Search NASA⌕ Search

SEARCH · Search NASA

Results for “squeezing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,304 records · Page 73

RHIC PERFORMANCE DURING THE FY10 200 GeV Au+Au HEAVY ION RUN

Since the last successful RHIC Au+Au run in 2007 (Run-7), the RHIC experiments have made numerous detector improvements and upgrades. In order to benefit from the enhanced detector capabilities and to increase the yield of rare events in the acquired heavy ion data a significant increase in luminosity is essential. In Run-7 RHIC achieved an average store luminosity of <L> = 12 x 10{sup 26} cm{sup -2} s{sup -1} by operating with 103 bunches (out of 111 possible), and by squeezing to {beta}* = 0.85 m. This year, Run-10, we achieved <L> = 20 x 10{sup 26} cm{sup -2} s{sup -1}, which put us an order of magnitude above the RHIC design luminosity. To reach these luminosity levels we decreased {beta}* to 0.75 m, operated with 111 bunches per ring, and reduced longitudinal and transverse emittances by means of bunched-beam stochastic cooling. In addition we introduced a lattice to suppress intra-beam scattering (IBS) in both RHIC rings, upgraded the RF control system, and separated transition crossing times in the two rings. We present an overview of the changes and the results of Run-10 performance.

43 PARTICLE ACCELERATORS↗

Parallel Quantum-Enhanced Sensing

Quantum metrology takes advantage of quantum correlations to enhance the sensitivity of sensors and measurement techniques beyond their fundamental classical limit, given by the shot-noise limit. The use of both temporal and spatial correlations present in quantum states of light can extend quantum-enhanced sensing to a parallel configuration that can simultaneously probe an array of sensors or independently measure multiple parameters. To this end, we use multispatial-mode bright twin beams of light, which are characterized by independent quantum-correlated spatial subregions in addition to quantum temporal correlations, to probe a four-sensor quadrant plasmonic array. We show that it is possible to independently and simultaneously measure local changes in refractive index for all four sensors with a quantum enhancement in sensitivity in the range of 22% to 24% over the corresponding classical configuration. Finally, these results provide a first step toward highly parallel spatially resolved quantum-enhanced sensing techniques and pave the way toward more complex quantum sensing and quantum imaging platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Saturating the one-axis twisting quantum Cramér-Rao bound with a total spin readout

We show that the lowest quantum Cramér-Rao bound achievable in interferometry with a one-axis twisted spin coherent state is saturated by the asymptotic method of moments error of a protocol that uses one call to the one-axis twisting, one call to time-reversed one-axis twisting, and a final total spin measurement (i.e., a twist-untwist protocol). The result is derived by first showing that the metrological phase diagram for one-axis twisting is asymptotically characterized by a single quantum Fisher information value N(N + 1)/2 for all times, then constructing a twist-untwist protocol having a method of moments error that saturates this value. The case of finite-range one-axis twisting is similarly analyzed, and a simple functional form for the metrological phase diagram is found in both the short-range and long-range interaction regimes. Numerical evidence suggests that the finite-range analogues of twist-untwist protocols can exhibit a method of moments error that asymptotically saturates the lowest quantum Cramér-Rao bound achievable in interferometry with finite-range one-axis twisted spin coherent states for all interaction times.

36 MATERIALS SCIENCE↗

Parametric amplification of spin-motion coupling in three-dimensional trapped-ion crystals

Three-dimensional (3D) crystals offer a route to scaling up trapped-ion systems for quantum sensing and quantum simulation applications; however, engineering coherent spin-motion couplings and effective spin-spin interactions in large crystals poses technical challenges associated with decoherence and prolonged timescales to generate appreciable entanglement. Here, we explore the possibility of speeding up these interactions in 3D crystals via parametric amplification. For this purpose, we derive a general Hamiltonian for the parametric amplification of spin-motion coupling that is broadly applicable to normal modes with motion transverse to or along the spatial extent of the crystal. Unlike in lower-dimensional crystals, we find that the ability to faithfully (uniformly) amplify the spin-spin interactions in 3D crystals depends on the physical implementation of the spin-motion coupling. We consider the light-shift gate, and the so-called phase-insensitive and phase-sensitive Mølmer-Sørensen (MS) gates, and we find that only the phase-sensitive MS gate can be faithfully amplified in general 3D crystals. We discuss a situation where nonuniform amplification can be advantageous. We also reconsider the effect of counter-rotating terms on parametric amplification and find that they are not as detrimental as previous studies suggest.

Optical parametric oscillators & amplifiers↗

Entanglement Generation in Weakly Driven Arrays of Multilevel Atoms via Dipolar Interactions

We investigate the driven-dissipative dynamics of multilevel atomic arrays interacting via dipolar interactions at subwavelength spacings. Unlike two-level atoms in the weakly excited regime, multilevel atoms can become strongly entangled. Here, the entanglement manifests as the growth of spin waves in the ground-state manifold and survives after turning off the drive. We propose the 2.9 μ⁢m transition between 3 P 2 ↔ 3 D 3 in 88 Sr with 389 nm trapping light as a platform to test our predictions and explore many-body physics with light-matter interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasensitive measurement of microcantilever displacement below the shot-noise limit

The displacement of micro-electro-mechanical-systems (MEMs) cantilevers is used to measure a variety of phe- nomena in devices ranging from force microscopes for single spin detection[1] to biochemical sensors[2] to un- cooled thermal imaging systems[3]. The displacement readout is often performed optically with segmented de- tectors or interference measurements. Until recently, var- ious noise sources have limited the minimum detectable displacement in MEMs systems, but it is now possible to minimize all other sources[4] so that the noise level of the coherent light eld, called the shot noise limit (SNL), becomes the dominant source. Light sources dis- playing quantum-enhanced statistics below this limit are available[5, 6], with applications in gravitational wave astronomy[7] and bioimaging[8], but direct displacement measurements of MEMS cantilevers below the SNL have been impossible until now. Here, we demonstrate the rst direct measurement of a MEMs cantilever displace- ment with sub-SNL sensitivity, thus enabling ultratrace sensing, imaging, and microscopy applications. By com- bining multi-spatial-mode quantum light sources with a simple dierential measurement, we show that sub-SNL MEMs displacement sensitivity is highly accessible com- pared to previous eorts that measured the displacement of macroscopic mirrors with very distinct spatial struc- tures crafted with multiple optical parametric ampliers and locking loops[9]. We apply this technique to a com- mercially available microcantilever in order to detect dis- placements 60% below the SNL at frequencies where the microcantilever is shot-noise-limited. These results sup- port a new class of quantum MEMS sensor whose ulti- mate signal to noise ratio is determined by the correla- tions possible in quantum optics systems.

47 OTHER INSTRUMENTATION↗

Independent Panel Report for Technical Assessment of NASA and External Quantum Sensing Capabilities

Sensors based on quantum mechanical properties of electromagnetic radiation and matter offer unique capabilities and performance sometimes difficult to achieve using classical approaches. This report assesses the suitability of quantum sensing for current and future NASA needs, with a specific focus on NASA’s Science Mission Directorate (SMD). Measurement and sensing needs across NASA SMD are reviewed as a driver for the possible incorporation of existing quantum sensors into the NASA portfolio and the development of next-generation quantum sensors. A range of quantum sensing modalities is then described and the current state of the art for each sensor is presented. Current research and development activities on quantum sensing within NASA are compared with the range of activities ongoing throughout the broader scientific community, both within the United States and internationally. In conclusion, there is considerable advantage to be gained by NASA from quantum sensors through the growth of internal programs and collaboration with outside entities.

Quantum Sensing↗