Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm{sup 3} volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

07 ISOTOPE AND RADIATION SOURCES↗

Heavy Higgs signal–background interference in $gg\rightarrow VV$ in the Standard Model plus real singlet

For the Standard Model extended with a real scalar singlet field, the modification of the heavy Higgs signal due to interference with the continuum background and the off-shell light Higgs contribution is studied for gg → ZZ, WW → 4 lepton processes at the Large Hadron Collider. Interference effects can range from O(10%) to O(1) effects for integrated cross sections. Despite a strong cancellation between the heavy Higgs–continuum and the heavy Higgs–light Higgs interference, the full interference is clearly non-negligible and modifies the heavy Higgs line shape. A |M VV –M h2 | < Γ h2 cut mitigates interference effects to O(10%) or less. A public program that allows one to simulate the full interference is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic Transport in Lithiated Iron and Bismuth Fluoride

Metal networks are formed during the lithiation of metal fluorides. Previous reports indicate that these networks are bi-continuous with the possibility to support electronic transport, though no quantitative analysis has been performed. In this study, thin films of FeF 2 and BiF 3 were chemically lithiated using n-butyllithium to form these metal networks. Direct current (DC) polarization and electrochemical impedance spectroscopy (EIS) were utilized to find electronic conductivity and results were compared to their pure metals. Here, the results indicate films to have higher than expected conductivity value which indicates that these metal networks support electronic transport during lithiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Regional Electricity Prices and Building Type on the Economics of Commercial Photovoltaic Systems

To identify the impacts of regional electricity prices and building type on the economics of solar photovoltaic (PV) systems, 207 rate structures across 77 locations and 16 commercial building types were evaluated. Results for expected solar value are reported for each location and building type. Aggregated results are also reported, showing general trends across various impact categories.

14 SOLAR ENERGY↗

Consideration of Factors Affecting Strip Effluent pH and Sodium Content

A number of factors were investigated to determine possible reasons for why the Strip Effluent (SE) can sometimes have higher than expected pH values and/or sodium content, both of which have prescribed limits. All of the factors likely have some impact on the pH values and Na content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consideration of Factors Affecting Strip Effluent pH and Sodium Content

A number of factors were investigated to determine possible reasons for why the Strip Effluent (SE) can sometimes have higher than expected pH values and/or sodium content, both of which have prescribed limits. All of the factors likely have some impact on the pH values and Na content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consideration of Factors Affecting Strip Effluent PH and Sodium Content

A number of factors were investigated to determine possible reasons for why the Strip Effluent (SE) can sometimes have higher than expected pH values and/or sodium content, both of which have prescribed limits. All of the factors likely have some impact on the pH values and Na content.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AREA 2: Novel Materials for Robust Repair of Leaky Wellbores in CO 2 Storage Formations

The potential leakage of hydrocarbon fluids or CO 2 out of subsurface formations through wells with fractured cement or debonded microannuli is a primary concern in oil and gas production and CO 2 storage. The presence of fractures in a cement annulus with apertures on the order of 10–300 microns can pose a significant leakage danger with effective permeability in the range of 0.1–1 mD (millidarcy). Leakage pathways with small apertures are often difficult to repair using conventional oilfield cement, thus a low-viscosity sealant that can be easily placed into these fractures while providing an effective seal is desired. The development of a novel application using pH-triggered polymeric sealants could potentially be the solution to plugging these fractures and that was the research aim of this study. The application is based on the transport and reaction of a low-pH poly(acrylic acid) polymer through fractures in strongly alkaline cement. The pH-sensitive microgels viscosify upon neutralization with cement to become highly swollen gels with substantial yield stress that can block fluid flow. Experiments in a cement fracture determined the effects of the viscosification and gel deposition via real-time visual observation and measurements of pressure gradient and effluent pH. While the pH-triggered gelling mechanism and rheology measurements of the neutralized polymer gel show promising results, the polymer solution in contact with cement undergoes an undesirable reaction known as polymer syneresis. Syneresis is caused by the release of calcium cation from cement that collapses the polymer network. Syneresis produces an unstable calcium-precipitation byproduct that is detrimental to the strength and stability of the gel in place. As a result, gel-sealed leakage pathways that subjected to various degrees of syneresis often failed to hold back pressures. Several chemicals were studied to inhibit polymer syneresis and tested for pretreatment of cement cores to remove calcium and prevent syneresis during polymer placement. A chelating agent, sodium triphosphate (Na 5 P 3 O 10 ), was found to successfully eliminate syneresis without compromising the injectivity of polymer solution during placement. Polymer gel strength is determined by recording the maximum holdback pressure gradients during liquid breakthrough tests after various periods of pretreatment and polymer shut-in time. Cores pretreated with Na 5 P 3 O 10 successfully held up to an average of 80 psi/ft, which is significantly greater than the expected threshold value of about 0.1-5 psi/ft required to prevent flow in a typical CO 2 leakage scenario. The use of such inexpensive, pH-triggered poly-acrylic acid polymer allows long-term robust seal of leaky wellbores under high pH conditions.

01 COAL, LIGNITE, AND PEAT↗

Integrating Data Sources for Improved Safeguards and Accountancy of Electrochemical Fuel Reprocessing Systems. Final Report

Electrochemical reprocessing (also commonly known as “pyroprocessing”) of used nuclear fuel is an alternative to aqueous reprocessing that confers a number of advantages, including the ability to process more recently-discharged fuel, smaller resultant waste volumes, and the lack of isolation of plutonium in the product stream. While electrochemical reprocessing systems have seen a significant research and development effort, nuclear safeguards and security of these systems remains under-developed, particularly given the significant differences in operating environment and process flowsheet compared with established aqueous methods. Objective 4 of DOE’s nuclear energy research and development activities in Nuclear Energy Research and Development Roadmap is: “Understand and minimize the risks of nuclear proliferation and terrorism.” Material Control & Accountancy (MC&A) programs at nuclear processing plants deter and detect theft and diversion of nuclear material by both outside and inside adversaries. Empirical modeling and data analytics of online measurements and state indicators can improve the timeliness of detection and reduce the uncertainty in accountancy measures. To support the development and demonstration of such methods, data are needed that capture expected measurement values collected throughout electrochemical reprocessing facilities. A review of the available literature of current research in measurements for electrochemical reprocessing systems identified twenty-two candidate measurement methodologies, which characterize fuel/salt composition, concentrations of various isotopes and elements, and operational parameters throughout the reprocessing facility. Four primary measurement methodologies have been simulated based on either physical simulations or empirical correlations: gamma emissions, neutron emissions, hybrid k-edge densitometry (HKED), and cyclic voltammetry. Initial investigation into the use of these measures for process monitoring and detection suggests the approach is viable and worthy of further investigation. This report summarizes efforts to generate signatures of key measurements during operation of electrochemical reprocessing facilities and initial investigation of data analytics to support process monitoring, diversion detection, and accountancy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of the Sulfur-Saturated Melt Versions of the LAW Phase 4 Glasses

In this report, results are provided from the analyses of a series of sulfur-saturated melt versions of simulated nuclear waste glasses, and chemical analysis of the wash solution resulting from the preparation of these glasses. The glasses were selected and fabricated by the Pacific Northwest National Laboratory as part of a broader study of the influence of glass composition on chemical durability, sulfur retention, and other properties. The resulting data will be used in the development of enhanced property/composition models for waste vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the sulfur-saturated versions of the quenched glasses to allow for comparisons with the targeted compositions, as well as the measured compositions of the quenched glasses. The measured concentrations of chlorine, and fluorine were below the targeted values for most of the study glasses, likely because of volatility during the multiple melting steps. The measured concentrations of B 2 O 3 , K 2 0, and Li 2 0 were generally low relative to the targeted values. As expected, the measured concentrations of SO 3 in most of the glasses were higher than targeted due to the use of the sulfur saturation method in fabricating these glasses. The wash solutions contained mainly sodium and sulfur, with moderate concentrations of potassium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Induction Stirring and Particle Tracking in Molten Uranium

Two independent numerical models have been developed to simulate the behavior of carbon impurities in molten uranium metal. Informed by experimental parameters, one model was created using the commercial software Star-CCM+ and compared with another developed using open-source codes, including OpenFOAM, Finite Element Method Magnetics (FEMM) and a First Passage Kinetic Monte Carlo (FPKMC) approach. The target experimental system features a 404g uranium metal charge containing an average carbon concentration of 139 ppm which was melted in a vacuum induction furnace at 1400° C then resolidified. The microstructures of the uranium and its impurities before and after melting have been characterized and reported separately. Prior to simulating the uranium-carbon system described, the numerical models were validated using a previously published nonradioactive experimental system to ensure agreement with expected output values. Focus has been placed on modeling velocity fields under induction stirring and impurity particle trajectories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRACER Carbonaceous Aerosols Thrust – University of California, Davis Field Campaign Report

The broader U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign aims to increase our understanding of convective cloud life cycles and aerosol-convection interactions. Our TRACER Carbonaceous Aerosols Thrust-University of California, Davis (TRACER-CAT-UCDavis) study complemented these broader aims by characterizing and quantifying the optical properties and composition of carbonaceous aerosols during part of the TRACER intensive sampling period (July 1- July 31, 2022) at the first ARM Mobile Facility (AMF1) main site (M1) in La Porte, Texas. Our measurements complemented the suite of instrumentation already provided by the AMF1, expanding the capabilities through deployment of unique, state-of-the-science instrumentation. The instrumentation included: (i) two cavity-attenuated phase shift spectroscopy single-scatter albedo (CAPS-SSA) instruments operating at 530 nm and 630 nm, and that were modified to characterize particle light absorption, extinction, and scattering at elevated humidities; (ii) the UC Davis dual-wavelength cavity ringdown-photoacoustic spectrometer (CRD-PAS), which characterizes dry particle extinction and absorption at 405 nm and 532 nm; (iii) a soot particle aerosol mass spectrometer (SP-AMS) that operated in “laser only” mode that characterized the size-dependent compositions of black carbon (BC)-containing particles; (v) a thermal denuder, to remove coatings on particles; and (vi) a scanning electrical mobility sizer (SEMS), to characterize particle mobility diameters from 10-1300 nm. Our measurements occurred alongside complementary observations made by Los Alamos National Laboratory (LANL) during the TRACER-CAT-LANL study, including a humidified CAPS-SSA instrument operating at 450 nm. Our primary scientific interest is in understanding the relationship between particle composition and light absorption, with a particular focus on the influence of water uptake. While it is known that coatings on BC can enhance absorption, the extent to which this occurs in the atmosphere and the specific role that water plays as a coating remain unclear. The TRACER-CAT-UCDavis measurements were made with near-complete coverage for the CRD-PAS, SP-AMS, and SEMS throughout the intensive period. The UC Davis humidified CAPS-SSA instruments had significant challenges with operation owing to the demanding conditions (large temperature fluctuations, high humidity), exacerbated by supply chain issues that delayed resolution of these challenges. However, the humidified CAPS-SSA instrument operated by LANL operated throughout the intensive period with near-complete coverage. The dry light extinction measurements from the CRD-PAS measurements and the LANL CAPS-SSA exhibited a good correlation, although the CAPS-SSA systematically measured greater extinction values than expected. While all instruments, with the exception of an aerodynamic particle sizer (APS), measured behind a common particulate matter (PM)2.5 μm cyclone, the greater extinction measured by the LANL CAPS-SSA compared to the CRD-PAS may have resulted from different losses of larger particles in the sampling lines from the cyclone to the instruments; the tubing length was shorter from the cyclone to the LANL CAPS-SSA, consistent with this idea. A summary of the TRACER-CAT-UCDavis measurements, along with some of the TRACER-CAT-LANL measurements, are shown in the figure below. Notably, there were periods when the contributions of presumed dust were substantial and even dominated the observed light extinction and absorption. Also, there was a clear shift in the behavior of submicron particles from before July 16, 2022 to after, with the prior period exhibiting regular episodes of new particle formation and the latter period exhibiting rapid variations in the concentrations of small particles.

54 ENVIRONMENTAL SCIENCES↗

Electromagnetic Inhomogeneous-Energy-Density-Driven Instability in the UCLA Large Plasma Device (EM-IEDDI in LAPD) (Final Technical Report)

Using the Large Plasma Device (LAPD), the electromagnetic signatures associated with the inhomogeneous-energy-density-driven (IEDD) instability were targeted for documentation in a lab experiment. Exploitable features of LAPD are the extreme-length, high-beta, low-collisionality, and excellent reproducibility. The signatures of interest were mode amplitude, mode structure, frequency spectrum, phase velocity, and excitation threshold. The abrupt inhomogeneity at the interface between two coaxial plasma columns, that have disparate space potential values, were expected to generate a strong, localized, transverse, dc electric field and form a strong ExB-flow inhomogeneity that was expected to trigger broadband, intermediate-frequency waves that propagate many gyroradii beyond the interfacial source region. WVU was unable to destabilize the IEDDI mode in LAPD. Experimental limitation of three different parameters conspire to prevent IEDDI-favorable conditions even though Alfven-favorable conditions are met. Electron-neutral collision frequency is too high, Structuring of the radial profile of the radial electric field is negligible and the control of that structure is minimal, and the Magnetic field is too large for some purposes and too small for other purposes. WVU designed a new antenna and relied on externally-driving the IEDDI (instead of spontaneous destabilization). The antenna operation failed for unforeseen reasons and lack of electrician time and availability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Si K EDGE STRUCTURE AND VARIABILITY IN GALACTIC X-RAY BINARIES

We survey the Si K edge structure in various absorbed Galactic low-mass X-ray binaries (LMXBs) to study states of silicon in the inter- and circum-stellar medium. The bulk of these LMXBs lie toward the Galactic bulge region and all have column densities above 10{sup 22} cm{sup −2}. The observations were performed using the Chandra High Energy Transmission Grating Spectrometer. The Si K edge in all sources appears at an energy value of 1844 ± 0.001 eV. The edge exhibits significant substructure that can be described by a near edge absorption feature at 1849 ± 0.002 eV and a far edge absorption feature at 1865 ± 0.002 eV. Both of these absorption features appear variable with equivalent widths up to several mÅ. We can describe the edge structure using several components: multiple edge functions, near edge absorption excesses from silicates in dust form, signatures from X-ray scattering optical depths, and a variable warm absorber from ionized atomic silicon. The measured optical depths of the edges indicate much higher values than expected from atomic silicon cross sections and interstellar medium abundances, and they appear consistent with predictions from silicate X-ray absorption and scattering. A comparison with models also indicates a preference for larger dust grain sizes. In many cases, we identify Si xiii resonance absorption and determine ionization parameters between log ξ = 1.8 and 2.8 and turbulent velocities between 300 and 1000 km s{sup −1}. This places the warm absorber in close vicinity of the X-ray binaries. In some data, we observe a weak edge at 1.840 keV, potentially from a lesser contribution of neutral atomic silicon.

79 ASTRONOMY AND ASTROPHYSICS↗

A DEEP X-RAY VIEW OF THE BARE AGN ARK 120. I. REVEALING THE SOFT X-RAY LINE EMISSION

The Seyfert 1 galaxy Ark 120 is a prototype example of the so-called class of bare nucleus active galactic nuclei (AGNs), whereby there is no known evidence for the presence of ionized gas along the direct line of sight. Here deep (>400 ks exposure), high-resolution X-ray spectroscopy of Ark 120 is presented from XMM-Newton observations that were carried out in 2014 March, together with simultaneous Chandra /High Energy Transmission Grating exposures. The high-resolution spectra confirmed the lack of intrinsic absorbing gas associated with Ark 120, with the only X-ray absorption present originating from the interstellar medium (ISM) of our own Galaxy, with a possible slight enhancement of the oxygen abundance required with respect to the expected ISM values in the solar neighborhood. However, the presence of several soft X-ray emission lines are revealed for the first time in the XMM-Newton RGS spectrum, associated with the AGN and arising from the He- and H-like ions of N, O, Ne, and Mg. The He-like line profiles of N, O, and Ne appear velocity broadened, with typical FWHMs of ∼5000 km s{sup −1}, whereas the H-like profiles are unresolved. From the clean measurement of the He-like triplets, we deduce that the broad lines arise from a gas of density n {sub e} ∼ 10{sup 11} cm{sup −3}, while the photoionization calculations infer that the emitting gas covers at least 10% of 4 π steradian. Thus the broad soft X-ray profiles appear coincident with an X-ray component of the optical–UV broad-line region on sub-parsec scales, whereas the narrow profiles originate on larger parsec scales, perhaps coincident with the AGN narrow-line region. The observations show that Ark 120 is not intrinsically bare and substantial X-ray-emitting gas exists out of our direct line of sight toward this AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

First Weak-lensing Results from “See Change”: Quantifying Dark Matter in the Two z ≳ 1.5 High-redshift Galaxy Clusters SPT-CL J2040–4451 and IDCS J1426+3508

We present a weak-lensing study of SPT-CL J2040–4451 and IDCS J1426+3508 at z = 1.48 and 1.75, respectively. The two clusters were observed in our “See Change” program, a Hubble Space Telescope survey of 12 massive high-redshift clusters aimed at high-z supernova measurements and weak-lensing estimation of accurate cluster masses. We detect weak but significant galaxy shape distortions using infrared images from the Wide Field Camera 3 (WFC3), which has not yet been used for weak-lensing studies. Both clusters appear to possess relaxed morphology in projected mass distribution, and their mass centroids agree nicely with those defined by both the galaxy luminosity and X-ray emission. Using a Navarro–Frenk–White profile, for which we assume that the mass is tightly correlated with the concentration parameter, we determine the masses of SPT-CL J2040–4451 and IDCS J1426 + 3508 to be M{sub 200}=8.6{sub −1.4}{sup +1.7}×10{sup 14} M{sub ⊙} and 2.2{sub −0.7}{sup +1.1}×10{sup 14} M{sub ⊙}, respectively. The weak-lensing mass of SPT-CL J2040–4451 shows that the cluster is clearly a rare object. Adopting the central value, the expected abundance of such a massive cluster at z≳1.48 is only ∼0.07 in the parent 2500 sq. deg. survey. However, it is yet premature to claim that the presence of this cluster creates a serious tension with the current ΛCDM paradigm unless that tension will remain in future studies after marginalizing over many sources of uncertainties such as the accuracy of the mass function and the mass–concentration relation at the high-mass end. The mass of IDCS J1426+3508 is in excellent agreement with our previous Advanced Camera for Surveys-based weak-lensing result, while the much higher source density from our WFC3 imaging data makes the current statistical uncertainty ∼40% smaller.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular momentum of dwarf galaxies

We present measurements of baryonic mass M{sub b} and specific angular momentum (sAM) j{sub b} in 14 rotating dwarf Irregular (dIrr) galaxies from the LITTLE THINGS sample. These measurements, based on 21 cm kinematic data from the Very Large Array and stellar mass maps from the Spitzer Space Telescope, extend previous AM measurements by more than two orders of magnitude in M{sub b}. The dwarf galaxies show systematically higher j{sub b} values than expected from the j{sub b}∝M{sub b}{sup 2/3} scaling of spiral galaxies, representative of a scale-free galaxy formation scenario. This offset can be explained by decreasing baryon mass fractions f{sub M}=M{sub b}/M{sub dyn} (where M{sub dyn} is the dynamical mass) with decreasing M{sub b} (for M{sub b}<10{sup 11} M{sub ⊙}). We find that the sAM of neutral atomic hydrogen (H i) alone is about 2.5 times higher than that of the stars. The M–j relation of H i is significantly steeper than that of the stars, as a direct consequence of the systematic variation of the H i fraction with M{sub b}.

79 ASTRONOMY AND ASTROPHYSICS↗