Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Fully "Eqwipped" to See the Heat

Developed by NASA's Jet Propulsion Laboratory over the past decade with an excess of $15 million of government research and development investment, quantum well infrared photodetectors (QWIPs) are infrared imaging sensors that can operate in the long wavelength portion of the electromagnetic spectrum, where objects at an ambient temperature emit the most energy. QWIPTECH was formed in July 1998 to offer JPL's QWIPs in a commercial format. The company currently holds an exclusive worldwide license to manufacture and sell the infrared photodetector sensors as part of a focal plane array called a QWIP Chip(TM). The QWIP Chip provides high thermal sensitivity (0.001 C) and possesses a broad dynamic range, permitting precise observations over a wide range of temperatures. Since the technology uses heat rather than light, it can "see" in complete darkness and through conditions such as dust, smoke, and light fog.

Source record↗

Spatial resolution enhancement of terrestrial features using deconvolved SSM/I microwave brightness temperatures

A method for enhancing the 19, 22, and 37 GHz measurements of the SSM/I (Special Sensor Microwave/Imager) to the spatial resolution and sampling density of the high resolution 85-GHz channel is presented. An objective technique for specifying the tuning parameter, which balances the tradeoff between resolution and noise, is developed in terms of maximizing cross-channel correlations. Various validation procedures are performed to demonstrate the effectiveness of the method, which hopefully will provide researchers with a valuable tool in multispectral applications of satellite radiometer data.

Farrar, Michael R.↗

Surface-Wind Anomalies in North-Atlantic and North Pacific from SSM/I Observations: Influence on Temperature of Adjoining Land Regions

Surface winds over the oceans are derived from Special Sensor Microwave Imager (SSM/I) measurements, assigning direction by Variational Analysis Method (VAM). Validations by comparison with other measurements indicate highly-satisfactory data quality. Providing global coverage from 1988, the dataset is a convenient source for surface-wind climatology. In this study, the interannual variability of zonal winds is analyzed concentrating on the westerlies in North Atlantic and North Pacific, above 30 N. Interannual differences in the westerlies exceeding 10 m sec (exp -1) are observed over large regions, often accompanied by changes of the same magnitude in the easterlies below 30 N. We concentrate on February/March, since elevated temperatures, by advancing snow-melt, can produce early spring. The extremely strong westerlies in 1997 observed in these months over North Atlantic (and also North Pacific) apparently contributed to large surface-temperature anomalies in western Europe, on the order of +3 C above the climatic monthly average for England and France. At these latitudes strong positive anomalies extended in a ring around the globe. We formulated an Index of South westerlies for the North Atlantic, which can serve as an indicator for day-by-day advection effects into Europe. In comparing 1997 and 1998 with the previous years, we establish significant correlations with the temperature anomalies (one to five days later, depending on the region, and on the season). This variability of the ocean-surface winds and of the temperature anomalies on land may be related to the El Nino/La Nina oscillations. Such large temperature fluctuations over large areas, whatever the cause, can be regarded as noise in attempts to assess long-term trends in global temperature.

Otterman, Joseph↗

Testing piezoelectric sensors in a nuclear reactor environment

Several Department of Energy Office of Nuclear Energy (DOE-NE) programs, such as the Fuel Cycle Research and Development (FCRD), Advanced Reactor Concepts (ARC), Light Water Reactor Sustainability, and Next Generation Nuclear Power Plants (NGNP), are investigating new fuels, materials, and inspection paradigms for advanced and existing reactors. A key objective of such programs is to understand the performance of these fuels and materials during irradiation. In DOE-NE’s FCRD program, ultrasonic based technology was identified as a key approach that should be pursued to obtain the high-fidelity, high-accuracy data required to characterize the behavior and performance of new candidate fuels and structural materials during irradiation testing. The radiation, high temperatures, and pressure can limit the available tools and characterization methods. In this work piezoelectric transducers capable of making these measurements are developed. Specifically, three piezoelectric sensors (Bismuth Titanate, Aluminum Nitride, and Zinc Oxide) are tested in the Massachusetts Institute of Technology Research reactor to a fast neutron fluence of 8.65x1020 nf/cm2. It is demonstrated that Bismuth Titanate is capable of transduction up to 5 x1020 nf/cm2, Zinc Oxide is capable of transduction up to at least 6.27 x1020 nf/cm2 , and Aluminum Nitride is capable of transduction up to at least 8.65x x1020 nf/cm2.

T. Reinhardt, Brian↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Venus Surface Wind Sensor Based on a Miniature Drag-Force Anemometer

To better understand the atmospheric structure and dynamics on the Venus surface and provide input to climate models, there is a need to measure the wind velocity and direction on the surface and track changes over extended periods. A wind sensor based on a miniature drag-force anemometer is being developed to meet the challenges for wind measurements and operational requirements on the surface of Venus. The sensor materials are chosen to enhance durability and prevent reactivity with the Venus surface atmosphere. Advantages of this approach include that it is independent on variable heat transfer, has been matured in other harsh environment applications,and has a low mass and power requirement. This report describes demonstration of this miniature drag-force anemometer integrated with high temperature electronics in simulated Venus surface environment. Prototype drag-force anemometers were demonstrated integrated with an operational amplifier recording transient effects in a simulated Venus surface environment. For multidirectional wind monitoring, the sensors are small enough to be deployed orthogonally as a three-dimensional array on a small arm or mast

wind measurement↗

Experimental and Numerical Characterization of High Heat Fluxes During Transient Blackbody Calibrations

High heat fluxes are encountered in numerous applications, such as hypersonic vehicles in flight, fires, and engines, Calibration of heat flux gages may be performed in a dual cavity cylindrical blackbody resulting in a transient calibration environment. To characterize the transient heat fluxes. experiments were performed on a dual cavity cylindrical blackbody at nominal temperatures varying from 800 C to 1900 C in increments of 100 C. Based on experiments, the optimum heat flux sensor insertion location as measured from the center partition was determined. The pre-insertion steady state axial temperature profile is compared experimentally, numerically, and analytically. The effect of convection in the blackbody cavity during the insertion is calculated and found to be less than 2 per cent. Also, an empirical correlation for predicting the emissivity of the blackbody is included. Detailed transient thermal models have been developed to simulate the heat flux calibration process at two extreme fluxes. The high (1MW/sq m) and relatively low (70 kw/sq m) fluxes are reported in this article. The transient models show the effect of inserting a heat flux gage at room temperature on the thermal equilibrium of the blackbody at 1800 C and 800 C nominal temperatures, respectively. Also, heat flux sensor outputs are derived from computed sensor temperature distributions and compared to experimental results.

Abdelmessih, Amanie N.↗

Addressing a systematic bias in carbon dioxide flux measurements with the EC150 and the IRGASON open-path gas analyzers

Across a global network of eddy covariance flux towers, two relatively new open-path infrared gas analyzers (IRGAs), the IRGASON and the EC150, are increasingly used to measure net carbon dioxide (CO 2 ) fluxes (F c_OP ). Differences in net CO 2 fluxes derived from open- and closed-path IRGAs in general remain poorly constrained. In particular, the performance of the IRGASON and the EC150 for measuring F c_OP has not been characterized yet. These IRGAs measure CO 2 absorption, which is scaled with air temperature and pressure before converting it to instantaneous CO 2 density. This sensor-internal conversion is based on a slow-response thermistor air temperature measurement. In this paper, we test if the high-frequency temperature attenuation causes selectively systematic F c_OP errors that scale with kinematic temperature fluxes. First, we examine the relationship between wintertime F c_OP and kinematic temperature fluxes for eight northern ecosystems. Second, we investigate how residuals between F c_OP and CO 2 fluxes from co-located closed-path IRGAs (F C_CP ) are related to kinematic temperature fluxes for three different ecosystem types (i.e., boreal forest, grassland, and irrigated cropland). We find that kinematic temperature fluxes, but not mean ambient air temperatures or CO 2 flux regime, consistently determine the absolute magnitude of F c_OP errors. This selectively systematic bias causes the most pronounced relative F c_OP errors to occur when “true” CO 2 fluxes are low and kinematic temperature fluxes are high (e.g., northern ecosystems during the winter). The smallest relative errors occur during periods with large “true” CO 2 fluxes and low kinematic temperature fluxes. To address this bias, we replace the slow-response air temperature in the absorption-to-CO 2 density conversion with a fast-response air temperature derived from sonic anemometer measurements. The use of the fast-response air temperature improves the agreement between half-hourly F c_OP and F C_CP for all open- versus closed-path IRGA comparisons. Additionally, cumulative F c_OP and F c_CP sums are more comparable as differences drop from 63 %–13 % to 20 %–8 %. Finally, the improved IRGASON and EC150 performance enhances the ability and confidence to synthesize flux measurements across multiple sites including these two relatively new IRGAs.

47 OTHER INSTRUMENTATION↗

Energetics of high temperature degradation of fentanyl into primary and secondary products

Fentanyl is a synthetic opioid used for managing chronic pain. Due to its higher potency (50–100×) than morphine, fentanyl is also an abused drug. A sensor that could detect illicit fentanyl by identifying its thermally degraded fragments would be helpful to law enforcement. While experimental studies have probed the thermal degradation of fentanyl, little theoretical work has been done to understand the mechanism. Here, we studied the thermal degradation pathways of fentanyl using extensive ab initio molecular dynamics simulations combined with enhanced sampling via multiple-walker metadynamics. We calculated the free energy profile for each bond suggested earlier as a potential degradation point to map the thermodynamic driving forces. In conclusion, we also estimated the forward attempt rate of each bond degradation reaction to gain information about degradation kinetics.

Poudel, Bharat↗

A mini-review on proton conduction of BaZrO 3 -based perovskite electrolytes

Abstract Proton conducting ceramics show promise in fuel cells, electrolyzers, permeation membranes, sensor applications, and membrane reactors. Among several types of materials that exhibit proton conduction, perovskite oxides show high proton conductivity at intermediate temperatures, presenting potential benefits for long-term use and lower costs for energy applications. Doped barium zirconate, BaZrO 3 , is a material that has shown high proton conductivity with encouraging chemical stability. Therefore, it is considered a promising material especially for proton-conducting solid oxide electrochemical cells. Although the proton conduction of doped BaZrO 3 has been extensively characterized, the specific phenomena behind its proton conduction are not fully understood. Only recently have specialized techniques and computational tools begun to elucidate the phenomena that determine the conduction properties of the material. In this mini review, an evaluation of the factors affecting the proton conductivity of doped BaZrO 3 perovskites and the phenomena governing variations in proton concentration and mobility are presented. Special attention is given to proton interactions with dopants and their resulting effect on hydration and transport properties. Technical strategies are provided to give some guidance on the development of protonic ceramics in energy conversion applications.

08 HYDROGEN↗

Battery Monitoring System

The component that is powered by the battery pack being monitored is a valuable asset and must be in working condition at all times. Battery chemistry and characteristics have a major role in how to evaluate the state of the battery. The battery monitoring system has many parts that lead to an accurate battery reading. The components consist of a coulomb counting device, end of life voltage detection, a consideration of use for a real-time clock (RTC), temperature sensor, and non-volatile random-access memory (NVRAM). The combination of these elements allows the monitoring system to be highly reliant. Moving forward a better implementation of the ideas in this paper and further testing should ensure a high-quality battery monitoring system.

25 ENERGY STORAGE↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

Leveraging Optimal Sparse Sensor Placement to Aggregate a Network of Digital Twins for Nuclear Subsystems

Nuclear power plants (NPPs) require continuous monitoring of various systems, structures, and components to ensure safe and efficient operations. The critical safety testing of new fuel compositions and the analysis of the effects of power transients on core temperatures can be achieved through modeling and simulations. They capture the dynamics of the physical phenomenon associated with failure modes and facilitate the creation of digital twins (DTs). Accurate reconstruction of fields of interest (e.g., temperature, pressure, velocity) from sensor measurements is crucial to establish a two-way communication between physical experiments and models. Sensor placement is highly constrained in most nuclear subsystems due to challenging operating conditions and inherent spatial limitations. This study develops optimized data-driven sensor placements for full-field reconstruction within reactor and steam generator subsystems of NPPs. Optimized constrained sensors reconstruct field of interest within a tri-structural isotropic (TRISO) fuel irradiation experiment, a lumped parameter model of a nuclear fuel test rod and a steam generator. The optimization procedure leverages reduced-order models of flow physics to provide a highly accurate full-field reconstruction of responses of interest, noise-induced uncertainty quantification and physically feasible sensor locations. Accurate sensor-based reconstructions establish a foundation for the digital twinning of subsystems, culminating in a comprehensive DT aggregate of an NPP.

42 ENGINEERING↗

Hot wire anemometry in transonic flow

The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds numbers greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conclusions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Examples of these measurements are presented for two transonic boundary layers.

Horstman, C. C.↗

Hot-wire anemometry in transonic flow

The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds number greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conditions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Example of these measurements are presented for two transonic boundary layers.

Horstman, C. C.↗

Improved 02/H2 Gas Mixture Sensor

Monitor of mixture concentrations uses catalyzed and uncatalyzed temperature probe. Sensor includes Pt-catalyzed temperature probe mounted in line with similar uncatalyzed temperature probe. Use of common temperature probes and standard, flareless, high-pressure tubefittings resulted in design conductive to installation in almost any system. Suitable for use in regenerative fuel cells, life-support systems, and other closed systems.

Moulthrop, L. C.↗

Operation of a multi-year, multi-agency project

Organizational and technological aspects of the operation by NASA and ESA of the IUE satellite observatory since its launch in 1978 are discussed. Topics addressed include the division of responsibilities among the ground stations, the IUE orbit and its evolution, the IUE spacecraft, normal operations (proposal selection and observation planning, shift handover, and spacecraft operations), and a typical observation (target identification and acquisition, telescope focus, spectrograph modes, camera operations, calibration, and data reduction). Consideration is given to constraints on IUE operation due to the sun-earth-moon configuration (eclipses), spacecraft power, radiation, temperature, and momentum-wheel speed; problems encountered with gyros, onboard computers, the fine sun sensor, and cameras; and the reliable high-efficiency overall performance of the IUE. Diagrams, drawings, and graphs are provided.

Faelker, Juergen↗