Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array

Purpose: The purpose of this study was to determine whether a two-dimensional (2D) ion chamber array detector quickly and accurately measures patient-specific dose distributions in treatment with passively scattered and spot scanning proton beams. Methods: The 2D ion chamber array detector MatriXX was used to measure the dose distributions in plastic water phantom from passively scattered and spot scanning proton beam fields planned for patient treatment. Planar dose distributions were measured using MatriXX, and the distributions were compared to those calculated using a treatment-planning system. The dose distributions generated by the treatment-planning system and a film dosimetry system were similarly compared. Results: For passively scattered proton beams, the gamma index for the dose-distribution comparison for treatment fields for three patients with prostate cancer and for one patient with lung cancer was less than 1.0 for 99% and 100% of pixels for a 3% dose tolerance and 3 mm distance-to-dose agreement, respectively. For spot scanning beams, the mean ({+-} standard deviation) percentages of pixels with gamma indices meeting the passing criteria were 97.1%{+-}1.4% and 98.8%{+-}1.4% for MatriXX and film dosimetry, respectively, for 20 fields used to treat patients with prostate cancer. Conclusions: Unlike film dosimetry, MatriXX provides not only 2D dose-distribution information but also absolute dosimetry in fractions of minutes with acceptable accuracy. The results of this study indicate that MatriXX can be used to verify patient-field specific dose distributions in proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Monte Carlo calculations for reference dosimetry of electron beams with the PTW Roos and NE2571 ion chambers

Purpose: To investigate recommendations for reference dosimetry of electron beams and gradient effects for the NE2571 chamber and to provide beam quality conversion factors using Monte Carlo simulations of the PTW Roos and NE2571 ion chambers. Methods: The EGSnrc code system is used to calculate the absorbed dose-to-water and the dose to the gas in fully modeled ion chambers as a function of depth in water. Electron beams are modeled using realistic accelerator simulations as well as beams modeled as collimated point sources from realistic electron beam spectra or monoenergetic electrons. Beam quality conversion factors are calculated with ratios of the doses to water and to the air in the ion chamber in electron beams and a cobalt-60 reference field. The overall ion chamber correction factor is studied using calculations of water-to-air stopping power ratios. Results: The use of an effective point of measurement shift of 1.55 mm from the front face of the PTW Roos chamber, which places the point of measurement inside the chamber cavity, minimizes the difference betweenR{sub 50}, the beam quality specifier, calculated from chamber simulations compared to that obtained using depth-dose calculations in water. A similar shift minimizes the variation of the overall ion chamber correction factor with depth to the practical range and reduces the root-mean-square deviation of a fit to calculated beam quality conversion factors at the reference depth as a function of R{sub 50}. Similarly, an upstream shift of 0.34 r{sub cav} allows a more accurate determination of R{sub 50} from NE2571 chamber calculations and reduces the variation of the overall ion chamber correction factor with depth. The determination of the gradient correction using a shift of 0.22 r{sub cav} optimizes the root-mean-square deviation of a fit to calculated beam quality conversion factors if all beams investigated are considered. However, if only clinical beams are considered, a good fit to results for beam quality conversion factors is obtained without explicitly correcting for gradient effects. The inadequacy of R{sub 50} to uniquely specify beam quality for the accurate selection of k{sub Q} factors is discussed. Systematic uncertainties in beam quality conversion factors are analyzed for the NE2571 chamber and amount to between 0.4% and 1.2% depending on assumptions used. Conclusions: The calculated beam quality conversion factors for the PTW Roos chamber obtained here are in good agreement with literature data. These results characterize the use of an NE2571 ion chamber for reference dosimetry of electron beams even in low-energy beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation forces of a highly focused radially polarized beam on spherical particles

A radially polarized beam focused by a high-numerical-aperture (NA) objective has a strong longitudinal and nonpropagating electric field in the focal region, which implies that it is suitable for axial optical trapping. In this paper, we use the vectorial diffraction integral to represent the field distribution of the radially polarized beam focused by a high-NA objective and then employ the T-matrix method to compute the radiation forces on spherical particles. Effects of different parameters, such as the size of the sphere, the inner radius of the radially polarized beam, and the NA of the objective, on the radiation forces are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton Core Heating and Beam Formation via Parametrically Unstable Alfven-Cyclotron Waves

Vlasov theory and one-dimensional hybrid simulations are used to study the effects that compressible fluctuations driven by parametric instabilities Alfven-cyclotron waves have on proton velocity distributions. Field-aligned proton beams are generated during the saturation phase of the wave-particle interaction, with a drift speed which is slightly greater than the Alfven speed and is maintained until the end of the simulation. The main part of the distribution becomes anisotropic due to phase mixing as is typically observed in the velocity distributions measured in the fast solar wind. We identify the key instabilities and also find that, even in the parameter regime where fluid theory appears to be appropriate, strong kinetic effects still prevail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction of space charge breakdown in e-beam irradiated nano/polymethyl methacrylate composites

Fast discharge of numerous space charges in dielectric materials can cause space charge breakdown. This letter reports the role of nanoparticles in affecting space charge breakdown of nano/polymethyl methacrylate composites. Space charge distributions in the composites, implanted by electron beam irradiation, were measured by pressure wave propagation method. The results show that the nanoparticles have significant effects on the isothermal charge decay and space charge breakdown in the nanocomposites. The resistance to space charge breakdown in the nanocomposites is attributed to the combined action of the introduction of deep trapping states and the scattering effect by the added nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Competition of coalescence and 'fireball' processes in nonequilibrium emission of light charged particles from p+Au collisions

The energy and angular dependence of the double differential cross sections d{sup 2}{sigma}/d{omega}dE were measured for p,d,t,{sup 3,4,6}He, {sup 6,7,8,9}Li, {sup 7,9,10}Be, and {sup 10,11,12}B isotopes produced in reactions of 1.2- and 1.9-GeV protons on a Au target. The beam energy dependence of the data, supplemented by the cross sections from a previous experiment at 2.5 GeV, is very smooth. The shape of the spectra and angular distributions do not change significantly in the beam energy range from 1.2 to 2.5 GeV. However, the absolute value of the cross sections increases for all ejectiles. The intermediate mass fragment spectra and their angular distributions are very well reproduced by a phenomenological model of two emitting, moving sources, with parameters smoothly varying with energy. The double differential cross sections for light charged particles were analyzed in the framework of the microscopic model calculations of intranuclear cascade, including the coalescence of nucleons and a statistical model for evaporation of particles from excited residual nuclei. However, the energy and angular dependencies of the data agree with neither predictions of the microscopic intranuclear cascade calculations for protons nor the coalescence calculations for other light charged particles. A very good description of the data is achieved by the phenomenological inclusion of the emission of light charged particles from a 'fireball' (i.e., a fast and hot moving source). It was found that the nonequilibrium processes are very important for the production of light charged particles. They exhaust 40%-80% of the total cross section--depending on the emitted particles. Coalescence and fireball emission yield comparable contributions to the cross sections with the exception of the {sup 3}He data where coalescence clearly dominates. For all light charged particles, the ratio of nonequilibrium processes to processes proceeding through a phase of statistical equilibrium does not change significantly between the beam energies of 1.2 and 2.5 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Angular Distributions of Gamma Rays from the Inelastic Scattering of 14.1-MeV Neutrons by Carbon and Oxygen Nuclei

The results obtained by measuring the angular and energy distributions of gamma rays originating from the inelastic scattering of 14.1-MeV neutrons by carbon and oxygen nuclei are presented. The measurements in question were performed by the tagged-neutron method in a beam of an ING-27 standard portable neutron generator. The angular distributions of gamma rays emitted by the 2{sup +} state of {sup 12}С at 4.43 MeVand the 3{sup −} state of {sup 16}O at 6.13 MeV were obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostics for measuring 4D beam matrix [Slides]

Detailed knowledge on the particle distribution in accelerators can strongly benefit machine tuning and understanding of deleterious effects, which degrade beam quality. Properties of the beam downstream the beamline (i.e. 4D beam matrix) depend on beam properties upstream and parameters of the beamline. Measuring 2D x-y beam profile downstream provides limited information about the beam. Multiple measurements at different settings of the beamline (quadrupole scan) may provide enough information to recover original beam profile. Essentially, this concept is similar to tomography, when we need to reconstruct a higher dimension object from multiple low dimension projections.

43 PARTICLE ACCELERATORS↗

Control over the space-time structure of electron beams by high-intensity femtosecond laser radiation

The space-velocity distribution of electrons propagating in vacuum can be deformed by the ponderomotive potential produced by high-intensity femtosecond laser pulses, which makes it possible to subsequently separate such electrons from the initial beam. It is shown that optical modification of electron beams with kinetic energies on the order of 100 eV by femtosecond laser radiation with an intensity from 10{sup 14} to 10{sup 18} W/cm{sup 2} makes it possible to form electron beams with a duration on the order of 50-100 fs. Examples of optical control over the shape of electron beams, based on deflection, reflection, focusing, and splitting of electron beams, are considered.

43 PARTICLE ACCELERATORS↗

DISCOVERY OF A HOT CORINO IN THE BOK GLOBULE B335

We report the first evidence of a hot corino in a Bok globule. This is based on ALMA observations in the 1.2 mm band toward the low-mass Class 0 protostar IRAS 19347+0727 in B335. Saturated complex organic molecules (COMs), CH{sub 3}CHO, HCOOCH{sub 3}, and NH{sub 2}CHO, are detected in a compact region within a few 10 au around the protostar. Additionally, CH{sub 3}OCH{sub 3}, C{sub 2}H{sub 5}OH, C{sub 2}H{sub 5}CN, and CH{sub 3}COCH{sub 3} are tentatively detected. Carbon-chain related molecules, CCH and c-C{sub 3}H{sub 2}, are also found in this source, whose distributions are extended over a scale of a few 100 au. On the other hand, sulfur-bearing molecules CS, SO, and SO{sub 2} have both compact and extended components. Fractional abundances of the COMs relative to H{sub 2} are found to be comparable to those in known hot corino sources. Though the COMs lines are as broad as 5–8 km s{sup −1}, they do not show obvious rotation motion in the present observation. Thus, the COMs mainly exist in a structure whose distribution is much smaller than the synthesized beam (0.″58 × 0.″52).

79 ASTRONOMY AND ASTROPHYSICS↗

Electron distributions in quasi-perpendicular shocks: Simulations

One of the outstanding problems of collisionless shock physics is the microphysical description of electron thermalization and associated wave processes. Observations at the Earth's bow shock have shown various features in the electron velocity distribution such as a loss-cone, temperature anisotropies, and beams before a thermalized, flat-topped distribution is reached downstream. It is generally believed that in addition to the macroscopic fields, which determine the overall mapping of the distribution function, electromagnetic whistler waves and lower hybrid waves are responsible for the pitch-angle scattering and thermalization of the electrons. However, a genuine physical explanation requires analysis of the evolution of the electron distribution in the self-consistent wave fields. Particle simulations are ideally suited to do this, and include processes in which both electrons and ions are involved, such as cross-field streaming instabilities. We show results from l-D and 2-D simulations using an implicit code, which allows time steps large compared to the inverse electron plasma frequency. It is shown that in order to capture the correct propagation characteristics of the waves, a large mass ratio between the protons and electrons is generally necessary. Detailed diagnostics of the waves as well as the evolution of the electron velocity distribution will be presented and will be discussed in the frame work of satellite observations.

Pantellini, F.↗

Polarization of photons scattered by electrons in any spectral distribution

On the basis of the quantum electrodynamics, we present a generic formalism of the polarization for beamed monochromatic photons scattered by electrons in any spectral distribution. The formulae reduce to the components of the Fano matrix when electrons are at rest. We mainly investigate the polarization in three scenarios, i.e., electrons at rest, isotropic electrons with a power-law spectrum, and thermal electrons. If the incident beam is polarized, the polarization is reduced significantly by isotropic electrons at large viewing angles; the degree of polarization caused by thermal electrons is about half of that caused by power-law electrons. If the incident bean is unpolarized, soft γ-rays can lead to about 15% polarization at viewing angles around π/4. For isotropic electrons, one remarkable feature is that the polarization as a function of the incident photon energy always peaks roughly at 1 MeV; this is valid for both the thermal and power-law cases. This feature can be used to distinguish the model of the inverse Compton scattering from that of the synchrotron radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase-space tailoring and cooling of charged-particle beams for energy- and intensity-frontier applications

This project addressed accelerator science & technology researches relevant to the Intensity and Energy frontiers by investigating generic techniques to tailor and cool the phase-space distributions of charged-particle beams. Specifically, the project had two main research thrusts: (i) the development of phase-space tailoring techniques using externally-applied electromagnetic fields and (ii) the investigation of phase-space control using the beam’s self-field such as the optical-stochastic cooling (OSC). The work related to the development of phase-space-tailoring techniques leveraged on the research performed under our previous grant DE-SC0011831 where new temporal-shaping methods were proposed and some experimentally demonstrated. The work related to the concept of beam manipulation using self fields, and especially OSC, built on the achievements supported by grant DE-SC0013761 which focused on a OSC proof-of-principle experiment at the Fermilab’s IOTA ring.

43 PARTICLE ACCELERATORS↗

The temperature and size distribution of large water clusters from a non-equilibrium model

A hybrid Lagrangian-Eulerian approach is used to examine the properties of water clusters formed in neon-water vapor mixtures expanding through microscale conical nozzles. Experimental size distributions were reliably determined by the sodium doping technique in a molecular beam machine. The comparison of computed size distributions and experimental data shows satisfactory agreement, especially for (H{sub 2}O){sub n} clusters with n larger than 50. Thus validated simulations provide size selected cluster temperature profiles in and outside the nozzle. This information is used for an in-depth analysis of the crystallization and water cluster aggregation dynamics of recently reported supersonic jet expansion experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hard X-ray inverse Compton scattering at photon energy of 87.5 keV

Abstract Production of hard X-ray via inverse Compton scattering at photon energies below 100 keV range aimed at potential applications in medicine and material research is reported. Experiments have been performed at the Brookhaven National Laboratory, Accelerator Test Facility, employing the counter collision of a 70 MeV, 0.3 nC electron beam with a near infra-red Nd: YAG laser (1064 nm wavelength) pulse containing ~ 100 mJ in a single shot basis. The radiation distribution of the scattered photon beam is assessed to be sufficiently quasi monochromatic to produce clear contrast from the Au K - edge at 80.7 keV.

43 PARTICLE ACCELERATORS↗

Electric field measurement in microwave discharge ion thruster with electro-optic probe

In order to understand the internal phenomena in a microwave discharge ion thruster, it is important to measure the distribution of the microwave electric field inside the discharge chamber, which is directly related to the plasma production. In this study, we proposed a novel method of measuring a microwave electric field with an electro-optic (EO) probe based on the Pockels effect. The probe, including a cooling system, contains no metal and can be accessed in the discharge chamber with less disruption to the microwave distribution. This method enables measurement of the electric field profile under ion beam acceleration. We first verified the measurement with the EO probe by a comparison with a finite-difference time domain numerical simulation of the microwave electric field in atmosphere. Second, we showed that the deviations of the reflected microwave power and the beam current were less than 8% due to inserting the EO probe into the ion thruster under ion beam acceleration. Finally, we successfully demonstrated the measurement of the electric-field profile in the ion thruster under ion beam acceleration. These measurements show that the electric field distribution in the thruster dramatically changes in the ion thruster under ion beam acceleration as the propellant mass flow rate increases. These results indicate that this new method using an EO probe can provide a useful guide for improving the propulsion of microwave discharge ion thrusters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar cycle variation of some mass dependent characteristics of upflowing beams of terrestrial ions

Examination of the S3-3 and DE ion composition data spread over a solar cycle indicates that some characteristics of energetic upflowing terrestrial ion beams above the auroral zone show dependence on solar cycle. At solar maximum the different ion beam mass components have comparable mean energies, and O(+) dominates the beam composition. The ion energies are consistent with having been acquired from the potential drop below the satellite inferred from the electron loss cone distributions. At solar minimum the beam composition is dominated by H(+), but the O(+) has a higher mean energy and is hotter than the H(+) component. Also, the O(+) has more energy than it could itself have acquired from the potential drop. These observations are qualitatively consistent with the ion beams having acquired their energies from a parallel electric field and being partially thermalized through the two-stream instability between the two ion species, with this effect being modulated by the beam composition.

Collin, H. L.↗