Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

SU-E-T-154: Establishment and Implement of 3D Image Guided Brachytherapy Planning System

Purpose: Cannot observe the dose intuitionally is a limitation of the existing 2D pre-implantation dose planning. Meanwhile, a navigation module is essential to improve the accuracy and efficiency of the implantation. Hence a 3D Image Guided Brachytherapy Planning System conducting dose planning and intra-operative navigation based on 3D multi-organs reconstruction is developed. Methods: Multi-organs including the tumor are reconstructed in one sweep of all the segmented images using the multiorgans reconstruction method. The reconstructed organs group establishs a three-dimensional visualized operative environment. The 3D dose maps of the three-dimentional conformal localized dose planning are calculated with Monte Carlo method while the corresponding isodose lines and isodose surfaces are displayed in a stereo view. The real-time intra-operative navigation is based on an electromagnetic tracking system (ETS) and the fusion between MRI and ultrasound images. Applying Least Square Method, the coordinate registration between 3D models and patient is realized by the ETS which is calibrated by a laser tracker. The system is validated by working on eight patients with prostate cancer. The navigation has passed the precision measurement in the laboratory. Results: The traditional marching cubes (MC) method reconstructs one organ at one time and assembles them together. Compared to MC, presented multi-organs reconstruction method has superiorities in reserving the integrality and connectivity of reconstructed organs. The 3D conformal localized dose planning, realizing the 'exfoliation display' of different isodose surfaces, helps make sure the dose distribution has encompassed the nidus and avoid the injury of healthy tissues. During the navigation, surgeons could observe the coordinate of instruments real-timely employing the ETS. After the calibration, accuracy error of the needle position is less than 2.5mm according to the experiments. Conclusion: The speed and quality of 3D reconstruction, the efficiency in dose planning and accuracy in navigation all can be improved simultaneously.

60 APPLIED LIFE SCIENCES↗

Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging

Purpose: The authors report on measurements of light output and spatial resolution of microcolumnar CsI:Tl scintillator detectors for x-ray imaging. In addition, the authors discuss the results of simulations aimed at analyzing the results of synchrotron and sealed-source exposures with respect to the contributions of light transport to the total light output. Methods: The authors measured light output from a 490-μm CsI:Tl scintillator screen using two setups. First, the authors used a photomultiplier tube (PMT) to measure the response of the scintillator to sealed-source exposures. Second, the authors performed imaging experiments with a 27-keV monoenergetic synchrotron beam and a slit to calculate the total signal generated in terms of optical photons per keV. The results of both methods are compared to simulations obtained with hybridMANTIS, a coupled x-ray, electron, and optical photon Monte Carlo transport package. The authors report line response (LR) and light output for a range of linear absorption coefficients and describe a model that fits at the same time the light output and the blur measurements. Comparing the experimental results with the simulations, the authors obtained an estimate of the absorption coefficient for the model that provides good agreement with the experimentally measured LR. Finally, the authors report light output simulation results and their dependence on scintillator thickness and reflectivity of the backing surface. Results: The slit images from the synchrotron were analyzed to obtain a total light output of 48 keV{sup −1} while measurements using the fast PMT instrument setup and sealed-sources reported a light output of 28 keV{sup −1}. The authors attribute the difference in light output estimates between the two methods to the difference in time constants between the camera and PMT measurements. Simulation structures were designed to match the light output measured with the camera while providing good agreement with the measured LR resulting in a bulk absorption coefficient of 5 × 10{sup −5} μm{sup −1}. Conclusions: The combination of experimental measurements for microcolumnar CsI:Tl scintillators using sealed-sources and synchrotron exposures with results obtained via simulation suggests that the time course of the emission might play a role in experimental estimates. The procedure yielded an experimentally derived linear absorption coefficient for microcolumnar Cs:Tl of 5 × 10{sup −5} μm{sup −1}. To the author’s knowledge, this is the first time this parameter has been validated against experimental observations. The measurements also offer insight into the relative role of optical transport on the effective optical yield of the scintillator with microcolumnar structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Electric-field enhancement caused by subwavelength-sized particles located on the surface of multilayer dielectric mirrors

A laser pulse impinging on the surface of an optical component can interact with particles, such as contamination debris, to produce a scattered electric field, which, either by itself or combined with the incident laser field, coherently can significantly increase the local field intensity. This effect can be of critical importance as it can reduce the laser-induced–damage threshold of the affected component. In this work, we use a field-propagation code to improve understanding regarding the factors that determine the magnitude and location of the electric-field enhancement for the case of subwavelength-sized particles located on the surface of multilayer dielectric mirrors.

47 OTHER INSTRUMENTATION↗

T-TY Tank Farm Interim Surface Barrier Demonstration—Vadose Zone Monitoring Plan

The Hanford Site has 149 underground single-shell tanks that store hazardous radioactive waste. Many of these tanks and their associated infrastructure (e.g., pipelines, diversion boxes) have leaked. Some of the leaked waste has entered the groundwater. The largest known leak occurred from the T-106 Tank of the 241-T Tank Farm in 1973. Five tanks are assumed to have leaked in the TY Farm. Many of the contaminants from those leaks still reside within the vadose zone within the T and TY Tank Farms. The Department of Energy’s Office of River Protection seeks to minimize the movement of these contaminant plumes by placing interim barriers on the ground surface. Such barriers are expected to prevent infiltrating water from reaching the plumes and moving them further. The soil water regime is monitored to determine the effectiveness of the interim surface barriers. Soil-water content and water pressure are monitored using off-the-shelf equipment that can be installed by the hydraulic hammer technique. Four instrument nests were installed in the T Farm in fiscal year (FY) 2006 and FY2007; two nests were installed in the TY Farm in FY2010. Each instrument nest contains a neutron probe access tube, a capacitance probe, and four heat-dissipation units. A meteorological station has been installed at the north side of the fence of the T Farm. This document summarizes the monitoring methods, the instrument calibration and installation, and the vadose zone monitoring plan for interim barriers in T farm and TY Farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nano-Filament Field Emission Cathode Development Final Report CRADA No. TSB-0731-93

At the time the CRADA was established, Silicon Video Corporation, of Cupertino, CA was a one-year-old rapidly growing start-up company. SVC was developing flat panel displays (FPDs) to replace Cathode Ray Terminals (CRTs) for personal computers, work stations and televisions. They planned to base their products on low cost and energy efficient field emission technology. It was universally recognized that the display was both the dominant cost item and differentiating feature of many products such as laptop computers and hand-held electronics and that control of the display technology through U.S. sources was essential to success in these markets. The purpose of this CRADA project was to determine if electrochemical planarization would be a viable, inexpensive alternative to current optical polishing techniques for planarizing the surface of a ceramic backplate of a thin film display.

42 ENGINEERING↗

Report on Qiagen Columns with Precipitation versus Packed Bed Technology for Trace Amounts of DNA

The assured limit of detection (LOD), where 100% of the PCR assays are successful, for the Qiagen spin column is dramatically improved when combined with an ethanol precipitation step of the eluted sample. A detailed SOP for the ethanol precipitation was delivered as a separate report. A key finding in the precipitation work was to incubate the ethanol precipitation at -20{sup o}C overnight when concentrating low copy number samples. Combining this modified ethanol precipitation with the Qiagen spin columns, the limit of assured detection was improved by 1-2 orders of magnitude, for the aliquot and assay variables used. The lower limit of detection (defined as when at least 1 assay of 1 aliquot was positive) was only improved by approximately 1 order of magnitude. The packed bed process has the potential of a 20-fold improvement in the limit of detection compared to Qiagen plus precipitation, based on a mass balance analysis for the entire DNA concentration and purification processes. Figure ES1 shows a mass balance for all the DNA processing steps. The packed bed process minimizes losses from elution, precipitation, and pipetting (aliquoting and transferring). Figure ES1 assumes that 100 copies of DNA serve as the input sample. Efficiencies for each step have been estimated based on our experiences or a worst case scenario (for example, a 50% loss was assumed for pipetting). Table ES1 summarizes the number of copies that are the input template for PCR assuming 100 copies of DNA are processed through the three options detailed in Figure ES1.Theoretically a 20-fold increase in the number of starting copies in the PCR reaction is gained when the DNA is concentrated, purified and then amplified directly on the surface of the beads in the packed bed.

47 OTHER INSTRUMENTATION↗

SPRUCE: LAI Data from SPRUCE Experimental Plots, 2017-2018

This data set provides leaf area index (LAI) data collected across vegetation community plots within the 10 chambered treatment plots (6, 19, 11, 20, 4, 13, 8, 16, 10, 17) and 3 unchambered ambient plots (7, 14, 21) of the SPRUCE experiment project in 2017 and 2018. The vegetation community plots were established in 2014 and designated to be undisturbed and reserved for long-term sampling. LAI measurements were collected using a LICOR-LAI 2200 instrument over a standard 1x2 meter rectangular sampling frame with 50 20x20 cm grid cells. LAI was measured above the canopy and below the vegetation at the surface of the peat (living sphagnum) in the same grid cells each year.

54 ENVIRONMENTAL SCIENCES↗

Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

Scanning transmission x-ray microscopy (STXM) combines x-ray microscopy and near edge x-ray absorption fine structure spectroscopy (NEXAFS). This combination provides spatially resolved bonding and oxidation state information. While there are reviews relevant to STXM/NEXAFS applications in other environmental fields (and magnetic materials) this chapter focuses on atmospheric aerosols. It provides an introduction to this technique in a manner approachable to non-experts. It begins with relevant background information on synchrotron radiation sources and a description of NEXAFS spectroscopy. The bulk of the chapter provides a survey of STXM/NEXAFS aerosol studies and is organized according to the type of aerosol investigated. The purpose is to illustrate the current range and recent growth of scientific investigations employing STXM-NEXAFS to probe atmospheric aerosol morphology, surface coatings, mixing states, and atmospheric processing.

47 OTHER INSTRUMENTATION↗

Multipoint photonic doppler velocimetry using optical lens elements

A probe including a fisheye lens is disclosed to measure the velocity distribution of a moving surface along many lines of sight. Laser light, directed to the surface and then reflected back from the surface, is Doppler shifted by the moving surface, collected into fisheye lens, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to an index-matching lens and eventually to a fisheye lens. The fiber array flat polished and coupled to the index-matching lens using index-matching gel. Numerous fibers in a fiber array project numerous rays through the fisheye lens which in turn project many measurement points at numerous different locations to establish surface coverage over a hemispherical shape with very little crosstalk.

47 OTHER INSTRUMENTATION↗

Simultaneous detection of surface coverage and structure of krypton films on gold by helium atom diffraction and quartz crystal microbalance techniques

We describe a quartz crystal microbalance setup that can be operated at low temperatures in ultra high vacuum with gold electrode surfaces acting as substrate surface for helium diffraction measurements. By simultaneous measurement of helium specular reflection intensity from the electrode surface and resonance frequency shift of the crystal during film adsorption, helium diffraction data can be correlated to film thickness. In addition, effects of interfacial viscosity on the helium diffraction pattern could be observed. To this end, first, flat gold films on AT cut quartz crystals were prepared which yield high enough helium specular reflection intensity. Then the crystals were mounted in the helium diffractometer sample holder and driven by means of a frequency modulation driving setup. Different crystal geometries were tested to obtain the best quality factor and preliminary measurements were performed on Kr films on gold surfaces. While the crystal structure and coverage of krypton films as a function of substrate temperature could successfully be determined, no depinning effects could be observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T-TY Tank Farm Interim Surface Barrier Demonstration - Vadose Zone Monitoring FY10 Report

The U.S. Department of Energy’s Office of River Protection has constructed interim surface barriers over a portion of the T and TY tank farms as part of the Interim Surface Barrier Demonstration Project. The interim surface barriers (hereafter referred to as the surface barriers or barriers) are designed to minimize the infiltration of precipitation into the soil zones containing radioactive contaminants and minimize the movement of the contaminants. As part of the demonstration effort, vadose zone moisture is being monitored to assess the effectiveness of the barriers at reducing soil moisture. Solar-powered systems were installed to continuously monitor soil water conditions at four locations in the T (i.e., instrument Nests TA, TB, TC, and TD) and the TY (i.e., instrument Nests TYA and TYB) Farms beneath the barriers and outside the barrier footprint as well as site meteorological conditions. Nests TA and TYA are placed in the area outside the barrier footprint and serve as controls, providing subsurface conditions outside the influence of the surface barriers. Nest TB provides subsurface measurements to assess surface-barrier edge effects. Nests TC, TD, and TYB are used to assess changes in soil-moisture conditions beneath the interim surface barriers.

54 ENVIRONMENTAL SCIENCES↗

T Tank Farm Interim Surface Barrier Demonstration - Vadose Zone Monitoring FY08 Report

DOE’s Office of River Protection constructed a temporary surface barrier over a portion of the T Tank Farm as part of the T Farm Interim Surface Barrier Demonstration Project. The surface barrier is designed to minimize the infiltration of precipitation into the contaminated soil zone created by the Tank T-106 leak and minimize movement of the contamination. As part of the demonstration effort, vadose zone moisture is being monitored to assess the effectiveness of the barrier at reducing soil moisture. A solar-powered system was installed to continuously monitor soil water conditions at four locations (i.e., instrument Nests A, B, C, and D) beneath the barrier and outside the barrier footprint as well as site meteorological conditions. Nest A is placed in the area outside the barrier footprint and serves as a control, providing subsurface conditions outside the influence of the surface barrier. Nest B provides subsurface measurements to assess surface-barrier edge effects. Nests C and D are used to assess changes in soil-moisture conditions beneath the interim surface barrier.

54 ENVIRONMENTAL SCIENCES↗

Fabrication of sharp tungsten-coated tip for atomic force microscopy by ion-beam sputter deposition

Tungsten (W) is significantly suitable as a tip material for atomic force microscopy (AFM) because its high mechanical stiffness enables the stable detection of tip-sample interaction forces. We have developed W sputter-coating equipment to compensate the drawbacks of conventional Si cantilever tips used in AFM measurements. By employing an ion gun commonly used for sputter cleaning of a cantilever tip, the equipment is capable of depositing conductive W films in the preparation chamber of a general ultrahigh vacuum (UHV)-AFM system without the need for an additional chamber or transfer system. This enables W coating of a cantilever tip immediately after sputter cleaning of the tip apex and just before the use in AFM observations. The W film consists of grain structures, which prevent tip dulling and provide sharpness (<3 nm in radius of curvature at the apex) comparable to that of the original Si tip apex. We demonstrate that in non-contact (NC)-AFM measurement, a W-coated Si tip can clearly resolve the atomic structures of a Ge(001) surface without any artifacts, indicating that, as a force sensor, the fabricated W-coated Si tip is superior to a bare Si tip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

Purpose: Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method could be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. Methods: The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators' internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 x 1.5 and 2.0 x 2.0 mm{sup 2} cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. Results: All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. Conclusions: The internal radioactivity of LYSO scintillators can be used to accurately measure DOI function in PET detectors, regardless of scintillator geometry or surface finish. Because an external radiation source is not needed, this method of DOI function measurement can be practically applied to individual PET detectors as well as assembled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

InSAR Monitoring to Evaluate Surface Changes with CO 2 Storage in a Depleted Oil Field in Northern Michigan

Battelle evaluated the potential use of Interferometric Synthetic Aperture Radar (InSAR) for monitoring the outcome of injected CO 2 at the Dover 33 reef near Gaylord, Michigan. InSAR is a satellite-based technology that provides high-precision information on the movement of ground surface in areas with high radar coherence (e.g., roads, buildings, bare soils). Depending on the setting, this technique may provide a useful tool for characterizing reservoirs by measuring surface deformations from activities such as brine water disposal; production of water, oil, and/or gas; and carbon capture, utilization, and storage (CCUS).

47 OTHER INSTRUMENTATION↗

X-ray diffraction effect from surface acoustic waves traveling on a deposited multilayer

We investigate the x-ray diffraction effects from surface acoustic waves (SAW) traveling along a multilayer. The diffraction intensity distribution depends on the incidence angle and the multilayer SAW (MLSAW) amplitude. Particularly, a small departure deviating from the Bragg incidence angle at a certain amplitude will produce a larger variation of the intensity distribution. This shows that the diffraction intensity from MLSAW has an extremely high sensitivity to the Bragg incidence angle, which is different from a SAW traveling along a solid surface without deposited layers. By carefully analyzing the relationship between the intensity distribution I and the incidence angle {theta}, the corresponding analytic expression of the intensity distribution is theoretically derived. Our theoretical prediction is in great agreement with the experimental results previously obtained. A theoretical model that can be applied to study the x-ray diffraction effect from MLSAW is developed. The extremely high sensitivity to the Bragg angle will help us in acousto-optic instrument research with MLSAW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗