Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphical models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Recent Updates to Radiation Organ Dose Estimation Tool PIMAL

A computational phantom with moving arms and legs and an accompanying graphical user interface, PIMAL, was previously developed to enable radiation dose estimation for different postures in a user-friendly manner. This initial version of the software was useful in adjusting the posture, generating the corresponding MCNP input file, and performing the radiation transport simulations for dose calculations using MCNP5 or MCNPX. However, it only included one mathematical phantom model (hermaphrodite) and allowed only isotropic point sources. Recently, the software was enhanced by adding two more mathematical phantom models, a male and female, and the source features were enhanced significantly by adding internal and external source options in a pull-down menu. Although the initial version of the software included only a mathematical hermaphrodite phantom, the features and models in the software are constantly being enhanced by adding more phantoms as well as other options to enable dose assessment for different configurations/cases in a user-friendly manner. In this latest version of the software, ICRP's recently released reference male and female voxel phantoms are included in a pull-down menu. The male and female models are described using 7 and 14 million voxels, respectively. Currently, the software is being modified further to include the International Commission on Radiation Protection's (ICRP) reference male and female voxel phantoms. Additionally, some case studies are being implemented and included in a library of input files. This paper describes recent updates to the software.

59 BASIC BIOLOGICAL SCIENCES↗

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

National Atmospheric Release Advisory Center (NARAC) Capabilities for Homeland Security

The Department of Energy's National Atmospheric Release Advisory Center (NARAC) provides critical information during hazardous airborne releases as part of an integrated national preparedness and response strategy. Located at Lawrence Livermore National Laboratory, NARAC provides 24/7 tools and expert services to map the spread of hazardous material accidentally or intentionally released into the atmosphere. NARAC graphical products show affected areas and populations, potential casualties, and health effect or protective action guideline levels. LLNL experts produce quality-assured analyses based on field data to assist decision makers and responders. NARAC staff and collaborators conduct research and development into new science, tools, capabilities, and technologies in strategically important areas related to airborne transport and fate modeling and emergency response. This paper provides a brief overview of some of NARAC's activities, capabilities, and research and development.

99 GENERAL AND MISCELLANEOUS↗

Electronic structure and anisotropic chemical bonding in TiNF from ab initio study

Accounting for disorder in anatase titanium nitride fluoride TiNF is done through atoms re-distributions based on geometry optimizations using ultra soft pseudo potentials within density functional theory DFT. The fully geometry relaxed structures are found to keep the body centering of anatase (I4{sub 1}/amd No. 141). The new structural setups are identified with space groups I-4m2 No. 119 and Imm2 No. 44 which obey the 'group to subgroup' relationships with respect to anatase. In the ground state Imm2 structure identified from energy differences, TiNF is found semi-conducting with similar density of states features to anatase TiO{sub 2} and a chemical bonding differentiated between covalent like Ti-N versus ionic like Ti-F. Inter-anion N-F bonding is also identified. - Graphical Abstract: The geometry optimized ground state anatase derived TiNF structure with arrangement of open faceted TiN3F3 distorted octahedra. The insert shows the arrangement of octahedra in anatase TiO{sub 2}. Highlights: Black-Right-Pointing-Pointer Original approach of TiNF structure for addressing the electronic band structure. Black-Right-Pointing-Pointer Based on anatase, two different ordering scheme models with geometry optimization. Black-Right-Pointing-Pointer New structures obeying the group{yields}subgroup relationships with Imm2 ground state from energy. Black-Right-Pointing-Pointer In the ground state TiNF is found semi-conducting with similar density of states to anatase TiO{sub 2}. Black-Right-Pointing-Pointer Chemical bonding differentiated between covalent like Ti-N and ionic Ti-F.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulse distortion and modulation instability in laser plasma interaction

The present paper deals with the propagation of a short, intense, Gaussian laser pulse in plasma. Using a one dimensional model, a wave equation including finite pulse length and group velocity dispersion is set up and solved to obtain the intensity distribution across the laser pulse. It is shown that the pulse profile becomes asymmetric as it propagates through plasma. Further, the growth rate of modulation instability and range of unstable frequencies across the laser pulse have been derived and graphically analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive smart simulator for characterization and MPPT construction of PV array

Partial shading conditions are among the most important problems in large photovoltaic array. Many works of literature are interested in modeling, control and optimization of photovoltaic conversion of solar energy under partial shading conditions, The aim of this study is to build a software simulator similar to hard simulator and to produce a shading pattern of the proposed photovoltaic array in order to use the delivered information to obtain an optimal configuration of the PV array and construct MPPT algorithm. Graphical user interfaces (Matlab GUI) are built using a developed script, this tool is easy to use, simple, and has a rapid of responsiveness, the simulator supports large array simulations that can be interfaced with MPPT and power electronic converters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

GMctdospp: Description and validation of a CT dose calculation system

Purpose: To develop a Monte Carlo (MC)-based computed tomography (CT) dose estimation method with a graphical user interface with options to define almost arbitrary simulation scenarios, to make calculations sufficiently fast for comfortable handling, and to make the software free of charge for general availability to the scientific community. Methods: A framework called GMctdospp was developed to calculate phantom and patient doses with the MC method based on the EGSnrc system. A CT scanner was modeled for testing and was adapted to half-value layer, beam-shaping filter, z-profile, and tube-current modulation (TCM). To validate the implemented variance reduction techniques, depth-dose and cross-profile calculations of a static beam were compared against DOSXYZnrc/EGSnrc. Measurements for beam energies of 80 and 120 kVp at several positions of a CT dose-index (CTDI) standard phantom were compared against calculations of the created CT model. Finally, the efficiency of the adapted code was benchmarked against EGSnrc defaults. Results: The CT scanner could be modeled accurately. The developed TCM scheme was confirmed by the dose measurement. A comparison of calculations to DOSXYZnrc showed no systematic differences. Measurements in a CTDI phantom could be reproduced within 2% average, with a maximal difference of about 6%. Efficiency improvements of about six orders of magnitude were observed for larger organ structures of a chest-examination protocol in a voxelized phantom. In these cases, simulations took 25 s to achieve a statistical uncertainty of ∼0.5%. Conclusions: A fast dose-calculation system for phantoms and patients in a CT examination was developed, successfully validated, and benchmarked. Influences of scan protocols, protection method, and other issues can be easily examined with the developed framework.

60 APPLIED LIFE SCIENCES↗

Kronecker-structured covariance models for multiway data

Many applications produce multiway data of exceedingly high dimension. Modeling such multi-way data is important in multichannel signal and video processing where sensors produce multi-indexed data, e.g. over spatial, frequency, and temporal dimensions. We will address the challenges of covariance representation of multiway data and review some of the progress in statistical modeling of multiway covariance over the past two decades, focusing on tensor-valued covariance models and their inference. We will illustrate through a space weather application: predicting the evolution of solar active regions over time.

97 MATHEMATICS AND COMPUTING↗

R and DE Robotic Sensor Intern Team: Sensor Suite Software and User Interface

The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. A postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans with one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 5) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. During alignment, local features are used to recognize points within the walls that are especially unique and noticeable (salient) based on their deviation from the expected surface of the wall. These are used as landmarks to register the clouds, which also informs precise localization of the base at each scan point. After registration, clouds are 'painted' with RGB data from the spherical cameras, as shown below. The painted clouds provide a 3D, colorized model of the environment which improves the realism of the experience for the user. Painting also labels high-resolution color imagery from the 3D cameras with depth values. Following sensor fusion, individual walls and cylindrical duct surfaces are segmented from the scene for individual analysis using a Random Sample Consensus algorithm. This algorithm allows segmentation of planar walls and cylindrical ducts. Once individual walls are identified, each point within the wall can be compared to its neighbors and the wall overall in order to detect local areas with damaged concrete. Automatic rebar detection is also performed using the contrast in Lidar return intensity between iron and concrete. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First-principle investigation of Jahn-Teller distortion and topological analysis of chemical bonds in LiNiO{sub 2}

First-principle GGA+U calculations were performed on the undistorted rhombohedral R3-bar m model, the collinear Jahn-Teller distorted monoclinic C2/m model, and six non-collinear Jahn-Teller distortion ordering models of LiNiO{sub 2}. The zigzag and C2/m models are found to be the most stable and the next most stable structural models, respectively. An energy gap appears for the C2/m and zigzag structures, whereas no energy gap appears for the R3-bar m structure. Topological analyses were performed on the R3-bar m, C2/m and zigzag models using the atoms-in-molecules theory and the electron localization function. The results show that the Ni-O interaction is the transit closed-shell interaction, in which the net electron transfer occurs from the Ni ion to the ligand O ions. The Ni-O bond possesses the {sigma} dative bond character and is polarized toward the O ions. In the distorted structures, the bonding electrons around the oxygen atom are strongly polarized toward the long Ni-O bond. - Graphical abstract: Isosurfaces of the difference charge density and the electron localization function for the zigzag structure of LiNiO{sub 2}. Highlights: > Using ELF and AIM, topological analyses were carried out on different structures. > The zigzag Jahn-Teller distortion ordering is the most stable structure. > Semiconductor gap emerges in the C2/m and zigzag structures. > The Ni-O bonds are dative bonds. > In the distorted structures, bond electrons accumulate in the long Ni-O bond basins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRACC: An open source software for processing sap flux data from thermal dissipation probes

Here, thermal dissipation probes (TDPs) have become a widely used method of monitoring plant water use in recent years. The use of TDPs requires calibration to a theoretical zero-flow value (ΔT0); usually based upon the assumption that at least some nighttime measurements represent zero-flow conditions. Fully automating the processing of data from TDPs is made exceedingly difficult due to errors arising from many sources. However, it is desirable to minimize variation arising from different researchers’ processing data, and thus, a common platform for processing data, including editing raw data and determination of ΔT0, is useful and increases the transparency and replicability of TDP-based research. Here, we present the TDP data processing software TRACC (Thermal dissipation Review Assessment Cleaning and Conversion) to serve this purpose. TRACC is an open-source software written in the language R, using graphical presentation of data and on screen prompts with yes/no or simple numerical responses. It allows the user to select several important options, such as calibration coefficients and the exclusion of nights when vapor pressure deficit does not approach zero. Although it is designed for users with no coding experience, the outputs of TRACC could be easily incorporated into more complex models or software.

60 APPLIED LIFE SCIENCES↗

A multiscale coupled finite-element and phase-field framework to modeling stressed grain growth in polycrystalline thin films

A previously-developed finite-deformation- and crystal-elasticity-based constitutive theory for stressed grain growth in cubic polycrystalline bodies has been augmented to include a description of excess surface energy and grain-growth stagnation mechanisms through the use of surface effect state variables in a thermodynamically-consistent manner. The constitutive theory was also implemented into a multiscale coupled finite-element and phase-field computational framework. With the material parameters in the constitutive theory suitably calibrated, our three-dimensional numerical simulations show that the constitutive model is able to accurately predict the experimentally-determined evolution of crystallographic texture and grain size statistics in polycrystalline copper thin films deposited on polyimide substrate and annealed at high-homologous temperatures. In particular, our numerical analyses show that the broad texture transition observed in the annealing experiments of polycrystalline thin films is caused by grain growth stagnation mechanisms. - Graphical abstract: - Highlights: • Developing a theory for stressed grain growth in polycrystalline thin films. • Implementation into a multiscale coupled finite-element and phase-field framework. • Quantitative reproduction of the experimental grain growth data by simulations. • Revealing the cause of texture transition to be due to the stagnation mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DeepMC: a deep learning method for efficient Monte Carlo beamlet dose calculation by predictive denoising in magnetic resonance-guided radiotherapy

Abstract Emerging magnetic resonance (MR) guided radiotherapy affords significantly improved anatomy visualization and, subsequently, more effective personalized treatment. The new therapy paradigm imposes significant demands on radiation dose calculation quality and speed, creating an unmet need for the acceleration of Monte Carlo (MC) dose calculation. Existing deep learning approaches to denoise the final plan MC dose fail to achieve the accuracy and speed requirements of large-scale beamlet dose calculation in the presence of a strong magnetic field for online adaptive radiotherapy planning. Our deep learning dose calculation method, DeepMC, addresses these needs by predicting low-noise dose from extremely noisy (but fast) MC-simulated dose and anatomical inputs, thus enabling significant acceleration. DeepMC simultaneously reduces MC sampling noise and predicts corrupted dose buildup at tissue-air material interfaces resulting from MR-field induced electron return effects. Here we demonstrate our model’s ability to accelerate dose calculation for daily treatment planning by a factor of 38 over traditional low-noise MC simulation with clinically meaningful accuracy in deliverable dose and treatment delivery parameters. As a post-processing approach, DeepMC provides compounded acceleration of large-scale dose calculation when used alongside established MC acceleration techniques in variance reduction and graphics processing unit-based MC simulation.

Engineering↗

An unsteady flow of magnetic nanoparticles as drug carrier suspended in micropolar fluid through a porous tapered arterial stenosis under non-uniform magnetic field and periodic body acceleration

A mathematical model has been developed for pulsatile flow of blood through a tapered arterial stenosis in a porous medium under the influence of non-uniform magnetic field and periodic body acceleration treating blood as micropolar fluid carrying iron oxide nanoparticles. The governing equations of the system are solved numerically using finite difference schemes. The effects of stenotic height, taper angle, micropolar parameters, magnetic field, porosity, pulsatility, and magnetic nanoparticles on the flow of blood are analysed, and the results are represented graphically. It is significant to note that the flow parameters such as wall shear stress and flow resistance increase with increase in stenotic height, tapering parameter, magnetic field, pulsatile Reynolds number, time period, particle concentration, and particle mass parameters. Wall shear stress decreases with the increasing values of coupling number and it shows opposite behaviour in the case of flow resistance. Also increase in Darcy number leads to decrease in wall shear stress and flow resistance. The significance of treating blood as micropolar fluid is that the rotation of particles is taken into account. Cardiovascular diseases occur mainly due to abnormal blood flow in the arteries. To normalize the blood flow in the arteries, analysis of parameters involved in the study is essential. Hence, the present study has various applications in biomedical sciences. The effects of nanoparticles on blood flow analysed in the study have significant applications in delivery of drugs for treating cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis, stoichiometry and thermal stability of Zn{sub 3}N{sub 2} powders prepared by ammonolysis reactions

Zn{sub 3}N{sub 2} powders were prepared by ammonolysis reactions at 600 deg. C and examined by thermogravimetric analysis, powder X-ray and neutron diffraction. The powders obtained in this way are unstable in an oxygen atmosphere above 450 deg. C. In an argon atmosphere, the powders are stable up to their decomposition point at around 700 deg. C. Structural models obtained from Rietveld refinements against the powder neutron diffraction data indicate that the Zn{sub 3}N{sub 2} powders so-prepared have the anti-bixbyite structure and are almost certainly stoichiometric with no compelling evidence of nitrogen vacancies. Further, no evidence was found for aliovalent oxygen substitution at the nitrogen sites. The calculated bond valence sums imply that Zn{sub 3}N{sub 2} cannot be described as a 100% ionic compound. The structural findings are supported by photoluminescence measurements that reveal a band gap of approximately 0.9 eV. - Graphical abstract: Zn{sub 3}N{sub 2} powders prepared by careful ammonolysis reactions form with the anti-bixbyite structure and are almost certainly stoichiometric with no evidence for aliovalent oxygen substitution at the nitrogen sites. Zn{sub 3}N{sub 2} cannot be described as a 100% ionic compound and PL measurements reveal a narrow band gap of approximately 0.9 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for a Higgs boson produced in association with a charm quark and decaying to a W boson pair in proton-proton collisions at $ \sqrt{s}=13 $ TeV

This paper presents a search for a Higgs boson produced in association with a charm quark (cH) which allows to probe the Higgs-charm Yukawa coupling strength modifier κ$_{c}$. Higgs boson decays to a pair of W bosons are considered, where one W boson decays to an electron and a neutrino, and the other W boson decays to a muon and a neutrino. The data, corresponding to an integrated luminosity of 138 fb$^{−1}$, were collected between 2016 and 2018 with the CMS detector at the LHC at a center-of-mass energy of $ \sqrt{s}=13 $ TeV. Upper limits at the 95% confidence level (CL) are set on the ratio of the measured yield to the standard model expectation for cH production. The observed (expected) upper limit is 1065 (506), corresponding to an observed (expected) constraint of |κ$_{c}$| < 211 (95). When combined with the previous search for cH in the diphoton decay channel of the Higgs boson, the limits are interpreted as observed (expected) constraints at 95% CL on the value of κ$_{c}$, |κ$_{c}$| < 47 (51).[graphic not available: see fulltext]

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

Polyacrylamide-hydroxyapatite composite: Preparation, characterization and adsorptive features for uranium and thorium

The composite of synthetically produced hydroxyapatite (HAP) and polyacrylamide was prepared (PAAm-HAP) and characterized by BET, FT-IR, TGA, XRD, SEM and PZC analysis. The adsorptive features of HAP and PAAm-HAP were compared for UO{sub 2}{sup 2+} and Th{sup 4+}. The entrapment of HAP into PAAm-HAP did not change the structure of HAP. Both structures had high affinity to the studied ions. The adsorption capacity of PAAm-HAP was than that of HAP. The adsorption dependence on pH and ionic intensity provided supportive evidences for the effect of complex formation on adsorption process. The adsorption kinetics was well compatible to pseudo second order model. The values of enthalpy and entropy changes were positive. Th{sup 4+} adsorption from the leachate obtained from a regional fluorite rock confirmed the selectivity of PAAm-HAP for this ion. In consequence, PAAm-HAP should be considered amongst favorite adsorbents for especially deposition of nuclear waste containing U and Th, and radionuclide at secular equilibrium with these elements. - Graphical abstract: SEM images of hydroxyapatite (HAP) and polyacrylamide-hydroxyapatite (PAAm-HAP), and the adsorption isotherms for Uranium and Thorium. Highlights: Black-Right-Pointing-Pointer Composite of PAAm-HAP was synthesized from hydroxyapatite and polyacrylamide. Black-Right-Pointing-Pointer The materials were characterized by BET, FT-IR, XRD, SEM, TGA and PZC analysis. Black-Right-Pointing-Pointer HAP and PAAm-HAP had high sorption capacity and very rapid uptake for UO{sub 2}{sup 2+} and Th{sup 4+}. Black-Right-Pointing-Pointer Super porous PAAm was obtained from PAAm-HAP after its removal of HAP content. Black-Right-Pointing-Pointer The composite is potential for deposition of U, Th and its associate radionuclides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗