Cryogenic User Facilities for R&D on Noble Liquid Detectors and Low Temperature Devices

Cryogenic test facilities are critical infrastructure for physics experiments in a variety of fields, perhaps most notably for particle detection with noble liquid detectors, low-temperature device development, and quantum information research. However, considerable investment and technical knowledge are required to construct and operate such facilities. This white paper discusses proposals for user facilities aimed at broadening the availability of testing capabilities for the scientific community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NO{nu}A Detector Research and Development

The NuMI Off-axis {nu}{sub e} Appearance (NO{nu}A) experiment is a second generation long-baseline, accelerator-based neutrino oscillation experiment that will search for the as-yet unobserved {nu}{sub {mu}}{yields}{nu}{sub e} transition. Two functionally identical detectors will be placed 14.6 mrad off-axis of the central NuMI beam, one located near the NuMI beam source at FNAL, and one located 810 km away in northern Minnesota. We describe the basic design and status of the research and development of the NO{nu}A detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle Dark Matter and DAMA/LIBRA

The DAMA/LIBRA set-up (about 250 kg highly radiopure NaI(Tl) sensitive mass) is running at the Gran Sasso National Laboratory of the I.N.F.N.. The first DAMA/LIBRA results confirm the evidence for the presence of a Dark Matter particle component in the galactic halo, as pointed out by the former DAMA/NaI set-up; cumulatively the data support such evidence at 8.2 sigma C.L. and satisfy all the many peculiarities of the Dark Matter annual modulation signature. The main aspects and prospects of this model independent experimental approach will be outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALICE upgrades during the LHC Long Shutdown 2

A Large Ion Collider Experiment (ALICE) has been conceived and constructed as a heavy-ion experiment at the LHC. During LHC Runs 1 and 2, it has produced a wide range of physics results using all collision systems available at the LHC. In order to best exploit new physics opportunities opening up with the upgraded LHC and new detector technologies, the experiment has undergone a major upgrade during the LHC Long Shutdown 2 (2019–2022). This comprises the move to continuous readout, the complete overhaul of core detectors, as well as a new online event processing farm with a redesigned online-offline software framework. These improvements will allow to record Pb-Pb collisions at rates up to 50 kHz, while ensuring sensitivity for signals without a triggerable signature.

47 OTHER INSTRUMENTATION↗

Beyond the Standard Model New Physics Searches with SBND

SBND (Short-Baseline Near Detector) is a 112-ton liquid argon time projection chamber located on the Booster Neutrino Beam at Fermi National Accelerator Laboratory, and is the near detector of the Short-Baseline Neutrino program. The primary goals of SBND are to provide flux constraints for sterile neutrino searches, conduct world-leading neutrino cross-section measurements on argon, and perform Beyond the Standard Model (BSM) new physics searches with its high-precision particle identification capabilities. SBND’s prospects and tools for detecting a variety of BSM phenomena produced in a neutrino beam, such as sub-GeV dark matter, dark neutrinos, heavy neutral leptons and millicharged particles, are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ICARUS at the Short-Baseline Neutrino Program: First Results

The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory. In 2021, ICARUS started its new operation at Fermilab, collecting a substantial amount of neutrino events from the Booster Neutrino Beam (BNB) and the neutrinos at the Main Injector (NuMI) beam off-axis. These were used to test the ICARUS event selection, reconstruction, and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by the Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurements of neutrino cross sections in LAr with the NuMI beam and several Beyond Standard Model studies. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this work, preliminary results from the ICARUS data with the BNB and NuMI beams are presented, both in terms of the performance of all ICARUS subsystems and the capability to select and reconstruct neutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic Ray Muons Timing in the ATLAS Detector

In this talk I discuss the use of calorimeter timing both for detector commissioning and in searches for new physics. In particular I present real and simulated cosmic ray muons data (2007) results for the ATLAS Tile Calorimeter system. The analysis shows that several detector errors such as imperfect calibrations can be uncovered. I also demonstrate the use of ATLAS Tile Calorimeter's excellent timing resolution in suppressing cosmic ray fake missing transverse energy (E{sub T}) in searches for supersymmetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Denoising diffusion models with geometry adaptation for high fidelity calorimeter simulation

Simulation is crucial for all aspects of collider data analysis, but the available computing budget in the High Luminosity LHC era will be severely constrained. Generative machine learning models may act as surrogates to replace physics-based full simulation of particle detectors, and diffusion models have recently emerged as the state of the art for other generative tasks. Here, we introduce CaloDiffusion, a denoising diffusion model trained on the public CaloChallenge datasets to generate calorimeter showers. Our algorithm employs 3D cylindrical convolutions, which take advantage of symmetries of the underlying data representation. To handle irregular detector geometries, we augment the diffusion model with a new geometry latent mapping (GLaM) layer to learn forward and reverse transformations to a regular geometry that is suitable for cylindrical convolutions. The showers generated by our approach are nearly indistinguishable from the full simulation, as measured by several different metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Track vs Shower Discrimination in the Event Reconstruction of the ICARUS Experiment

The ICARUS collaboration has employed the 760-ton T600 liquid argon TPC detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. The detector commissioning phase lasted until June 2022, then ICARUS moved to data taking for neutrino oscillation physics collecting events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis. The initial experiment goals are to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment, perform measurements of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. Then, ICARUS will jointly search for evidence of sterile neutrinos with the Short-Baseline Near Detector (SBND). In this contribution, we discuss recent changes to the standard TPC event reconstruction that uses Pandora, a pattern recognition software common to liquid argon-based detectors. In particular, we performed a new training of the Boosted Decision Tree (BDT) employed to separate track-like and shower-like reconstructed particles using Monte Carlo simulations of neutrino events from BNB in ICARUS. We compare the discrimination capabilities of the old and new BDT training and discuss further improvements of this algorithm.

43 PARTICLE ACCELERATORS↗

Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: i) Argon Purity and Cryogenics, ii) TPC and High Voltage, iii) Electronics, Data Acquisition and Triggering, iv) Scintillation Light Detection, v) Calibration and Test Beams, and vi) Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment↗

A vertically integrated pixel readout device for the Vertex Detector at the International Linear Collider

3D-Integrated Circuit technology enables higher densities of electronic circuitry per unit area without the use of nanoscale processes. It is advantageous for mixed mode design with precise analog circuitry because processes with conservative feature sizes typically present lower process dispersions and tolerate higher power supply voltages, resulting in larger separation of a signal from the noise floor. Heterogeneous wafers (different foundries or different process families) may be combined with some 3D integration methods, leading to the optimization of each tier in the 3D stack. Tracking and vertexing in future High-Energy Physics (HEP) experiments involves construction of detectors composed of up to a few billions of channels. Readout electronics must record the position and time of each measurement with the highest achievable precision. This paper reviews a prototype of the first 3D readout chip for HEP, designed for a vertex detector at the International Linear Collider. The prototype features 20 x 20 {micro}m{sup 2} pixels, laid out in an array of 64 x 64 elements and was fabricated in a 3-tier 0.18 {micro}m Fully Depleted SOI CMOS process at MIT-Lincoln Laboratory. The tests showed correct functional operation of the structure. The chip performs a zero-suppressed readout. Successive submissions are planned in a commercial 3D bulk 0.13 {micro}m CMOS process to overcome some of the disadvantages of an FDSOI process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Dark Matter Search with MALBEK

The Majorana Demonstrator is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the Majorana research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is potentially sensitive to non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and present results from a WIMP search with 221.49 live days of data from this detector.

Giovanetti, G. K.↗

Nb$_3$Sn Superconducting Radiofrequency Cavities: a Maturing Technology for Particle Accelerators and Detectors

Nb3Sn superconducting radiofrequency (SRF) cavities have substantial potential for enabling new performance capabilities for particle accelerators for high energy physics (HEP), as well as for RF cavity-based detectors for dark matter, gravitational waves, and other quantum sensing applications. Outside of HEP, Nb3Sn SRF cavities can also benefit accelerators for nuclear physics, basic energy sciences, and the industry. In this contribution to Snowmass 2021, we overview the potential, status, and outlook of Nb3Sn SRF cavities.

43 PARTICLE ACCELERATORS↗

Resolving Wave-Particle Duality Could Accelerate the Mass Production of Quantum Computers

Quantum computers, hypothesized in 1980s, use concepts of superposition and entanglement phenomena. Although theoretical propositions and associated search algorithms for accurate measurements are being generated, the development of practical quantum computers themselves are advancing very slowly requiring enormous time and investments. The underlying concepts of a quantum computer are not new to the optical domain. However, the crucial enabling concepts of Entanglement and Superposition Principle are remaining clouded under the unresolved postulates, Wave-Particle Duality (WPD), and Wave Packet Reduction (WPR), implicating incompleteness in the interpretations of the mathematical formalism behind Quantum Mechanics. The WPD debate started during late1600 between Newton and Huygens. Young’s resolution of WPD through his double-slit experiment in 1802 was effectively overturned by Einstein’s interpretation of photoelectric effect as due to “indivisible light quanta”. However, Einstein disowned his “light quanta” postulate shortly before his death in1955, even though it had earned him the Nobel Prize. We resolve WPD by synthesizing Newton’s and Maxwell’s concepts and assume atoms do emit quanta but propagate as time-finite exponential pulses. This assumption also resolves WPR for light-matter interaction with the assumption that Schrodinger’s ψ represents atom’s internal dipolar amplitude stimulations. This over-turns Born’s interpretation that ψ only represents the abstract mathematical probability amplitude, rather than the physical “internal amplitude stimulation” of the quantum entity. However, our concept of atomic pulse emission forces us to re-derive the expression for the N-slit grating-spectrometer response since the classical derivation uses CW light, which does not exist. This pulsespectrometric response function strengthens our postulate since the grating response to the exponential pulse appears to be the convolution of a Lorentzian spectrum with the classical CW response function of the grating. The Fourier Transform of an exponential function is Lorentzian and QM predicts spontaneous emission line width to be Lorentzian. Then, conceptually one can extend the grating-expression (with N=2) to get the double-slit pattern. This approach preserves the classical causality that each of the two slits, like the N-signals out of a grating, are physically real and jointly stimulate the quantum detector array at the far field to generate the “Local” cosine fringes. The detector array executes the square modulus operation on its imposed dipolar amplitude stimulation and absorbs the necessary energy to fill up their quantum cups. Hence the double-slit pattern must also be “Local”, just as the N-slit grating spectrum is generated locally at the exit spectral-plane of the spectrometer. This removes the need to believe that “single photons” mysteriously generate the double slit pattern. Quantum computers, hypothesized in 1980s, use concepts of superposition and entanglement phenomena. Although theoretical propositions and associated search algorithms for accurate measurements are being generated, the development of practical quantum computers themselves are advancing very slowly requiring enormous time and investments. The underlying concepts of a quantum computer are not new to the optical domain. However, the crucial enabling concepts of Entanglement and Superposition Principle are remaining clouded under the unresolved postulates, Wave-Particle Duality (WPD), and Wave Packet Reduction (WPR), implicating incompleteness in the interpretations of the mathematical formalism behind Quantum Mechanics. The WPD debate started during late1600 between Newton and Huygens. Young’s resolution of WPD through his double-slit experiment in 1802 was effectively overturned by Einstein’s interpretation of photoelectric effect as due to “indivisible light quanta”. However, Einstein disowned his “light quanta” postulate shortly before his death in1955, even though it had earned him the Nobel Prize. We resolve WPD by synthesizing Newton’s and Maxwell’s concepts and assume atoms do emit quanta but propagate as time-finite exponential pulses. This assumption also resolves WPR for light-matter interaction with the assumption that Schrodinger’s ψ represents atom’s internal dipolar amplitude stimulations. This over-turns Born’s interpretation that ψ only represents the abstract mathematical probability amplitude, rather than the physical “internal amplitude stimulation” of the quantum entity. However, our concept of atomic pulse emission forces us to re-derive the expression for the N-slit grating-spectrometer response since the classical derivation uses CW light, which does not exist. This pulsespectrometric response function strengthens our postulate since the grating response to the exponential pulse appears to be the convolution of a Lorentzian spectrum with the classical CW response function of the grating. The Fourier Transform of an exponential function is Lorentzian and QM predicts spontaneous emission line width to be Lorentzian. Then, conceptually one can extend the grating-expression (with N=2) to get the double-slit pattern. This approach preserves the classical causality that each of the two slits, like the N-signals out of a grating, are physically real and jointly stimulate the quantum detector array at the far field to generate the “Local” cosine fringes. The detector array executes the square modulus operation on its imposed dipolar amplitude stimulation and absorbs the necessary energy to fill up their quantum cups. Hence the double-slit pattern must also be “Local”, just as the N-slit grating spectrum is generated locally at the exit spectral-plane of the spectrometer. This removes the need to believe that “single photons” mysteriously generate the double slit pattern.

Quantum Computer↗

Overview of the Liquid Argon Cryogenics for the Short Baseline Neutrino Program (SBN) at Fermilab

The Short-Baseline Neutrino (SBN) physics program will involve three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-scale through both appearance and disappearance oscillation channels. The Program will be composed of an existing and operational detector known as Micro Boone (170 ton LAr mass) plus two new experiments known as the SBN Near Detector (SBND, ~ 260 ton) and the SBN Far Detector (SBN-FD, ~ 600 tons). Fermilab is now building two new facilities to house the experiments and incorporate all cryogenic and process systems to operate these detectors beginning in the 2018-2019 time frame. The SBN cryogenics are a collaborative effort between Fermilab and CERN. The SBN cryogenic systems for both detectors are composed of several sub-systems: External/Infrastructure (or LN2), Proximity (or LAr), and internal cryogenics. For each detector the External/Infrastructure cryogenics includes the equipment used to store and the cryogenic fluids needed for the operation of the Proximity cryogenics, including the LN2 and LAr storage facilities. The Proximity cryogenics consists of all the systems that take the cryogenic fluids from the external/infrastructure cryogenics and deliver them to the internal at the required pressure, temperature, purity and mass flow rate. It includes the condensers, the LAr and GAr purification systems, the LN2 and LAr phase separators, and the interconnecting piping. The Internal cryogenics is comprised of all the cryogenic equipment located within the cryostats themselves, including the GAr and LAr distribution piping and the piping required to cool down the cryostats and the detectors. These cryogenic systems will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution presents the performance, the functional requirements and the modes of operation of the SBN cryogenics, and details the current status of the design, present and future needs.

Norris, Barry↗

Parameterization of electron attachment rate constants for impurities in LArTPC detectors

The ability of free electrons to drift long distances at high velocities in pure liquid argon under an applied electric field has been exploited for the past forty years to implement detectors with increasingly larger volumes for high energy physics research. The attachment of free electrons to impurities in the LAr is an important limit on the free instrumented volume of these extremely large detectors, and impurity concentrations as small as 100 ppt can reduce their resolution and efficiency. In this paper, we summarize the electron attachment rate constants as a function of the applied electric field, for common impurities in LArTPCs, obtained from data in the literature. Here, we further provide analytical functions to parameterize the data, which are useful to compare with new measurements, to model and analyze the performance of existing detectors, and to predict the performance of new detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗