Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Discrepancy in the Critical State Void Ratio of Poorly Graded Sand due to Shear Strain Localization

The critical state (CS) concept is a theoretical framework that models the constitutive behavior of soils, including sand and other granular materials. It supports the notion of a unique postfailure state, where the soil ultimately experiences continuous shearing with no change in the plastic volumetric strain. However, the published literature has frequently noted the nonconvergence of sand specimens with different initial densities to a unique CS in the compression plane due to many factors such as specimen fabric, particle morphology, breakage, and grain size distribution. This paper examines the CS for poorly graded (uniform) glass beads and 3 different types of silica sands using 50 conventional triaxial compression (CTC) experiments, 12 oedometer tests, and in situ synchrotron microcomputed tomography (SMT) scans for 10 CTC experiments. The results of the 50 CTC experiments revealed a diffused CS zone in the compression plane, which was further examined using the in situ SMT scans. A thorough three-dimensional image analysis of the SMT scans accurately quantified the evolution of the local void ratio (elocal) versus axial compression within zones of intensive shearing toward the center of the specimen. The evolution of the void ratio was also measured using the entire volume of the specimen (eglobal). At the CS, the elocal/eglobal ratio was assessed to be ~1.25 when a single shear band developed within the scanned specimens and ~1.1-1.15 for specimens that failed via external bulging that was internally manifested by the development of multiple shear bands. This finding suggests that the CS zone in the compression plane can be attributed to the common wrong consideration of eglobal evolution in lieu of elocal within the developing shear bands. Furthermore, the lack of shear band development in uniaxial compression has made the results of the oedometer test reliable in quantifying the CS parameters in the compression plane.

58 GEOSCIENCES↗

X-Ray Microtomography Measurements of Coevolving Particle Size and Shape

This study measures simultaneous changes in particle size and shape during grain crushing and proposes quantitative metrics to track their coevolving statistical distribution. Idealized granular materials with widely different initial particle shapes (i.e., spheres, quasi-ellipsoids, plates, and rods) are compressed oedometrically at vertical stress levels sufficient to induce particle breakage. X-ray microtomography and digital image analysis are then used to track changes in particle-scale characteristics. The observations indicate that more irregular particles tend to exhibit a higher degree of breakage compared to more spherical grains subjected to an equivalent stress level. Despite these differences, the measurements also indicate that all the tested particle sets approach a common attractor (expressed in terms of aspect ratio, flatness, and elongation), regardless of their initial morphology. A new shape evolution index is proposed to quantify such trends. With this new metric, it is shown that in all the tested materials, the particle shape evolves faster than size, especially for the more regular morphologies, thus implying that the shape tends to reach its attractor point before the grading reaches its ultimate particle size distribution. Furthermore, this finding underpins an ultimate stage of crushing-driven compression that occurs with particle size reduction but minimal shape changes (i.e., self-replicating shapes due to fractures).

Oedometric compression↗

Morphology and hardness ratio exploitation under limited statistics

{gamma}-ray astronomy has produced for several years now sky maps for low photon statistics, non-negligible background and comparatively poor angular resolution. Quantifying the significance of spatial features remains difficult. Besides, spectrum extraction requires regions with large statistics while maps in energy bands allow only qualitative interpretation. The two main competing mechanisms in the VHE domain are the Inverse-Compton emission from accelerated electrons radiating through synchrotron in the X-ray domain and the interactions between accelerated hadrons and the surrounding medium, leading to the production and subsequent decay of {pi}{sup 0} mesons. The spectrum of the VHE emission from leptons is predicted to steepen with increasing distance from the acceleration zone, owing to synchrotron losses (i.e. cooled population). It would remain approximately constant for hadrons.Ideally, spectro-imaging analysis would have the same spatial scale in the TeV and X-ray domains, to distinguish the local emission mechanisms. More realistically, we investigate here the possibility of improving upon the currently published HESS results by using more sophisticated tools.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher-Order Optical Modes and Nanostructures for Detection and Imaging Applications

Raman spectroscopy offers a label-free, chemically specific, method of detecting molecules; however, the low cross-section attendant to this scattering process has hampered trace detection. The realization that scattering is enhanced at a metallic surface has enabled new techniques for spectroscopic and imaging analysis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Interaction between jets during laser-induced forward transfer

Simultaneous two-beam laser-induced forward transfer (LIFT) was carried out for various inter-beam separations, analyzing both the resulting printing outcomes and the corresponding liquid transfer dynamics. In a first experiment, droplets of an aqueous solution were printed onto a substrate at different inter-beam distances, which proved that a significant departure from the single-beam LIFT dynamics takes places at specific separations. In the second experiment, time-resolved imaging analysis revealed the existence of significant jet-jet interactions at those separations; such interactions proceed through a dynamics that results in remarkable jet deflection for which a possible onset mechanism is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and optical characterization of NaGdF{sub 4}: Ho{sup 3+}/Yb{sup 3+} UC nano-particles for lateral finger mark detections

Ho{sup 3+}/Yb{sup 3+} co-doped NaGdF{sub 4} up-conversion (UC) nano-particles were synthesized by thermal decomposition method. X-ray diffraction and FE-SEM image analysis were done to confirm the structure, morphology and determination of particle size. The UC emission spectra for as prepared as well as 100°C, 200°C, 300°C, 400°C, 800°C, 1000°C and 1200°C heated for 3h samples were recorded and there emission intensities were compared at a constant pump power of excitations 98.1 W/cm{sup 2}. The effect of emission intensity on decay time was also studied through focused and unfocused excitations. The synthesized material was successfully utilized in lateral finger mark detections on the glass substrate through powder dusting method.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Velocity map imaging of OH radical products from IR activated (CH 3 ) 2 COO Criegee intermediates

The unimolecular dissociation dynamics of the dimethyl-substituted Criegee intermediate (CH 3 ) 2 COO is examined experimentally using velocity map imaging to ascertain the translational and internal energy distributions of the OH and H 2 CC(CH 3 )O radical products. The energy profile of key features along the reaction coordinate is also evaluated theoretically. Unimolecular decay of (CH 3 ) 2 COO is initiated by vibrational activation in the CH stretch overtone region and the resultant OH X 2 Π 3/2 (v = 0) products are state-selectively ionized and imaged. Analysis reveals an isotropic spatial distribution, indicative of a 3 ps lower limit for the timescale of dissociation, and a broad and unstructured total kinetic energy release distribution. The energy released to products is partitioned principally as internal excitation of the H 2 CC(CH 3 )O fragments with modest translational excitation of the fragments and a small degree of OH rotational excitation. The total kinetic energy release distribution observed for (CH 3 ) 2 COO is compared with that predicted for statistical partitioning over product quantum states, and contrasted with recent experimental and quasi-classical trajectory results for syn-CH 3 CHOO [N. M. Kidwell et al., Nat. Chem. 8, 509 (2016)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial luminescence imaging of dopant incorporation in CdTe Films

State-of-the-art cathodoluminescence (CL) spectrum imaging with spectrum-per-pixel CL emission mapping is applied to spatially profile how dopant elements are incorporated into Cadmium telluride (CdTe). Emission spectra and intensity monitor the spatial distribution of additional charge carriers through characteristic variations in the CL emission based on computational modeling. Our results show that grain boundaries play a role in incorporating dopants in CdTe exposed to copper, phosphorus, and intrinsic point defects in CdTe. Furthermore, the image analysis provides critical, unique feedback to understand dopant incorporation and activation in the inhomogeneous CdTe material, which has struggled to reach high levels of hole density.

14 SOLAR ENERGY↗

Luminescence methodology to determine grain-boundary, grain-interior, and surface recombination in thin-film solar cells

We determine the grain-boundary (GB) recombination velocity, S GB , and grain-interior (GI) lifetime, t GI , parameters in superstrate CdS/CdTe thin-film solar cell technology by combining cathodoluminescence (CL) spectrum imaging and time-resolved photoluminescence (TRPL) measurements. We consider critical device formation stages, including after CdTe deposition, CdCl 2 treatment, and Cu diffusion. CL image analysis methods extract GB and GI intensities and grain size for hundreds of grains per sample. Concurrently, a three-dimensional CL model is developed to simulate the GI intensity as a function of t GI , S GB , grain size, and the surface recombination velocity, S surf . TRPL measurements provide an estimate of S surf for the CL model. A fit of GI intensity vs. grain size data with the CL model gives a self-consistent and representative set of S GB and t GI values for the samples: S GB (t GI ) = 2.6 x 10 6 cm/s (68-250 ps), S GB (t GI ) = 4.1 x 10 5 cm/s (1.5-3.3 ns), and S GB (t GI ) = 5.5 x 10 5 cm/s (1.0-3.8 ns) for as-deposited, CdCl 2 -treated, and CdCl 2- A nd Cu-treated samples, respectively. Thus, we find that the CdCl2 treatment both helps to passivate GBs and significantly increase the GI lifetime. Subsequent Cu diffusion increases GB recombination slightly and has nuanced effects on the GI lifetime. Finally, as a partial check on the S GB and t GI values, they are input to a Sentaurus device model, and the simulated performance is compared to the measured performance. The methodology developed here can be applied broadly to CdTe and CdSeTe thin-film technology and to other thin-film solar cell materials including Cu(In 1-x Ga x )Se 2 , Cu 2 ZnSnS 4 , and perovskites.

14 SOLAR ENERGY↗

Multiple parameter dynamic photoresponse microscopy for data-intensive optoelectronic measurements of van der Waals heterostructures

Quantum devices made from van der Waals (vdW) heterostructures of two dimensional (2D) materials may herald a new frontier in designer materials that exhibit novel electronic properties and unusual electronic phases. However, due to the complexity of layered atomic structures and the physics that emerges, experimental realization of devices with tailored physical properties will require comprehensive measurements across a large domain of material and device parameters. Such multi-parameter measurements require new strategies that combine data-intensive techniques—often applied in astronomy and high energy physics—with the experimental tools of solid state physics and materials science. We discuss the challenges of comprehensive experimental science and present a technique, called Multi-Parameter Dynamic Photoresponse Microscopy (MPDPM), which utilizes ultrafast lasers, diffraction limited scanning beam optics, and hardware automation to characterize the photoresponse of 2D heterostructures in a time efficient manner. Using comprehensive methods on vdW heterostructures results in large and complicated data sets; in the case of MPDPM, we measure a large set of images requiring advanced image analysis to extract the underlying physics. We discuss how to approach such data sets in general and in the specific case of a graphene–boron nitride–graphite heterostructure photocell.

36 MATERIALS SCIENCE↗

Computer-automated tuning procedures for semiconductor quantum dot arrays

As with any quantum computing platform, semiconductor quantum dot devices require sophisticated hardware and controls for operation. The increasing complexity of quantum dot devices necessitates the advancement of automated control software and image recognition techniques for rapidly evaluating charge stability diagrams. We use an image analysis toolbox developed in Python to automate the calibration of virtual gates, a process that previously involved a large amount of user intervention. Moreover, we show that straightforward feedback protocols can be used to simultaneously tune multiple tunnel couplings in a triple quantum dot in a computer automated fashion. Finally, we adopt the use of a “tunnel coupling lever arm” to model the interdot barrier gate response and discuss how it can be used to more rapidly tune interdot tunnel couplings to the gigahertz values that are compatible with exchange gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A six degrees of freedom femtosecond laser system for fabrication of small-scale mechanical property specimens

Here, we present the details of a novel ultra-short pulsed laser machining workstation that has been employed for high-throughput laser machining of small-scale mechanical property specimens. This system employs a six degrees of freedom hexapod positioning stage capable of macroscopic movements at high positional accuracy. We developed a methodology that uses quantitative image analysis to measure key parameters required to minimize the hexapod positioning and rotational error. Application of this system to laser machining of small-scale 316L stainless steel tensile specimens and ultra-high molecular weight polyethylene compressive specimens using eucentric tilt and rotation about the specimen axis will be shown, where serial laser milling at a specimen tilt angle of 10° was used to effectively eliminate any taper in the sample cross section that is typically found in laser machining.

47 OTHER INSTRUMENTATION↗

Preparing for the Next Generation of EUV Lithography at the Center for X-ray Optics

The introduction of EUV lithography into high-volume semiconductor manufacturing this year represents a monumental milestone for EUV technology. After nearly 30 years of development, the EUV research community has overcome many of the key obstacles required to enable the long-awaited integration of EUV lithography into the lab. These obstacles have included: the development of a stable, high-powered EUV source to ensure adequate exposure tool reliability; controlling EUV mask defects and mask contamination; and the development of EUV resists with adequate sensitivity, resolution, and line width roughness to meet the tolerances required for high-volume manufacturing. As EUV moves into its second generation, there will be new challenges facing the community as it works to push EUV technology into the future. Smaller feature sizes will be achieved using higher numerical aperture optics, which are planned to have an anamorphic geometry (asymmetric magnification and numerical aperture between horizontal and vertical axes) to overcome 3D effects at the mask. This new geometry and its larger angle ranges make understanding mask absorber and multilayer effects all the more important. New methods for high-NA wavefront metrology need to be tested to ensure that these optical systems can be aligned to operate with minimal aberrations. Mask defects need to continue to be studied, and the inclusion of EUV pellicles in the roadmap requires that mask inspection and review systems adapt accordingly. Finally, new resists must be developed to support the increased resolution of feature sizes below 8 nm half pitch. The Center for X-ray Optics (CXRO) at Berkeley Lab has been a leader in EUV research for the past 25 years. Leveraging 13.5 nm EUV light from the Advanced Light Source synchrotron facility, CXRO is home to several EUV and soft X-ray (SXR) research tools that have provided important insights into EUV resists, masks, and coatings. The 0.3 NA Microfield exposure tool (MET) and Dose Calibration Tool (DCT) have played an instrumental role in the development of the current generation of high-resolution EUV resists. The Actinic Inspection Tool (AIT) and its successor, SHARP, have enabled aerial image analysis, providing key insights into mask defects, 3D mask effects, illumination, and aberrations. And the CXRO Reflectometer continues to be the industry standard in multilayer coating and EUV mask scattering metrology. To address the new challenges facing the next generation of EUV lithography, CXRO has upgraded its suite of EUV research tools. The 0.5 NA MET5 is a newly commissioned projection lithography tool that is capable of printing feature sizes down to 8 nm half pitch. A new radiation chemistry program is deploying several techniques aimed at dissecting the role of primary photoelectrons and secondary electrons in EUV resists. The SHARP microscope has been outfitted with anamorphic zone plate lenses that can emulate the geometry of next-generation EUV scanners, and the reflectometer has been applied to new scattering experiments for the purpose of understanding the 3D effects of EUV mask multilayers, as well as determining mask properties using scattering profiles. In parallel with these tools, the CXRO High-NA Wavefront Sensing Program is developing high-resolution wavefront sensors suitable for measuring aberrations at high NA. This article presents an overview of these programs and describes how they will address the primary challenges that face the EUV community as it moves to the next generation of EUV lithography.

47 OTHER INSTRUMENTATION↗

SEARCH FOR THE SUNYAEV-ZEL'DOVICH EFFECT IN A GIANT RADIO GALAXY B1358+305

We present results of an imaging observation of the central region of a giant radio galaxy B1358+305. The classical, standard scenario of Fanaroff-Riley II radio galaxies suggests that shock-produced hot electrons contained in a radio galaxy are a good reservoir of the jet-supplied energy from active nuclei. The aim of our observation is to search for the Sunyaev-Zel'dovich effect (SZE) induced by these hot electrons. The observation was performed at 21 GHz with the Nobeyama 45 m telescope. Deep imaging observation of a wide region of size 6.'7 x 6.'7 with the beam size {theta}{sub HPBW} = 81.''2 enables the most detailed examination of the possible thermal energy of electrons contained in a radio galaxy. The resultant intensity fluctuation is 0.56 mJy beam{sup -1} (in terms of the Compton y-parameter, y = 1.04 x 10{sup -4}) at a 95% confidence level. The intensity fluctuation obtained with imaging analysis sets the most stringent upper limit on the fluctuations in the central region of a giant radio galaxy obtained so far, and our results will be a toehold for future plans of SZE observation in a radio galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

HARD X-RAY FLUX UPPER LIMITS OF CENTRAL COMPACT OBJECTS IN SUPERNOVA REMNANTS

We searched for hard X-ray (20-300 keV) emission from nine central compact objects (CCOs) 1E 1207.4-5209, 1WGA J1713-3949, J082157.5-430017, J085201.4-461753, J160103.1-513353, J1613483-5055, J181852.0-150213, J185238.6+004020, and J232327.9+584843 with the International Gamma-Ray Astrophysics Laboratory observatory. We applied spectral imaging analysis and did not detect any of the sources with luminosity upper limits in the range of 10{sup 33}-10{sup 34} erg s{sup -1} in the 20-75 keV band. For nearby CCOs (less than 4 kpc), the upper-limit luminosities are an order of magnitude lower than the measured persistent hard X-ray luminosities of anomalous X-ray pulsars. This may indicate that the CCOs are low magnetic field systems with fallback disks around them.

79 ASTRONOMY AND ASTROPHYSICS↗

CHANDRA EVIDENCE FOR EXTENDED X-RAY STRUCTURE IN RY Tau

We report results of a sensitive Chandra ACIS-S observation of the classical T Tauri star RY Tau. Previous studies have shown that it drives a spectacular bipolar jet whose blueshifted component is traced optically along P.A. {approx} 295{sup 0} at separations of 1.''5-31'' from the star. Complex X-ray emission is revealed, including a very soft non-variable spectral component (some of which may originate in shocks), a superhot flaring component (T {approx}> 100 MK), and faint extended structure near the star. The structure is visible in deconvolved images and extends northwestward out to a separation of 1.''7, overlapping the inner part of the optical jet. Image analysis suggests that most of the extension is real, but some contamination by point-spread-function-induced structure within the central arcsecond may be present. The predicted temperature for a shock-heated jet based on jet speed and shock speed estimates from optical measurements is too low to explain the extended X-ray structure. Either higher speed material within the jet has escaped optical detection or other mechanisms besides shock heating are involved. Alternative mechanisms that could produce higher temperature plasma at small offsets to the northwest of RY Tau include magnetic heating in the jet, hot plasmoids ejected at high speeds, or X-ray emission from a putative close companion whose presence has been inferred from Hipparcos variations.

79 ASTRONOMY AND ASTROPHYSICS↗

PROBING THE IGM/GALAXY CONNECTION. IV. THE LCO/WFCCD GALAXY SURVEY OF 20 FIELDS SURROUNDING UV-BRIGHT QUASARS

We publish the survey for galaxies in 20 fields containing ultraviolet bright quasars (with z{sub em} {approx} 0.1-0.5) that can be used to study the association between galaxies and absorption systems from the low-z intergalactic medium (IGM). The survey is magnitude limited (R {approx} 19.5 mag) and highly complete out to 10' from the quasar in each field. It was designed to detect dwarf galaxies (L {approx} 0.1L*) at an impact parameter {rho} {approx} 1 Mpc (z = 0.1) from a quasar. The complete sample (all 20 fields) includes R-band photometry for 84,718 sources and confirmed redshifts for 2800 sources. This includes 1198 galaxies with 0.005 < z < (z{sub em} - 0.01) at a median redshift of 0.18, which may associated with IGM absorption lines. All of the imaging was acquired with cameras on the Swope 40'' telescope and the spectra were obtained via slit mask observations using the WFCCD spectrograph on the Dupont 100'' telescope at Las Campanas Observatory. This paper describes the data reduction, imaging analysis, photometry, and spectral analysis of the survey. We tabulate the principal measurements for all sources in each field and provide the spectroscopic data set online.

79 ASTRONOMY AND ASTROPHYSICS↗

Wavelet-based techniques for the gamma-ray sky

Here, we demonstrate how the image analysis technique of wavelet decomposition can be applied to the gamma-ray sky to separate emission on different angular scales. New structures on scales that differ from the scales of the conventional astrophysical foreground and background uncertainties can be robustly extracted, allowing a model-independent characterization with no presumption of exact signal morphology. As a test case, we generate mock gamma-ray data to demonstrate our ability to extract extended signals without assuming a fixed spatial template. For some point source luminosity functions, our technique also allows us to differentiate a diffuse signal in gamma-rays from dark matter annihilation and extended gamma-ray point source populations in a data-driven way.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗