Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EIC ESR beam position monitors thermal and thermomechanical study preliminary design

The Electron Ion Collider (EIC) Electron Storage Ring (ESR) Beam Position Monitors (BPM) are designed to monitor the electron beam orbit position on a turn-by-turn and bunch-by-bunch basis in the vacuum chamber. Large variations in ESR fill pattern and bunch intensity imposes a large dynamic range on the BPM system design. And given the large ESR beam current - up to 2.5 A with 1160 x 20 nC bunches – the heating by synchrotron radiation (SR) and beam impedance is a significant concern. The high energy of the electrons – up to 18 GeV – leads to scat tering of the SR that produces high radiation doses and as sociated heating of structures away from the SR impact area. Because of this intense heating, and stringent position stability requirements, an in-depth engineering analysis was carried out. This paper will review the analysis made of the preliminary design and its main outcomes.

43 PARTICLE ACCELERATORS↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Measurements and Analyses to Enable Science for the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE)

Coastal cities provide the opportunity to characterize the substantial effects of manmade particles on marine cloud properties and processes. La Jolla lies to the north of San Diego, California, but it is often about a day directly downwind of the major pollution sources located in the ports of Los Angeles and Long Beach. The large dynamic range of aerosol particle concentrations combined with the multi-hour to multi-day persistence of stratocumulus cloud layers makes the site ideal for investigating the seasonal changes in cloud and aerosol properties as well as the quantitative relationships between cloud and aerosol properties. The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) characterized the extent, radiative properties, aerosol interactions, and precipitation characteristics of stratocumulus clouds in the Eastern Pacific across all four seasons at two coastal sites in La Jolla. This project was designed to enhance and expand the scientific uses of the ARM AMF1 measurements from EPCAPE. The goal was to ensure meaningful observations were collected that would enable science. The project included the following objectives: (1) Reviewing the ARM AMF1 measurements [ARM, 2021a; b] and circulating a summary of the measurements each week, (2) Comparing AMF1 measurements to those provided by collaborators (including filter measurements at the pier), (3) Collecting and analyzing filter samples from Scripps Pier by Fourier Transform Infrared spectroscopy (FTIR) and X-ray Fluorescence (XRF), (4) Assisting in operations of instruments provided by Guest PIs when possible, and (5) Providing an initial compilation of EPCAPE aerosol and cloud seasonal differences. The expected outcomes of these objectives were enhanced proposals and publications using EPCAPE measurements by helping to identify instrument issues, expanded data access and awareness by distributing weekly plots and related summaries, improved source-related attribution of aerosols with elemental tracers, additional observations provided by Guest PIs, and accelerated ACI studies enabled by the compiled seasonal summaries of aerosol and cloud properties. Three examples of the science enabled by this project are findings that (i) aerosol and cloud aqueous production contributes more than half of sulfate particle mass concentration, (ii) upwind sources make chemical composition very similar at nearby sites despite local differences in meteorology, and (iii) most of the large mass concentration of semi-volatile organic components is co-emitted and co-evaporated with nitrate. Together these findings illustrate how ARM extended field campaigns in coastal regions can be used to constrain ACI processes with direct observations. By using the unique ARM suite of cloud radiative products in addition to the measured aerosol properties at a coastal location, we were able to address the more specific question of which aerosol particles cause how much of the effects on clouds. Identifying this signature in coastal areas provides an opportunity to test the representation of aerosol sources by global models in a range of clean and urban-influenced conditions.

Russell, Lynn [Univ. of California, San Diego, CA ↗

Assessment of BPM options for the EIC Beam Accumulator Ring

The electron injection system for the Electron-Ion Collider (EIC) at BNL is designed to provide a beam of polarized electrons, which is crucial for studying the structure of protons and atomic nuclei. The Beam Accumulator Ring (BAR) is a part of the injection chain between the 750 MeV linear accelerator and the Rapid Cycling Synchrotron (RCS), which accelerates the beam up to full energy (5–18 GeV). The functional role of the BAR is to accumulate the charge injected from the linear accelerator in order to achieve the high intensity of the polarized electron beam required by the specifications for injection into the RCS. This objective will be realized through the sequential injection of bunches with a charge of 1.1 nC at a repetition rate of 30 Hz. Once the charge of a single bunch reaches 28 nC, the beam will be extracted from the BAR and injected into the RCS. The beam instrumentation needs to provide reliable measurements with the required accuracy over the dynamic range from 0.1 nC (one tenth of a typical injected bunch charge) to 32 nC – the maximum expected accumulated current. There are 10 Beam Position Monitors (BPMs) in the ring, 1 extra button-electrode assembly for the RF system, and 8 BPMs in the beam transport lines. The BPM locations are shown in Fig. 1, marked by blue rectangles. The ring BPMs will be capable of both average orbit and turn-by-turn measurement modes. Accurate measurement of the beam position with a large horizontal offset requires polynomial correction of the BPM nonlinearity.

43 PARTICLE ACCELERATORS↗

New Types of Ionization Sources for Mass Spectrometry

The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle (Contractor) and MDS Sciex (Participant) and ESA, Inc. (Participant) is to research, develop and apply new types of ionization sources and sampling/inlet systems for analytical mass spectrometry making use of the Participants state-of-the-art atmospheric sampling mass spectrometry electrochemical cell technology instrumentation and ancillary equipment. The two overriding goals of this research project are: to understand the relationship among the various instrumental components and operational parameters of the various ion sources and inlet systems under study, the chemical nature of the gases, solvents, and analytes in use, and the nature and abundances of the ions ultimately observed in the mass spectrometer; and to develop new and better analytical and fundamental applications of these ion sources and inlet systems or alternative sources and inlets coupled with mass spectrometry on the basis of the fundamental understanding obtained in Goal 1. The end results of this work are expected to be: (1) an expanded utility for the ion sources and inlet systems under study (such as the analysis of new types of analytes) and the control or alteration of the ionic species observed in the gas-phase; (2) enhanced instrument performance as judged by operational figures-of-merit such as dynamic range, detection limits, susceptibility to matrix signal suppression and sensitivity; and (3) novel applications (such as surface sampling with electrospray) in both applied and fundamental studies. The research projects outlined herein build upon work initiated under the previous CRADA between the Contractor and MDS Sciex on ion sources and inlet systems for mass spectrometry. Specific ion source and inlet systems for exploration of the fundamental properties and practical implementation of these principles are given.

47 OTHER INSTRUMENTATION↗

International Linear Collider Accelerator Physics R&D

ILC work at Illinois has concentrated primarily on technical issues relating to the design of the accelerator. Because many of the problems to be resolved require a working knowledge of classical mechanics and electrodynamics, most of our research projects lend themselves well to the participation of undergraduate research assistants. The undergraduates in the group are scientists, not technicians, and find solutions to problems that, for example, have stumped PhD-level staff elsewhere. The ILC Reference Design Report calls for 6.7 km circumference damping rings (which prepare the beams for focusing) using “conventional” stripline kickers driven by fast HV pulsers. Our primary goal was to determine the suitability of the 16 MeV electron beam in the AØ region at Fermilab for precision kicker studies.We found that the low beam energy and lack of redundancy in the beam position monitor system complicated the analysis of our data. In spite of these issues we concluded that the precision we could obtain was adequate to measure the performance and stability of a production module of an ILC kicker, namely 0.5%. We concluded that the kicker was stable to an accuracy of ~2.0% and that we could measure this precision to an accuracy of ~0.5%. As a result, a low energy beam like that at AØ could be used as a rapid-turnaround facility for testing ILC production kicker modules. The ILC timing precision for arrival of bunches at the collision point is required to be 0.1 picosecond or better. We studied the bunch-to-bunch timing accuracy of a “phase detector” installed in AØ in order to determine its suitability as an ILC bunch timing device. A phase detector is an RF structure excited by the passage of a bunch. Its signal is fed through a 1240 MHz high-Q resonant circuit and then down-mixed with the AØ 1300 MHz accelerator RF. We used a kind of autocorrelation technique to compare the phase detector signal with a reference signal obtained from the phase detector’s response to an event at the beginning of the run. We determined that the device installed in our beam, which was instrumented with an 8-bit 500 MHz ADC, could measure the beam timing to an accuracy of 0.4 picoseconds. Simulations of the device showed that an increase in ADC clock rate to 2 GHz would improve measurement precision by the required factor of four. As a result, we felt that a device of this sort, assuming matters concerning dynamic range and long-term stability can be addressed successfully, would work at the ILC. Cost effective operation of the ILC will demand highly reliable, fault tolerant and adaptive solutions for both hardware and software. The large numbers of subsystems and large multipliers associated with the modules in those subsystems will cause even a strong level of unit reliability to become an unacceptable level of system availability. An evaluation effort is underway to evaluate standards associated with high availability, and to guide ILC development with standard practices and well-supported commercial solutions. One area of evaluation involves the Advanced Telecom Computing Architecture (ATCA) hardware and software. We worked with an ATCA crate, processor monitors, and a small amount of ATCA circuit boards in order to develop a backplane “spy” board that would let us watch the ATCA backplane communications and pursue development of an inexpensive processor monitor that could be used as a physics-driven component of the crate-level controls system. We made good progress, and felt that we had determined a productive direction to extend this work. We felt that we had learned enough to begin designing a workable processor monitor chip if there were to be sufficient interest in ATCA shown by the ILC community. Fault recognition is a challenging issue in the crafting a high reliability controls system. With tens of thousands of independent processors running hundreds of thousands of critical processes, how can the system identify that a problem has arisen and determine the appropriate steps to take to correct, or compensate, for the failure? One possible solution might come through the use of the OpenClovis supervisory system, which runs on Linux processors and allows a select set of processors to monitor the behavior of individual processes and processors in a large, distributed controls network. We found that OpenClovis exhibited an irritating amount of sensitivity to the exact version of the Linux kernel running on the processors, and that it was poorly equipped to help us sort through problems that arose through conflicts so deep in the operating systems of the processors. But once this issue was addressed, we found that it performed as expected, recognizing crashes and process (and processor) failures.

43 PARTICLE ACCELERATORS↗

Science and Technology Review October/November 2009

This month's issue has the following articles: (1) Award-Winning Collaborations Provide Solutions--Commentary by Steven D. Liedle; (2) Light-Speed Spectral Analysis of a Laser Pulse--An optical device inspects and stops potentially damaging laser pulses; (3) Capturing Waveforms in a Quadrillionth of a Second--The femtoscope, a time microscope, improves the temporal resolution and dynamic range of conventional recording instruments; (4) Gamma-Ray Spectroscopy in the Palm of Your Hand--A miniature gamma-ray spectrometer provides increased resolution at a reduced cost; (5) Building Fusion Targets with Precision Robotics--A robotic system assembles tiny fusion targets with nanometer precision; (6) ROSE: Making Compiler Technology More Accessible--An open-source software infrastructure makes powerful compiler techniques available to all programmers; (7) Restoring Sight to the Blind with an Artificial Retina--A retinal prosthesis could restore vision to people suffering from eye diseases; (8) Eradicating the Aftermath of War--A remotely operated system precisely locates buried land mines; (9) Compact Alignment for Diagnostic Laser Beams--A smaller, less expensive device aligns diagnostic laser beams onto targets; and (10) Securing Radiological Sources in Africa--Livermore and other national laboratories are helping African countries secure their nuclear materials.

42 ENGINEERING↗

SPARTICUS: Small Particles in Cirrus Science and Operations Plan

From a mass-weighted perspective, cirrus clouds exert an enormous influence on the radiative energy budget of the earth’s climate system. Owing to their location in the cold upper troposphere, cirrus can significantly reduce the outgoing longwave radiation while, at the same time, remaining relatively transmissive to solar energy. Thus, cirrus clouds are the only cloud genre that can exert a direct radiative warming influence on the climate system (Ackerman et al. 1988). It is not surprising, therefore, that general circulation models (GCMs) are especially sensitive to the presence of cirrus in the model atmosphere. Lohmann and Roeckner (1995), for instance, show that the climate sensitivity can vary by as much as 40% due to the properties of cirrus varying between transparent and opaque limits. Lohmann and Roeckner (1995) also identify a key feedback by cirrus that is often overlooked; on longer time scales cloud heating in the upper troposphere can act to maintain and modulate the general circulation of the atmosphere through accelerating the subtropical and polar jet streams. Understanding these mechanisms and representing them in models is complicated by the fact that cirrus properties vary over an enormous dynamic range compared to most other clouds.

14 SOLAR ENERGY↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

Through the Windshield Driver Recognition

Biometric recognition of vehicle occupants in unconstrained environments is rife with a host of challenges. In particular, the complications arising from imaging through vehicle windshields provide a significant hurdle. Distance to target, glare, poor lighting, head pose of occupants, and speed of vehicle are some of the challenges. We explore the construction of a multi-unit computational camera system to mitigate these challenges in order to obtain accurate and consistent face recognition results. This paper documents the hardware components and software design of the computational imaging system. Also, we document the use of RCNN for face detection and GAN for machine learning-inspired High Dynamic Range Imaging, artifact removal, and image fusion.

Cornett, David↗

Agglomerate Sizing in Aluminized Propellants Using Digital Inline Holography and Traditional Diagnostics

Aluminized ammonium perchlorate composite propellants can form large molten agglomerated particles that may result in poor combustion performance, slag accumulation, and increased two-phase flow losses. Quantifying agglomerate size distributions are needed to gain an understanding of agglomeration dynamics and ultimately design new propellants for improved performance. Due to complexities of the reacting multiphase environment, agglomerate size diagnostics are difficult and measurement accuracies are poorly understood. To address this, the current paper compares three agglomerate sizing techniques applied to two propellant formulations. Particle collection on a quench plate and backlit videography are two relatively common techniques, whereas digital inline holography is an emerging alternative for three-dimensional measurements. Atmospheric pressure combustion results show that all three techniques are able to capture the qualitative trends; however, significant differences exist in the quantitative size distributions and mean diameters. For digital inline holography, methods are proposed that combine temporally resolved high-speed recording with lower-speed but higher spatial resolution measurements to correct for size–velocity correlation biases while extending the measurable size dynamic range. Finally, the results from this work provide new guidance for improved agglomerate size measurements along with statistically resolved datasets for validation of agglomerate models.

42 ENGINEERING↗

The Impact of Operated Window Shading on Visual Comfort, Non-Visual Health, and Energy Demand from Electric Lighting

This paper introduces a simulation-based workflow to assess annual circadian lighting performance, glare risk and energy demand for an array of seated view positions under operated shading and electric lighting conditions. This workflow uses a combination of 9-band and 81-band simulations to represent daylight and electric lighting respectively. Annual daylight-driven calculations rely on a python-based code provided in the LARK simulation engine which was used to run 180-degree high dynamic range (HDR) renderings with 9-bands of spectral resolution. The results reveal the impact of shading systems on equivalent melanopic lux (EML) and daylight glare probability (DGP) over time and the energy demand (kWh) from electric lighting systems to supplement eye-level recommendations from the WELL v2 Building Standard.

Rockcastle, Siobhan↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

Promoter Architecture and Promoter Engineering in Saccharomyces cerevisiae

Promoters play an essential role in the regulation of gene expression for fine-tuning genetic circuits and metabolic pathways in Saccharomyces cerevisiae (S. cerevisiae). However, native promoters in S. cerevisiae have several limitations which hinder their applications in metabolic engineering. These limitations include an inadequate number of well-characterized promoters, poor dynamic range, and insufficient orthogonality to endogenous regulations. Therefore, it is necessary to perform promoter engineering to create synthetic promoters with better properties. Here, we review recent advances related to promoter architecture, promoter engineering and synthetic promoter applications in S. cerevisiae. We also provide a perspective of future directions in this field with an emphasis on the recent advances of machine learning based promoter designs.

machine learning↗

New Insights about CuO Nanoparticles from Inelastic Neutron Scattering

Inelastic Neutron Scattering (INS) spectroscopy has provided a unique insight into the magnetodymanics of nanoscale copper (II) oxide (CuO). We present evidence for the propagation of magnons in the directions of the ordering vectors of both the commensurate and helically modulated incommensurate antiferromagnetic phases of CuO. The temperature dependency of the magnon spin-wave intensity (in the accessible energy-range of the experiment) conforms to the Bose population of states at low temperatures (T ≤ 100 K), as expected for bosons, then intensity significantly increases, with maximum at about 225 K (close to TN), and decreases at higher temperatures. The obtained results can be related to gradual softening of the dispersion curves of magnon spin-waves and decreasing the spin gap with temperature approaching TN on heating, and slow dissipation of the short-range dynamic spin correlations at higher temperatures. However, the intensity of the magnon signal was found to be particle size dependent, and increases with decreasing particle size. This “reverse size effect” is believed to be related to either creation of single-domain particles at the nanoscale, or “superferromagnetism effect” and the formation of collective particle states.

43 PARTICLE ACCELERATORS↗

Quantitative Proteomic Profiling of Low Dose Ionizing Radiation Effects in a Human Skin Model

To assess molecular responses to low doses of radiation that may be encountered during medical diagnostic procedures, nuclear accidents, or terrorist acts, a quantitative global proteomic approach was used to identify protein alterations in a reconstituted human skin tissue treated with 10 cGy of ionizing radiation. Subcellular fractionation was employed to remove highly abundant structural proteins and provide insight on radiation induced alterations in protein abundance and localization. In addition, peptides were post-fractionated using high resolution 2-dimensional liquid chromatography to increase the dynamic range of detection of protein abundance and translocation changes. Quantitative data was obtained by labeling peptides with 8-plex isobaric iTRAQ tags. A total of 207 proteins were detected with statistically significant alterations in abundance and/or subcellular localization compared to sham irradiated tissues. Bioinformatics analysis of the data indicated that the top canonical pathways affected by low dose radiation are related to cellular metabolism. Among the proteins showing alterations in abundance, localization and proteolytic processing was the skin barrier protein filaggrin which is consistent with our previous observation that ionizing radiation alters profilaggrin processing with potential effects on skin barrier functions. In addition, a large number of proteases and protease regulators were affected by low dose radiation exposure indicating that altered proteolytic activity may be a hallmark of low dose radiation exposure. While several studies have demonstrated altered transcriptional regulation occurs following low dose radiation exposures, the data presented here indicates post-transcriptional regulation of protein abundance, localization, and proteolytic processing play an important role in regulating radiation responses in complex human tissues.

Environmental Molecular Sciences Laboratory↗

Spectrometer for Sky-Scanning Sun-Tracking Atmospheric Research (4STAR): Instrument Technology

The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with diffraction spectroscopy, to improve knowledge of atmospheric constituents and their links to air-pollution/climate. Direct beam hyper-spectral measurement of optical depth improves retrievals of gas constituents and determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution. 4STAR measurements will tighten the closure between satellite and ground-based measurements. 4STAR incorporates a modular sun-tracking/ sky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and future detector evolution. Technical challenges include compact optical collector design, radiometric dynamic range and stability, and broad spectral coverage. Test results establishing the performance of the instrument against the full range of operational requirements are presented, along with calibration, engineering flight test, and scientific field campaign data and results.

atmosphere↗