid materials ratio was 10 cm{sup 3}/g, which is higher than the one existing in regular concrete and mortars; to compensate for this dilution, the solution was originally saturated with CH and gypsum. To allow sufficient transmission of the soft X-rays, a small droplet was taken from the supernatant solution and assembled in the sample holder, and then squeezed between two silicon nitride windows for the analysis. The X-ray optical setup of the microscope XM-1 is described elsewhere [2]. In this experiment, a wavelength of 2.4 nm (516.6 eV) was used. The radiation transmitting the sample was detected using an X-ray CCD camera, with a resolution of 35 nm provided by Fresnel zone plate X-ray optics and magnification factor of about 2000. The recorded images have a circular field of view of approximately 10 {micro}m in diameter. The illumination time per image was in the range of 1 to 14 seconds depending largely on the absorption of the sample. The experimental work was conducted at room temperature T = 298 K.

36 MATERIALS SCIENCE↗

Ultrafast changes in the optical properties of a titanium surface and femtosecond laser writing of one-dimensional quasi-periodic nanogratings of its relief

One-dimensional quasi-periodic nanogratings with spacings in the range from 160 to 600 nm are written on a dry or wet titanium surface exposed to linearly polarized femtosecond IR and UV laser pulses with different surface energy densities. The topological properties of the obtained surface nanostructures are studied by scanning electron microscopy. Despite the observation of many harmonics of the one-dimensional surface relief in its Fourier spectra, a weak decreasing dependence of the first-harmonic wavenumber (nanograting spacing) on the laser fluence is found. Studies of the instantaneous optical characteristics of the material during laser irradiation by measuring the reflection of laser pump pulses and their simulation based on the Drude model taking into account the dominant interband absorption allowed us to estimate the length of the excited surface electromagnetic (plasmon-polariton) wave for different excitation conditions. This wavelength is quantitatively consistent with the corresponding nanograting spacings of the first harmonic of the relief of the dry and wet titanium surfaces. It is shown that the dependence of the first-harmonic nanograting spacing on the laser fluence is determined by a change in the instantaneous optical characteristics of the material and the saturation of the interband absorption along with the increasing role of intraband transitions. Three new methods are proposed for writing separate subwave surface nanogratings or their sets by femtosecond laser pulses using the near-threshold nanostructuring, the forced adjustment of the optical characteristics of the material or selecting the spectral range of laser radiation, and also by selecting an adjacent dielectric.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser ablation of polymer coatings allows for electromagnetic field enhancement mapping around nanostructures

Subdiffraction spatially resolved, quantitative mapping of strongly localized field intensity enhancement on gold nanostructures via laser ablation of polymer thin films is reported. Illumination using a femtosecond laser scanning microscope excites surface plasmons in the nanostructures. The accompanying field enhancement substantially lowers the ablation threshold of the polymer film and thus creates local ablation spots and corresponding topographic modifications of the polymer film. Such modifications are quantified straightforwardly via scanning electron microscopy and atomic force microscopy. Thickness variation in the polymer film enables the investigation of either the initial ablation phase or ablation induced by collective enhancement effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New insight into the role of MMP14 in metabolic balance

Membrane-anchored matrix metalloproteinase 14 (MMP14) is involved broadly in organ development through both its proteolytic and signal-transducing functions. Knockout of Mmp14 (KO) in mice results in a dramatic reduction of body size and wasting followed by premature death, the mechanism of which is poorly understood. Since the mammary gland develops after birth and is thus dependent for its functional progression on systemic and local cues, we chose it as an organ model for understanding why KO mice fail to thrive. A global analysis of the mammary glands’ proteome in the wild type (WT) and KO mice provided insight into an unexpected role of MMP14 in maintaining metabolism and homeostasis. We performed mass spectrometry and quantitative proteomics to determine the protein signatures of mammary glands from 7 to 11 days old WT and KO mice and found that KO rudiments had a significantly higher level of rate-limiting enzymes involved in catabolic pathways. Glycogen and lipid levels in KO rudiments were reduced, and the circulating levels of triglycerides and glucose were lower. Analysis of the ultrastructure of mammary glands imaged by electron microscopy revealed a significant increase in autophagy signatures in KO mice. Finally, Mmp14 silenced mammary epithelial cells displayed enhanced autophagy. Applied to a systemic level, these findings indicate that MMP14 is a crucial regulator of tissue homeostasis. If operative on a systemic level, these findings could explain how Mmp14 KO litter fail to thrive due to disorder in metabolism.

59 BASIC BIOLOGICAL SCIENCES↗

Grain boundary segregation in BCC vanadium-based alloys: Quantum-accurate computed segregation spectra and targeted experimental validations

Grain boundaries are critically important to the material performance of fusion reactor materials such as vanadium, particularly mechanical properties and irradiation resistance. A key challenge to the design and control of grain boundaries in vanadium alloys is the lack of quantitative data on grain boundary segregation. In this study, we combine computational and experimental methods to address this gap. Furthermore, using a machine learning-accelerated quantum mechanics/molecular mechanics approach, we calculated the segregation spectra for 28 transition metal elements in polycrystalline vanadium, and validated these predictions experimentally for a subset of solutes that sample a range of segregation behavior, specifically zirconium, titanium, and tungsten, using analytical transmission electron microscopy. Furthermore, the agreement between experiment and theory highlights the predictive capability of our approach. Critically, this work provides a comprehensive database of quantum-accurate solute segregation enthalpies in vanadium, enabling the development of advanced alloys for fusion reactors applications.

Fusion materials↗

Combining four-point bending and corrosion to map stress-dependent corrosion susceptibility of 316H stainless steel in FLiNaK

Understanding the effect of stress on the corrosion of steels in molten salts is important for material screening and safety assessment of molten salt reactors. We present a method that combines four-point bending with corrosion testing, enabling the mapping of corrosion susceptibility as a function of local stress from a single specimen. Guided by finite element analysis, a four-point bending setup was used to bend a 316H stainless-steel bar under controlled elastic stress during a 100-hour exposure in FLiNaK at 700 °C. Post-exposure characterization using scanning electron microscopy and energy-dispersive X-ray spectroscopy revealed a pronounced correlation between stress and corrosion. Regions under tensile stress exhibited significantly deeper attack depths and greater chromium depletion along grain boundaries, whereas compressive zones showed shallower corrosion cracks. The stress effect is attributed to stress concentration under tensile loading, which promotes chromium dissolution and crack propagation. This technique can be readily applied to other structural alloys, enabling quantitative measurement of corrosion susceptibility as a function of local stress.

316H↗