Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diameter effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Maximum expiratory flow-volume curves during short periods of microgravity

Nine normal subjects were studied in a NASA microgravity research aircraft to elucidate the effect of normal gravitation on the shape of the maximum expiratory flow-volume (MEFV). They performed multiple MEFV maneuvers at 0, 1, and approximately 2 G. The MEFV curves for each subject were filtered, aligned at residual volume, and ensemble-averaged to produce an average MEFV curve for each state, allowing differences to be studied. Most subjects showed a decrease in the forced vital capacity at 0 G. The mean lung volume associated with a given flow was lower at 0 G over about the upper half of the vital capacity. There were consistent but highly individual changes in the position and magnitude of detailed features of the curve. This supports the concept that the location and motion of choke points that determine the detailed individual configuration of MEFG curves can be significantly influenced by gravitational forces, presumably via the effects of change in longitudinal tension on local airway pressure-diameter behavior and thus wave speed.

Guy, H. J. B.↗

Internal structure of shock waves in disparate mass mixtures

The detailed flow structure of a normal shock wave for a gas mixture is investigated using the direct-simulation Monte Carlo method. A variable diameter hard-sphere (VDHS) model is employed to investigate the effect of different viscosity temperature exponents (VTE) for each species in a gas mixture. Special attention is paid to the irregular behavior in the density profiles which was previously observed in a helium-xenon experiment. It is shown that the VTE can have substantial effects in the prediction of the structure of shock waves. The variable hard-sphere model of Bird shows good agreement, but with some limitations, with the experimental data if a common VTE is chosen properly for each case. The VDHS model shows better agreement with the experimental data without adjusting the VTE. The irregular behavior of the light-gas component in shock waves of disparate mass mixtures is observed not only in the density profile, but also in the parallel temperature profile. The strength of the shock wave, the type of molecular interactions, and the mole fraction of heavy species have substantial effects on the existence and structure of the irregularities.

Chung, Chan-Hong↗

Pulmonary function in microgravity: KC-135 experience

We have commenced a KC-135 program that parallels and proceeds our Spacelab (SLS-1) pulmonary function experiment. Our first task was to elucidate the affect of normal gravitation on the shape of the maximum expiratory flow volume (MEFV) curve. Nine normal subjects performed multiple MEFV maneuvers at 0-G, 1-G, and approximately 1.7-G. The MEFV curves for each subject were filtered, aligned at RV, and ensemble-averaged to produce an average MEFV curve for each state, allowing differences to be studied. Most subjects showed a decrease in the FVC at 0-G, which we attribute to an increased intrathoracic blood volume. In most of these subjects, the mean lung volume associated with a given flow was lower at 0-G, over about the upper half of the vital capacity. This is similar to the change previously reported during heat out immersion and is consistent with the known affect of engorgement of the lung with blood, on elastic recoil. There were also consistent but highly individual changes in the position and magnitude of detailed features of the curve, the individual patterns being similar to those previously reported on transition from the erect to the supine position. This supports the idea that the location and motion of choke points which determine the detailed individual configuration of MEFV curves, can be significantly influenced by gravitational forces, presumably via the effects of change in longitudinal tension on local airway pressure-diameter behavior and wave speed. We have developed a flight mass spectrometer and have commenced a study of single breath gradients in gas exchange, inert gas washouts, and rebreathing cardiac outputs and lung volumes at 0-G, 1-G, and 1.7-G. Comparison of our results with those from SLS-1 should identify the opportunities and limitations of the KC-135 as an accessible microgravity resource.

Guy, Harold J.↗

Soot Aerosol Properties in Laminar Soot-Emitting Microgravity Nonpremixed Flames

The 0-g flame soot measurements reported in previous studies are extended by adding new 0-g data for different fuel flow rates and burner diameters. The new flame conditions allow more conclusive comparisons regarding the effect of characteristic flow residence times on soot field structure, the influence of fuel preheat on fuel pyrolysis rates near the flame centerline, and the premature cessation of soot growth along the soot annulus in 0-g when the fuel is preheated. The paper also reports on the implementation of thermophoretic soot sampling in a specific 0-g flame featuring burner exit velocities typical of buoyant flames and presents quantitative data on the radial variation of soot microstructure at a fixed height above the burner mouth.

FLAME STRUCTURE↗

Altitude-Wind-Tunnel Investigation of a 4000-Pound-Thrust Axial-Flow Turbojet Engine: Analysis of Turbine Performance - 5

Performance characteristics of the turbine of a 4000-pound-thrust axial-flow turbojet engine was determined in investigations of the complete engine in the NACA Cleveland altitude wind tunnel. Characteristics are presented as functions of the total-pressure ratio across the turbine and of turbine speed and gas flow corrected to sea-level conditions. Three turbine nozzles of different areas were used to determine the area that gave optimum performance. Inasmuch as tail-pipe nozzles of different diameters were investigated in combination with the standard turbine nozzle, the effect of varying discharge conditions on turbine operation could be observed. The investigations covered a range of pressure attitudes from 5000 to 40,000 feet. The engine was investigated over the entire operable range of speeds at each altitude. At pressure altitude of 30,000 feet, the effect on turbine operation of varying the ram pressure ration over a range from 1.10 to 1.77 was evaluated. An altitude effect was apparent when turbine pressure ratio was plotted against corrected turbine speed but it was so slight as to be negligible insofar as the turbine efficiencies were concerned. A maximum turbine efficiency of slightly more than 82 percent was obtained with the configuration using the standard turbine nozzle and the low-flow compressor. This efficiency, which is somewhat lower than the actual turbine efficiency, is uncorrected for accessories drive power, bearing friction, tail-pipe pressure drop, compressor thermal radiation, and introduction of turbine-disk cooling air into the gas stream. Changes in the ram pressure ratio had a negligible effect on the turbine efficiency.

Krebs, Richard P.↗

Metrology System for a Large, Somewhat Flexible Telescope

A proposed metrology system would be incorporated into a proposed telescope that would include focusing optics on a rigid bench connected via a deployable mast to another rigid bench holding a focal-plane array of photon counting photodetectors. Deformations of the deployable mast would give rise to optical misalignments that would alter the directions (and, hence, locations) of incidence of photons on the focal plane. The metrology system would measure the relative displacement of the focusing- optics bench and the focal-plane array bench. The measurement data would be used in post-processing of the digitized photodetector outputs to compensate for the mast-deformation-induced changes in the locations of incidence of photons on the focal plane, thereby making it possible to determine the original directions of incidence of photons with greater accuracy. The proposed metrology system is designed specifically for the Nuclear Spectroscopic Telescope Array (NuSTAR) a proposed spaceborne x-ray telescope. The basic principles of design and operation are also applicable to other large, somewhat flexible telescopes, both terrestrial and spaceborne. In the NuSTAR, the structural member connecting the optical bench and the photodetector array would be a 10-m-long deployable mast, and there is a requirement to keep errors in measured directions of incidence of photons below 10 arc seconds (3 sigma). The proposed system would include three diode lasers that would be mounted on the focusing-optics bench. For clarity, only one laser is shown in the figure, which is a greatly simplified schematic diagram of the system. Each laser would be aimed at a position-sensitive photodiode that would be mounted on the detector bench alongside the aforementioned telescope photodetector array. The diode lasers would operate at a wavelength of 830 nm, each at a power of 200 mW. Each laser beam would be focused to a spot of .1-mm diameter on the corresponding position-sensitive photodiode. To reduce the effect of sunlight on the measurements, a one-stage light baffle and an 830-nm transmission filter of 10-nm bandwidth would be placed in front of the position- sensitive photodiode. For each metrology reading, the output of the position-sensitive detector would be sampled and digitized twice: once with the lasers turned on, then once with the lasers turned off. The data from these two sets of samples would be subtracted from each other to further reduce the effects of sun glints or other background light sources.

Liebe, Carl Christian↗

Improved Thermoplastic/Iron-Particle Transformer Cores

A method of fabricating improved transformer cores from composites of thermoplastic matrices and iron-particles has been invented. Relative to commercially available laminated-iron-alloy transformer cores, the cores fabricated by this method weigh less and are less expensive. Relative to prior polymer-matrix/ iron-particle composite-material transformer cores, the cores fabricated by this method can be made mechanically stronger and more magnetically permeable. In addition, whereas some prior cores have exhibited significant eddy-current losses, the cores fabricated by this method exhibit very small eddy-current losses. The cores made by this method can be expected to be attractive for use in diverse applications, including high-signal-to-noise transformers, stepping motors, and high-frequency ignition coils. The present method is a product of an experimental study of the relationships among fabrication conditions, final densities of iron particles, and mechanical and electromagnetic properties of fabricated cores. Among the fabrication conditions investigated were molding pressures (83, 104, and 131 MPa), and molding temperatures (250, 300, and 350 C). Each block of core material was made by uniaxial-compression molding, at the applicable pressure/temperature combination, of a mixture of 2 weight percent of LaRC (or equivalent high-temperature soluble thermoplastic adhesive) with 98 weight percent of approximately spherical iron particles having diameters in the micron range. Each molded block was cut into square cross-section rods that were used as core specimens in mechanical and electromagnetic tests. Some of the core specimens were annealed at 900 C and cooled slowly before testing. For comparison, a low-carbon-steel core was also tested. The results of the tests showed that density, hardness, and rupture strength generally increased with molding pressure and temperature, though the correlation was rather weak. The weakness of the correlation was attributed to the pores in the specimens. The maximum relative permeabilities of cores made without annealing ranged from 30 to 110, while those of cores made with annealing ranged from 900 to 1,400. However, the greater permeabilities of the annealed specimens were not associated with noticeably greater densities. The major practical result of the investigation was the discovery of an optimum distribution of iron-particle sizes: It was found that eddy-current losses in the molded cores were minimized by using 100 mesh (corresponding to particles with diameters less than or equal to 100 m) iron particles. The effect of optimization of particle sizes on eddy-current losses is depicted in the figure.

Wincheski, Russell A.↗

High Ballistic Coefficient Mars EDL with Supersonic Retropropulsion

Future Mars missions will require the ability to land increasingly heavy systems with high precision, possibly at high altitude landing sites. A key obstacle in landing systems with high ballistic coefficient is Mars’ very thin atmosphere, approximately one hundred times less dense than Earth’s atmosphere. As a result, hypersonic deceleration occurs slowly throughout atmospheric entry and additional deceleration methods are required before landing. Previous landers up to and including MSL relied on Viking-heritage technologies including a Disk-Gap-Band (DGB) supersonic parachute and a blunt body aeroshell. Safe and effective deployment of a DGB parachute can be accomplished only within prescribed bounds on dynamic pressure and Mach number.2 In addition to the restrictive constraint this imposes on the entry trajectory, there is a concern that for a parachute to effectively slow an entry vehicle with a high ballistic coefficient, its diameter must be large enough to impose certification costs, modeling uncertainty, or mission risk that could be unacceptable. This has prompted investigation into alternative mission concepts based on use of supersonic retropropulsion (SRP) without a parachute. This work investigates SRP as an enabling technology for Mars EDL of high ballistic coefficient vehicles.

Noyes, Connor↗

Retrieval of Snow Water Equivalent by the Precipitation Imaging Package (PIP) over Northern Great Lakes

Performance of the Precipitation Imaging Package (PIP) for estimating the snow water equivalent (SWE) is evaluated through a comparative study with the collocated National Oceanic and Atmospheric Administration National Weather Service snow stake field measurements. The PIP together with a vertically pointing radar, a weighing bucket gauge, and a laser-optical disdrometer was deployed at the NWS Marquette, Michigan office building for a long-term field study supported by the National Aeronautics and Space Administration’s Global Precipitation Measurement mission Ground Validation program. The site was also equipped with a weather station. During the 2017-18 winter, PIP functioned nearly uninterrupted at frigid temperatures accumulating 2345.8 mm of geometric snow depth over a total of 499 hours. This long record consists of 30 events, and the PIP-retrieved and snow stake field measured SWE differed less than 15% in every event. For the windy events, the wind corrected stake field record agreed better with the PIP-retrieved SWE. Two of the major events with the longest duration and the highest accumulation are examined in detail. The particle mass with a given diameter was much lower during a shallow, colder, uniform lake-effect event than in the deep, less cold, and variable synoptic event. This study demonstrated that PIP is a robust instrument for operational use, and is reliable for deriving the bulk properties of falling snow.

Ali Tokay↗

New HOM coupler design for high current SRF cavity

Damping higher order modes (HOMs) significantly to avoid beam instability is a challenge for the high current Energy Recovery Linac-based eRHIC at BNL. To avoid the overheating effect and high tuning sensitivity, current, a new band-stop HOM coupler is being designed at BNL. The new HOM coupler has a bandwidth of tens of MHz to reject the fundamental mode, which will avoid overheating due to fundamental frequency shifting because of cooling down. In addition, the S21 parameter of the band-pass filter is nearly flat from first higher order mode to 5 times the fundamental frequency. The simulation results showed that the new couplers effectively damp HOMs for the eRHIC cavity with enlarged beam tube diameter and 2 120{sup o} HOM couplers at each side of cavity. This paper presents the design of HOM coupler, HOM damping capacity for eRHIC cavity and prototype test results.

43 PARTICLE ACCELERATORS↗

Dry coupled magnetostrictive transducers for robotic inspection of dry storage casks - 15304

The lack of a national repository for used nuclear fuel has lead to the usage of dry storage casks as the de facto long term storage solution, the usage of which is prevalent throughout the United States. Furthermore, as shown in figure 3, the usage of dry storage is only expected to increase over time. Because these casks were originally intended as only an interim measure, there is an urgent need to develop methods to monitor their structural health over the long-term. Additionally, when concerns about the susceptibility of these casks to cracking is considered, the need for inspection becomes even more apparent. The use of robotic devices to inspect the interior of these casks for signs of damage has been proposed, but in order for this to be realized, advances in sensing technology must occur. We develop a novel type of transducer for non-destructive evaluation to aid in these efforts. We construct a prototype sensor, demonstrate simple defect detection with it, and present a design for an inspection robot equipping these transducers. Ultrasonic inspection is a well known method of non-destructive evaluation which works by measuring the response of ultrasonic waves propagating through a material. In through-transmission inspection, a transmitter and receiver are used to generate and detect waves in the material to be inspected. The presence of a crack or defect in the material will scatter some of the transmitted wave's energy, reducing the strength of the response at the receiver. Magnetostrictive transducers are often used to generate and detect guided waves. These transducers depend on the magnetostrictive effect, where certain materials will deform in the presence of a magnetic field. The typical construction of one of these transducers is shown in figure 5, consisting of a magnetostrictive foil, meandering coil, and a biasing magnet. Materials typically used for the foil include Fe-Co and Terfenol-D. For wave generation, a high-frequency alternating current is supplied to the coil of the transducer, which generates an oscillating magnetic field that causes the foil to deform. For reception, the inverse occurs: deformation of the foil results in a current in the coil that can be detected. The deformation of the foil is usually coupled to the material to be inspected with an adhesive, and waves are transmitted through this bond. Obviously, an inspection robot cannot have its sensors bound to the surface of the cask. A robot is being designed for inspection, and it must deal with many challenges inside the cask, including tight confines, right-angle transitions, high temperatures, and radiation. For our initial design, we consider only the geometrical constraints, and present a design for a prototype that can be assembled from COTS components. The robot needs to be articulated to navigate the bends in the cask, so each wheel is individually actuated. The robot is controlled via a tether, which also supplies electrical power and compressed air. For localization, ultrasonic range-finders and a camera are equipped. Using the basic transducer, we experimented with various configurations of materials and geometry. In order to gather relevant data, we used force sensitive resistors to measure applied force, and a Matec computer system to generate and measure ultrasonic waves. A testing rig was constructed to simulate the geometrical constraints of the interior of the cask, and we experimented using deadweights, a pneumatic cylinder, and an air bladder to apply the force. It was discovered early in the testing process that the performance of the transducer was very sensitive to the alignment of the components, and the method by which the foil was attached. To maximize performance, we designed an enclosure that would hold the components in alignment while still allowing the foil to float. To test the effectiveness of our new transducer, we cut circular holes of varying diameter in 2 mm aluminum plate, and measured the response across them. It can be seen that there is a clear relationship between the strength of the received signal and the force applied, and to a lesser extent, the size of the defect. This design performs adequately as a proof of concept, and a more precisely fabricated enclosure should further increase the accuracy of its measurements.

42 ENGINEERING↗

The effect of impact damage and circular holes on the compressive strength of a graphite-epoxy laminate

Specimens were impacted by 1.27-cm-diameter aluminum spheres with speeds ranging from 52 to 101 m/s. Some specimens were impacted without any applied compressive load and then loaded to failure to determine their residual strength. Other specimens were loaded to a prescribed axial compressive strain and impacted while at that applied load. Loaded specimens that did not fail catastrophically on impact were subsequently loaded to failure to determine their residual strength. Low-velocity impact damage was found to degrade seriously the laminate static compressive strength. Low-strain compression-compression cyclic loading was found to degrade further the compressive strength of impact-damaged specimens. Specimens with circular holes having diameters up to a third of the specimen width were loaded to failure in compression. It was found that circular holes can also degrade the static compressive strength of the laminate. The effects of circular holes and impact damage on the compressive strength of the laminate are compared.

Starnes, J. H., Jr.↗

Scale model studies for improvement of flow patterns of a low-speed tunnel

Flow along a nacelle was investigated with and without an orifice plate inserted into the airstream. The flow became more uniform in transit through the orifice when compared with the upstream flow and remained more uniform immediately downstream from the orifice. No improvement was found farther downstream with or without the orifice plate. Various windmills were studied to determine their effects on the downstream flow pattern. The windmill retarded flow velocity inside the circle inscribed by the tip of free wheeling propellers (used as substitute windmills), while the main stream passed over the blades seemingly unrestricted and without showing any increase in diameter. Results show that by varying a torque, the flow across a windmill can be effectively redistributed, an effect that could be gainfully employed in situations where the main flow into a diffuser is concentrated near the center. The construction of the 1/24 scale model tunnel and the velocity transverses obtained on the model are discussed. The transverses indicate that the velocity distribution may be considered worse in the vertical than in the horizontal plane.

Barna, P. S.↗

Hollow cathode operation at high discharge currents

It was shown that ion thruster hollow cathode operation at high discharge current levels can induce reduced thruster lifetimes by causing cathode insert overheating and/or erosion of surfaces located downstream of the cathode. The erosion problem has been particularly baffling because the mechanism by which it occurs has not been understood. The experimental investigation described reveals the energies of the ions produced close to the cathode orifice can be several times the anode-to-cathode potential difference generally considered available to accelerate them. These energies (of order 50 eV) are sufficient to cause the observed erosion rates. The effects of discharge current (to 60 A), magnetic field configuration and the cathode flowrate, orifice diameter and insert design on the energies and current densities of these jet ions are examined. A model describing the mechanism by which the high energy ions could be produced when the anode-cathode potential difference is insufficient is proposed. The effects of discharge current on cathode temperature and internal pressure are also examined experimentally and described phenomenologically.

Friedly, Verlin Joe↗

Quantitative analysis of carbonaceous aerosols using Laser-Induced Breakdown Spectroscopy: A study on mass loading induced plasma matrix effects.

We present results indicating mass loading induced plasma matrix effects on the application of quantitative laser-induced breakdown spectroscopy (LIBS) for estimation of carbon contents in aerosols. An in-house flow-controlled powder-dispersion system generated carbonaceous aerosols with varying bi-modal particle size distributions ({approx} 1 {micro}m and 10 {micro}m median diameters), thereby resulting in a wide mass loading range. For ease of chemical handling and to eliminate toxic effects, common talcum powder was used as our standard aerosol. Normalized atomic species concentrations of C, i.e., (C)/(Si) ratios, were calculated from atomic emission lines of C I (248 nm), Si I (252 nm), and plasma temperatures estimated from a series of Mg I lines. The results show a decrease in (C)/(Si) ratio to about 65% of the initial value as relative mass loadings increased (5.5-100%) due to the increase in number concentrations of larger sized particles ({approx}10 {micro}m median diameter). As a comparison, normalized ratio of (Mg)/(Si) did not exhibit any marked change with increased mass loading. The normalized total absorption of photon flux across the C I (248 nm) spectral line indicated a strong correlation to the percentage decrease in (C)/(Si) ratio. We used an impactor with a cut-off size of around 10 {micro}m diameter to generate mono-modal aerosolized powders ({approx}1 {micro}m median diameter) that had lower relative mass loadings (0.32-0.16%). Similar LIBS analysis on these did not indicate any of the matrix effects. We conclude that for aerosol systems with widely varying mass loadings, quantitative LIBS analysis can be significantly affected by plasma matrix effects, specifically for the C I (248 nm) emission line as noticed in this study. This bears significance for the application of quantitative LIBS in the chemical characterization of all forms of carbonaceous aerosols.

Mukherjee, Dibyendu↗

SU-F-T-45: Dosimetric Effects of Saline Filled Balloons During IORT Using Xoft Electronic Brachytherapy

Purpose: The portability of Xoft Axxent Electronic Brachytherapy (EBx) System has made it a viable option for intraoperative radiation therapy (IORT) treatment of early-stage breast cancer. The low energy (50kVp) of the X-ray source makes the shielding easy, but also means its dose distribution is sensitive to the medium’s composition. Current treatment planning systems (TPS) typically assume homogenous water for brachytherapy dose calculations, including the pre-calculated atlas plans for the Xoft IORT cases. However, Xoft recommends using saline to fill the balloon applicator. This study investigates the dosimetric difference due to the increased effective atomic number (Zeff) from water (7.42) to saline (7.56). Methods: The diameter of the balloon applicators ranges from 3–6cm, with 4cm being most frequently used. For the 4-cm and 6-cm diameter applicators, MCNP Monte Carlo program was used to calculate the dose at the surface (Ds) of the middle section of the balloon and 1 cm away (D1cm) for water- and saline-filled balloons: one plan with a single dwell at the center and another with multiple dwells as in the atlas plans. The single dwell plan is a simple estimation of the dosimetry, while the atlas plan is representative of the actual dose distribution. Results: The single-dwell plan showed a 5.1% and 6.1% decrease in Ds for the 4- and 6-cm applicators, respectively, due to the saline. The atlas plan showed similar Results: 4.8% and 6.4% decrease, respectively. The decrease in D1cm is 4.3%–5.2% and 3.3%–5.3s% in the single-dwell and atlas plans, respectively, for the 4- and 6-cm applicator. Conclusion: The dosimetric effect introduced by saline is on the order of 5%. This effect should be taken into account during both treatment planning and patient outcome studies.

60 APPLIED LIFE SCIENCES↗

Effects of geometric structure, orientation and size on structural stability and thermal behavior of zinc oxide nanowires

Highlights: {yields} The structural stability, orientation effect and melting characteristic of zinc oxide (ZnO) nanowires are simulated by using the molecular dynamics with many-body tightbinding potential. {yields} The nanowire with a hexagonal cross section is more stable than that with other cross section type, namely, a rectangular, triangular, rhombohedral, octagonal, and circular cross section. {yields} The structural stability and melting temperature of a nanowire is sensitive to its diameter because of the surface energy and unfavorable coordination. -- Abstract: The structural stability, orientation effect and melting characteristic of zinc oxide (ZnO) nanowires are simulated by using the molecular dynamics with many-body tightbinding potential. The structural stability is affected by the geometric shape of the cross section of a nanowire. The nanowire with a hexagonal cross section is more stable than that with another cross section type, namely, a rectangular, triangular, rhombohedral, octagonal, and circular cross section. The structural stability and melting temperature of a nanowire is sensitive to its diameter because of the surface energy and unfavorable coordination. Remarkably, it is observed that hexagonal ZnO nanowires transform to metastable circular-type structures at temperatures lower than the melting point.

36 MATERIALS SCIENCE↗

Imaging an event horizon: mitigation of scattering toward Sagittarius A*

The image of the emission surrounding the black hole in the center of the Milky Way is predicted to exhibit the imprint of general relativistic (GR) effects, including the existence of a shadow feature and a photon ring of diameter ∼50 μas. Structure on these scales can be resolved by millimeter-wavelength very long baseline interferometry. However, strong-field GR features of interest will be blurred at λ ≥ 1.3 mm due to scattering by interstellar electrons. The scattering properties are well understood over most of the relevant range of baseline lengths, suggesting that the scattering may be (mostly) invertible. We simulate observations of a model image of Sgr A* and demonstrate that the effects of scattering can indeed be mitigated by correcting the visibilities before reconstructing the image. This technique is also applicable to Sgr A* at longer wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗