Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Evaluation of electropolished stainless steel electrodes for use in DC high voltage photoelectron guns

DC high voltage photoelectron guns are used to produce polarized electron beams for accelerator-based nuclear and high-energy physics research. Low-level field emission (∼nA) from the cathode electrode degrades the vacuum within the photogun and reduces the photoelectron yield of the delicate GaAs-based photocathode used to produce the electron beams. High-level field emission (>μA) can cause significant damage the photogun. To minimize field emission, stainless steel electrodes are typically diamond-paste polished, a labor-intensive process often yielding field emission performance with a high degree of variability, sample to sample. As an alternative approach and as comparative study, the performance of electrodes electropolished by conventional commercially available methods is presented. Our observations indicate the electropolished electrodes exhibited less field emission upon the initial application of high voltage, but showed less improvement with gas conditioning compared to the diamond-paste polished electrodes. In contrast, the diamond-paste polished electrodes responded favorably to gas conditioning, and ultimately reached higher voltages and field strengths without field emission, compared to electrodes that were only electropolished. The best performing electrode was one that was both diamond-paste polished and electropolished, reaching a field strength of 18.7 MV/m while generating less than 100 pA of field emission. The authors speculate that the combined processes were the most effective at reducing both large and small scale topography. However, surface science evaluation indicates topography cannot be the only relevant parameter when it comes to predicting field emission performance.

42 ENGINEERING↗

Some Issues in Uncertainty Quantification and Parameter Tuning: A Case Study of Convective Parameterization Scheme in the WRF Regional Climate Model

The current tuning process of parameters in global climate models is often performed subjectively, or treated as an optimization procedure to minimize the difference between model fields and observations. The later approach may be generating a set of tunable parameters that approximate the observed climate but via an unrealistic balance of physical processes and/or compensating errors over different regions in the globe. In this study, we run the Weather Research and Forecasting (WRF) regional model constrained by the reanalysis data over the Southern Great Plains (SGP) where abundant observational data from various resources are available for calibration of the input parameters and validation of the model results. Our goal is to quantify the uncertainty ranges and identify the optimal values of five key input parameters in a new Kain-Frisch (KF) convective parameterization scheme incorporated in the WRF model. A stochastic sampling algorithm, Multiple Very Fast Simulated Annealing (MVFSA), is employed to efficiently sample the input parameters in KF scheme based on the skill score so that the algorithm progressively moves toward regions of the parameter space that minimize model errors. The results based on the WRF simulations with 25-km grid spacing over the SGP show that the model bias for precipitation can be significantly reduced by using five optimal parameters identified by the MVFSA algorithm. The model performance is very sensitive to downdraft and entrainment related parameters and consumption time of Convective Available Potential Energy (CAPE). Simulated convective precipitation decreases as the ratio of downdraft to updraft flux increases. Larger CAPE consumption time results in less convective but more stratiform precipitation. The simulation using optimal parameters obtained by only constraining precipitation generates positive impact on the other output variables, such as temperature and wind. By using the optimal parameters obtained at 25 km simulation, both the magnitude and spatial pattern of simulated precipitation are improved at 12-km spatial resolution. The optimal parameters identified from the SGP region have also improved the simulation of precipitation when moving model domain to another region with a different climate regime (i.e. North America monsoon region). These results suggest the improvement of precipitation simulation by using the optimal parameters remains when the model domain or spatial resolution is changed.

54 ENVIRONMENTAL SCIENCES↗

A high-transparency, micro-patternable chip for X-ray diffraction analysis of microcrystals under native growth conditions

A highly X-ray-transparent, silicon nitride-based device has been designed and fabricated to harvest protein microcrystals for high-resolution X-ray diffraction data collection using microfocus beamlines and XFELs. Microcrystals present a significant impediment to the determination of macromolecular structures by X-ray diffraction methods. Although microfocus synchrotron beamlines and X-ray free-electron lasers (XFELs) can enable the collection of interpretable diffraction data from microcrystals, there is a need for efficient methods of harvesting small volumes (<2 µl) of microcrystals grown under common laboratory formats and delivering them to an X-ray beam source under native growth conditions. One approach that shows promise in overcoming the challenges intrinsic to microcrystal analysis is to pair so-called ‘fixed-target’ sample-delivery devices with microbeam-based X-ray diffraction methods. However, to record weak diffraction patterns it is necessary to fabricate devices from X-ray-transparent materials that minimize background scattering. Presented here is the design of a new micro-diffraction device consisting of three layers fabricated from silicon nitride, photoresist and polyimide film. The chip features low X-ray scattering and X-ray absorption properties, and uses a customizable blend of hydrophobic and hydrophilic surface patterns to help localize microcrystals to defined regions. Microcrystals in their native growth conditions can be loaded into the chips with a standard pipette, allowing data collection at room temperature. Diffraction data collected from hen egg-white lysozyme microcrystals (10–15 µm) loaded into the chips yielded a complete, high-resolution (<1.6 Å) data set sufficient to determine a high-quality structure by molecular replacement. The features of the chip allow the rapid and user-friendly analysis of microcrystals grown under virtually any laboratory format at microfocus synchrotron beamlines and XFELs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

36 MATERIALS SCIENCE↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Optimal structure and parameter learning of Ising models

Reconstruction of the structure and parameters of an Ising model from binary samples is a problem of practical importance in a variety of disciplines, ranging from statistical physics and computational biology to image processing and machine learning. The focus of the research community shifted toward developing universal reconstruction algorithms that are both computationally efficient and require the minimal amount of expensive data. Here, we introduce a new method, interaction screening, which accurately estimates model parameters using local optimization problems. The algorithm provably achieves perfect graph structure recovery with an information-theoretically optimal number of samples, notably in the low-temperature regime, which is known to be the hardest for learning. Here, the efficacy of interaction screening is assessed through extensive numerical tests on synthetic Ising models of various topologies with different types of interactions, as well as on real data produced by a D-Wave quantum computer. Finally, this study shows that the interaction screening method is an exact, tractable, and optimal technique that universally solves the inverse Ising problem.

97 MATHEMATICS AND COMPUTING↗

Urinary levels of triclosan and triclocarban in several Asian countries, Greece and the USA: Association with oxidative stress

Highlights: • Triclosan and triclocarban were analyzed in 430 urine samples collected from 9 countries. • Triclosan concentrations as high as 1600 ng/mL were found in urine. • Age and gender related differences in triclosan levels were minimal. • TCC levels were marginally correlated with the oxidative stress marker, 8OHdG. Triclosan (TCS) and Triclocarban (TCC) are widely used as antimicrobial preservatives in personal care products (PCPs). Because of their potential for endocrine disrupting effects, human exposure to these chemicals is a concern. Biomonitoring studies of human exposure to TCS and TCC have shown widespread exposure of populations in western European countries and the USA. However, exposure to TCC and TCS by populations in Asian countries is less well known. In this study, concentrations of TCS and TCC were determined in human urine collected from seven Asian countries (China, India, Korea, Kuwait, Japan, Saudi Arabia, and Vietnam), and Greece and the USA. A total of 430 urine samples were analyzed for TCS and TCC, of which 355 (83%) and 82 (19%), respectively, contained measurable levels of these chemicals. The overall geometric mean [GM] concentrations of TCS and TCC, were 1.36 and 0.03 ng/mL, respectively. The highest mean concentration of TCS was found in urine from China (100 ng/mL) and the lowest concentration was found in urine from Vietnam (2.34 ng/mL). We also analyzed urinary 8-OHdG, a marker of oxidative stress, to elucidate the association with TCS and TCC levels for samples from Saudi Arabia (n=130) and a positive correlation between Ln-transformed TCC levels and 8-OHdG was found, although this was not statistically significant. This is the first study to report urinary levels of TCS and TCC in several Asian countries, especially for Vietnam, Kuwait, and Japan.

54 ENVIRONMENTAL SCIENCES↗

THE EVOLUTION OF THE STAR FORMATION RATE OF GALAXIES AT 0.0 {<=} z {<=} 1.2

We present the 24 {mu}m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 {<=} z {<=} 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 {mu}m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg{sup 2}), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 {mu}m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 {mu}m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 {mu}m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-ray emission. Optical emission line diagnostics are considered for AGN identification, but we find that 24 {mu}m emission from optically selected AGNs is usually from star-forming activity and therefore should not be excluded. The evolution of the 24 {mu}m LF of star-forming galaxies for redshifts of z {<=} 0.65 is consistent with a pure luminosity evolution where the characteristic 24 {mu}m luminosity evolves as (1 + z){sup 3.8{+-}0.3}. We extend our evolutionary study to encompass 0.0 {<=} z {<=} 1.2 by combining our data with that of the Far-Infrared Deep Extragalactic Legacy Survey. Over this entire redshift range, the evolution of the characteristic 24 {mu}m luminosity is described by a slightly shallower power law of (1 + z){sup 3.4{+-}0.2}. We find a local star formation rate density of (1.09 {+-} 0.21) x 10{sup -2} M {sub sun} yr{sup -1} Mpc{sup -3}, and that it evolves as (1 + z){sup 3.5{+-}0.2} over 0.0 {<=} z {<=} 1.2. These estimates are in good agreement with the rates using optical and UV fluxes corrected for the effects of intrinsic extinction in the observed sources. This agreement confirms that star formation at z {approx}< 1.2 is robustly traced by 24 {mu}m observations and that it largely occurs in obscured regions of galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrons, gamma rays, and beta particles interactions with IIaO films flown on Astro I and Astro II and comparison with IIaO flown on the get-away-special STS-7

The current requirements for the Laboratory for Astronomy and Solar Physics, sends rocket satellites and in the near future will involve flights in the shuttle to the upper reaches of the Earth's atmosphere where they will be subjected to the atomic particles and electromagnetic radiation produced by the Sun and other cosmic radiation. It is therefore appropriate to examine the effect of neutrons, gamma rays, beta particles, and X-rays on the film currently being used by the Laboratory for current and future research requirements. It is also hoped by examining these particles in their effect that we will have simulated the space environment of the rockets, satellites, and shuttles. Several samples of the IIaO film were exposed to a neutron howitzer with a source energy of approximately 106 neutrons/steradians. We exposed several samples of the film to a 10 second blast of neutrons in both metal and plastic containers which exhibited higher density readings which indicated the possibility of some secondary nuclear interactions between neutrons and the aluminum container. The plastic container showed some variations at the higher densities. Exposure of the samples of IIaO film to a neutron beam of approximately 10 neutrons per steradians for eight minutes produces approximately a 13% difference in the density readings of the dark density grids. It is not noticeable that at the lighter density grid the neutrons have minimal effects, but on a whole the trend of the eight minute exposed IIaO film density grids at the darker end had a 7.1% difference than the control. Further analysis is anticipated by increasing the exposure time. Two sets of film were exposed to a beta source in a plastic container. The beta source was placed at the bottom so that the cone of rays striking the film would be conical for a period of seven days. It was observed in the films, designated 4a and 4b, a dramatic increase in the grid densities had occurred. The attenuation of beta particles due to the presence of air were observed. The darker density grids, whose positions were the furthest from the beta source, displayed minimal fluctuations as compared with the control. It is suspected that the orientation of the film in the cansister with the beta source is the key factor responsible for the dramatic increases of the lighter density grids. Emulsions 3a and 3b exposed for a period of six days with the grid orientation reserved produced substantial differences in the darker grids as shown in the graphs. There is a great deal of fluctuations in this sample between the beta exposed density grids and the control density grids. The lighter density grids whose orientations were reversed displays minimal fluctuations due to the presence of this beta source and the attenuation that is taking place.

Hammond, Ernest C., Jr.↗

The evolutionary rate dynamically tracks changes in HIV-1 epidemics

Large-sequence datasets provide an opportunity to investigate the dynamics of pathogen epidemics. Thus, a fast method to estimate the evolutionary rate from large and numerous phylogenetic trees becomes necessary. Based on minimizing tip height variances, we optimize the root in a given phylogenetic tree to estimate the most homogenous evolutionary rate between samples from at least two different time points. Simulations showed that the method had no bias in the estimation of evolutionary rates and that it was robust to tree rooting and topological errors. We show that the evolutionary rates of HIV-1 subtype B and C epidemics have changed over time, with the rate of evolution inversely correlated to the rate of virus spread. For subtype B, the evolutionary rate slowed down and tracked the start of the HAART era in 1996. Subtype C in Ethiopia showed an increase in the evolutionary rate when the prevalence increase markedly slowed down in 1995. Thus, we show that the evolutionary rate of HIV-1 on the population level dynamically tracks epidemic events.

59 BASIC BIOLOGICAL SCIENCES↗

Bayesian estimation of Karhunen–Loève expansions; A random subspace approach

One of the most widely-used statistical procedures for dimensionality reduction of high dimensional random fields is Principal Component Analysis (PCA), which is based on the Karhunen-Lo eve expansion (KLE) of a stochastic process with finite variance. The KLE is analogous to a Fourier series expansion for a random process, where the goal is to find an orthogonal transformation for the data such that the projection of the data onto this orthogonal subspace is optimal in the L 2 sense, i.e, which minimizes the mean square error. In practice, this orthogonal transformation is determined by performing an SVD (Singular Value Decomposition) on the sample covariance matrix or on the data matrix itself. Sampling error is typically ignored when quantifying the principal components, or, equivalently, basis functions of the KLE. Furthermore, it is exacerbated when the sample size is much smaller than the dimension of the random field. In this paper, we introduce a Bayesian KLE procedure, allowing one to obtain a probabilistic model on the principal components, which can account for inaccuracies due to limited sample size. The probabilistic model is built via Bayesian inference, from which the posterior becomes the matrix Bingham density over the space of orthonormal matrices. We use a modified Gibbs sampling procedure to sample on this space and then build a probabilistic Karhunen-Lo eve expansions over random subspaces to obtain a set of low-dimensional surrogates of the stochastic process. We illustrate this probabilistic procedure with a finite dimensional stochastic process inspired by Brownian motion.

97 MATHEMATICS AND COMPUTING↗

Impacts of annealing treatment on the microstructure of U-Mo monolithic fuel plates

The objective of this paper is to analyze the effect of different heat treatments on the fuel microstructure and texture in laboratory scale monolithic U-Mo fuel plates. Such analyses are relevant as they could possibly inform future fabrication methods for the optimization of microstructure and of material properties to ultimately improve fuel performance during irradiation. For this reason, detail characterization including Energy x-ray dispersive spectroscopy (EDS) and electron backscattered diffraction (EBSD) techniques were applied on U-Mo plates fabricated with different heat treatments to understand the influence of fabrication on fuel microstructure. Here, U-Mo fresh fuel specimens with or without annealing treatments (homogenization and stress release annealing) after rolling were analyzed in this work. In this study for the first time EBSD was systematically used to analyze the heat treatments influence on texture present in fresh fuel monolithic U-Mo fuel plates. Such changes were connected to other known microstructural and chemical changes. In this work minimization of molybdenum concentration variation and gamma phase decomposition of the U-Mo fuel core after homogenization was observed. Also, an increase in the interaction layer of the U-Mo fuel core with the Zr interlayer diffusion barrier was observed with the UZr 2 growing up to 1 µm in thickness. Such microstructural changes were aligned to the changes in texture and grain structure. Indeed, common texture observed in body-centered cubic (BCC) metal after cold rolling (e.g., α, ξ, γ fibers) were minimized by the annealing/homogenization process. Moreover, grain structure was influenced by the fabrication route with elongated grains formed in the rolled sample and equiaxed grains found after annealing. Such features are relevant since the formation of microstructural features formed during fuel fabrication can impact fuel performance in reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data collection from crystals grown in microfluidic droplets

Protein crystals grown in microfluidic droplets have been shown to be an effective and robust platform for storage, transport and serial crystallography data collection with a minimal impact on diffraction quality. Single macromolecular microcrystals grown in nanolitre-sized droplets allow the very efficient use of protein samples and can produce large quantities of high-quality samples for data collection. However, there are challenges not only in growing crystals in microfluidic droplets, but also in delivering the droplets into X-ray beams, including the physical arrangement, beamline and timing constraints and ease of use. Here, the crystallization of two human gut microbial hydrolases in microfluidic droplets is described: a sample-transport and data-collection approach that is inexpensive, is convenient, requires small amounts of protein and is forgiving. It is shown that crystals can be grown in 50–500 pl droplets when the crystallization conditions are compatible with the droplet environment. Local and remote data-collection methods are described and it is shown that crystals grown in microfluidics droplets and housed as an emulsion in an Eppendorf tube can be shipped from the US to the UK using a FedEx envelope, and data can be collected successfully. Details of how crystals were delivered to the X-ray beam by depositing an emulsion of droplets onto a silicon fixed-target serial device are provided. After three months of storage at 4°C, the crystals endured and diffracted well, showing only a slight decrease in diffracting power, demonstrating a suitable way to grow crystals, and to store and collect the droplets with crystals for data collection. This sample-delivery and data-collection strategy allows crystal droplets to be shipped and set aside until beamtime is available.

59 BASIC BIOLOGICAL SCIENCES↗

Robot for Investigations and Assessments of Nuclear Areas

RIANA is a remote controlled Robot dedicated for Investigations and Assessments of Nuclear Areas. The development of RIANA is motivated by the need to have at disposal a proven robot, tested in hot cells; a robot capable of remotely investigate and characterise the inside of nuclear facilities in order to collect efficiently all the required data in the shortest possible time. It is based on a wireless medium sized remote carrier that may carry a wide variety of interchangeable modules, sensors and tools. It is easily customised to match specific requirements and quickly configured depending on the mission and the operator's preferences. RIANA integrates localisation and navigation systems. The robot will be able to generate / update a 2D map of its surrounding and exploring areas. The position of the robot is given accurately on the map. Furthermore, the robot will be able to autonomously calculate, define and follow a trajectory between 2 points taking into account its environment and obstacles. The robot is configurable to manage obstacles and restrict access to forbidden areas. RIANA allows an advanced control of modules, sensors and tools; all collected data (radiological and measured data) are displayed in real time in different format (chart, on the generated map...) and stored in a single place so that may be exported in a convenient format for data processing. This modular design gives RIANA the flexibility to perform multiple investigation missions where humans cannot work such as: visual inspections, dynamic localization and 2D mapping, characterizations and nuclear measurements of floor and walls, non destructive testing, samples collection: solid and liquid. The benefits of using RIANA are: - reducing the personnel exposures by limiting the manual intervention time, - minimizing the time and reducing the cost of investigation operations, - providing critical inputs to set up and optimize cleanup and dismantling operations. (authors)

42 ENGINEERING↗

From neutron star observables to the equation of state. I. An optimal parametrization

The increasing number and precision of measurements of neutron star masses, radii, and, in the near future, moments of inertia offer the possibility of precisely determining the neutron star equation of state (EOS). One way to facilitate the mapping of observables to the EOS is through a parametrization of the latter. We present here a generic method for optimizing the parametrization of any physically allowed EOS. We use mock EOS that incorporate physically diverse and extreme behavior to test how well our parametrization reproduces the global properties of the stars, by minimizing the errors in the observables of mass, radius, and the moment of inertia. We find that using piecewise polytropes and sampling the EOS with five fiducial densities between ∼1–8 times the nuclear saturation density results in optimal errors for the smallest number of parameters. Specifically, it recreates the radii of the assumed EOS to within less than 0.5 km for the extreme mock EOS and to within less than 0.12 km for 95% of a sample of 42 proposed, physically motivated EOS. Such a parametrization is also able to reproduce the maximum mass to within 0.04 M{sub ⊙} and the moment of inertia of a 1.338 M{sub ⊙} neutron star to within less than 10% for 95% of the proposed sample of EOS.

79 ASTRONOMY AND ASTROPHYSICS↗

A tool for cutting ultra thin slits in metals

Tool produces slits of 0.0305 mm widths in materials up to RC 50 hardness, minimizes material waste and improves precision. Device may be used for general metal cutting and for producing simulated cracks in metal samples used in fatigue tests.

Mcmahon, W.↗

A minimax technique for time-domain design of preset digital equalizers using linear programming

A linear programming technique is presented for the design of a preset finite-impulse response (FIR) digital filter to equalize the intersymbol interference (ISI) present in a baseband channel with known impulse response. A minimax technique is used which minimizes the maximum absolute error between the actual received waveform and a specified raised-cosine waveform. Transversal and frequency-sampling FIR digital filters are compared as to the accuracy of the approximation, the resultant ISI and the transmitted energy required. The transversal designs typically have slightly better waveform accuracy for a given distortion; however, the frequency-sampling equalizer uses fewer multipliers and requires less transmitted energy. A restricted transversal design is shown to use the least number of multipliers at the cost of a significant increase in energy and loss of waveform accuracy at the receiver.

Vaughn, G. L.↗