SU-E-I-17: Evaluation of Commercially Available Extension Plates for the ACR CT Accreditation Phantom

Purpose: To evaluate the impact of commercially available extension plates on Hounsfield Unit (HU) values in the ACR CT accreditation phantom (Model 464, Gammex Inc., Middleton, Wi). The extension plates are intended to improve water HU values in scanners where the traditional solution involves scanning the phantom with an adjacent water or CTDI phantom. Methods: The Model 464 phantom was scanned on 9 different CT scanners at 8 separate sites representing 16 and 64 slice MDCT technology from four CT manufacturers. The phantom was scanned with and without the extension plates (Gammex 464 EXTPLT-KIT) in helical and axial modes. A water phantom was also scanned to verify water HU calibration. Technique was 120 kV tube potential, 350 mAs, and 210 mm display field of view. Slice thickness and reconstruction algorithm were based on site clinical protocols. The widest available beam collimation was used. Regions of interest were drawn on the HU test objects in Module 1 of the phantom and mean values recorded. Results: For all axial mode scans, water HU values were within limits with or without the extension plates. For two scanners (both Lightspeed VCT, GE Medical Systems, Waukesha WI), axial mode bone HU values were above the specified range both with and without the extension plates though they were closer to the specified range with the plates installed. In helical scan mode, two scanners (both GE Lightspeed VCT) had water HU values above the specified range without the plates installed. With the plates installed, the water HU values were within range for all scanners in all scan modes. Conclusion: Using the plates, the Lightspeed VCT scanners passed the water HU test when scanning in helical mode. The benefit of the extension plates was evident in helical mode scanning with GE scanners using a nominal 4 cm beam. Disclosure: The extension plates evaluated in this work were provided free of charge to the authors. The authors have no other financial interest in Gammex Inc.

60 APPLIED LIFE SCIENCES↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

Sensitivity study of voxel-based PET image comparison to image registration algorithms

Purpose: Accurate deformable registration is essential for voxel-based comparison of sequential positron emission tomography (PET) images for proper adaptation of treatment plan and treatment response assessment. The comparison may be sensitive to the method of deformable registration as the optimal algorithm is unknown. This study investigated the impact of registration algorithm choice on therapy response evaluation. Methods: Sixteen patients with 20 lung tumors underwent a pre- and post-treatment computed tomography (CT) and 4D FDG-PET scans before and after chemoradiotherapy. All CT images were coregistered using a rigid and ten deformable registration algorithms. The resulting transformations were then applied to the respective PET images. Moreover, the tumor region defined by a physician on the registered PET images was classified into progressor, stable-disease, and responder subvolumes. Particularly, voxels with standardized uptake value (SUV) decreases >30% were classified as responder, while voxels with SUV increases >30% were progressor. All other voxels were considered stable-disease. The agreement of the subvolumes resulting from difference registration algorithms was assessed by Dice similarity index (DSI). Coefficient of variation (CV) was computed to assess variability of DSI between individual tumors. Root mean square difference (RMS{sub rigid}) of the rigidly registered CT images was used to measure the degree of tumor deformation. RMS{sub rigid} and DSI were correlated by Spearman correlation coefficient (R) to investigate the effect of tumor deformation on DSI. Results: Median DSI{sub rigid} was found to be 72%, 66%, and 80%, for progressor, stable-disease, and responder, respectively. Median DSI{sub deformable} was 63%–84%, 65%–81%, and 82%–89%. Variability of DSI was substantial and similar for both rigid and deformable algorithms with CV > 10% for all subvolumes. Tumor deformation had moderate to significant impact on DSI for progressor subvolume with R{sub rigid} = − 0.60 (p = 0.01) and R{sub deformable} = − 0.46 (p = 0.01–0.20) averaging over all deformable algorithms. For stable-disease subvolumes, the correlations were significant (p < 0.001) for all registration algorithms with R{sub rigid} = − 0.71 and R{sub deformable} = − 0.72. Progressor and stable-disease subvolumes resulting from rigid registration were in excellent agreement (DSI > 70%) for RMS{sub rigid} < 150 HU. However, tumor deformation was observed to have negligible effect on DSI for responder subvolumes with insignificant |R| < 0.26, p > 0.27. Conclusions: This study demonstrated that deformable algorithms cannot be arbitrarily chosen; different deformable algorithms can result in large differences of voxel-based PET image comparison. For low tumor deformation (RMS{sub rigid} < 150 HU), rigid and deformable algorithms yield similar results, suggesting deformable registration is not required for these cases.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulated proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a production of MGS Research, Inc.

60 APPLIED LIFE SCIENCES↗

Rectal Dose-Volume Differences Using Proton Radiotherapy and a Rectal Balloon or Water Alone for the Treatment of Prostate Cancer

Purpose: To describe dose-volume values with the use of water alone vs. a rectal balloon (RB) for the treatment of prostate cancer with proton therapy. Materials and Methods: We analyzed 30 proton plans for 15 patients who underwent CT and MRI scans with an RB or water alone. Simulation was performed with a modified MRI endorectal coil and an RB with 100 mL of water or water alone. Doses of 78-82 gray equivalents were prescribed to the planning target volume. The two groups were compared for three structures: rectum, rectal wall (RW), and rectal wall 7 cm (RW7) at the level of the planning target volume. Results: Rectum and RW volumes radiated to low, intermediate, and high doses were small: rectum V10, 33.7%; V50, 17.3%; and V70, 10.2%; RW V10, 32.4%; V50, 20.4%; and V70, 14.6%. The RB effectively increased the rectal volume for all cases (139.8 {+-} 44.9 mL vs. 217.7 {+-} 32.2 mL (p < 0.001). The RB also decreased the volume of the rectum radiated to doses V10-V65 (p {<=} 0.05); RW for V10-V50; and RW7 for V10-V35. An absolute rectum V50 improvement >5% was seen for the RB in 5 of 15 cases, for a benefit of 9.2% {+-} 2.3% compared with 2.4% {+-} 1.3% for the remaining 10 cases (p < 0.001). Similar benefit was seen for the rectal wall. No benefit was seen for doses {>=}70 gray equivalents for the rectum, RW, or RW7. No benefit of {<=}1% was seen with an RB in 46% for the rectum V70 and in 40% for the rectal wall V70. Conclusions: Rectum and rectal wall doses with proton radiation were low whether using water or an RB. Selected patients will have a small but significant advantage with an RB; however, water alone was well tolerated and will be an alternative for most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated Magnetic Resonance Imaging in the Radiotherapy Clinic

Purpose: To introduce a novel technology arrangement in an integrated environment and outline the logistics model needed to incorporate dedicated magnetic resonance (MR) imaging in the radiotherapy workflow. An initial attempt was made to analyze the value and feasibility of MR-only imaging compared to computed tomography (CT) imaging, testing the assumption that MR is a better choice for target and healthy tissue delineation in radiotherapy. Methods and Materials: A 1.5-T MR unit with a 70-cm-bore size was installed close to a linear accelerator, and a special trolley was developed for transporting patients who were fixated in advance between the MR unit and the accelerator. New MR-based workflow procedures were developed and evaluated. Results: MR-only treatment planning has been facilitated, thus avoiding all registration errors between CT and MR scans, but several new aspects of MR imaging must be considered. Electron density information must be obtained by other methods. Generation of digitally reconstructed radiographs (DRR) for x-ray setup verification is not straight forward, and reliable corrections of geometrical distortions must be applied. The feasibility of MR imaging virtual simulation has been demonstrated, but a key challenge to overcome is correct determination of the skeleton, which is often needed for the traditional approach of beam modeling. The trolley solution allows for a highly precise setup for soft tissue tumors without the invasive handling of radiopaque markers. Conclusions: The new logistics model with an integrated MR unit is efficient and will allow for improved tumor definition and geometrical precision without a significant loss of dosimetric accuracy. The most significant development needed is improved bone imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Combined Intensity-Modulated Radiotherapy (IMRT) and Proton Therapy Versus IMRT Alone for Pelvic and Para-Aortic Radiotherapy in Gynecologic Malignancies

Purpose: To perform a dosimetric comparison of intensity-modulated radiotherapy (IMRT), passive scattering proton therapy (PSPT), and intensity-modulated proton therapy (IMPT) to the para-aortic (PA) nodal region in women with locally advanced gynecologic malignancies. Methods and Materials: The CT treatment planning scans of 10 consecutive patients treated with IMRT to the pelvis and PA nodes were identified. The clinical target volume was defined by the primary tumor for patients with cervical cancer and by the vagina and paravaginal tissues for patients with endometrial cancer, in addition to the regional lymph nodes. The IMRT, PSPT, and IMPT plans were generated using the Eclipse Treatment Planning System and were analyzed for various dosimetric endpoints. Two groups of treatment plans including proton radiotherapy were created: IMRT to pelvic nodes with PSPT to PA nodes (PSPT/IMRT), and IMRT to pelvic nodes with IMPT to PA nodes (IMPT/IMRT). The IMRT and proton RT plans were optimized to deliver 50.4 Gy or Gy (relative biologic effectiveness [RBE)), respectively. Dose-volume histograms were analyzed for all of the organs at risk. The paired t test was used for all statistical comparison. Results: The small-bowel V{sub 20}, V{sub 30}, V{sub 35}, andV{sub 40} were reduced in PSPT/IMRT by 11%, 18%, 27%, and 43%, respectively (p < 0.01). Treatment with IMPT/IMRT demonstrated a 32% decrease in the small-bowel V{sub 20}. Treatment with PSPT/IMRT showed statistically significant reductions in the body V{sub 5-20}; IMPT/IMRT showed reductions in the body V{sub 5-15}. The dose received by half of both kidneys was reduced by PSPT/IMRT and by IMPT/IMRT. All plans maintained excellent coverage of the planning target volume. Conclusions: Compared with IMRT alone, PSPT/IMRT and IMPT/IMRT had a statistically significant decrease in dose to the small and large bowel and kidneys, while maintaining excellent planning target volume coverage. Further studies should be done to correlate the clinical significance of these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-118: Verification of Intrafractional Positional Accuracy Using Ultrasound Autoscan Tracking for Prostate Cancer Treatment

Purpose: Transperineal ultrasound imaging is attractive option for imageguided radiation therapy as there is no need to implant fiducials, no extra imaging dose, and real time continuous imaging is possible during treatment. The aim of this study is to verify the tracking accuracy of a commercial ultrasound system under treatment conditions with a male pelvic phantom. Methods: A CT and ultrasound scan were acquired for the male pelvic phantom. The phantom was then placed in a treatment mimicking position on a motion platform. The axial and lateral tracking accuracy of the ultrasound system were verified using an independent optical tracking system. The tracking accuracy was evaluated by tracking the phantom position detected by the ultrasound system, and comparing it to the optical tracking system under the conditions of beam on (15 MV), beam off, poor image quality with an acoustic shadow introduced, and different phantom motion cycles (10 and 20 second periods). Additionally, the time lag between the ultrasound-detected and actual phantom motion was investigated. Results: Displacement amplitudes reported by the ultrasound system and optical system were within 0.5 mm of each other for both directions and all conditions. The ultrasound tracking performance in axial direction was better than in lateral direction. Radiation did not interfere with ultrasound tracking while image quality affected tracking accuracy. The tracking accuracy was better for periodic motion with 20 second period. The time delay between the ultrasound tracking system and the phantom motion was clinically acceptable. Conclusion: Intrafractional prostate motion is a potential source of treatment error especially in the context of emerging SBRT regimens. It is feasible to use transperineal ultrasound daily to monitor prostate motion during treatment. Our results verify the tracking accuracy of a commercial ultrasound system to be better than 1 mm under typical external beam treatment conditions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-402: Y-90 Microspheres (SIR Spheres) for Treatment of Liver Metastasis : Technique

Purpose: The purpose of this presentation is to discuss the radiation safety and dosimetric technique used for the therapeutic procedure using Y-90 microspheres through intra -arterial administration on patients with liver metastasis Methods: The radiation dosimetry, technique and safety aspects of 14 patients with primary and metastatic liver cancer, treated with Y-90 microsphere (SIR spheres) are discussed. The liver and tumor volumes were determined using the CT and MR scans . The images were imported into the treatment planning system and the liver and tumor volumes and the volume of the liver affected were outlined and the volume calculation was performed using the software. The lung shunt fraction (LSF) and tumor to liver uptake ratio (TLR) were determined using the nuclear medicine SPECT imaging with Tc-99m MAA. The absorbed dose to the target volume in liver was calculated using the following equation:Dose ? (Gy) = C x E? x 5.92 x 10-6 (Gy/s) x T(1/2)(days) x 1.44 x 8.64 x 104 (s) The distribution of activity in the tumor bed was confirmed by post Y-90 administration imaging using the Bremsstrahlung peak at 30% window. The patient and the procedure room were surveyed and radiation safety instructions were given to the patient Results: The tumor volume ranged from 77 cc to 700 cc, tumor to liver uptake ranged from 3 to 12. The lung shunt fraction varied from 1.08% to 9.0%. The activity administered ranged from 1.0GBq to 2.5 GBq, . The radiation survey in contact with the patient ranged from 1.8 mR/hr to 2.5 mR/hr and reading at 1 meter was less than 0.2 mR/hr Conclusion: The technique for radiation dosimetry and radiation safety for Y-90 microsphere therapy is established. The post treatment imaging helped to confirm the distribution of Y-90 microspheres inside the tumor bed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-455: Characterization of 3D Printed Materials for Proton Beam Therapy

Purpose: The widespread availability of low cost 3D printing technologies provides an alternative fabrication method for customized proton range modifying accessories such as compensators and boluses. However the material properties of the printed object are dependent on the printing technology used. In order to facilitate the application of 3D printing in proton therapy, this study investigated the stopping power of several printed materials using both proton pencil beam measurements and Monte Carlo simulations. Methods: Five 3–4 cm cubes fabricated using three 3D printing technologies (selective laser sintering, fused-deposition modeling and stereolithography) from five printers were investigated. The cubes were scanned on a CT scanner and the depth dose curves for a mono-energetic pencil beam passing through the material were measured using a large parallel plate ion chamber in a water tank. Each cube was measured from two directions (perpendicular and parallel to printing plane) to evaluate the effects of the anisotropic material layout. The results were compared with GEANT4 Monte Carlo simulation using the manufacturer specified material density and chemical composition data. Results: Compared with water, the differences from the range pull back by the printed blocks varied and corresponded well with the material CT Hounsfield unit. The measurement results were in agreement with Monte Carlo simulation. However, depending on the technology, inhomogeneity existed in the printed cubes evidenced from CT images. The effect of such inhomogeneity on the proton beam is to be investigated. Conclusion: Printed blocks by three different 3D printing technologies were characterized for proton beam with measurements and Monte Carlo simulation. The effects of the printing technologies in proton range and stopping power were studied. The derived results can be applied when specific devices are used in proton radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-220: Computational Accuracy of Adaptive Convolution (AC) and Collapsed Cone Convolution (CCC) Algorithms in the Presence of Air Gaps

Purpose: To compare the percentage depth dose (PDD) computational accuracy of Adaptive Convolution (AC) and Collapsed Cone Convolution (CCC) algorithms in the presence of air gaps. Methods: A 30×30×30 cm{sup 3} solid water phantom with two 5cm air gaps was scanned with a CT simulator unit and exported into the Phillips Pinnacle™ treatment planning system. PDDs were computed using the AC and CCC algorithms. Photon energy of 6 MV was used with field sizes of 3×3 cm{sup 2}, 5×5 cm{sup 2}, 10×10 cm{sup 2}, 15×15 cm{sup 2}, and 20×20 cm{sup 2}. Ionization chamber readings were taken at different depths in water for all the field sizes. The percentage differences in the PDDs were computed with normalization to the depth of maximum dose (dmax). The calculated PDDs were then compared with measured PDDs. Results: In the first buildup region, both algorithms overpredicted the dose for all field sizes and under-predicted for all other subsequent buildup regions. After dmax in the three water media, AC under-predicted the dose for field sizes 3×3 and 5×5 cm{sup 2} and overpredicted for larger field sizes, whereas CCC under-predicted for all field sizes. Upon traversing the first air gap, AC showed maximum differences of –3.9%, −1.4%, 2.0%, 2.5%, 2.9% and CCC had maximum differences of −3.9%, −3.0%,–3.1%, −2.7%, −1.8% for field sizes 3×3, 5×5, 10×10, 15×15, and 20×20 cm{sup 2} respectively. Conclusion: The effect of air gaps causes a significant difference in the PDDs computed by both the AC and CCC algorithms in secondary build-up regions. AC computed larger values for the PDDs except at smaller field sizes. For CCC, the size of the errors in prediction of the PDDs has an inverse relationship with respect to field size. These effects should be considered in treatment planning where significant air gaps are encountered.

60 APPLIED LIFE SCIENCES↗

SU-E-T-257: Development of a New Endorectal Balloon with An Unfoldable Radiochromic Film for In-Vivo Rectal Dosimetry During Prostate Cancer Radiotherapy

Purpose: We developed an endorectal balloon for in-vivo rectal dosimetry in two-dimensions, and evaluated its dosimetric properties for the radiation treatment of prostate cancer. Methods: The endorectal balloon for in-vivo rectal dosimetry is equipped with a radiochromic film so that two-dimensional dose distribution can be measured in the rectal wall. The film is unrolled as the balloon is inflated, and it is rolled as the balloon is deflated. The outer diameter of the balloon is about 14 mm before inflating it, but its outer diameter can be increased up to about 50 mm after inflating it with 80 ml distilled water. The size of the film is 80(L) x 64(W) mm2, so large as to measure a dose distribution of an anterior half of the rectal wall. After it was inserted into a fabricated rectal phantom, the phantom was scanned by a CT scanner and 5 Gy was delivered to a target inside the phantom with a 15 MV photon beam in AP direction. Finally, the dose distribution measured in the endorectal balloon was compared with that of the treatment plan. Results: The two dose distributions were compared each other in the parallel and the perpendicular directions along an axis of the balloon. The two dose profiles analyzed from the radiochromic film agreed well with the plan within 3% for 15 MV photon beam. Conclusion: An endorectal balloon for two-dimensional in-vivo rectal dosimetry was developed and its dosimetric effectiveness was evaluated for the radiation treatment of prostate cancer. The measured dose distributions showed good agreement with the plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-495: Influence of Reduced Target-To-Nozzle Distance On Secondary Neutron Dose Equivalent in Proton and Carbon Ion Radiotherapy

Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominal and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.

60 APPLIED LIFE SCIENCES↗

MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.

60 APPLIED LIFE SCIENCES↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-181: Proton Therapy Tissue-Equivalence of 3D Printed Materials

Purpose: This work investigated the proton tissue-equivalence of various 3D printed materials. Methods: Three 3D printers were used to create 5 cm cubic phantoms made of different plastics with varying percentages of infill. White resin, polylactic acid (PLA), and NinjaFlex plastics were used. The infills ranged from 15% to 100%. Each phantom was scanned with a CT scanner to obtain the HU value. The relative linear stopping power (RLSP) was then determined using a multi-layer ion chamber in a 200 MeV proton beam. The RLSP was measured both parallel and perpendicular to the print direction for each material. Results: The HU values of the materials ranged from lung-equivalent (−820 HU σ160) when using a low infill, to soft-tissue-equivalent 159 (σ12). The RLSP of the materials depended on the orientation of the beam relative to the print direction. When the proton beam was parallel to the print direction, the RLSP was generally higher than the RLSP in the perpendicular orientation, by up to 45%. This difference was smaller (less than 6%) for the materials with 100% infill. For low infill cubes irradiated parallel to the print direction, the SOBP curve showed extreme degradation of the beam in the distal region. The materials with 15–25% infill had wide-ranging agreement with a clinical HU-RLSP conversion curve, with some measurements falling within 1% of the curve and others deviating up to 45%. The materials with 100% infill all fell within 7% of the curve. Conclusion: While some materials tested fall within 1% of a clinical HU-RLSP curve, caution should be taken when using 3D printed materials with proton therapy, as the orientation of the beam relative to the print direction can result in a large change in RLSP. Further investigation is needed to measure how the infill pattern affects the material RLSP. This work was supported by PHS grant CA180803.

60 APPLIED LIFE SCIENCES↗

SU-F-T-319: The Impact of Radiation Beam Obliquity and Air Gap Thickness On Optically Stimulated Luminescent in Vivo Dosimetry for Radiation Therapy

Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques. Measured doses, however, underestimate planned doses for plans that utilize thermoplastic mask immobilization. The purpose of this work was to quantify the effect of beam obliquity and air gap span between the mask and backscatter material, on measured-to-planned OSLD dose agreement. Methods: A previously-used thermoplastic mask was cut, reheated, and flattened to form a 33 by 9 cm{sup 2} stage approximately 2 mm thick. Two OSLDs were placed on the stage on 5 cm of solid water, covered with 50 by 50 by 5 mm{sup 3} square of bolus, and scanned in the CT simulator. Plans were created with 10 by 10 cm{sup 2} open fields using 4, 6, 10, and 15 MV photon beams at 0°, 45°, and 90° incidence. The isocenter was placed between the OSLDs at 5 mm depth. Dose was calculated and averaged for two OSLDs. Artificial air gaps of 3, 5, 10, and 20 mm were introduced in the plan and dose was recalculated for each energy/angle/gap combination. The experimental setup was replicated on a linear accelerator and air gaps were introduced by “bridging” the thermoplastic stage across solid water plastic of varying thickness. Fields were delivered as planned. OSLDs were read 12–15 hours after irradiation. Results: Measured-toplanned percent differences were constant with increasing gap thickness for 0° and 45° beam angles. At 90° and 0 cm gap, planned dose underestimated measured dose by 10–23% for all energies. This discrepancy decreased linearly to 0% with a 20 mm gap. OSLD signal did not decrease more than 6% for any gap span and energy. Conclusion: With the exception of parallel beam incidence, beam obliquity and air gap thickness did not have a substantial effect on measured-to-planned dose agreement.

07 ISOTOPE AND RADIATION SOURCES↗