At least 1,333 records · Page 74

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Thermal Interface Materials (TIMs) are critical components in spacecraft thermal management systems, where thermal performance is strongly influenced by vacuum conditions, interface contact resistance, and layered metallic joint behavior. However, manufacturer-reported thermal conductivity values are often derived under idealized conditions and may not accurately represent performance within operational aerospace applications. To address this limitation, the Testbed for Advanced Interface Materials in Vacuum (TAIMV) was developed as a modular vacuum-compatible thermal conductivity characterization platform capable of evaluating aerospace-relevant TIM configurations under both ambient and high-vacuum environments. The testbed was derived from the ASTM C1044-16 guarded hot plate methodology and incorporates interchangeable layers of stainless steel coupon geometries, independently controlled main and guard heaters, embedded resistance temperature detectors (RTDs), thermocouples, multi-layer insulation (MLI), and a temperature-controlled cold plate to characterize through-thickness thermal gradients across layered interfaces. In the current configuration, interface compression is limited to the nominal contact pressure generated by the experimental stack assembly. Initial experimental campaigns were conducted at ambient pressure and below 1×10-5 torr for vacuum cases using multiple interface materials including Braycote 601EF and Krytox-based greases across a range of thermal operating conditions. In parallel, a coupled numerical Python thermal model was developed to predict temperature distribution throughout the stack while accounting for conduction, radiation, and parasitic heat transfer pathways and effective interface resistance effects. Experimental measurements and numerical predictions showed consistent thermal trends across multiple operating conditions and environmental states. Results also revealed measurable differences between ambient and vacuum thermal behavior, demonstrating the importance of interface resistance, parasitic heat transfer mechanisms, and stack geometry in determining effective thermal performance within layered thermal interfaces. The presented work establishes a foundation for future thermal model correlation efforts and expanded characterization of aerospace thermal interface materials under representative environmental conditions. Future work will focus on the integration of a load cell system to enable controlled pressure-dependent characterization of thermal interface materials under compressive loading. This capability will allow investigation of the influence of contact pressure on effective thermal conductivity, interface resistance, and thermal performance within layered aerospace thermal interfaces under representative operational conditions.

Thermal Development Testing↗

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil↗

Helmholtz Motor: A Novel Electric Machine That Enables High Temperature Superconducting Armatures

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Cryogenic electric machines are a promising technology for multi megawatt electric aircraft drivetrains. Second generation high temperature superconductors (HTS) are the ideal conductor for the field winding (typically the rotor) of superconducting machines, and they have attractive features for the armature winding (typically the stator) of these machines. However, their use in armature windings has been severely limited due to excessive AC losses in conventional electric machines. This presentation will present the working principle, design, and a performance trade study of a novel electric machine – termed a Helmholtz machine – that enables HTS armatures by significantly reducing AC losses. The working principle of the patent pending Helmholtz motor is to optimize the rotor-produced magnetic field (i.e., the field winding) so that it produces a magnetic field almost purely in the plane of the HTS. This is accomplished using 2 rotors that contain a set of matched Helmholtz coil pairs (or matched permanent magnet Halbach arrays). The armature (stator) HTS coils are positioned between the rotors and oriented to minimize the out of plane magnetic field. The armature HTS coils are also designed to minimize the out of plane component of their self field. The presentation will include the lessons learned in the sizing and design of this motor, including equations for how to match the magnet arrays. A performance trade study will be presented for a partially superconducting, radial flux version of the motor. The trade study involved an optimization of a motor design code based on analytical calculations (electromagnetic, AC loss, thermofluid, mechanical, and motor sizing) that determine the motor’s total efficiency and total specific power. The design code will be described in the presentation, with an emphasis on the calculation of magnetic fields, AC loss, and temperature distribution.

Superconducting electric machines↗

Monthly mean distribution of ozone and temperature

Global monthly mean charts for both hemispheres are given for four mid-season months, and for the pressure levels 30, 10, 1, and 0.1 mbar for temperature and 0.4 mbar for ozone. Charts of total ozone are provided separately. This set of charts shows clearly the very close coupling between the temperature and ozone distributions and demonstrates the influence of the large-scale planetary waves which give rise to very large longitudinal variations. The regular and interannual variability of temperature and ozone are discussed.

Labitzke, K.↗

Herschel-ATLAS: Dust Temperature and Redshift Distribution of SPIRE and PACS Detected Sources Using Submillimetre Colours

We present colour-colour diagrams of detected sources in the Herschel-ATLAS Science Demonstration Field from 100 to 500/microns using both PACS and SPIRE. We fit isothermal modified-blackbody spectral energy distribution (SED) models in order to extract the dust temperature of sources with counterparts in GAMA or SDSS with either a spectroscopic or a photometric redshift. For a subsample of 331 sources detected in at least three FIR bands with significance greater than 30 sigma, we find an average dust temperature of (28 plus or minus 8)K. For sources with no known redshifts, we populate the colour-colour diagram with a large number of SEDs generated with a broad range of dust temperatures and emissivity parameters and compare to colours of observed sources to establish the redshift distribution of those samples. For another subsample of 1686 sources with fluxes above 35 mJy at 350 microns and detected at 250 and 500 microns with a significance greater than 3sigma, we find an average redshift of 2.2 plus or minus 0.6.

Amblard, A.↗

Diurnal tide in the equatorial middle atmosphere as seen in LIMS temperatures

The distribution of day-night temperature differences in the middle atmosphere determined by the Nimbus 7 LIMS experiment is described. Day-night differences maximize at and are approximately symmetric about the equator. Successive centers of opposite sign increase in amplitude with altitude, the pattern having a vertical wavelength of approximately 25 km. Profiles of rocket meridional wind at Kwajalein (8.7 deg N) and Ascension Island (8.0 deg S) taken near local noon and averaged over the LIMS data period, exhibit maxima which support the tidal interpretation of the equatorial temperature pattern. These characteristics are in general agreement with previous observational and theoretical results for the solar driven diurnal tide. Substantial time variations in amplitude and in location of the temperature maxima are observed. The diurnal tide near the equatorial stratopause appears to be influenced by the phase of the semiannual oscillation.

Hitchman, M. H.↗

Analysis of temperature and pressure distribution of containers for nuclear waste material disposal in space

A computer program was adapted from a previous generation program to analyze the temperature and internal pressure response of a radioactive nuclear waste material disposal container following impact on the earth. This program considers component melting, LiH dissociation, temperature dependent properties and pressure and container stress response. Analyses were performed for 21 cases with variations in radioactive power level, container geometry, degree of deformation of the container, degree of burial and soil properties. Results indicated that the integrity of SS-316 containers could be maintained with partial burials of either underformed or deformed containers. Results indicated that completely buried waste containers, with power levels above 5 kW, experienced creep stress rupture failures in 4 to 12 days.

Vanbibber, L. E.↗

Observation of a two-temperature ion energy distribution in regions of polar wind flow

Study of deviations from thermal equilibrium among the ions in the ionosphere by considering that the 'light' ions H(+) and He(+) may be at a different temperature from the 'heavy' ion O(+). In particular, the case in which thermal protons are observed to be flowing relative to the assumed static ambient oxygen ions is considered. The proton flow is assumed to be along the direction of the magnetic field. Of the cases tested, it is found that the measured proton temperature is from one to ten times the measured oxygen ion temperature. Such temperature enhancements may be expected both because of the energy transfer associated with the ion flow and as a consequence of the preferential energy coupling from the light-ion distribution in the exosphere.

Maier, E. J.↗

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.

Allgood, Daniel C.↗

A study of radiometric surface temperatures: Their fluctuations, distribution and meaning

A consecutive night and day flight and measurements on the ground, were made in the region of Voves, south of Chartres. The statistical analysis of the thermal scanner data permitted the establishment of criteria for the homogeneity of surfaces. These criteria were used in defining the surface temperature values which are most representative for use in an energy balance approach to evapotranspiration (day) and heat balance (night). For a number of maize fields that airborne thermal scanner data permitted a detailed energy analysis of different fields of a same crop to be carried out. Such a detailed analysis was not necessary for a calculation of crop evapotranspiration which could be evaluated from the mean temperature of the crop surface. A differential analysis day night is of interest for enhancing the contrast between types of surfaces, as well as for a better definition of the daily energy balance. It should be stressed that, for a homogeneous region, a study such as the present one, could be carried out on a relatively small part of the total surface, as the results for a surface of 2.5 x 2 sq km were not significantly different from those obtained from a surface three times larger.

Perrier, A.↗

Residual circulations calculated from satellite data: Their relations to observed temperature and ozone distributions

Monthly mean residual circulations were calculated from eight years of satellite data. The diabatic circulation is usually found to give a good approximation to the residual circulation, but this is not always the case. In particular, an example is shown at 60 deg S and 30 mbar where the diabatic and residual circulations show very different annual variations. Correlations between the vertical component of the residual circulation and temperature and ozone were computed. The computations indicate that yearly variations of temperatures in the tropics are under radiative control, except during stratospheric warmings. Interannual variations in seasonal mean temperatures are shown to be under dynamical control everywhere. Correlations between seasonal means of the vertical component of the residual circulation and ozone mixing ratios are consistent with what would be expected from the ozone variations being due to differences in the ozone transport, although transport effects cannot easily be distinguished from photochemical effects above the altitude of the ozone mixing ratio peak. Finally, variations in total ozone are examined in comparison with residual circulation variations. A one to two month phase lag is seen in the annual variation in the total ozone at 60 deg N with respect to the maximum downward residual motions. This phase lag is greater at 60 deg N than at 60 deg S. There is evidence at 60 deg S of a greater downward trend in the mean zonal ozone maxima than there is in the minima. A decreasing trend in the maximum descending motion is seen to accompany the ozone trend at 60 deg S.

Geller, Marvin A.↗

Residual circulations calculated from satellite data - Their relations to observed temperature and ozone distributions

Monthly mean residual circulations were calculated from eight years of satellite data. The diabatic circulation is usually found to give a good approximation to the residual circulation, but this is not always the case. In particular, an example is shown at 60 deg S and 30 mbar where the diabatic and residual circulations show very different annual variations. Correlations between the vertical component of the residual circulation and temperature and ozone were computed. The computations indicate that yearly variations of temperatures in the tropics are under radiative control, except during stratospheric warmings. Interannual variations in seasonal mean temperatures are shown to be under dynamical control everywhere. Correlations between seasonal means of the vertical component of the residual circulation and ozone mixing ratios are consistent with what would be expected from the ozone variations being due to differences in the ozone transport, although transport effects cannot easily be distinguished from photochemical effects above the altitude of the ozone mixing ratio peak. Finally, variations in total ozone are examined in comparison with residual circulation variations. A one to two month phase lag is seen in the annual variation in the total ozone at 60 deg N with respect to the maximum downward residual motions. This phase lag is greater at 60 deg N than at 60 deg S. There is evidence at 60 deg S of a greater downward trend in the mean zonal ozone maxima than there is in the minima. A decreasing trend in the maximum descending motion is seen to accompany the ozone trend at 60 deg S.

Geller, Marvin A.↗