Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Alcohol alters hepatic FoxO1, p53, and mitochondrial SIRT5 deacetylation function

Chronic alcohol consumption affects the gene expression of a NAD-dependent deacetylase Sirtuis 1 (SIRT1) and the peroxisome proliferator-activated receptor-{gamma} coactivator1{alpha} (PGC-1{alpha}). Our aim was to verify that it also alters the forkhead (FoxO1) and p53 transcription factor proteins, critical in the hepatic response to oxidative stress and regulated by SIRT1 through its deacetylating capacity. Accordingly, rats were pair-fed the Lieber-DeCarli alcohol-containing liquid diets for 28 days. Alcohol increased hepatic mRNA expression of FoxO1 (p = 0.003) and p53 (p = 0.001) while corresponding protein levels remained unchanged. However phospho-FoxO1 and phospho-Akt (protein kinase) were both decreased by alcohol consumption (p = 0.04 and p = 0.02, respectively) while hepatic p53 was found hyperacetylated (p = 0.017). Furthermore, mitochondrial SIRT5 was reduced (p = 0.0025), and PGC-1{alpha} hyperacetylated (p = 0.027), establishing their role in protein modification. Thus, alcohol consumption disrupts nuclear-mitochondrial interactions by post-translation protein modifications, which contribute to alteration of mitochondrial biogenesis through the newly discovered reduction of SIRT5.

60 APPLIED LIFE SCIENCES↗

GAMMA-RAY SPECTRAL PROPERTIES OF MATURE PULSARS: A TWO-LAYER MODEL

We use a simple two-layer outer gap model, whose accelerator consists of a primary region and a screening region, to discuss the {gamma}-ray spectrum of mature pulsars detected by Fermi. By solving the Poisson equation with an assumed simple step-function distribution for the charge density in these two regions, the distribution of the electric field and the curvature radiation process of the accelerated particles can be calculated. In our model, the properties of the phase-averaged spectrum can be completely specified by three gap parameters, i.e., the fractional gap size in the outer magnetosphere, the gap current in the primary region, and the gap size ratio between the primary region and the total gap size. We discuss how these parameters affect the spectral properties. We argue that although the radiation mechanism in the outer gap is a curvature radiation process, the observed gamma-ray spectrum can substantially deviate from the simple curvature spectrum because the overall spectrum consists of two components, i.e., a primary region and a screening region. In some pulsars, the radiation from the screening region is so strong that the photon index from 100 MeV to several GeV can be as flat as {approx}2. We show that the fitting fractional gap thickness of the canonical pulsars increases with the spin-down age. We find that the total gap current is about 50% of the Goldreich-Julian value and the thickness of the screening region is a few percent of the total gap thickness. We also find that the predicted {gamma}-ray luminosity is less dependent on the spin-down power (L{sub sd}) for pulsars with L{sub sd} {approx}> 10{sup 36} erg s{sup -1}, while the {gamma}-ray luminosity decreases with the spin-down power for pulsars with L{sub sd} {approx}< 10{sup 36} erg s{sup -1}. This relation may imply that the major gap closure mechanism is a photon-photon pair-creation process for pulsars with L{sub sd} {approx}> 10{sup 36} erg s{sup -1}, while it is a magnetic pair-creation process for pulsars with {sub sd} {approx}< 10{sup 36} erg s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Treatment of Nitric Acid-, U(VI)-, and Tc(VII)-Contaminated Groundwater in Intermediate-Scale Physical Models of an In Situ Biobarrier

Metal and hydrogen ion acidity and extreme nitrate concentrations at Department of Energy legacy waste sites pose challenges for successful in situ U and Tc bioimmobilization. In this study, we investigated a potential in situ biobarrier configuration designed to neutralize pH and remove nitrate and radionuclides from nitric acid-, U-, and Tc-contaminated groundwater for over 21 months. Ethanol additions to groundwater flowing through native sediment and crushed limestone effectively increased pH (from 4.7 to 6.9), promoted removal of 116 mM nitrate, increased sediment biomass, and immobilized 94% of total U. Increased groundwater pH and significant U removal was also observed in a control column that received no added ethanol. Sequential extraction and XANES analyses showed U in this sediment to be solid-associated U(VI), and EXAFS analysis results were consistent with uranyl orthophosphate (UO2)3(PO4)2·4H2O(s), which may control U solubility in this system. Ratios of respiratory ubiquinones to menaquinones and copies of dissimilatory nitrite reductase genes, nirS and nirK, were at least 1 order of magnitude greater in the ethanol-stimulated system compared to the control, indicating that ethanol addition promoted growth of a largely denitrifying microbial community. Sediment 16S rRNA gene clone libraries showed that Betaproteobacteria were dominant (89%) near the source of influent acidic groundwater, whereas members of Gamma- and Alphaproteobacteria and Bacteroidetes increased along the flow path as pH increased and nitrate concentrations decreased, indicating spatial shifts in community composition as a function of pH and nitrate concentrations. Results of this study support the utility of biobarriers for treating acidic radionuclide- and nitrate-contaminated groundwater.

09 BIOMASS FUELS↗

Valence quark contribution for the {gamma}N{yields}{delta} quadrupole transition extracted from lattice QCD

Starting with a covariant spectator quark model developed for the nucleon N and the {delta} in the physical pion mass region, we extend the predictions of the reaction {gamma}N{yields}{delta} to the lattice QCD regime. The quark model includes S and D waves in the quark-diquark wave functions. Within this framework, it is the D-wave part in the {delta} wave function that generates nonzero valence contributions for the quadrupole form factors of the transition. Those contributions are however insufficient to explain the physical data, since the pion cloud contributions dominate. To separate the two effects, we apply the model to the lattice regime in a region where the pion cloud effects are negligible and adjust the D-state parameters directly to the lattice data. This process allows us to obtain a better determination of the D-state contributions. Finally, by adding a simple parametrization of the pion cloud, we establish the connection between the experimental data and the lattice data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extreme γ –Ray Radiation Tolerance of Spectrometer–Grade CsPbBr 3 Perovskite Detectors

The perovskite compound CsPbBr 3 has recently been discovered as a promising room-temperature semiconductor radiation detector, offering an inexpensive and easy-to-manufacture alternative to the current benchmark material Cd 1–x Zn x Te (CZT). The performance of CsPbBr 3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co-60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. Notably, these results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr 3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma-ray radiation.

36 MATERIALS SCIENCE↗

Motional narrowing and ergodic bands in excited superdeformed states of {sup 194}Hg.

The E{sub {gamma}}-E{sub {gamma}} coincidence spectra from the electromagnetic decay of excited superdeformed states in {sup 194}Hg reveal surprisingly narrow ridges, parallel to the diagonal. A total of 100-150 excited bands are found to contribute to these ridges, which account for nearly all the unresolved E2 decay strength. Comparison with theory suggests that these excited bands have many components in their wave functions, yet they display remarkable rotational coherence. This phenomenon can be explained in terms of the combination of shell effects and motional narrowing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Active interrogation of Special Nuclear Material containers using AmBe quasi-forward biased directional source and PGNAA

Special Nuclear Material (SNM) including 95% 235 U and 239 Pu is capable of being identified by utilizing a quasi-forward directional AmBe source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). HPGe and LaBr 3 detector arrays were used to identify and quantify the peak-to-background and peak-to-total ratios of the associated photon spectra from the SNM encased in a polyethylene shield. The conducted simulations varied the volume of the SNM and neutron source strength in the MCNP data card to conduct an uncertainty analysis. Photopeaks identified include K-shell X-rays from 235 U and 239 Pu, 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peak from the prompt gamma interaction from hydrogen. Relationships between peak-to-total and peak-to-background as a function of SNM and particle history were investigated to aid in the analysis. The capabilities of both detector systems to acquire well resolved photopeak with a 5% relative error or less, with a 1 Ci source activity, and a peak-to-background ratio of 1.15. Finally, this was determined to take 326 s for LaBr 3 and 163 s for HPGe which is comparable to current methods for material detection which take between 100 and 900 s to acquire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

22(R)-hydroxycholesterol and pioglitazone synergistically decrease cholesterol ester via the PPARγ–LXRα–ABCA1 pathway in cholesterosis of the gallbladder

Highlights: • Cholesterosis is a metabolic disease characterized by excessive lipid droplets. • Lipid droplet efflux is mediated by the ABCA1 transporter. • 22(R)-hydroxycholesterol can activate LXRα and up-regulate ABCA1. • Pioglitazone up-regulates ABCA1 in a PPARγ–LXRα–ABCA1-dependent manner. • 22(R)-hydroxycholesterol and pioglitazone synergistically decrease lipid droplets. - Abstract: Cholesterosis is a disease of cholesterol metabolism characterized by the presence of excessive lipid droplets in the cytoplasm. These lipid droplets are mainly composed of cholesterol esters derived from free cholesterol. The removal of excess cholesterol from gallbladder epithelial cells (GBECs) is very important for the maintenance of intracellular cholesterol homeostasis and the preservation of gallbladder function. Several lines of evidence have indicated that the activation of either peroxisome proliferator-activated receptor gamma (PPARγ) or liver X receptor α (LXRα) relates to cholesterol efflux. While pioglitazone can regulate the activation of PPARγ, 22(R)-hydroxycholesterol can activate LXRα and is a metabolic intermediate in the biosynthesis of steroid hormones. However, the effect of 22(R)-hydroxycholesterol in combination with pioglitazone on cholesterosis of the gallbladder is unclear. GBECs were treated with pioglitazone, 22(R)-hydroxycholesterol or PPARγ siRNA followed by Western blot analysis for ATP-binding cassette transporter A1 (ABCA1), PPARγ and LXRα. Cholesterol efflux to apoA-I was determined, and Oil Red O staining was performed to monitor variations in lipid levels in treated GBECs. Our data showed that 22(R)-hydroxycholesterol can modestly up-regulate LXRα while simultaneously increasing ABCA1 by 56%. The combination of 22(R)-hydroxycholesterol and pioglitazone resulted in a 3.64-fold increase in ABCA1 expression and a high rate of cholesterol efflux. Oil Red O staining showed an obvious reduction in the lipid droplets associated with cholesterosis in GBECs. In conclusion, the present findings indicate that the anti-lipid deposition action of 22(R)-hydroxycholesterol combined with pioglitazone involves the activation of the PPARγ–LXRα–ABCA1 pathway, increased ABCA1 expression and the efflux of cholesterol from GBECs. Thus, 22(R)-hydroxycholesterol synergistically combined with pioglitazone to produce a remarkable effect on lipid deposition in cholesterosis GBECs.

60 APPLIED LIFE SCIENCES↗

Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS combined with radiotherapy for patients with GBM. This treatment is feasible, with acceptable toxicity and patient survivals higher than in historical controls. This study can form the basis for a multicenter, randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Al2O3 Atomic Layer Deposition on Nanostructured γ-Mg(BH4)2 for H2 Storage

In the context of the growing hydrogen (H 2 ) economy, the demand for H 2 storage materials is high, and metal borohydrides are of particular interest. Magnesium borohydride, Mg(BH 4 ) 2 , has one of the highest hydrogen capacities of all known metal hydrides (14.9 wt % H) but suffers from high operating temperatures, slow kinetics for (de)hydrogenation, and the loss of capacity upon cycling. Strategies to address these challenges include nanoencapsulation and the use of chemical additives. This work is the first to utilize these two strategies simultaneously by using atomic layer deposition (ALD). For this new approach to modify borohydrides, we chose the well-studied Al 2 O 3 ALD process using trimethylaluminum and water. Although there has been limited use of aluminum-based additives for Mg(BH 4 ) 2 , we demonstrate that the low-temperature H 2 capacity was doubled, desorption kinetics were increased by a factor of 3, and 100 cycles of Al 2 O 3 suppressed the release of diborane compared to the uncoated Mg(BH4)2. We identified that the use of trimethylaluminum and water in the ALD process affected the decomposition pathway and that the Al 2 O 3 film growth is dominated by infiltration due to the high porosity of the ..gamma..-phase Mg(BH 4 ) 2 . From these results, the potential of ALD as a method to functionalize solid-state H 2 storage materials is inferred, and recommendations for future ALD processes are presented.

08 HYDROGEN↗

Ligand efficacy shifts a nuclear receptor conformational ensemble between transcriptionally active and repressive states

Abstract Nuclear receptors (NRs) are thought to dynamically alternate between transcriptionally active and repressive conformations, which are stabilized upon ligand binding. Most NR ligand series exhibit limited bias, primarily consisting of transcriptionally active agonists or neutral antagonists, but not repressive inverse agonists—a limitation that restricts understanding of the functional NR conformational ensemble. Here, we report a NR ligand series for peroxisome proliferator-activated receptor gamma (PPARγ) that spans a pharmacological spectrum from repression (inverse agonism) to activation (agonism) where subtle structural modifications switch compound activity. While crystal structures provide snapshots of the fully repressive state, NMR spectroscopy and conformation-activity relationship analysis reveals that compounds within the series shift the PPARγ conformational ensemble between transcriptionally active and repressive conformations that are natively populated in the apo/ligand-free ensemble. Our findings reveal a molecular framework for minimal chemical modifications that enhance PPARγ inverse agonism and elucidate their influence on the dynamic PPARγ conformational ensemble.

Science & Technology - Other Topics↗

{eta}{sup '} production in proton-proton collisions far from the threshold

I discuss exclusive production of the {eta}{sup '} meson in the pp{yields}p{eta}{sup '}p reaction far from the threshold. The contribution of diffractive component as well as that for {gamma}*{gamma}*{yields}{eta}{sup '} fusion are calculated. In the first case the formalism of unintegrated gluon distribution functions (UGDF) is used. The distributions in the Feynman x{sub F} (or rapidity), transferred four-momenta squared between initial and final protons (t{sub 1},t{sub 2}) and azimuthal angle difference between outgoing protons ({phi}) are calculated. The deviations from the sin{sup 2}({phi}) dependence predicted by one-step vector-vector-pseudoscalar coupling are quantified and discussed. The results are compared with the results of the WA102 collaboration at CERN. Most of the models of UGDF from the literature give too small cross section as compared to the WA102 data and predict angular distribution in relative azimuthal angle strongly asymmetric with respect to {pi}/2 in disagreement with the WA102 data. This points to a different mechanism at the WA102 energy. Predictions for RHIC, Tevatron and LHC are given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parameterized Post-Newtonian Expansion of Scalar-Vector-Tensor Theory of Gravity

We investigate the weak-field, post-Newtonian expansion to the solution of the field equations in scalar-vector-tensor theory of gravity. In the calculation we restrict ourselves to the first post Newtonian. The parameterized post Newtonian (PPN) parameters are determined by expanding the modified field equations in the metric perturbation. Then, we compare the solution to the PPN formalism in first PN approximation proposed by Will and Nordtvedt and read of the coefficients (the PPN parameters) of post Newtonian potentials of the theory. We find that the values of {gamma}{sub PPN} and {beta}{sub PPN} are the same as in General Relativity but the coupling functions {beta}{sub 1}, {beta}{sub 2}, and {beta}{sub 3} are the effect of the preferred frame.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bose-Einstein condensates with attractive 1/r interaction: The case of self-trapping

Amplifying on a proposal by O'Dell et al. for the realization of Bose-Einstein condensates of neutral atoms with attractive 1/r interaction, we point out that the instance of self-trapping of the condensate, without an external trap potential, is physically best understood by introducing appropriate 'atomic' units. This reveals a remarkable scaling property: the physics of the condensate depends only on the two parameters N{sup 2}a/a{sub u} and {gamma}/N{sup 2}, where N is the particle number, a the scattering length, a{sub u} the 'Bohr' radius, and {gamma} the trap frequency in atomic units. We calculate accurate numerical results for self-trapping wave functions and potentials, and for energies, sizes, and peak densities, and compare with previous variational results. We point out the existence of a second solution of the extended Gross-Pitaevskii equation for negative scattering lengths, with and without trapping potential, which is born together with the ground state in a tangent bifurcation. This indicates the existence of an unstable collectively excited state of the condensate for negative scattering lengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom{sup TM}), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole region-of-interest imaging. Conclusions: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗