Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Scalable Experimental Bounds for Entangled Quantum State Fidelities

Estimating the state preparation fidelity of highly entangled states on noisy intermediate-scale quantum (NISQ) devices is important for benchmarking and application considerations. Unfortunately, exact fidelity measurements quickly become prohibitively expensive, as they scale exponentially as O(3 N for N-qubit states, using full state tomography with measurements in all Pauli bases combinations. However, Somma et al.established that the complexity could be drastically reduced when looking at fidelity lower bounds for states that exhibit symmetries, such as Dicke states and GHZ states. These bounds must still be tight enough for larger states to provide reasonable estimations on NISQ devices. For the first time and more than 15 years after the theoretical introduction, we report meaningful lower bounds for the state preparation fidelity of all Dicke states up to N=10 and all GHZ states up to N=20 on Quantinuum H1 ion-trap systems using efficient implementations of recently proposed scalable circuits for these states. Our achieved lower bounds match or exceed previously reported exact fidelities on superconducting systems for much smaller states. Furthermore, we provide evidence that for large Dicke states |$D^{N}_{N/2}\rangle$, we may resort to a GHZ-based approximate state preparation to achieve better fidelity. This work provides a path forward to benchmarking entanglement as NISQ devices improve in size and quality.

97 MATHEMATICS AND COMPUTING↗

Creation of Two-Particle Entanglement in Open Macroscopic Quantum Systems

We consider an open quantum system of N not directly interacting spins (qubits) in contact with both local and collective thermal environments. The qubit-environment interactions are energy conserving. We trace out the variables of the thermal environments and N − 2 qubits to obtain the time-dependent reduced density matrix for two arbitrary qubits. We numerically simulate the reduced dynamics and the creation of entanglement (concurrence) as a function of the parameters of the thermal environments and the number of qubits, N . Our results demonstrate that the two-qubit entanglement generally decreases as N increases. We show analytically that, in the limit N → ∞ , no entanglement can be created. This indicates that collective thermal environments cannot create two-qubit entanglement when many qubits are located within a region of the size of the environment coherence length. We discuss possible relevance of our consideration to recent quantum information devices and biosystems.

Merkli, M.↗

Detection of breast cancer cells using targeted magnetic nanoparticles and ultra-sensitive magnetic field sensors

Introduction: Breast cancer detection using mammography has improved clinical outcomes for many women, because mammography can detect very small (5 mm) tumors early in the course of the disease. However, mammography fails to detect 10 - 25% of tumors, and the results do not distinguish benign and malignant tumors. Reducing the false positive rate, even by a modest 10%, while improving the sensitivity, will lead to improved screening, and is a desirable and attainable goal. The emerging application of magnetic relaxometry, in particular using superconducting quantum interference device (SQUID) sensors, is fast and potentially more specific than mammography because it is designed to detect tumor-targeted iron oxide magnetic nanoparticles. Furthermore, magnetic relaxometry is theoretically more specific than MRI detection, because only target-bound nanoparticles are detected. Our group is developing antibody-conjugated magnetic nanoparticles targeted to breast cancer cells that can be detected using magnetic relaxometry. Methods: To accomplish this, we identified a series of breast cancer cell lines expressing varying levels of the plasma membrane-expressed human epidermal growth factor-like receptor 2 (Her2) by flow cytometry. Anti-Her2 antibody was then conjugated to superparamagnetic iron oxide nanoparticles using the carbodiimide method. Labeled nanoparticles were incubated with breast cancer cell lines and visualized by confocal microscopy, Prussian blue histochemistry, and magnetic relaxometry. Results: We demonstrated a time- and antigen concentration-dependent increase in the number of antibodyconjugated nanoparticles bound to cells. Next, anti Her2-conjugated nanoparticles injected into highly Her2- expressing tumor xenograft explants yielded a significantly higher SQUID relaxometry signal relative to unconjugated nanoparticles. Finally, labeled cells introduced into breast phantoms were measured by magnetic relaxometry, and as few as 1 million labeled cells were detected at a distance of 4.5 cm using our early prototype system. Conclusions: These results suggest that the antibody-conjugated magnetic nanoparticles are promising reagents to apply to in vivo breast tumor cell detection, and that SQUID-detected magnetic relaxometry is a viable, rapid, and highly sensitive method for in vitro nanoparticle development and eventual in vivo tumor detection.

59 BASIC BIOLOGICAL SCIENCES↗

Data for Magnetic Anisotropy due to Localized Structural Defects in Strained Yttrium Iron Garnet Thin Films

This dataset contains electron microscopy, magnetic, and X-ray diffraction characterization data for YIG/YSGG thin films associated with the manuscript "Magnetic anisotropy due to localized structural defects in strained yttrium iron garnet thin films". Characterizations include: scanning electron nano diffraction (SEND, or 4D-STEM), dark field transmission electron microscopy (DF-TEM), energy dispersive X-ray spectroscopy (EDS), ferrimagnetic resonance (FMR), superconducting quantum interference device (SQUID), scanning transmission electron microscopy (STEM), X-ray diffraction (XRD).

Electron microscopy↗

Development of hard masks for reactive ion beam angled etching of diamond

Diamond offers good optical properties and hosts bright color centers with long spin coherence times. Recent advances in angled-etching of diamond, specifically with reactive ion beam angled etching (RIBAE), have led to successful demonstration of quantum photonic devices operating at visible wavelengths. However, larger devices operating at telecommunication wavelengths have been difficult to fabricate due to the increased mask erosion, arising from the increased size of devices requiring longer etch times. We evaluated different mask materials for RIBAE of diamond photonic crystal nanobeams and waveguides, and how their thickness, selectivity, aspect ratio and sidewall smoothness affected the resultant etch profiles and optical performance. We found that a thick hydrogen silesquioxane (HSQ) layer on a thin alumina adhesion layer provided the best etch profile and optical performance. The techniques explored in this work can also be adapted to other bulk materials that are not available heteroepitaxially or as thin films-on-insulator.

36 MATERIALS SCIENCE↗

Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System

A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject’s scalp. We have conducted two MEG experiments on three subjects: assessment of somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial MEG system based on superconducting quantum interference devices (SQUIDs). We cross validated the robustness of our system by calculating the distance between the location of the equivalent current dipole (ECD) yielded by our OPM-based MEG system and the ECD location calculated by the commercial SQUID-based MEG system. We achieved sub-centimeter accuracy for both SEF and AEF responses in all three subjects. Due to the proximity (12 mm) of the OPM channels to the scalp, it is anticipated that future OPM-based MEG systems will offer enhanced spatial resolution as they will capture finer spatial features compared to traditional MEG systems employing SQUIDs.

60 APPLIED LIFE SCIENCES↗

Accelerated microwave-assisted synthesis and in situ X-ray scattering of tungsten-substituted vanadium dioxide (V 1-x W x O 2 )

Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.

36 MATERIALS SCIENCE↗

Synthesis and behavior of bulk iron nitride soft magnets via high-pressure spark plasma sintering

Abstract In this study, dense bulk iron nitrides (Fe x N) were synthesized for the first time ever using spark plasma sintering (SPS) of Fe x N powders. The Fe 4 N phase of iron nitride in particular has significant potential to serve as a new soft magnetic material in both transformer and inductor cores and electrical machines. The density of SPSed Fe x N increased with SPS temperature and pressure. The microstructure of the consolidated bulk Fe x N was characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and superconducting quantum interference device (SQUID) magnetometry. XRD revealed a primary phase of Fe 4 N with secondary phases of Fe 3 N and metallic iron. Finite element analysis (FEA) was also applied to investigate and explain localized heating and temperature distribution during SPS. The effects of processing on interface bonding formation and phase evolution were investigated and discussed in detail to provide insight into fundamental phenomena and microstructural evolution in SPSed Fe x N. Graphic abstract

36 MATERIALS SCIENCE↗

Atomic magnetometer for human magnetoencephalograpy.

We have developed a high sensitivity (<5 fTesla/{radical}Hz), fiber-optically coupled magnetometer to detect magnetic fields produced by the human brain. This is the first demonstration of a noncryogenic sensor that could replace cryogenic superconducting quantum interference device (SQUID) magnetometers in magnetoencephalography (MEG) and is an important advance in realizing cost-effective MEG. Within the sensor, a rubidium vapor is optically pumped with 795 laser light while field-induced optical rotations are measured with 780 nm laser light. Both beams share a single optical axis to maximize simplicity and compactness. In collaboration with neuroscientists at The Mind Research Network in Albuquerque, NM, the evoked responses resulting from median nerve and auditory stimulation were recorded with the atomic magnetometer and a commercial SQUID-based MEG system with signals comparing favorably. Multi-sensor operation has been demonstrated with two AMs placed on opposite sides of the head. Straightforward miniaturization would enable high-density sensor arrays for whole-head magnetoencephalography.

42 ENGINEERING↗

SQUID Noise Measurements for CDMS Detectors

The Cryogenic Dark Matter Search is the second iteration of SuperCDMS dark matter experiments with an increase in sensitivity to low mass dark matter particles. The experiment uses germanium and silicon crystals which are capable of detecting both the charges and phonon signals produced from dark matter interactions. Detectors are housed in towers which are then housed in a cryogenics system able to cool down to 15 mK. The experiment will be installed in an underground lab in Sudbury, Ontario in order to shield from cosmic rays and background radiation. SQUIDs are an acronym for superconducting quantum interference devices that are capable of detecting extremely small magnetic fields. A typical dark matter nuclear recoil interaction can be detected by a TES (transition edge sensor). SQUIDs are then used to read out and amplify the signals generated by the TES. It is essential that these SQUIDS add negligible noise to the intrinsic noise of the TES to be able to distinguish the internal circuit noise from a true dark matter interaction signal. The noise was measured while varying several parameters. Both an Agilent and an SRS785 spectrum analyzer were used. Furthermore, an amplifier which amplified the signal 10x was tested. The Agilent machine produced more noticeably greater noise in the region from 100-1000 Hz, whereas the SRS785 did not. Next, the amplifier was tested and the signal generated was analyzed in comparison to the original signal. The amplifier did not produce any noticeable additional noise over the intrinsic noise of the SQUID. Further work includes testing to see if detectors with higher voltage sources can also be used with negligible noise.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing Quantum Levitation of ICF Capsules Coated with MgB 2 Thin Films

Current inertial confinement fusion (ICF) capsule support technologies create implosion perturbations which reduce fusion yield, driving the search for new support paradigms. Quantum levitation of the capsule will eliminate the requirement of a physical support structure, increasing fusion yield. The application of an external magnetic field to a capsule coated with a superconducting film can provide the necessary conditions for levitation. Magnesium diboride (MgB 2 ) is an attractive option for ICF applications as it has a high reported superconducting transition temperature of 39 K and is a low Z compound. This project is part of an ongoing effort which seeks to coat ICF capsules with a thin layer of superconducting MgB 2 . This project studied the synthesis of MgB 2 and diffusion/reaction kinetics of B/Mg/B m ultilayer thin films. These films were sputter deposited on flat glassy carbon substrates. Films were annealed in a tube furnace at temperatures between 400 °C and 650 °C for a total of 29 hours with film characterization done at predetermined intervals. At each interval, superconducting properties of the samples were evaluated with superconducting quantum interference device (SQUID) magnetometry, while Rutherford backscattering (RBS) with 2 MeV 4 He + ions was done to determine the composition and depth profile of the films. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to characterize surface morphology. Superconducting behavior was observed in thin films annealed at and above 450 °C. Formation of superconducting MgB 2 at 450 °C h as not been previously reported below 500 °C. The surface of the samples annealed at 500 °C and below was smooth with a measured roughness of ~3 nm. After 29 hours of annealing time, the 450 °C sample had a transition temperature of 27.3 K. The highest transition temperature measured was 30.9 K and was associated with a sample annealed for 29 hours at 650 °C. Transition temperatures were weakly positively correlated with annealing temperature and showed dependence on initial structural quality and oxygen contamination. Current research is attempting to synthesize superconducting MgB 2 coatings on spherical Si beads with the findings of this study. Future efforts are focused on the construction and testing of a levitation apparatus.

36 MATERIALS SCIENCE↗

Nitrogen Vacancy Center in Diamond for the Stress and Field Sensing Applications

The nitrogen-vacancy (NV) center in a nanodiamond (ND) crystal is a promising material for quantum information processing, sensing, and computing applications. It is one of the best candidate materials for quantum sensing and metrology expected to work at elevated temperatures and pressures conditions. We computationally show the effect of strain on the defect band edges and band gaps in the NV center diamond. A low energy Hamiltonian is developed for the ±1 spin manifold at the ground state. We show the quantum sensing device is a few orders of magnitude superior in sensing than the traditional optical sensing devices. We also discuss experimental results from the optically detected magnetic resonance (ODMR) and the spin relaxometry for the field sensing applications. The presentation concludes by providing a model for free spins detection of the rare earth ions.

field sensing applications↗

Properties of Electronic Materials

This final technical report summarizes the research conducted under DOE Grant DE-SC0002623, "Properties of Electronic Materials," led by Principal Investigator Shengbai Zhang at Rensselaer Polytechnic Institute. Over the 16-year period, the project employed first-principles computational methods to investigate the structural, electronic, and dynamic properties of a wide range of electronic materials, with applications in energy technologies, optoelectronics, and data storage. Key areas included topological insulators, phase-change materials, graphene and two-dimensional systems, perovskites for photovoltaics, defect engineering in semiconductors, kagome lattices, and ultrafast carrier dynamics. The research resulted in 115 peer-reviewed publications, advancing fundamental understanding of material behaviors at the atomic scale and contributing to innovations in renewable energy, memory devices, and quantum materials. Findings have implications for improving energy efficiency, developing lead-free solar cells, and enabling high-speed data processing. The work has trained numerous graduate students and postdocs, fostering the next generation of computational materials scientists. The original goals were to develop theoretical models and computational tools to predict and optimize electronic properties of materials for energy applications. All objectives were accomplished, with no major departures from planned methodologies. Challenges in computational scaling were addressed through access to high-performance computing resources.

36 MATERIALS SCIENCE↗

Improved Charge Sensing on a SiMOS Double Quantum Dot using a Cryogenic Skipper Readout ASIC (Quandarum)

Major outstanding questions in high-energy physics such as the nature of dark matter and the existence of interactions beyond the standard model require new measurement techniques which are extremely sensitive to minute electromagnetic fields. An array of entangled spin qubits is a promising system for building novel detectors due to its combination of sensitivity and controllability. CMOS-based electron spin qubits, which have demonstrated the operational requirements for fault-tolerant quantum computing [1], offer a particular opportunity due to their compatibility with classical electronics, which allows the leveraging of decades of development of low-noise cryogenic detectors for physics. In this work, we combine a SiMOS double-quantum dot device architecture with a state-of-the-art cryoelectronic readout circuit [2-3] aimed to demonstrate improved charge readout using a single-electron transistor (SET). We identify the design characteristics for an SET that facilitate the use of on-chip classical electronics as a low-power, high-bandwidth first amplification stage and explore opportunities for sensor-readout co-design to minimize noise. This is the first of a series of steps to demonstrate high-fidelity readout of a large array of spin qubit with enough sensitivity to probe processes of interest for the investigation of beyond-standard-model physics.

Quinn, Adam [Fermilab]↗

SQUID-Detected MRI in the Limit of Zero Static Field

This thesis describes an implementation of the so-called"zero-field MRI" (ZFMRI) pulse sequence, which allows for imaging in an arbitrarily low B 0 field. The ZFMRI sequence created an effective unidirectional gradient field by using a train of pi pulses to average out the concomitant gradient components during encoding. The signals were acquired using a low-transition temperature dc Superconducting QUantum Interference Device (low-Tc dc SQUID) coupled to a first-order axial gradiometer. The experiments were carried out in a liquid helium dewar which was magnetically shielded with a single-layer mu-metal can around the outside and a superconducting Pb can contained within the helium space. We increased the filling factor of the custom-made, double-walled Pyrex insert by placing the liquid alcohol sample, at a temperature of approximately -50 degrees C, at the center of one loop of the superconducting gradiometer, which was immersed in the helium bath.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUID magnetometry from nanometer to centimeter length scales

The development of Superconducting QUantum Interference Device (SQUID)-based magnetometer for two applications, in vivo prepolarized, ultra-low field MRI of humans and dispersive readout of SQUIDs for micro- and nano-scale magnetometery, are the focus of this thesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

“Seeing Is Believing”—In-Depth Analysis by Co-Imaging of Periodically-Poled X-Cut Lithium Niobate Thin Films

Nonlinear and quantum optical devices based on periodically-poled thin film lithium niobate (PP-TFLN) have gained considerable interest lately, due to their significantly improved performance as compared to their bulk counterparts. Nevertheless, performance parameters such as conversion efficiency, minimum pump power, and spectral bandwidth strongly depend on the quality of the domain structure in these PP-TFLN samples, e.g., their homogeneity and duty cycle, as well as on the overlap and penetration depth of domains with the waveguide mode. Hence, in order to propose improved fabrication protocols, a profound quality control of domain structures is needed that allows quantifying and thoroughly analyzing these parameters. In this paper, we propose to combine a set of nanometer-to-micrometer-scale imaging techniques, i.e., piezoresponse force microscopy (PFM), second-harmonic generation (SHG), and Raman spectroscopy (RS), to access the relevant and crucial sample properties through cross-correlating these methods. Based on our findings, we designate SHG to be the best-suited standard imaging technique for this purpose, in particular when investigating the domain poling process in x-cut TFLNs. While PFM is excellently recommended for near-surface high-resolution imaging, RS provides thorough insights into stress and/or defect distributions, as associated with these domain structures. In this context, our work here indicates unexpectedly large signs for internal fields occurring in x-cut PP-TFLNs that are substantially larger as compared to previous observations in bulk LN.

Reitzig, Sven (ORCID:0000000286970379)↗