At least 1,333 records · Page 74

Magnetic and microwave properties of U-type hexaferrite films with high remanence and low ferromagnetic resonance linewidth

U-type barium hexaferrite films (Ba{sub 4}Ni{sub 1.4}Co{sub 0.6}Fe{sub 36}O{sub 60}) were deposited on (0001) sapphire substrates by pulsed laser deposition. Microstructure and magnetic properties of the films were characterized by X-ray diffraction, scanning electron microscopy and vibrating sample magnetometry. Ferromagnetic resonance (FMR) measurements were performed at X-band. The results indicate an anisotropy field of ∼8 kOe, and the saturation magnetization (4πM{sub s}) of ∼3.6 kG. An optimal post-deposition annealing of films results in a strong (0 0 n) crystallographic texture and a high hysteresis loop squareness (M{sub r}/M{sub s} = 92%) leading to self biased properties. Furthermore, the highly self-biased ferrite films exhibited an FMR linewidth of ∼200 Oe. The U-type hexaferrite films having low microwave loss, low magnetic anisotropy field, and high squareness are a suitable alternative to Sc or In doped BaM ferrites that have been the choice material for self-biased microwave devices at X-band frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photostability Can Be Significantly Modulated by Molecular Packing in Glasses

While previous work has demonstrated that molecular packing in organic crystals can strongly influence photochemical stability, efforts to tune photostability in amorphous materials have shown much smaller effects. Here we show that physical vapor deposition can substantially improve the photostability of organic glasses. Disperse Orange 37 (DO37), an azobenzene derivative, is studied as a model system. Photostability is assessed through changes in the density and molecular orientation of glassy thin films during light irradiation. By optimizing the substrate temperature used for deposition, we can increase photostability by a factor of 50 relative to the liquid-cooled glass. Photostability correlates with glass density, with density increases of up to 1.3%. Coarse-grained molecular simulations, which mimic glass preparation and the photoisomerization reaction, also indicate that glasses with higher density have substantially increased photostability. These results provide insights that may assist in the design of organic photovoltaics and light emission devices with longer lifetimes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trapping in irradiated p + -n-n - silicon sensors at fluences anticipated at the HL-LHC outer tracker

The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200μm thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 3 x 10 15 neq/cm 2 . Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. Furthermore, the effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photostability can be significantly modulated by molecular packing in glasses

While previous work has demonstrated that molecular packing in organic crystals can strongly influence photochemical stability, efforts to tune photostability in amorphous materials have shown much smaller effects. Here we show that physical vapor deposition can substantially improve the photostability of organic glasses. Disperse Orange 37 (DO37), an azobenzene derivative, is studied as a model system. Photostability is assessed through changes in the density and molecular orientation of glassy thin films during light irradiation. By optimizing the substrate temperature used for deposition, we can increase photostability by a factor of 50 relative to the liquid-cooled glass. Photostability correlates with glass density, with density increases of up to 1.3%. Coarse-grained molecular simulations, which mimic glass preparation and the photoisomerization reaction, also indicate that glasses with higher density have substantially increased photostability. These results provide insights that may assist in the design of organic photovoltaics and light emission devices with longer lifetimes.

36 MATERIALS SCIENCE↗

Plasma Emission, Wave Speeds, and Temperatures of Laser-Supported Plasmas in Air

A study of the generation and subsequent expansion of plasmas using a single beam (532 nm) from the second harmonic generator of a Q-switched Nd:YAG laser is described. The plasmas in air are studied using an intensified charge-coupled device camera over periods of 1000 ns following the laser pulses. The plasma experimental results are interpreted in terms of wave speeds and plasma temperatures. Energy balance equations are considered to estimate the plasma temperatures and the laser-supported radiation (LSR) and the laser-supported detonation (LSD) wave speeds. Within 1000 ns observation time, the circular spectral images turn elliptical because of plasma expansion toward the laser beam. The plasma expansion increases with increasing laser irradiance. A laser irradiance range of [Formula: see text] yields LSR wave speeds between 45 and 170 km/s and LSD wave speeds of 90–130 km/s. The measured wave speeds are compared with the LSR and the LSR wave speed models. The plasma temperatures are between 90,000 and 120,000 K at 15 ns after the laser pulse based on measured emission spectra and are between 640,000 and 760,000 K at 3 ns based on the LSR model.

Engineering↗

Femtosecond Laser-Induced Nano-Joining of Volatile Tellurium Nanotube Memristor

Nanowire/nanotube memristor devices provide great potential for random-access high-density resistance storage. However, fabricating high-quality and stable memristors is still challenging. This paper reports multileveled resistance states of tellurium (Te) nanotube based on the clean-room free femtosecond laser nano-joining method. The temperature for the entire fabrication process was maintained below 190 °C. A femtosecond laser joining technique was used to form nanowire memristor units with enhanced properties. Femtosecond (fs) laser-irradiated silver-tellurium nanotube-silver structures resulted in plasmonic-enhanced optical joining with minimal local thermal effects. This produced a junction between the Te nanotube and the silver film substrate with enhanced electrical contacts. Noticeable changes in memristor behavior were observed after fs laser irradiation. Capacitor-coupled multilevel memristor behavior was observed. Compared to previous metal oxide nanowire-based memristors, the reported Te nanotube memristor system displayed a nearly two-order stronger current response. The research displays that the multileveled resistance state is rewritable with a negative bias.

42 ENGINEERING↗

A study of charged particles/radiation damage to VLSI device materials

Future spacecraft systems such as the manned space station will be subjected to low-dose long term radiation particles. Most electronic systems are affected by such particles. There is therefore a great need to understand device physics and failure mechanisms affected by radiation and to design circuits that would be less susceptible to radiation. Using 2 MeV electron radiation and bias temperature aging, it was found that MOS capacitors that were prepositively biased have lower flatband voltage shift and lesser increase in density of surface state charge than those that were not prepositively biased. In addition, it was shown that there is continued recovery of flatband voltage and density of state charge in irradiated capacitors during both room temperature anneal and 137 degree anneal. When nMOS transistors were subjected to 1 MeV proton radiation, charge pumping and current versus voltage measurements indicated that transconductance degradation, threshold voltage shifts and changes in interface states density may be the primary cause of nMOS transistor failure after radiation. Simulation studies using SPICE were performed on CMOS SRAM cells of various transistor sizes. It is shown that transistor sizing affects the noise margins of CMOS SRAM cells, and that as the beta ratio of the transistors of the CMOS SRAM cell decreases, the effective noise margin of the SRAM cell increases. Some suggestions were made in connection with the design of CMOS SRAMS that are hardened against single event upsets.

Okyere, John G.↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗

Method to Assess the Radionuclide Inventory of Irradiated Graphite from Gas-Cooled Reactors - 13072

About 17,000 t of irradiated graphite waste will be produced from the decommissioning of the six French gas-cooled nuclear reactors. Determining the radionuclide (RN) content of this waste is of relevant importance for safety reasons and in order to determine the best way to manage them. For many reasons the impurity content that gave rise to the RNs in irradiated graphite by neutron activation during operation is not always well known and sometimes actually unknown. So, assessing the RN content by the use of traditional calculation activation, starting from assumed impurity content, leads to a false assessment. Moreover, radiochemical measurements exhibit very wide discrepancies especially on RN corresponding to precursor at the trace level such as natural chlorine corresponding to chlorine 36. This wide discrepancy is unavoidable and is due to very simple reasons. The level of impurity is very low because the uranium fuel used at that very moment was not enriched, so it was a necessity to have very pure nuclear grade graphite and the very low size of radiochemical sample is a simple technical constraint because device size used to get mineralization product for measurement purpose is limited. The assessment of a radionuclide inventory only based on few number of radiochemical measurements lead in most cases, to a gross over or under-estimation that is detrimental for graphite waste management. A method using an identification calculation-measurement process is proposed in order to assess a radiological inventory for disposal sizing purpose as precise as possible while guaranteeing its upper character. This method present a closer approach to the reality of the main phenomenon at the origin of RNs in a reactor, while also incorporating the secondary effects that can alter this result such as RN (or its precursor) release during reactor operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Ultraviolet Photons to Generate Single-Photon Emitters in Semiconductor Monolayers

The understanding and controlled creation of atomic defects in semiconductor transition metal dichalcogenides (TMDs) are highly relevant to their applications in high-performance quantum optics and nanoelectronic devices. Here, we demonstrate a versatile approach in generating single-photon emitters in MoS 2 monolayers using widely attainable UV light. We discover that only defects engendered by UV photons in vacuum exhibit single-photon-emitter characteristics, whereas those created in air lack quantum emission attributes. In combination with theoretical calculations, we assign the defects generated in vacuum to unpassivated sulfur vacancies, whose highly localized midgap states give rise to single-photon emission. In contrast, UV irradiation of the MoS 2 monolayers in air results in oxygen-passivated sulfur vacancies, whose optical properties are likely governed by their pristine band-to-defect band optical transitions. Furthermore, these findings suggest that widely available light sources such as UV light can be utilized for creating quantum photon sources in TMDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

TU-H-209-00: Planning and Delivering HDR APBI Treatments

Learnings Objectives: Although brachytherapy is the oldest form of radiation therapy, the rapid advancement of the methods of dose calculation, treatment planning and treatment delivery pushes us to keep updating our knowledge and experience to new procedures all the time. Our purpose is to present the newest applicators used in Accelerated Partial Breast Irradiation (APBI) and the techniques of using them for a maximum effective treatment. Our objective will be to get the user familiar with the Savi, Contura and ML Mammosite from the detailed description and measurements to cavity eval and choice or size, to acceptance tests and use of each. At the end of the session the attendants will be able to assist at the scanning of the patient for the first treatment, decide on the proper localization and immobilization devices, import the scans in the treatment planning system, perform the structure segmentation, reconstruct the catheters and develop a treatment plan using inverse planning (IPSA) or volume optimization. The attendant should be able to evaluate the quality of a treatment plan according to the ABS protocols and B39 after this session. Our goal is that all the attendants to gain knowledge of all the quality assurance procedures required to be performed prior to a treatment, at the beginning of a treatment day, weekly, monthly and annualy on the remote afterloader, the treatment planning system and the secondary check system. We will provide tips for a consistent treatment delivery of the 10 fractions in a BID (twice daily) regimen.

60 APPLIED LIFE SCIENCES↗

Fabrication of Silicon Sensors Based on Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes are a recently-developed class of silicon sensors. Characterized by an internal moderate gain that enhances the signal amplitude and if built on thin silicon substrates of a few tens of microns, they feature fast signals and exhibit excellent timing performance. Thanks to their fast timing they are planned to be exploited in timing detectors in High-Energy Physics experiments, for example for the upgrades of the ATLAS and CMS detectors at the High Luminosity Large Hadron Collider (HL-LHC) at CERN. However, to achieve a spatially uniform multiplication a large pixel pitch is needed, preventing a fine spatial resolution. To overcome this limitation, the AC-coupled LGAD approach was introduced. In this type of device, metal electrodes are placed over an insulator at a fine pitch, and signals are capacitively induced on these electrodes. The fabrication technology is similar for the two LGAD families, although a fine tuning of a few process parameters needs to be carefully studied. Other R&D efforts towards detectors that can simultaneously provide good time and spatial resolution, based on the LGAD concept, are under way. These efforts aim also to mitigate the loss of performance at high irradiation fluences due to the acceptor removal within the gain layer. In this paper we describe the main points in the fabrication of LGADs and AC-LGADs in a clean-room. We also discuss novel efforts carried on related topics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation and Thermal Cycling Effects on EPC1001 Gallium Nitride Power Transistors

Electronics designed for use in NASA space missions are required to work efficiently and reliably under harsh environment conditions. These include radiation, extreme temperatures, and thermal cycling, to name a few. Information pertaining to performance of electronic parts and systems under hostile environments is very scarce, especially for new devices. Such data is very critical so that proper design is implemented in order to ensure mission success and to mitigate risks associated with exposure of on-board systems to the operational environment. In this work, newly-developed enhancement-mode field effect transistors (FET) based on gallium nitride (GaN) technology were exposed to various particles of ionizing radiation and to long-term thermal cycling over a wide temperature range. Data obtained on control (un-irradiated) and irradiated samples of these power transistors are presented and the results are discussed.

Patterson, Richard L.↗

Effects of combined current injection and laser irradiation on Permalloy microwire switching

Combined field- and current-induced domain wall (DW) motion in Permalloy microwires is studied using fast magneto-optical Kerr-microscopy. On increasing the current density, we find a decrease of Kerr signal contrast, corresponding to a reduction in the magnetization, which is attributed to Joule heating of the sample. Resistance measurements on samples with varying substrates confirm that the Curie temperature is reached when the magneto-optical contrast vanishes and reveal the importance of the heat flow into the substrate. By tuning the laser power, DWs can be pinned in the laser spot, which can thus act as a flexible pinning site for DW devices.

36 MATERIALS SCIENCE↗

Calcium manganate: A promising candidate as buffer layer for hybrid halide perovskite photovoltaic-thermoelectric systems

We have systematically studied the feasibility of CaMnO{sub 3} thin film, an n-type perovskite, to be utilized as the buffer layer for hybrid halide perovskite photovoltaic-thermoelectric device. Locations of the conduction band and the valence band, spontaneous polarization performance, and optical properties were investigated. Results indicate the energy band of CaMnO{sub 3} can match up well with that of CH{sub 3}NH{sub 3}PbI{sub 3} on separating electron-hole pairs. In addition, the consistent polarization angle helps enlarge the open circuit voltage of the composite system. Besides, CaMnO{sub 3} film shows large absorption coefficient and low extinction coefficient under visible irradiation, demonstrating high carrier concentration, which is beneficial to the current density. More importantly, benign thermoelectric properties enable CaMnO{sub 3} film to assimilate phonon vibration from CH{sub 3}NH3PbI{sub 3}. All the above features lead to a bright future of CaMnO{sub 3} film, which can be a promising candidate as a buffer layer for hybrid halide perovskite photovoltaic-thermoelectric systems.

36 MATERIALS SCIENCE↗

LEEM investigations of clean surfaces driven by energetic ion beams

he original purpose of this award was to use low-energy electron microscopy (LEEM) to explore the dynamics of surfaces of clean single crystal surfaces when driven by a beam of energetic ions. The goal was to understand the nanoscience of hyperthermal growth, surface erosion by sublimation and irradiation, operation of surface sinks in irradiated materials, diffusion on driven surfaces, and the creation of structural patterns. This project was based on a novel LEEM system constructed by C. P. Flynn, which provided real-time imaging of surface dynamics by scattering low energy electrons. With the passing of Prof. Flynn in late 2011, this project was completed under a slightly different scope by constructing a low-energy, inelastic electron scattering (“EELS”) instrument. Consistent with Flynn’s original objectives for his LEEM system, this device (shown in Fig. 1) probes the dynamics of crystal surfaces. However the measurements are not carried out in real time, but instead are done in the frequency domain, through the energy lost from the probe electrons. The purpose of this device is to study the collective bosonic excitations in a variety of materials, including high temperature superconductors, topological insulators, carbon allotropes including (but not limited to) graphene, etc. The ultimate goal here is to identify the bosons that mediate interactions in these and other materials, with hopes of shedding light on the origin of many exotic phenomena including high temperature superconductivity.

36 MATERIALS SCIENCE↗

Investigating Sintering Mechanisms for Additive Manufacturing of Conductive Traces

Additive Manufacturing (AM) processes enable the fabrication of miniaturized and flexible devices on complex geometries. This paper explores a hybrid additive manufacturing technology that integrates micro-extrusion and PICO-jetting methods. Conductive slurries and colloidal inks were optimized for their rheological properties to aid their precise deposition. A variety of conductive materials which include carbon, silver, nano-particle silver and nickel were deposited on both rigid (glass) and flexible (Kapton) substrates. The deposited traces were cured using two sintering mechanisms which include furnace heating and in situ laser irradiation. The effect of curing mechanism on the conductance of deposited traces was evaluated. The results indicated that traces could be cured successfully with the laser curing mechanism. Nickel and silver laser cured traces had lower resistivity than the furnace sintered traces. An increase in the laser power resulted in lower resistivity of the traces. The lowest resistivity was achieved at 40W laser power with a single laser pass. Scanning electron microscopy and energy dispersive spectroscopy were used to characterize the trace morphology and elemental compositions. Higher power laser curing resulted in better bonding of the particles. Laser cured samples had minimal oxidation to the cross-section region of the traces as compared to furnace cured samples. Furthermore, this research lays the foundation for the fabrication of electronic components for a high level of freeform 3D electronics using a hybrid additive manufacturing technology.

42 ENGINEERING↗