Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

General description of electromagnetic radiation processes based on instantaneous charge acceleration in ''endpoints''

We present a methodology for calculating the electromagnetic radiation from accelerated charged particles. Our formulation - the 'endpoint formulation' - combines numerous results developed in the literature in relation to radiation arising from particle acceleration using a complete, and completely general, treatment. We do this by describing particle motion via a series of discrete, instantaneous acceleration events, or 'endpoints', with each such event being treated as a source of emission. This method implicitly allows for particle creation and destruction, and is suited to direct numerical implementation in either the time or frequency domains. In this paper we demonstrate the complete generality of our method for calculating the radiated field from charged particle acceleration, and show how it reduces to the classical named radiation processes such as synchrotron, Tamm's description of Vavilov-Cherenkov, and transition radiation under appropriate limits. Using this formulation, we are immediately able to answer outstanding questions regarding the phenomenology of radio emission from ultra-high-energy particle interactions in both the earth's atmosphere and the moon. In particular, our formulation makes it apparent that the dominant emission component of the Askaryan effect (coherent radio-wave radiation from high-energy particle cascades in dense media) comes from coherent 'bremsstrahlung' from particle acceleration, rather than coherent Vavilov-Cherenkov radiation.

43 PARTICLE ACCELERATORS↗

Multilevel Monte Carlo for two phase flow and Buckley–Leverett transport in random heterogeneous porous media

Monte Carlo (MC) is a well known method for quantifying uncertainty arising for example in subsurface flow problems. Although robust and easy to implement, MC suffers from slow convergence. Extending MC by means of multigrid techniques yields the multilevel Monte Carlo (MLMC) method. MLMC has proven to greatly accelerate MC for several applications including stochastic ordinary differential equations in finance, elliptic stochastic partial differential equations and also hyperbolic problems. In this study, MLMC is combined with a streamline-based solver to assess uncertain two phase flow and Buckley–Leverett transport in random heterogeneous porous media. The performance of MLMC is compared to MC for a two dimensional reservoir with a multi-point Gaussian logarithmic permeability field. The influence of the variance and the correlation length of the logarithmic permeability on the MLMC performance is studied.

97 MATHEMATICS AND COMPUTING↗

Harmonic analysis of discrete tracers of large-scale structure

It is commonplace in cosmology to analyze fields projected onto the celestial sphere, and in particular density fields that are defined by a set of points e.g. galaxies. When performing an harmonic-space analysis of such data (e.g. an angular power spectrum) using a pixelized map one has to deal with aliasing of small-scale power and pixel window functions. We compare and contrast the approaches to this problem taken in the cosmic microwave background and large-scale structure communities, and advocate for a direct approach that avoids pixelization. We describe a method for performing a pseudo-spectrum analysis of a galaxy data set and show that it can be implemented efficiently using well-known algorithms for special functions that are suited to acceleration by graphics processing units (GPUs). The method returns the same spectra as the more traditional map-based approach if in the latter the number of pixels is taken to be sufficiently large and the mask is well sampled. The method is readily generalizable to cross-spectra and higher-order functions. It also provides a convenient route for distributing the information in a galaxy catalog directly in harmonic space, as a complement to releasing the configuration-space positions and weights, and a route to spectral apodization. Finally, we make public a code enabling the application of our method to existing and upcoming datasets.

79 ASTRONOMY AND ASTROPHYSICS↗

P2 - The weak charge of the proton

The goal of the P2 project is a new high precision determination of the electroweak mixing angle θ{sub W}. The project has been approved in January 2012 and the experiment will be carried out at the upcoming MESA accelerator facility in Mainz. The experimental method is a measurement of the proton weak charge Q{sub W}(p) through the parity violating asymmetry in the elastic electron-proton scattering at low values of Q{sup 2} ∼ 0.003 GeV{sup 2}. We have estimated an achievable fractional precision of 0.15% in the determination of sin{sup 2}(θ{sub W}), which corresponds to an uncertainty of 2.1% for Q{sup W}(p). In this article, we discuss the achievable precision within Project P2 and present first results of conceptual studies for the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time evolution of the luminosity of colliding heavy-ion beams in BNL Relativistic Heavy Ion Collider and CERN Large Hadron Collider

We have studied the time evolution of the heavy ion luminosity and bunch intensities in the Relativistic Heavy Ion Collider (RHIC), at BNL, and in the Large Hadron Collider (LHC), at CERN. First, we present measurements from a large number of RHIC stores (from Run 7), colliding 100 GeV/nucleon {sup 197}Au{sup 79}+ beams without stochastic cooling. These are compared with two different calculation methods. The first is a simulation based on multi-particle tracking taking into account collisions, intrabeam scattering, radiation damping, and synchrotron and betatron motion. In the second, faster, method, a system of ordinary differential equations with terms describing the corresponding effects on emittances and bunch populations is solved numerically. Results of the tracking method agree very well with the RHIC data. With the faster method, significant discrepancies are found since the losses of particles diffusing out of the RF bucket due to intrabeam scattering are not modeled accurately enough. Finally, we use both methods to make predictions of the time evolution of the future {sup 208}Pb+{sup 82+} beams in the LHC at injection and collision energy. For this machine, the two methods agree well.

43 PARTICLE ACCELERATORS↗

Accelerated Aging of Fast Pyrolysis Bio-Oil Using Carbonyl Titration: Laboratory Analytical Procedure (LAP)

This laboratory analytical procedure covers the accelerated aging of fast pyrolysis bio-oils. Bio-oils undergo reactions that result in physical and chemical changes over time. These changes typically result in an increase in molecular weight, decrease in some functional groups such as carbonyls, and an increase in viscosity; additionally, the aging process often leads to phase separation. Studies have shown that accelerated aging of bio-oils using this method closely mimics room temperature aging for long periods of time (over 3 years). This procedure has been developed for the accelerated aging of fast pyrolysis bio-oils only. Fast pyrolysis bio-oils are more reactive than other bio-oils (e.g., catalytic fast pyrolysis) and undergo aging much more rapidly. Therefore, this procedure should only be used for fast pyrolysis bio-oil samples.

09 BIOMASS FUELS↗

Precise Determination of the Helical Repeat of Tobacco Mosaic Virus

Tobacco mosaic virus (TMV) is widely used as a distance standard in electron microscopy, fiber diffraction, and other imaging techniques. The dimension used as a reference is the pitch of the viral helix, 23 {angstrom}. This distance, however, has never been measured with any great degree of precision. The helical pitch of TMV has been determined to be 22.92 {+-}0.03 {angstrom} by X-ray fiber diffraction methods using highly collimated synchrotron radiation.

43 PARTICLE ACCELERATORS↗

Particle-in-cell simulations of particle energization from low Mach number fast mode shocks

Astrophysical shocks are often studied in the high Mach number limit but weakly compressive fast shocks can occur in magnetic reconnection outflows and are considered to be a site of particle energization in solar flares. Here we study the microphysics of such perpendicular, low Mach number collisionless shocks using two-dimensional particle-in-cell simulations with a reduced ion/electron mass ratio and employ a moving wall boundary method for initial generation of the shock. This moving wall method allows for more control of the shock speed, smaller simulation box sizes, and longer simulation times than the commonly used fixed wall, reflection method of shock formation. Our results, which are independent of the shock formation method, reveal the prevalence shock drift acceleration (SDA) of both electron and ions in a purely perpendicular shock with Alfven Mach number M{sub A}=6.8 and ratio of thermal to magnetic pressure {beta}=8. We determine the respective minimum energies required for electrons and ions to incur SDA. We derive a theoretical electron distribution via SDA that compares to the simulation results. We also show that a modified two-stream instability due to the incoming and reflecting ions in the shock transition region acts as the mechanism to generate collisionless plasma turbulence that sustains the shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extraction of neutron structure from tagged structure functions

We present work in a model used to describe semi-inclusive deep inelastic scattering off the deuteron. The model uses the virtual nucleon approximation to describe the interaction of the photon with the bound neutron and the generalized eikonal approximation is applied to calculate the final-state interaction diagram. Comparison with data taken at Jefferson Lab shows good agreement in the covered range of kinematics and points at a largely suppressed off-shell rescattering amplitude. The W and Q{sup 2} dependences of the total cross section and slope factor of the interaction of DIS products, X, off the spectator nucleon are extracted. Starting from the JLab data and our model calculations, we outline and apply an extrapolation method to obtain the neutron structure function F{sub 2N} at high Bjorken x.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnosis of bubble evolution in laser-wakefield acceleration via angular distributions of betatron x-rays

We present an indirect method to diagnose the electron beam behaviors and bubble dynamic evolution in a laser-wakefield accelerator. Four kinds of typical bubble dynamic evolution and, hence, electron beam behaviors observed in Particle-In-Cell simulations are identified correspondingly by simultaneous measurement of distinct angular distributions of the betatron radiation and electron beam energy spectra in experiment. The reconstruction of the bubble evolution may shed light on finding an effective way to better generate high-quality electron beams and enhanced betatron X-rays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast and scalable quantum Monte Carlo simulations of electron-phonon models

We introduce methodologies for highly scalable quantum Monte Carlo simulations of electron-phonon models, and report benchmark results for the Holstein model on the square lattice. The determinant quantum Monte Carlo (DQMC) method is a widely used tool for simulating simple electron-phonon models at finite temperatures, but incurs a computational cost that scales cubically with system size. Alternatively, near-linear scaling with system size can be achieved with the hybrid Monte Carlo (HMC) method and an integral representation of the Fermion determinant. Here, we introduce a collection of methodologies that make such simulations even faster. To combat "stiffness" arising from the bosonic action, we review how Fourier acceleration can be combined with time-step splitting. To overcome phonon sampling barriers associated with strongly-bound bipolaron formation, we design global Monte Carlo updates that approximately respect particle-hole symmetry. To accelerate the iterative linear solver, we introduce a preconditioner that becomes exact in the adiabatic limit of infinite atomic mass. Finally, we demonstrate how stochastic measurements can be accelerated using fast Fourier transforms. Here, these methods are all complementary and, combined, may produce multiple orders of magnitude speedup, depending on model details.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-761: TOMOMC, A Monte Carlo-Based Planning VerificationTool for Helical Tomotherapy

Purpose: Present a new Monte Carlo code (TOMOMC) to calculate 3D dose distributions for patients undergoing helical tomotherapy treatments. TOMOMC performs CT-based dose calculations using the actual dynamic variables of the machine (couch motion, gantry rotation, and MLC sequences). Methods: TOMOMC is based on the GEPTS (Gama Electron and Positron Transport System) general-purpose Monte Carlo system (Chibani and Li, Med. Phys. 29, 2002, 835). First, beam models for the Hi-Art Tomotherpy machine were developed for the different beam widths (1, 2.5 and 5 cm). The beam model accounts for the exact geometry and composition of the different components of the linac head (target, primary collimator, jaws and MLCs). The beams models were benchmarked by comparing calculated Pdds and lateral/transversal dose profiles with ionization chamber measurements in water. See figures 1–3. The MLC model was tuned in such a way that tongue and groove effect, inter-leaf and intra-leaf transmission are modeled correctly. See figure 4. Results: By simulating the exact patient anatomy and the actual treatment delivery conditions (couch motion, gantry rotation and MLC sinogram), TOMOMC is able to calculate the 3D patient dose distribution which is in principal more accurate than the one from the treatment planning system (TPS) since it relies on the Monte Carlo method (gold standard). Dose volume parameters based on the Monte Carlo dose distribution can also be compared to those produced by the TPS. Attached figures show isodose lines for a H&N patient calculated by TOMOMC (transverse and sagittal views). Analysis of differences between TOMOMC and TPS is an ongoing work for different anatomic sites. Conclusion: A new Monte Carlo code (TOMOMC) was developed for Tomotherapy patient-specific QA. The next step in this project is implementing GPU computing to speed up Monte Carlo simulation and make Monte Carlo-based treatment verification a practical solution.

60 APPLIED LIFE SCIENCES↗

Assessment and Improvement Proposals for High-Pressure Rinsing Processes during Cleanroom Preparation of Superconducting Radio-Frequency Cavities for Particle Accelerators

The goal of this internship is to develop a fluid dynamics characterization of the high-pressure flow used for cleaning the internal surface of the SRF cavities. Initially, the High Pressure Rinsing (HPR) process is introduced, focusing on the problems of the SRF cavities and how this method can be used to increase their acceleration efficiency and performance. The characterization of the problem is then presented, including an introduction to the multiphase flow modeling and the analysis of the Fermilab facility for the HPR. To accomplish the goal, a preliminary estimation of the variables was performed using MATLAB. Then, multiple 2D simulations were developed with Ansys Fluent, and the influence of the main parameter was investigated. The simulation results are then presented and analysed, with a focus on the possible future developments of the HPR process fluid dynamic characterization.

43 PARTICLE ACCELERATORS↗

Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers

Purpose: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). Methods and Materials: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed. Results: The mean seroma volume was 36.9 cm{sup 3} and 34.2 cm{sup 3} for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 {+-} 1.0 from 2.5 {+-} 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001). Conclusions: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cylindrical Magnetron Development for Nb3sn Deposition via Magnetron Sputtering

Due to its better superconducting properties (critical temperature Tc~ 18.3 K, superheating field Hsh~ 400 mT), Nb₃Sn is considered as a potential alternative to niobium (Tc~ 9.25 K, Hsh~ 200 mT) for superconducting radiofrequency (SRF) cavities for particle acceleration. Magnetron sputtering is an effective method to produce superconducting Nb₃Sn films. We deposited superconducting Nb₃Sn films on samples with magnetron sputtering using co-sputtering, sequential sputtering, and sputtering from a stoichiometric target. Nb₃Sn films produced by magnetron sputtering in our previous experiments have achieved DC superconducting critical temperature up to 17.93 K and RF superconducting transition at 17.2 K. A magnetron sputtering system with two identical cylindrical cathodes that can be used to sputter Nb₃Sn films on cavities has been designed and is under development now. We report on the design and the current progress on the development of the system.

43 PARTICLE ACCELERATORS↗

Final Report: MATERIALS, STRANDS, AND CABLES FOR SUPERCONDUCTING ACCELERATOR MAGNETS [Grant Number DE-SC0010312]

Our program consisted of the two components: Strand Research and Cable Research, with a focus on Nb3Sn, Bi2212, and YBCO for accelerator magnet applications. We demonstrated a method to refine the grains in Nb3Sn by a factor of two, reaching 45 nm grain sizes, and layer Jcs of 6 kA/mm2 at 12 T. W also measured conductor magnetization for field quality. This has been done both with Nb3Sn conductor, as well as Bi:2212 strand. Work in support of quench studies of YBCO coils was also performed. Cable loss studies in Nb3Sn focused on connecting and comparing persistent magnetization and coupling magnetization for considering their relative impact on HEP machines. In the area of HTS cables, we have investigated both the quench in multistrand YBCO CORC cables, as well as the magnetization of these cables for use in high field magnets. In addition, we examined the magnetic and thermal properties of large (50 T) solenoids.

43 PARTICLE ACCELERATORS↗

SU-E-T-644: QuAArC: A 3D VMAT QA System Based On Radiochromic Film and Monte Carlo Simulation of Log Files

Purpose: VMAT involves two main sources of uncertainty: one related to the dose calculation accuracy, and the other linked to the continuous delivery of a discrete calculation. The purpose of this work is to present QuAArC, an alternative VMAT QA system to control and potentially reduce these uncertainties. Methods: An automated MC simulation of log files, recorded during VMAT treatment plans delivery, was implemented in order to simulate the actual treatment parameters. The linac head models and the phase-space data of each Control Point (CP) were simulated using the EGSnrc/BEAMnrc MC code, and the corresponding dose calculation was carried out by means of BEAMDOSE, a DOSXYZnrc code modification. A cylindrical phantom was specifically designed to host films rolled up at different radial distances from the isocenter, for a 3D and continuous dosimetric verification. It also allows axial and/or coronal films and point measurements with several types of ion chambers at different locations. Specific software was developed in MATLAB in order to process and evaluate the dosimetric measurements, which incorporates the analysis of dose distributions, profiles, dose difference maps, and 2D/3D gamma index. It is also possible to obtain the experimental DVH reconstructed on the patient CT, by an optimization method to find the individual contribution corresponding to each CP on the film, taking into account the total measured dose, and the corresponding CP dose calculated by MC. Results: The QuAArC system showed high reproducibility of measurements, and consistency with the results obtained with the commercial system implemented in the verification of the evaluated treatment plans. Conclusion: A VMAT QA system based on MC simulation and high resolution dosimetry with film has been developed for treatment verification. It shows to be useful for the study of the real VMAT capabilities, and also for linac commissioning and evaluation of other verification devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗