Search NASA⌕ Search

SEARCH · Search NASA

Results for “Code Robustness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Microreactor Optimization Using Simulation And Economics (mouse)

Microreactor Optimization Using Simulation and Economics (MOUSE) is a tool that integrates both nuclear microreactor design and reactor economics to provide comprehensive evaluations and optimizations. This tool enables stakeholders to explore the interplay between technical and economic variables, guiding them towards effective and competitive microreactor solutions. For the reactor core simulations, MOUSE leverages the OpenMC Monte Carlo Particle Transport Code to perform detailed core simulations for various microreactor designs. The included OpenMC models are 2D core designs of a Liquid Metal Thermal Microreactor (LMTR), a Gas-Cooled TRISO-Fueled Microreactor (GCMR), and a Heat Pipe Microreactor. Beyond core design, MOUSE includes simplified calculations for: - Calculating the masses of heat exchangers within the system. - Mechanical power of pumps. - Estimating the area occupied by various buildings within the nuclear plant. For the economic analysis, MOUSE provides detailed bottom-up cost estimates, encompassing a wide range of costs including preconstruction costs, direct costs, indirect costs, training costs, financial costs, operation & maintenance (O&M) costs, and fuel costs. These cost estimations are developed using data from the MARVEL project and additional literature sources, enabling the calculation of total capital costs and levelized cost of energy for both first-of-a-kind and nth-of-a-kind microreactors. MOUSE also enables analysis of the cost drivers and competitiveness in the electricity market. MOUSE allows users to modify a wide array of technical and economic parameters to evaluate different scenarios and their impacts. Examples of these parameters include: Fuels, coolants, or reflector materials Enrichment levels Control drum materials and geometry Fuel pin geometry and materials Moderator pin geometry and materials Reactor core and reflector dimensions Packing factor for the TRISO particles Nuclear reactor power and reactor burnup Number of sensors Shielding thickness Reactor vessel and guard vessel dimensions Operational staff requirements Number of emergency shutdowns Levelization period Interest rate Construction duration Since MOUSE is powered by the WATTS toolkit, it supports optimization studies, parametric analyses, and uncertainty calculations/propagation. The optimization techniques enable users to identify optimal design and economic configurations. The parametric analysis tools allow users to explore the sensitivity of various parameters, while uncertainty propagation helps quantify the impact of uncertainties on overall performance and cost. User Interface and Workflow: Currently, MOUSE is a command-line-based tool. Users can input various reactor design or economic parameters, modify the designs, run simulations, and visualize results through comprehensive data visualization and reporting capabilities. The typical workflow involves setting up the reactor model, defining economic parameters, running simulations, and analyzing the results to make informed decisions. By combining advanced design calculations with detailed economic modeling, MOUSE provides a robust framework for optimizing nuclear microreactor technologies, enhancing their competitiveness, and guiding stakeholders towards innovative and cost-effective solutions.

Hanna, Botros [Idaho National Laboratory (INL), Id↗

SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

60 APPLIED LIFE SCIENCES↗

X-Band CubeSat Communication System Demonstration

Today's CubeSats mostly operate their communications at UHF- and S-band frequencies. UHF band is presently crowded, thus downlink communications are at lower data rates due to bandwidth limitations and are unreliable due to interference. This research presents an end-to-end robust, innovative, compact, efficient and low cost S-band uplink and X-band downlink CubeSat communication system demonstration between a balloon and a Near Earth Network (NEN) ground system. Since communication systems serve as umbilical cords for space missions, demonstration of this X-band communication system is critical for successfully supporting current and future CubeSat communication needs. This research has three main objectives. The first objective is to design, simulate, and test a CubeSat S- and X-band communication system. Satellite Tool Kit (STK) dynamic link budget calculations and HFSS Simulations and modeling results have been used to trade the merit of various designs for small satellite applications. S- and X-band antennas have been tested in the compact antenna test range at Goddard Space Flight Center (GSFC) to gather radiation pattern data. The second objective is simulate and test a CubeSat compatible X-band communication system at 12.5Mbps including S-band antennas, X-band antennas, Laboratory for Atmospheric and Space Physics (LASP) /GSFC transmitter and an S-band receiver from TRL-5 to TRL-8 by the end of this effort. Different X-band communication system components (antennas, diplexers, etc.) from GSFC, other NASA centers, universities, and private companies have been investigated and traded, and a complete component list for the communication system baseline has been developed by performing analytical and numerical analysis. This objective also includes running simulations and performing trades between different X-band antenna systems to optimize communication system performance. The final objective is to perform an end-to-end X-band CubeSat communication system demonstration between a balloon and/or a sounding rocket and a Near Earth Network (NEN) ground system. This paper presents CubeSat communication systems simulation results, analysis of X-band and S-band antennas and RF front-end components, transceiver design, analysis and optimization of space-to-ground communication performance, subsystem development, as well as the test results for an end-to-end X-band CubeSat communication system demonstration. The outcome of this work will be used to pave the way for next generation NEN-compatible X-band CubeSat communication systems to support higher data rates with more advanced modulation and forward error correction (FEC) coding schemes, and to support and attract new science missions at lower cost. It also includes an abbreviated concept of operations for CubeSat users to utilize the NEN, starting from first contact with NASA's communication network and continuing through on-orbit operations.

NEN↗

MO-FG-BRA-01: Development of An Image-Guided Dosimetric Planning System for Injectable Brachytherapy Using ELP Nanoparticles

Purpose: To develop, validate, and evaluate a methodology for determining dosimetry for intratumoral injections of elastin-like-polypeptide (ELP) brachytherapy nanoparticles. These organic-polymer-based nanoparticles are injectable, biodegradable, and genetically tunable. We present a genetically encoded polymer-solution, composed of novel radiolabeled-ELP nanoparticles that are custom-designed to self-assemble into a local source upon intratumoral injection. Our preliminary results of a small animal study demonstrate 100% tumor response, effective radionuclide retention-rates, strong in vivo stability, and no polymer-induced toxicities. While our approach is therefore highly promising for improved brachytherapy, the current workflow lacks a dosimetry framework. Methods: We are developing a robust software framework that provides image-guided dosimetric-planning capabilities for ELP brachytherapy. The user graphically places ELP injection sites within a µCT-planning-image, and independently defines each injection volume, concentration, and radioisotope to be used. The resulting internal dosimetry is then pre-determined by first modeling post-injection ELP advection-diffusion, and then calculating the resulting dose distribution based on a point- dose-kernel-convolution algorithm. We have experimentally measured ELP steady-state concentrations via µSPECT acquisition, and validated our dose calculation algorithm against Monte Carlo simulations of several radioactivity distributions. Finally, we have investigated potential advantages and limitations of various ELP injection parameters. Results: The µSPECT results demonstrated inhomogeneous steady-state distributions of ELP in tissue, and Monte Carlo radioactivity distributions were designed accordingly. Our algorithm yielded a root-mean-square-error of less than 2% for each distribution tested (average root-mean-square-error was 0.73%). Dose-Volume-Histogram analysis of five different plans showed how strategic injection placement, and an injection volume-tapering technique, could be used to achieve D95% target coverage. Conclusion: We have preliminarily developed a novel planning framework for ELP brachytherapy. Its dosimetry accuracy has been validated against Monte Carlo, and we have started to investigate the potential advantages of injection-based planning. This system, once fully developed, will serve as the technical foundation for our novel approach.

60 APPLIED LIFE SCIENCES↗

Launch Control System Software Development System Automation Testing

The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administration's (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This system requires high quality testing that will measure and test the capabilities of the system. For the past two years, the Exploration and Operations Division at Kennedy Space Center (KSC) has assigned a group including interns and full-time engineers to develop automated tests to save the project time and money. The team worked on automating the testing process for the SCCS GUI that would use streamed simulated data from the testing servers to produce data, plots, statuses, etc. to the GUI. The software used to develop automated tests included an automated testing framework and an automation library. The automated testing framework has a tabular-style syntax, which means the functionality of a line of code must have the appropriate number of tabs for the line to function as intended. The header section contains either paths to custom resources or the names of libraries being used. The automation library contains functionality to automate anything that appears on a desired screen with the use of image recognition software to detect and control GUI components. The data section contains any data values strictly created for the current testing file. The body section holds the tests that are being run. The function section can include any number of functions that may be used by the current testing file or any other file that resources it. The resources and body section are required for all test files; the data and function sections can be left empty if the data values and functions being used are from a resourced library or another file. To help equip the automation team with better tools, the Project Lead of the Automated Testing Team, Jason Kapusta, assigned the task to install and train an optical character recognition (OCR) tool to Brandon Echols, a fellow intern, and I. The purpose of the OCR tool is to analyze an image and find the coordinates of any group of text. Some issues that arose while installing the OCR tool included the absence of certain libraries needed to train the tool and an outdated software version. We eventually resolved the issues and successfully installed the OCR tool. Training the tool required many images and different fonts and sizes, but in the end the tool learned to accurately decipher the text in the images and their coordinates. The OCR tool produced a file that contained significant metadata for each section of text, but only the text and coordinates of the text was required for our purpose. The team made a script to parse the information we wanted from the OCR file to a different file that would be used by automation functions within the automated framework. Since a majority of development and testing for the automated test cases for the GUI in question has been done using live simulated data on the workstations at the Launch Control Center (LCC), a large amount of progress has been made. As of this writing, about 60% of all of automated testing has been implemented. Additionally, the OCR tool will help make our automated tests more robust due to the tool's text recognition being highly scalable to different text fonts and text sizes. Soon we will have the whole test system automated, allowing for more full-time engineers working on development projects.

Automation↗

Investigation of aerodynamic design issues with regions of separated flow

Existing aerodynamic design methods have generally concentrated on the optimization of airfoil or wing shapes to produce a minimum drag while satisfying some basic constraints such as lift, pitching moment, or thickness. Since the minimization of drag almost always precludes the existence of separated flow, the evaluation and validation of these design methods for their robustness and accuracy when separated flow is present has not been aggressively pursued. However, two new applications for these design tools may be expected to include separated flow and the issues of aerodynamic design with this feature must be addressed. The first application of the aerodynamic design tools is the design of airfoils or wings to provide an optimal performance over a wide range of flight conditions (multipoint design). While the definition of 'optimal performance' in the multipoint setting is currently being hashed out, it is recognized that given a wide range of flight conditions, it will not be possible to ensure a minimum drag constraint at all conditions, and in fact some amount of separated flow (presumably small) may have to be allowed at the more demanding flight conditions. Thus a multipoint design method must be tolerant of the existence of separated flow and may include some controls upon its extent. The second application is in the design of wings with extended high speed buffet boundaries of their flight envelopes. Buffet occurs on a wing when regions of flow separation have grown to the extent that their time varying pressures induce possible destructive effects upon the wing structure or adversely effect either the aircraft controllability or passenger comfort. A conservative approach to the expansion of the buffet flight boundary is to simply expand the flight envelope of nonseparated flow under the assumption that buffet will also thus be alleviated. However, having the ability to design a wing with separated flow and thus to control the location, extent and severity of the separated flow regions may allow aircraft manufacturers to gain an advantage in the early design stages of an aircraft, when configuration changes are relatively inexpensive to make. The goal of the summer research at NASA Langley Research Center (LaRC) was twofold: first, to investigate a particular airfoil design problem observed under conditions of strong shock induced flow separation on the upper surface of an airfoil at transonic conditions; and second, to suggest and investigate design methodologies for the prediction (or detection) and control of flow separation. The context of both investigations was to use an existing two dimensional Navier-Stokes flow solver and the constrained direct/iterative surface curvature (CDISC) design algorithm developed at LaRC. As a lead in to the primary task, it was necessary to gain a familiarity with both the design method and the computational analysis and to perform the FORTRAN coding needed to couple them together.

Gally, Tom↗

Scaling Input Distributions for Probabilistic Models - 19472

It is important to address scaling issues when building models to support risk-based decisions for radioactive waste disposal sites. Currently, probabilistic risk assessment and probabilistic performance assessment models are run for multiple realizations where each realization uses one value from each input distribution over the entire modeled time. The input distributions represent the current state of knowledge in the mean of the input variable over the spatial region of interest and over the time period of the model run. This paper focuses on the time factor in input distribution scaling because it presents more serious conceptual and distributional challenges than the spatial factor. One of the challenges in temporal scaling is the effect of non-linearity on propagation of distribution uncertainty through to uncertainty in results. Radioactive waste disposal models tend to have both linear and non-linear components in their models. Dose assessment calculations are typically represented by linear models, while contaminant transport models have linear and non-linear components. In principle, temporal scaling of input parameter distributions for a linear model is straightforward, but scaling of input distributions for non-linear models is not. This paper uses examples to investigate the effects of input distribution temporal scaling on simple linear and non-linear models. Different scaling scenarios were investigated by comparing three analysis tools: analytical mathematical representations, statistical software programming, and GoldSim Monte Carlo simulation software. R statistical software is an open source statistical programming language often used for statistical analyses and graphical representation of data. GoldSim is a robust probabilistic dynamic modeling platform used in performance assessment modeling of radioactive waste sites. A simple linear model, a quadratic model and a multiplicative model were the cases explored for each of these tools. For the three analysis tools considered and with each of the scaling cases, 1,000 realizations were implemented from distributions of the random variables of interest. This is a sufficient number of realizations for simple models to capture the model space. An annual temporal resolution of a 100-year simulation period was chosen for all models and analysis tools. The effects of temporal scaling were demonstrated by investigating two different options for time scaling. Option 1 was set up so that the input distributions represented the expected value on an annual time scale, and a new value from that distribution was chosen every year (at every time step which equaled a year) for 100 years. In Option 2, the input distributions were scaled to represent the expected mean value of the input variable over the 100 years of simulation, and one value from that distribution was chosen for the entire elapsed time. Results show agreement across the three analysis tools. As expected, the linear models have identical results for the two different scaling Options, and the non-linear models diverge in the results for different time scale implementation. The implications of this work point to the need for careful consideration of input distribution temporal scaling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

Verification of the DIF3D Software to Support Fast Reactor Analysis

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the polynomial order used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-490: Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing

Purpose: Dosimetric verification of VMAT/SBRT is currently performed on one or two planes in a phantom with either film or array detectors. A robust and easy-to-use 3D dosimetric tool has been sought since the advent of conformal radiation therapy. Here we present such a strategy for independent 3D VMAT/SBRT plan verification system by a combined use of EPID and cloud-based Monte Carlo (MC) dose calculation. Methods: The 3D dosimetric verification proceeds in two steps. First, the plan was delivered with a high resolution portable EPID mounted on the gantry, and the EPID-captured gantry-angle-resolved VMAT/SBRT field images were converted into fluence by using the EPID pixel response function derived from MC simulations. The fluence was resampled and used as the input for an in-house developed Amazon cloud-based MC software to reconstruct the 3D dose distribution. The accuracy of the developed 3D dosimetric tool was assessed using a Delta4 phantom with various field sizes (square, circular, rectangular, and irregular MLC fields) and different patient cases. The method was applied to validate VMAT/SBRT plans using WFF and FFF photon beams (Varian TrueBeam STX). Results: It was found that the proposed method yielded results consistent with the Delta4 measurements. For points on the two detector planes, a good agreement within 1.5% were found for all the testing fields. Patient VMAT/SBRT plan studies revealed similar level of accuracy: an average γ-index passing rate of 99.2± 0.6% (3mm/3%), 97.4± 2.4% (2mm/2%), and 72.6± 8.4 % ( 1mm/1%). Conclusion: A valuable 3D dosimetric verification strategy has been developed for VMAT/SBRT plan validation. The technique provides a viable solution for a number of intractable dosimetry problems, such as small fields and plans with high dose gradient.

60 APPLIED LIFE SCIENCES↗

PRIMA-X - Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing

The PRIMA-X (Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing) project is the successor of the DOE PRIMA (Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing) project, which addressed the challenge of creating a core measurement infrastructure that would serve as a common platform for both integrating leading parallel performance systems (notably TAU and Scalasca) and developing next-generation scalable performance tools. The PRIMA-X project shifts the focus away from refactorization of robust performance tools towards a re-targeting of the parallel performance measurement and analysis architecture for extreme scales. The massive concurrency, asynchronous execution dynamics, hardware heterogeneity, and multi-objective prerequisites (performance, power, resilience) that identify exascale systems introduce fundamental constraints on the ability to carry forward existing performance methodologies. In particular, there must be a deemphasis of per-thread observation techniques to significantly reduce the otherwise unsustainable flood of redundant performance data. Instead, it will be necessary to assimilate multi-level resource observations into macroscopic performance views, from which resilient performance metrics can be attributed to the computational features of the application. This requires a scalable framework for node-level and system-wide monitoring and runtime analyses of dynamic performance information. Also, the interest in optimizing parallelism parameters with respect to performance and energy drives the integration of tool capabilities in the exascale environment further. Initially, PRIMA-X was a collaborative project between the University of Oregon (lead institution) and the German Research School for Simulation Sciences (GRS). Because Prof. Wolf, the PI at GRS, accepted a position as full professor at Technische Universitaet Darmstadt (TU Darmstadt) starting February 1st, 2015, the work of GRS was continued at TU Darmstadt. This report covers the work at TU Darmstadt after the transition. The first main accomplishment of TU Darmstadt is the development of different techniques to aggregate performance data on the level of threads. TU Darmstadt evaluated different schemes designed at GRS during the first phase of this project and integrated them into Score-P, a widely used performance measurement framework for HPC applications. The second main accomplishment is a substantial increase of Score-P’s scalability, achieved by improving its internal representation of the underlying system. Third, we extended our performance-modeling tool Extra-P to automatically create models with more than one input parameter (e.g., process count and input size), which was previously impossible. These models allow the performance behavior of an application to be extrapolated to larger machines. Specific applications of the new multi-parameter capability realized in this project include modeling the isoefficiency function of task-based applications and a novel co-design methodology. Further extensions of Extra-P comprise online modeling functionality, automatic refinement of the model search space, and segmented performance modeling. Further contributions include new locality metrics for both shared- and distributed-memory applications, a new way of measuring the impact of inter-application inference on the execution time of an application, and finally an automatic method that selects appropriate OpenMP constructs for the parallelization of sequential code and classifies the affected variables based on their sharing semantics.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-150: Brachytherapy QA Employing a High Resolution Liquid Filled Ionisation Chamber Array: Initial Experience and Limitations

Purpose: Verifying a complex 3D brachytherapy dose distribution by measurement is non-trivial. Ideally a photon detector array should be independent of energy and angle, have high spatial resolution and be robust for routine clinical use. Methods: An iridium-192 source was used. A PMMA jig was constructed comprising an outer slab and a central insert with eight milled channels for 1.33mm (outer diameter) steel needles, see figure. All calculations were performed using an empty CT study reconstructing eight virtual needles (QA-CT), using the v2 source model (Elekta AG, Sweden). A high resolution liquid filled ionisation chamber array SRS1000, together with Verisoft software v6.0 (PTW Freiburg, Germany), was used to perform measurements of plans of increasing complexity to evaluate its suitability for device- and patient-specific QA. The dimension of backscatter material was investigated. The patient plan dwell time distribution was entered manually into the QA-CT and the dose distribution was calculated. Results: Our measurements indicate that the array is independent of energy and angle. The resulting measured dose values are linearly interpolated to 2025 values. Shifts of 1mm of the entire needle are readily detectable. Individual dwell position shifts (2.5mm) are also readily measurable. Moreover a dwell time increase of 1 second both in the edge and central region are detectable. Conclusion: The high resolution SRS1000 array is a powerful instrument for brachytherapy QA enabling 977 simultaneous measurements to be performed. Our measurements suggest 60mm of RW3 backscatter material upstream and downstream are sufficient. Local percentage difference analysis is useful for device based QA, normalized relative percentage difference is arguably better for patient specific QA. Automated transfer of patient plan dwell time distribution to the QA plan is required to enable a comprehensive patient QA study to be performed. Moreover the described measurement technique can be used for commissioning new brachytherapy applicators.

60 APPLIED LIFE SCIENCES↗

A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy

Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into different failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.

60 APPLIED LIFE SCIENCES↗

Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71.27 ± 17.52 (mm), 61.59 ± 16.98 (mm), 0.01 ± 0.00 (mm{sup −1}), and 34 380.75 ± 6680.06 (mm{sup 2}), respectively. Several parameters were correlated with the PFT parameters. Conclusions: The authors propose an automatic method for quantitatively evaluating the morphological parameters of the diaphragm on volumetric chest CT in COPD patients. By measuring not only the conventional length and surface area but also the shape features of the diaphragm using quadratic 3D surface modeling, the proposed method is especially useful for quantifying diaphragm characteristics. Their method may be useful for assessing morphological diaphragmatic changes in COPD patients.

60 APPLIED LIFE SCIENCES↗

Verification of the DIF3D Software to Support Fast Reactor Analysis

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. As some additional changes have been made to the ARC software since this point all versions between release 3012 and 3266 can be considered verified as version 3253 was used for all updates in this revision. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the methodology used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative noting that DIF3D will properly notify the user when the peaking values it is providing are potentially incorrect.

97 MATHEMATICS AND COMPUTING↗

Verification of the DIF3D Software to Support Fast Reactor Analysis (Rev. 3)

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. As some additional changes have been made to the ARC software since this point all versions between release 3012 and 3266 can be considered verified as version 3253 was used for all updates in this revision. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the methodology used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative noting that DIF3D will properly notify the user when the peaking values it is providing are potentially incorrect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing fast and automatic segmentation of the prostate. Funding Support, Disclosures, and Conflict of Interest: AS Nelson is a partial owner of MIM Software, Inc. AS Nelson, and A Swallen are current employees at MIM Software, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigated for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.

60 APPLIED LIFE SCIENCES↗