Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Decontamination Technologies, Task 3, Urban Remediation and Response Project

In the aftermath of a Radiological Dispersal Device (RDD, also known as a dirty bomb) it will be necessary to remediate the site including building exteriors and interiors, equipment, pavement, vehicles, personal items etc. Remediation will remove or reduce radioactive contamination from the area using a combination of removing and disposing of many assets (including possible demolition of buildings), decontaminating and returning to service other assets, and fixing in place or leaving in place contamination that is deemed 'acceptable'. The later will require setting acceptable dose standards, which will require negotiation with all involved parties and a balance of risk and cost to benefit. To accomplish the first two, disposal or decontamination, a combination of technologies will be deployed that can be loosely classified as: Decontamination; Equipment removal and size reduction; and Demolition. This report will deal only with the decontamination technologies that will be used to return assets to service or to reduce waste disposal. It will not discuss demolition, size reduction or removal technologies or equipment (e.g., backhoe mounted rams, rock splitter, paving breakers and chipping hammers, etc.). As defined by the DOE (1994), decontamination is removal of radiological contamination from the surfaces of facilities and equipment. Expertise in this field comes primarily from the operation and decommissioning of DOE and commercial nuclear facilities as well as a small amount of ongoing research and development closely related to RDD decontamination. Information related to decontamination of fields, buildings, and public spaces resulting from the Goiania and Chernobyl incidents were also reviewed and provide some meaningful insight into decontamination at major urban areas. In order to proceed with decontamination, the item being processed needs to have an intrinsic value that exceeds the cost of the cleaning and justifies the exposure of any workers during the decontamination process(es). In the case of an entire building, the value may be obvious; it's costly to replace the structure. For a smaller item such as a vehicle or painting, the cost versus benefit of decontamination needs to be evaluated. This will be determined on a case by case basis and again is beyond the scope of this report, although some thoughts on decontamination of unique, personal and high value items are given. But, this is clearly an area that starting discussions and negotiations early on will greatly benefit both the economics and timeliness of the clean up. In addition, high value assets might benefit from pre-event protection such as protective coatings or HEPA filtered rooms to prevent contaminated outside air from entering the room (e.g., an art museum).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of hydraulic fluid CVCM on silver-Teflon

Changes in the solar absorptance of silver-Teflon (Ag/FEP) surfaces were measured after contamination by the outgassing products of hydraulic fluid and irradiation by solar simulators. Although radiator surfaces are selected for stability to the solar ultraviolet and particulate environment, contaminant deposition and their interaction with solar exposure can degrade their performance. The test procedure to deposit the hydraulic fluid collected volatile condensible material (CVCM), irradiate, and determine solar absorptance changes by reflectance measurements using a spectrophotometer and a solar simulator is described. The tests showed that for the estimated deposition rates on the Ag/FEP, the hydraulic fluid CVCM fraction remaining under normal conditions (above -40 C) would not degrade its performance. The residual CVCM can be easily removed from Ag/FEP by wiping with a solvent saturated flannel. The changes in solar absorptance with the CVCM film thickness and the radiation exposure duration are reported, concluding that vacuum ultraviolet radiation did not prevent easy removal of CVCM.

Muscari, J. A.↗

Headspace analysis of foams and fixatives

In the process of decontaminating and decommissioning (D&D) older nuclear facilities, special precautions must be taken with removable or airborne contamination. One possible strategy utilizes foams and fixatives to affix these loose contaminants. Many foams and fixatives are already commercially available, either generically or sold specifically for D&D. However, due to a lack of revelant testing in a radioactive environment, additional verification is needed to confirm that these products not only affix contamination to their surfaces, but also will function in a D&D environment. Several significant safety factors, including flammability and worker safety, can be analyzed through the process of headspace analysis, a technique that analyzes the off gas formed before or during the curing process of the foam/fixative, usually using gas chromatography-mass spectrometry (GC-MS). This process focuses on the volatile components of a chemical, which move freely between the solid/liquid form within the sample and the gaseous form in the area above the sample (the headspace). Between possibly hot conditions in a D&D situation and heat created in a foaming reaction, the volatility of many chemicals can change, and thus different gasses can be released at different times throughout the reaction. This project focused on analysis of volatile chemicals involved in the process of using foams and fixatives to identify any potential hazardous or flammable compounds.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sequestration of Sr-90 Subsurface Contamination in the Hanford 100-N Area by Surface Infiltration of a Ca-Citrate-Phosphate Solution

The objective of this project is to develop a method to emplace apatite precipitate in the 100N vadose zone, which results in sorption and ultimately incorporation of Sr-90 into the apatite structure. The Ca-citrate-PO4 solution can be infiltrated into unsaturated sediments to result in apatite precipitate to provide effective treatment of Sr-90 contamination. Microbial redistribution during solution infiltration and a high rate of citrate biodegradation for river water microbes (water used for solution infiltration) results in a relatively even spatial distribution of the citrate biodegradation rate and ultimately apatite precipitate in the sediment. Manipulation of the Ca-citrate-PO4 solution infiltration strategy can be used to result in apatite precipitate in the lower half of the vadose zone (where most of the Sr-90 is located) and within low-K layers (which are hypothesized to have higher Sr-90 concentrations). The most effective infiltration strategy to precipitate apatite at depth (and with sufficient lateral spread) was to infiltrate a high concentration solution (6 mM Ca, 15 mM citrate, 60 mM PO4) at a rapid rate (near ponded conditions), followed by rapid, then slow water infiltration. Repeated infiltration events, with sufficient time between events to allow water drainage in the sediment profile can be used to buildup the mass of apatite precipitate at greater depth. Low-K heterogeneities were effectively treated, as the higher residual water content maintained in these zones resulted in higher apatite precipitate concentration. High-K zones did not receive sufficient treatment by infiltration, although an alternative strategy of air/surfactant (foam) was demonstrated effective for targeting high-K zones. The flow rate manipulation used in this study to treat specific depths and heterogeneities are not as easy to implement at field scale due to the lack of characterization of heterogeneities and difficulty tracking the wetting front over a large subsurface area. However, the use of real-time surface and cross-borehole geophysics can be used to track the infiltrating Ca-citrate-PO4 front so some adjustments can be made in the infiltration rate to precipitate apatite in desired zones. In addition, the reactive transport code used in this study with field scale physical parameters for sediments can be used to evaluate infiltration strategies along with preliminary water infiltration tests at field scale.

58 GEOSCIENCES↗

Innovative Data Management System in Support of Remedial Actions for Legacy Radioactive Contamination - 17280

The Port Hope Area Initiative (PHAI) is a project mandated and funded by the Government of Canada to remove contamination from properties with legacy low-level radioactive waste (LLRW) contamination arising from a crown-owned radium and, later, uranium refinery in the Town of Port Hope, Ontario. From 1976 to 1981, a community clean-up project was undertaken, with the specific purpose to decrease the level of historic LLRW contamination within Port Hope. Since then, residual LLRW has been managed by the Low Level Radioactive Waste Management Office (LLRWMO) (and its predecessors). The PHAI and the Port Hope Project (PHP) were initiated in 2001 with a formal agreement between affected municipalities and the federal government to develop a safe, long-term management solution for the historic LLRW remaining within Port Hope. An important activity of the PHP is the survey of about 4,800 'small scale sites' (SSS) throughout the community to confirm the presence or absence of LLRW. This involves surveys of properties based on the measurement of exterior gamma, contaminated objects and surfaces, soil concentrations and indoor radon and classification to Port Hope project specific criteria. A very large amount of information is involved in the project including; scheduling individual field visits to the properties, capture of field data and comments, laboratory sample tracking, QA/QC, report generation and internal and client project reporting at regular schedules. Field data collection of exterior gamma radiation surveys includes direct (real time) and interactive loading of data into the Information Management (IM) system to support initial QA/QC and reporting back to the field on radiation levels. Screening soil measurements including X-ray fluorescence (XRF) and gamma radiation are collected from all 20 cm increments in each borehole in addition to down-hole gamma radiation measurements and logging of soil characteristics which are used in documentation and interpretation of the property condition. The IM system outlined in this paper was developed to respond to the requirements for radiological surveys in Port Hope. The IM system continues to evolve as a part of continuing review and improvement. The IM system incorporates Web-enabled field tools and cloud hosted data and applications, provides increased field efficiency, timeliness in reporting, real time QA/QC analysis, and consistency in tracking project advances and changes made to the data for decision-making and reporting on an ongoing basis. Examples of specific applications are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological results for samples collected on paired glass- and cellulose-fiber filters at the Sandia complex, Tonopah Test Range, Nevada

Airborne particulates are collected at U.S. Department of Energy sites that exhibit radiological contamination on the soil surface to help assess the potential for wind to transport radionuclides from the contamination sites. Collecting these samples was originally accomplished by drawing air through a cellulose-fiber filter. These filters were replaced with glass-fiber filters in March 2011. Airborne particulates were collected side by side on the two filter materials between May 2013 and May 2014. Comparisons of the sample mass and the radioactivity determinations for the side-by-side samples were undertaken to determine if the change in the filter medium produced significant results. The differences in the results obtained using the two filter types were assessed visually by evaluating the time series and correlation plots and statistically by conducting a nonparametric matched-pair sign test. Generally, the glass-fiber filters collect larger samples of particulates and produce higher radioactivity values for the gross alpha, gross beta, and gamma spectroscopy analyses. However, the correlation between the radioanalytical results for the glass-fiber filters and the cellulose-fiber filters was not strong enough to generate a linear regression function to estimate the glass-fiber filter sample results from the cellulose-fiber filter sample results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tin removal by an annular surface wave plasma antenna in an extreme ultraviolet lithography source

Tin contamination of the collector mirror surface remains one of the crucial issues of EUV (Extreme Ultraviolet) sources, directly impacting the availability of the tool. Hydrogen plasma-based tin removal processes employ hydrogen radicals and ions to interact with tin deposits to form gaseous tin hydride (SnH 4 ), which can be removed through pumping. An annular surface wave plasma (SWP) source developed at the University of Illinois—Urbana Champaign is integrated into the cone and perimeter of the collection mirror for in situ tin removal. The SWP is characterized by high ion and radical densities, low electron temperature, and local generation where etching is needed. This method has the potential to significantly reduce downtime and increase mirror lifetime. Radical probe measurements show hydrogen radical densities in the order of 10 19 m -3 , while Langmuir probe measurements show electron temperatures of up to 6 eV and plasma densities on the order of 10 17–18 m -3 . The generated ions are essential to the tin cleaning and have sufficiently low energy to cause no damage to the collector capping layer. Tin etch rates of up to 270 nm/min were observed in a variety of experimental conditions, including various powers, pressures, flowrates, and temperatures. In conclusion, the high etch rates demonstrated in this study exceed the expected contamination rate of the EUV source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seasonal mixing from intermittent flow drives concentration-discharge behaviour in a stream affected by coal mine drainage

Abandoned mining operations continue to severely degrade many ecosystems worldwide by releasing acidic water and/or heavy metals into surface and groundwater. Contaminant concentrations in affected streams vary with discharge in patterns that reflect both geochemical reactions and variable mixing of contaminated and non-contaminated waters. However, controls on concentration-discharge (C-Q) patterns remain unclear, particularly for constituents that experience changing solubility across redox and pH gradients. Understanding the C-Q behaviour of contaminants aids in predicting both downstream transport and effects on aquatic life under variable flow. Here, we examined the C-Q behaviours of non-reactive (Na, K, Ca, Mg, Cl - ) and reactive (Fe, Mn, Al, H + , SO 4 2- ) solutes in a stream contaminated with acid mine drainage in northeastern Ohio, USA. Concentration-discharge patterns at the watershed outlet primarily reflected mixing of contaminated baseflow with intermittent inputs of high pH water draining from a passive limestone treatment system into the stream. The treatment system acted as an ephemeral tributary that mitigated contamination in the stream by diluting solutes, raising pH, and driving metal precipitation, but only when flow was present during wet seasons. Consequently, AMD-derived reactive solutes (H + , Fe, Mn, Al) decreased with increasing stream discharge while relatively conservative solutes (e.g., Ca, Mg, K, Na) decreased only slightly or were chemostatic. This study highlights both the unique C-Q patterns of reactive solutes when compared to those of non-reactive solutes and the potential for intermittent streams to control C-Q behaviour in headwater catchments.

58 GEOSCIENCES↗

Photogalvanic Etching of n -GaN for Three-Dimensional Electronics

Etching in wide-bandgap semiconductors such as GaN aids applications including transistors, sensors, and radioisotope batteries. Plasma-based etching can induce surface damage and contamination that is detrimental to device performance. Here, the present a photoelectrochemical approach to etching n -type GaN ( n -GaN) that is low-cost, simple, and environmentally benign compared to plasma approaches, with the potential for highly anisotropic etching that avoids material damage. n -GaN was etched in a dilute KOH solution with K 2 S 2 O 8 oxidizer, ultraviolet (UV) irradiation, and a catalytic metal mask which served as both photomask and counter electrode. Relatively smooth, highly anisotropic, non-defect-selective etching was achieved at rates in excess of 200 nm/min when etching at 65°C. The obstacle of bath acidification was circumvented using the addition of buffering salts to the etchant bath, substantially extending the etchant bath lifetime and etching depth achievable in a single, uninterrupted etch. These results represent a major step toward a scalable, device-ready electrochemical etch for vertical GaN structures and devices.

36 MATERIALS SCIENCE↗

PdAgAu alloy with high resistance to corrosion by H 2 S

PdAgAu alloy films were prepared on porous stainless steel supports by sequential electroless deposition. Two specific compositions, Pd 83 Ag 2 Au 15 and Pd 74 Ag 14 Au 12 , were studied for their sulfur tolerance. The alloys and a reference Pd foil were exposed to 1000 H 2 S /H 2 at 623 K for periods of 3 and 30 hours. The microstructure, morphology and bulk composition of both nonexposed and H 2 S-exposed samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). XRD and SEM analysis revealed time-dependent growth of a bulk Pd{sub 4}S phase on the Pd foil during H 2 S exposure. In contrast, the PdAgAu ternary alloys displayed the same FCC structure before and after H 2 S exposure. In agreement with the XRD and SEM results, sulfur was not detected in the bulk of either ternary alloy samples by EDS, even after 30 hours of H 2 S exposure. X-ray photoelectron spectroscopy (XPS) depth profiles were acquired for both PdAgAu alloys after 3 and 30 hours of exposure to characterize sulfur contamination near their surfaces. Very low S 2p and S 2s XPS signals were observed at the top-surfaces of the PdAgAu alloys, and those signals disappeared before the etch depth reached ~ 10 nm, even for samples exposed to H 2 S for 30 hours. The depth profile analyses also revealed silver and gold segregation to the surface of the alloys; preferential location of Au on the alloys surface may be related to their resistance to bulk sulfide formation. In preliminary tests, a PdAgAu alloy membrane displayed higher initial H{sub 2} permeability than a similarly prepared pure Pd sample and, consistent with resistance to bulk sulfide formation, lower permeability loss in H 2 S than pure Pd.

36 MATERIALS SCIENCE↗

First-principles study of sulfur passivation of GaP(001) surfaces at one-monolayer coverage

Using first-principles total energy method, we have studied the structural and electronic properties of Ga- and P-terminated GaP(001)(1×2) surfaces adsorbed with one monolayer of sulfur. It was found that the sulfur atoms prefer to occupy bridge sites and the periodicity becomes (1 × 1) on both Ga- and Pterminated surfaces. The S–Ga bond was confirmed to be stronger than the S–P bond. The electronic analysis showed that the surface state within the energy gap on the Ga-terminated GaP surface was noticeably reduced by the sulfur adsorption, while such reduction does not occur on the P-terminated surface due to the S–P antibonding state. The nearly filled S dangling bonds on the Ga-terminated surface make this surface resistant to contamination.

36 MATERIALS SCIENCE↗

Contribution of Microorganisms with the Clade II Nitrous Oxide Reductase to Suppression of Surface Emissions of Nitrous Oxide

The sources and sinks of nitrous oxide, as control emissions to the atmosphere, are generally poorly constrained for most environmental systems. Initial depth-resolved analysis of nitrous oxide flux from observation wells and the proximal surface within a nitrate contaminated aquifer system revealed high subsurface production but little escape from the surface. Further, to better understand the environmental controls of production and emission at this site, we used a combination of isotopic, geochemical, and molecular analyses to show that chemodenitrification and bacterial denitrification are major sources of nitrous oxide in this subsurface, where low DO, low pH, and high nitrate are correlated with significant nitrous oxide production. Depth-resolved metagenomes showed that consumption of nitrous oxide near the surface was correlated with an enrichment of Clade II nitrous oxide reducers, consistent with a growing appreciation of their importance in controlling release of nitrous oxide to the atmosphere. Our work also provides evidence for the reduction of nitrous oxide at a pH of 4, well below the generally accepted limit of pH 5.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of a Nuclear Accident: Fission and Activation Product Releases from the Fukushima Daiichi Nuclear Facility as Remote Indicators of Source Identification, Extent of Release, and State of Damaged Spent Nuclear Fuel

Measurements of several radionuclides within environmental samples taken from the Fukushima Daiichi nuclear facility and reported on the Tokyo Electric Power Company website following the recent tsunami-initiated catastrophe were evaluated for the purpose of identifying the source term, reconstructing the release mechanisms, and estimating the extent of the release. 136Cs/137Cs and 134Cs/137Cs ratios identified Units 1-3 as the major source of radioactive contamination to the surface soil close to the facility. A trend was observed between the fraction of the total core inventory released for a number of fission product isotopes and their corresponding Gibbs Free Energy of formation for the primary oxide form of the isotope, suggesting that release was dictated primarily by chemical volatility driven by temperature and reduction potential within the primary containment vessels of the vented reactors. The absence of any major fractionation beyond volatilization suggested all coolant had evaporated by the time of venting. High estimates for the fraction of the total inventory released of more volatile species (Te, Cs, I) indicated the damage to fuel bundles was likely extensive, minimizing any potential containment due to physical migration of these species through the fuel matrix and across the cladding wall. 238Pu/239,240Pu ratios close-in and at 30 km from the facility indicated that the damaged reactors were the major contributor of Pu to surface soil at the source but that this contribution likely decreased rapidly with distance from the facility. The fraction of the total Pu inventory released to the environment from venting units 1 and 3 was estimated to be ~0.003% based upon Pu/Cs isotope ratios relative to the within-reactor modeled inventory prior to venting and was consistent with an independent model evaluation that considered chemical volatility based upon measured fission product release trends. Significant volatile radionuclides within the spent fuel at the time of venting but not as yet observed and reported within environmental samples are suggested as potential analytes of concern for future environmental surveys around the site.

Schwantes, Jon M↗

Interplay of the forces governing steroid hormone micropollutant adsorption in vertically-aligned carbon nanotube membrane nanopores

Vertically-aligned carbon nanotube (VaCNT) membranes allow water to conduct rapidly at low pressures and open up the possibility for water purification and desalination, although the ultralow viscous stress in hydrophobic and low-tortuosity nanopores prevents surface interactions with contaminants. In this experimental investigation, steroid hormone micropollutant adsorption by VaCNT membranes is quantified and explained via the interplay of the hydrodynamic drag and friction forces acting on the hormone, and the adhesive and repulsive forces between the hormone and the inner carbon nanotube wall. It is concluded that a drag force above 2.2 × 10 —3 pN overcomes the friction force resulting in insignificant adsorption, whereas lowering the drag force from 2.2 × 10 —3 to 4.3 × 10 —4 pN increases the adsorbed mass of hormones from zero to 0.4 ng cm —2 . At a low drag force of 1.6 × 10 —3 pN, the adsorbed mass of four hormones is correlated with the hormone–wall adhesive (van der Waals) force. These findings explain micropollutant adsorption in nanopores via the forces acting on the micropollutant along and perpendicular to the flow, which can be exploited for selectivity.

36 MATERIALS SCIENCE↗

The possibly important role played by Ga{sub 2}O{sub 3} during the activation of GaN photocathode

Three different chemical solutions are used to remove the possible contamination on GaN surface, while Ga{sub 2}O{sub 3} is still found at the surface. After thermal annealing at 710 °C in the ultrahigh vacuum (UHV) chamber and activated with Cs/O, all the GaN samples are successfully activated to the effective negative electron affinity (NEA) photocathodes. Among all samples, the GaN sample with the highest content of Ga{sub 2}O{sub 3} after chemical cleaning obtains the highest quantum efficiency. By analyzing the property of Ga{sub 2}O{sub 3}, the surface processing results, and electron affinity variations during Cs and Cs/O{sub 2} deposition on GaN of other groups, it is suggested that before the adsorption of Cs, Ga{sub 2}O{sub 3} is not completely removed from GaN surface in our samples, which will combine with Cs and lead to a large decrease in electron affinity. Furthermore, the effective NEA is formed for GaN photocathode, along with the surface downward band bending. Based on this assumption, a new dipole model Ga{sub 2}O{sub 3}-Cs is suggested, and the experimental effects are explained and discussed.

36 MATERIALS SCIENCE↗

Crossflow membrane filtration system for operando fouling characterization using transmission x-ray scattering

Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.

36 MATERIALS SCIENCE↗