Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Impact of Heterogeneity-Based Dose Calculation Using a Deterministic Grid-Based Boltzmann Equation Solver for Intracavitary Brachytherapy

Purpose: To investigate the dosimetric impact of the heterogeneity dose calculation Acuros (Transpire Inc., Gig Harbor, WA), a grid-based Boltzmann equation solver (GBBS), for brachytherapy in a cohort of cervical cancer patients. Methods and Materials: The impact of heterogeneities was retrospectively assessed in treatment plans for 26 patients who had previously received {sup 192}Ir intracavitary brachytherapy for cervical cancer with computed tomography (CT)/magnetic resonance-compatible tandems and unshielded colpostats. The GBBS models sources, patient boundaries, applicators, and tissue heterogeneities. Multiple GBBS calculations were performed with and without solid model applicator, with and without overriding the patient contour to 1 g/cm{sup 3} muscle, and with and without overriding contrast materials to muscle or 2.25 g/cm{sup 3} bone. Impact of source and boundary modeling, applicator, tissue heterogeneities, and sensitivity of CT-to-material mapping of contrast were derived from the multiple calculations. American Association of Physicists in Medicine Task Group 43 (TG-43) guidelines and the GBBS were compared for the following clinical dosimetric parameters: Manchester points A and B, International Commission on Radiation Units and Measurements (ICRU) report 38 rectal and bladder points, three and nine o'clock, and {sub D2cm3} to the bladder, rectum, and sigmoid. Results: Points A and B, D{sub 2} cm{sup 3} bladder, ICRU bladder, and three and nine o'clock were within 5% of TG-43 for all GBBS calculations. The source and boundary and applicator account for most of the differences between the GBBS and TG-43 guidelines. The D{sub 2cm3} rectum (n = 3), D{sub 2cm3} sigmoid (n = 1), and ICRU rectum (n = 6) had differences of >5% from TG-43 for the worst case incorrect mapping of contrast to bone. Clinical dosimetric parameters were within 5% of TG-43 when rectal and balloon contrast were mapped to bone and radiopaque packing was not overridden. Conclusions: The GBBS has minimal impact on clinical parameters for this cohort of patients with unshielded applicators. The incorrect mapping of rectal and balloon contrast does not have a significant impact on clinical parameters. Rectal parameters may be sensitive to the mapping of radiopaque packing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of the Optimal Brachytherapy Utilization Rate in the Treatment of Gynecological Cancers and Comparison With Patterns of Care

Purpose: We aimed to estimate the optimal proportion of all gynecological cancers that should be treated with brachytherapy (BT)-the optimal brachytherapy utilization rate (BTU)-to compare this with actual gynecological BTU and to assess the effects of nonmedical factors on access to BT. Methods and Materials: The previously constructed inter/multinational guideline-based peer-reviewed models of optimal BTU for cancers of the uterine cervix, uterine corpus, and vagina were combined to estimate optimal BTU for all gynecological cancers. The robustness of the model was tested by univariate and multivariate sensitivity analyses. The resulting model was applied to New South Wales (NSW), the United States, and Western Europe. Actual BTU was determined for NSW by a retrospective patterns-of-care study of BT; for Western Europe from published reports; and for the United States from Surveillance, Epidemiology, and End Results data. Differences between optimal and actual BTU were assessed. The effect of nonmedical factors on access to BT in NSW were analyzed. Results: Gynecological BTU was as follows: NSW 28% optimal (95% confidence interval [CI] 26%-33%) compared with 14% actual; United States 30% optimal (95% CI 26%-34%) and 10% actual; and Western Europe 27% optimal (95% CI 25%-32%) and 16% actual. On multivariate analysis, NSW patients were more likely to undergo gynecological BT if residing in Area Health Service equipped with BT (odds ratio 1.76, P=.008) and if residing in socioeconomically disadvantaged postcodes (odds ratio 1.12, P=.05), but remoteness of residence was not significant. Conclusions: Gynecological BT is underutilized in NSW, Western Europe, and the United States given evidence-based guidelines. Access to BT equipment in NSW was significantly associated with higher utilization rates. Causes of underutilization elsewhere were undetermined. Our model of optimal BTU can be used as a quality assurance tool, providing an evidence-based benchmark against which actual patterns of practice can be measured. It can also be used to assist in determining the adequacy of BT resource allocation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for each patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher parotid doses for C-arm linear accelerator–based IMRT and RAPIDARC plans. Conclusion: Patient registry–based processes allowed easy and systematic dosimetric assessment of treatment plan quality and consistency. Our analysis revealed the dependence of certain dosimetric endpoints on the treatment techniques. Technique-specific refinement of planning goals may lead to improvement in plan consistency and plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Local-Regional Management Following Neoadjuvant Chemotherapy in Breast Cancer: Results From ACOSOG Z1071 (Alliance)

Purpose: American College of Surgeons Oncology Group Z1071 was a prospective trial evaluating the false negative rate of sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy (NAC) in breast cancer patients with initial node-positive disease. Radiation therapy (RT) decisions were made at the discretion of treating physicians, providing an opportunity to evaluate variability in practice patterns following NAC. Methods and Materials: Of 756 patients enrolled from July 2009 to June 2011, 685 met all eligibility requirements. Surgical approach, RT, and radiation field design were analyzed based on presenting clinical and pathologic factors. Results: Of 401 node-positive patients, mastectomy was performed in 148 (36.9%), mastectomy with immediate reconstruction in 107 (26.7%), and breast-conserving surgery (BCS) in 146 patients (36.4%). Of the 284 pathologically node-negative patients, mastectomy was performed in 84 (29.6%), mastectomy with immediate reconstruction in 69 (24.3%), and BCS in 131 patients (46.1%). Bilateral mastectomy rates were higher in women undergoing reconstruction than in those without (66.5% vs 32.2%, respectively, P<.0001). Use of internal mammary RT was low (7.8%-11.2%) and did not differ between surgical approaches. Supraclavicular RT rate ranged from 46.6% to 52.2% and did not differ between surgical approaches but was omitted in 193 or 408 node-positive patients (47.3%). Rate of axillary RT was more frequent in patients who remained node-positive (P=.002). However, 22% of patients who converted to node-negative still received axillary RT. Post-mastectomy RT was more frequently omitted after reconstruction than mastectomy (23.9% vs 12.1%, respectively, P=.002) and was omitted in 19 of 107 patients (17.8%) with residual node-positive disease in the reconstruction group. Conclusions: Most clinically node-positive patients treated with NAC undergoing mastectomy receive RT. RT is less common in patients undergoing reconstruction. There is wide variability in RT fields. These practice patterns conflict with expert recommendations and ongoing trial guidelines. There is a significant need for greater uniformity and guidelines regarding RT following NAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Health Economics in Radiation Oncology: A Systematic Review

Purpose: Despite the rising costs in radiation oncology, the impact of health economics research on radiation therapy practice analysis patterns is unclear. We performed a systematic review of cost-effectiveness analyses (CEAs) and cost-utility analyses (CUAs) to identify trends in reporting quality in the radiation oncology literature over time. Methods and Materials: A systematic review of radiation oncology economic evaluations up to 2014 was performed, using MEDLINE and EMBASE databases. The Consolidated Health Economic Evaluation Reporting Standards guideline informed data abstraction variables including study demographics, economic parameters, and methodological details. Tufts Medical Center CEA registry quality scores provided a basis for qualitative assessment of included studies. Studies were stratified by 3 time periods (1995-2004, 2005-2009, and 2010-2014). The Cochran-Armitage trend test and linear trend test were used to identify trends over time. Results: In total, 102 articles were selected for final review. Most studies were in the context of a model (61%) or clinical trial (28%). Many studies lacked a conflict of interest (COI) statement (67%), a sponsorship statement (48%), a reported study time horizon (35%), and the use of discounting (29%). There was a significant increase over time in the reporting of a COI statement (P<.001), health care payer perspective (P=.019), sensitivity analyses using multivariate (P=.043) or probabilistic methods (P=.011), incremental cost-effectiveness threshold (P<.001), secondary source utility weights (P=.010), and cost effectiveness acceptability curves (P=.049). There was a trend toward improvement in Tuft scores over time (P=.065). Conclusions: Recent reports demonstrate improved reporting rates in economic evaluations; however, there remains significant room for improvement as reporting rates are still suboptimal. As fiscal pressures rise, we will rely on economic assessments to guide our practice decisions and policies. We recommend improved adherence to published guidelines and further research to determine the clinical implications of our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Pattern of Use of Hypofractionated Radiation Therapy for Early-Stage Breast Cancer in New South Wales, Australia, 2008 to 2012

Purpose: Increasing phase 3 evidence has been published about the safety and efficacy of hypofractionated radiation therapy, in comparison with standard fractionation, in early-stage, node-negative breast cancer. However, uptake of hypofractionation has not been universal. The aim of this study was to investigate the hypofractionation regimen variations in practice across public radiation oncology facilities in New South Wales (NSW). Methods and Materials: Patients with early breast cancer registered in the NSW Clinical Cancer Registry who received radiation therapy for early-stage breast cancer in a publicly funded radiation therapy department between 2008 and 2012 were identified. Data extracted and analyzed included dose and fractionation type, patient age at first fraction, address (for geocoding), year of diagnosis, year of treatment, laterality, and department of treatment. A logistic regression model was used to identify factors associated with fractionation type. Results: Of the 5880 patients fulfilling the study criteria, 3209 patients (55%) received standard fractionation and 2671 patients (45%) received hypofractionation. Overall, the use of hypofractionation increased from 37% in 2008 to 48% in 2012 (range, 7%-94% across departments). Treatment facility and the radiation oncologist prescribing the treatment were the strongest independent predictors of hypofractionation. Weaker associations were also found for age, tumor site laterality, year of treatment, and distance to facility. Conclusions: Hypofractionated regimens of whole breast radiation therapy have been variably administered in the adjuvant setting in NSW despite the publication of long-term trial results and consensus guidelines. Some factors that predict the use of hypofractionation are not based on guideline recommendations, including lower rates of left-sided treatment and increasing distance from a treatment facility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Use of Hypofractionated Whole Breast Radiation in Breast Cancer: An Analysis of the National Cancer Database

Use of hypofractionated radiation (HR) as a component of breast-conserving treatment (BCT) in breast cancer is relatively low in the United States despite studies demonstrating its efficacy and guidelines supporting its use from the American Society for Radiation Oncology (ASTRO) in 2011 and 2018. Little is known regarding national trends in uptake and factors associated with uptake of HR in the US since the 2011 ASTRO guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mathematical test criteria for filtering complex systems: Plentiful observations

An important emerging scientific issue is the real time filtering through observations of noisy turbulent signals for complex systems as well as the statistical accuracy of spatio-temporal discretizations for such systems. These issues are addressed here in detail for the setting with plentiful observations for a scalar field through explicit mathematical test criteria utilizing a recent theory [A.J. Majda, M.J. Grote, Explicit off-line criteria for stable accurate time filtering of strongly unstable spatially extended systems, Proceedings of the National Academy of Sciences 104 (4) (2007) 1124-1129]. For plentiful observations, the number of observations equals the number of mesh points. These test criteria involve much simpler decoupled complex scalar filtering test problems with explicit formulas and elementary numerical experiments which are developed here as guidelines for filter performance. The theory includes information criteria to avoid filter divergence with large model errors, asymptotic Kalman gain, filter stability, and accurate filtering with small ensemble size as well as rigorous results delineating the role of various turbulent spectra for filtering under mesh refinement. These guidelines are also applied to discrete approximations for filtering the stochastically forced dissipative advection equation with very turbulent and noisy signals with either an equipartition of energy or -5/3 turbulent spectrum with infrequent observations as severe test problems. The theory and companion simulations demonstrate accurate statistical filtering in this context with implicit schemes with large time step with very small ensemble sizes and even with unstable explicit schemes under appropriate circumstances provided the filtering strategies are guided by the off-line theoretical criteria. The surprising failure of other strongly stable filtering strategies is also explained through these off-line criteria.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural and kinetic study of phase transitions in LaYSi{sub 2}O{sub 7}.

Phase transitions in LaYSi{sub 2}O{sub 7} have been investigated as a function of temperature using XRD, NMR and TEM. Previously described empirical crystal structure guidelines based on average cation radius in rare-earth RE{sub 2}Si{sub 2}O{sub 7}-type disilicates predict a stable tetragonal A-LaYSi{sub 2}O{sub 7} polymorph at temperatures below 1500 C. This study demonstrates that A-LaYSi{sub 2}O{sub 7} is not thermodynamically stable at these temperatures and suggests that guidelines based on average cation size do not accurately describe the equilibrium behaviour of this silicate system. The A to G-type polymorph transition is extremely sluggish; complete transformation requires {approx}250 h at 1200 C, and more than 3 weeks of calcination at 1100 C. This observation is important when this type of material is used as environmental barrier coating (EBC) of advanced ceramics. Analysis of XRD and TEM data reveal complete substitution of Y and La on the rare-earth cation sites in both LaYSi{sub 2}O{sub 7} polymorphs, but indicate preferential site occupancies in the G-type polymorph.

36 MATERIALS SCIENCE↗

Stability of Ba(Zr,Pr,Y)O{sub 3-{delta}} materials for potential application in electrochemical devices

Ba(Pr{sub 1-x}Zr{sub x}){sub 1-y}Y{sub y}O{sub 3-{delta}} materials were obtained by a two-step process of mechanical activation followed by annealing at 1250 {sup o}C. Guidelines for correlations between structure and composition, and their role on stability were characterised as a function of atmosphere, with special emphasis on degradation by carbonation in CO{sub 2}-rich atmospheres, or upon redox changes. The role of humidity on these degradation processes was also analysed by taking into account differences between wet and dry atmospheres with regards to the onset of secondary phases and structural changes. Thermodynamic calculations were used to predict 2-phase and 3-phase equilibria in contact with CO{sub 2}-rich atmospheres and to obtain corresponding stability diagrams. The thermodynamic calculations were also used as guidelines for the progress of carbonation in isothermal conditions, and also with variable temperature, namely on cooling carbonate free materials from high temperatures, or on re-heating under CO{sub 2}. -- Graphical abstract: The stability of Ba(Pr{sub 1-x}Zr{sub x}){sub 0.9}Y{sub 0.1}O{sub 3-{delta}} and Ba(Pr{sub 1-x}Zr{sub x}){sub 0.8}Y{sub 0.2}O{sub 3-{delta}} systems has been assessed in various atmospheres for 0{<=}x{<=}1. The figure shows that, by correct compositional selection, stability in reducing conditions can even extend to compositions containing high levels of Pr, such as Ba(Pr{sub 0.8}Zr{sub 0.2}){sub 0.8}Y{sub 0.2}O{sub 3-{delta}.} Display Omitted

36 MATERIALS SCIENCE↗

Controlled synthesis of titania using water-soluble titanium complexes: A review

The development of human society has led to the increase in energy and resources consumption as well as the arising problems of environmental damage and the toxicity to the human health. The development of novel synthesis method which tolerates utilization of toxic solvents and chemicals would fulfill the demand of the society for safer, softer, and environmental friendly technologies. For the past decades, a remarkable progress has been attained in the development of new water-soluble titanium complexes (WSTC) and their use for the synthesis of nanocrystalline titanium dioxide materials by aqueous solution-based approaches. The progress of synthesis of nanocrystalline titanium dioxide using such WSTCs is reviewed in this work. The key structural features responsible for the successfully controlled synthesis of TiO{sub 2} are discussed to provide guidelines for the morphology-controlled synthesis. Finally, this review ends with a summary and some perspectives on the challenges as well as new directions in this fascinating research. - Graphical abstract: The progress of synthesis of nanocrystalline titanium dioxide using water-soluble titanium complexes is reviewed in this work. The key structural features responsible for the successfully controlled synthesis of TiO{sub 2} are discussed to provide guidelines for the morphology-controlled synthesis. - Highlights: • The progress of the synthesis of novel water-soluble titanium complexes is reviewed. • Water-soluble titanium complexes are versatile precursor for synthesis of TiO{sub 2}. • The key structural features responsible for the controlled synthesis are discussed. • TiO{sub 2} with unusual shapes and complex patterns can be synthesized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of two intracavitary high-dose-rate brachytherapy devices for irradiating additional and irregularly shaped volumes of breast tissue

The SAVI and Contura breast brachytherapy applicators represent 2 recent advancements in brachytherapy technology that have expanded the number of women eligible for accelerated partial breast irradiation in the treatment of early-stage breast cancer. Early clinical experience with these 2 single-entry, multichannel high-dose-rate brachytherapy devices confirms their ease of use and dosimetric versatility. However, current clinical guidelines for SAVI and Contura brachytherapy may result in a smaller or less optimal volume of treated tissue compared with traditional interstitial brachytherapy. This study evaluates the feasibility of using the SAVI and Contura to irradiate larger and irregularly shaped target volumes, approaching what is treatable with the interstitial technique. To investigate whether additional tissue can be treated, 17 patients treated with the SAVI and 3 with the Contura were selected. For each patient, the planning target volume (PTV) was modified to extend 1.1 cm, 1.3 cm, and 1.5 cm beyond the tumor bed cavity. To evaluate dose conformance to an irregularly shaped target volume, 9 patients treated with the SAVI and 3 with the Contura were selected from the original 20 patients. The following asymmetric PTV margin combinations were assessed for each patient: 1.5/0.3, 1.3/0.3, and 1.1/0.3 cm. For all patients, treatment planning was performed, adopting the National Surgical Adjuvant Breast and Bowel Project guidelines, and dosimetric comparisons were made. The 6-1 and 8-1 SAVI devices can theoretically treat a maximal tissue margin of 1.5 cm and an asymmetric PTV with margins ranging from 0.3 to 1.5 cm. The 10-1 SAVI and Contura can treat a maximal margin of 1.3 cm and 1.1 cm, respectively, and asymmetric PTV with margins ranging from 0.3-1.3 cm. Compared with the Contura, the SAVI demonstrated greater dosimetric flexibility. Risk of developing excessive hot spots increased with the size of the SAVI device. Both the SAVI and Contura appear capable of treating >1.0-cm margins and irregularly shaped PTVs. The 6-1 SAVI device demonstrated the greatest versatility in targeting PTVs approaching what is treatable using the interstitial technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery

To retrospectively evaluate quality, efficiency, and delivery accuracy of volumetric-modulated arc therapy (VMAT) plans for single-fraction treatment of thoracic vertebral metastases using image-guided stereotactic body radiosurgery (SBRS) after RTOG 0631 dosimetric compliance criteria. After obtaining credentialing for MD Anderson spine phantom irradiation validation, 10 previously treated patients with thoracic vertebral metastases with noncoplanar hybrid arcs using 1 to 2 3D-conformal partial arcs plus 7 to 9 intensity-modulated radiation therapy beams were retrospectively re-optimized with VMAT using 3 full coplanar arcs. Tumors were located between T2 and T12. Contrast-enhanced T1/T2-weighted magnetic resonance images were coregistered with planning computed tomography and planning target volumes (PTV) were between 14.4 and 230.1 cc (median = 38.0 cc). Prescription dose was 16 Gy in 1 fraction with 6 MV beams at Novalis-TX linear accelerator consisting of micro multileaf collimators. Each plan was assessed for target coverage using conformality index, the conformation number, the ratio of the volume receiving 50% of the prescription dose over PTV, R50%, homogeneity index (HI), and PTV-1600 coverage per RTOG 0631 requirements. Organs-at-risk doses were evaluated for maximum doses to spinal cord (D{sub 0.03} {sub cc}, D{sub 0.35} {sub cc}), partial spinal cord (D{sub 10%}), esophagus (D{sub 0.03} {sub cc} and D{sub 5} {sub cc}), heart (D{sub 0.03} {sub cc} and D{sub 15} {sub cc}), and lung (V{sub 5}, V{sub 10}, and maximum dose to 1000 cc of lung). Dose delivery efficiency and accuracy of each VMAT-SBRS plan were assessed using quality assurance (QA) plan on MapCHECK device. Total beam-on time was recorded during QA procedure, and a clinical gamma index (2%/2 mm and 3%/3 mm) was used to compare agreement between planned and measured doses. All 10 VMAT-SBRS plans met RTOG 0631 dosimetric requirements for PTV coverage. The plans demonstrated highly conformal and homogenous coverage of the vertebral PTV with mean HI, conformality index, conformation number, and R{sub 50%} values of 0.13 ± 0.03 (range: 0.09 to 0.18), 1.03 ± 0.04 (range: 0.98 to 1.09), 0.81 ± 0.06 (range: 0.72 to 0.89), and 4.2 ± 0.94 (range: 2.7 to 5.4), respectively. All 10 patients met protocol guidelines with maximum dose to spinal cord (average: 8.83 ± 1.9 Gy, range: 5.9 to 10.9 Gy); dose to 0.35 cc of spinal cord (average: 7.62 ± 1.7 Gy, range: 5.4 to 9.6 Gy); and dose to 10% of partial spinal cord (average 6.31 ± 1.5 Gy, range: 3.5 to 8.5 Gy) less than 14, 10, and 10 Gy, respectively. For all 10 patients, the maximum dose to esophagus (average: 9.41 ± 4.3 Gy, range: 1.5 to 14.9 Gy) and dose to 5 cc of esophagus (average: 7.43 ± 3.8 Gy, range: 1.1 to 11.8 Gy) were kept less than protocol requirements 16 Gy and 11.9 Gy, respectively. In a similar manner, all 10 patients met protocol compliance criteria with maximum dose to heart (average: 4.62 ± 3.5 Gy, range: 1.3 to 10.2 Gy) and dose to 15 cc of heart (average: 2.23 ± 1.8 Gy, range: 0.3 to 5.6 Gy) less than 22 and 16 Gy, respectively. The dose to the lung was retained much lower than protocol guidelines for all 10 patients. The total number of monitor units was, on average, 6919 ± 1187. The average beam-on time was 11.5 ± 2.0 minutes. The VMAT plans demonstrated dose delivery accuracy of 95.8 ± 0.7%, on average, for clinical gamma passing rate with 2%/2 mm criteria and 98.3 ± 0.8%, on average, with 3%/3 mm criteria. All VMAT-SBRS plans were considered clinically acceptable per RTOG 0631 dosimetric compliance criteria. VMAT planning provided highly conformal and homogenous dose distributions for the lower-dose vertebral PTV and the spinal cord as well as organs-at-risk such as esophagus, heart, and lung. Higher QA pass rates and shorter beam-on time suggest that VMAT-SBRS is a clinically feasible, fast, and effective treatment option for patients with thoracic vertebral metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Integral Parameter Estimated Uncertainties in Fast Neutron Systems with COMMARA-2.1 and COMMARA-2.0 Covariance Data

This paper shows the main differences between the COMMARA-2.0 and COMMARA-2.1 evaluated covariance data in the uncertainty estimation of integral parameters of interest for a large number of typical innovative fast neutron systems. The study provides some guidelines to the nuclear data evaluators on which materials and which reaction types need to be evaluated most accurately to achieve reliable results in computational analyses of similar systems. The assessment of the quality and reliability of the covariance data is outside the scope of the study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a gamma-ray tracking array: A comparison of GRETINA and Gammasphere using a 60 Co source

In this paper, we provide a formalism for the characterization of the tracking arrays with emphasis on the proper corrections required to extract their photopeak efficiencies and peak-to-total ratios. The methods are first applied to Gammasphere, a well characterized 4pi array based on the principle of Compton suppression, and subsequently to GRETINA. The tracking efficiencies are then discussed and some guidelines as to what clustering angle to use in the tracking algorithm are presented. It was possible, using GEANT4 simulations, to scale the measured efficiencies up to the expected values for the full 4pi implementation of GRETA.

efficiency measurements↗