Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy

Despite the capability of energy modulated electron therapy (EMET) to achieve highly conformal dose distributions in superficial targets it has not been widely implemented due to problems inherent in electron beam radiotherapy such as planning dosimetry accuracy, and verification as well as a lack of systems for automated delivery. In previous work we proposed a novel technique to deliver EMET using an automated 'few leaf electron collimator' (FLEC) that consists of four motor-driven leaves fit in a standard clinical electron beam applicator. Integrated with a Monte Carlo based optimization algorithm that utilizes patient-specific dose kernels, a treatment delivery was incorporated within the linear accelerator operation. The FLEC was envisioned to work as an accessory tool added to the clinical accelerator. In this article the design and construction of the FLEC prototype that match our compact design goals are presented. It is controlled using an in-house developed EMET controller. The structure of the software and the hardware characteristics of the EMET controller are demonstrated. Using a parallel plate ionization chamber, output measurements were obtained to validate the Monte Carlo calculations for a range of fields with different energies and sizes. Further verifications were also performed for comparing 1-D and 2-D dose distributions using energy independent radiochromic films. Comparisons between Monte Carlo calculations and measurements of complex intensity map deliveries show an overall agreement to within {+-}3%. This work confirms our design objectives of the FLEC that allow for automated delivery of EMET. Furthermore, the Monte Carlo dose calculation engine required for EMET planning was validated. The result supports the potential of the prototype FLEC for the planning and delivery of EMET.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-807: VMAT Vs. DIMRT Vs. SsIMRT Assessing the Dosimetric Parameters of Cervical Carcinoma Treatment with a 20-Patient Sample

Purpose: The purpose of this study is to assess the dosimetric parameters of cervical carcinoma treatment using 3 different radiation therapy delivery Methods: volumetric-modulated arc therapy (VMAT), the static-field dynamic multileaf collimator intensity-modulated radiation therapy (dIMRT) and the static-field step-and-shoot intensity-modulated radiotherapy (ssIMRT). Methods: Twenty patients with cervical carcinoma were selected to be planned with dual arc VMAT, dIMRT and ssIMRT using Monaco 3.3 TPS on the Axesse™ linear accelerator in this investigation. The total dose of the planning target volume (PTV) is 60Gy. The homogeneity index (HI), conformity index (CI), dose volume histograms (DVHs), delivery efficiency, dose of organs at risks (bladder, rectum, and femoral heads), were all measured. Results: Dose distribution in 3 different radiation therapy delivery methods satisfied clinical requirements. Mean HI of PTV with VMAT, dIMRT and ssIMRT is 1.08, 1.10, and 1.09 (p>0.05). Mean CI of PTV with VMAT, dIMRT and ssIMRT is 0.82, 0.8 and 0.8 (p>0.05). For the DVH of V10, V20 and V30 in bladder, there was a significant difference: VMAT>dIMRT=ssIMRT (p <0.05). For the DVH of V40 and V50, there was a significant difference: VMAT dIMRT >ssIMRT (p <0.05). Conclusion: The results show that VMAT has a great advantage in delivery efficiency than dIMRT and ssIMRT, without compromise to the PTV coverage, HI and CI. The delivery methods should be considered under the actual cervical carcinoma radiotherapy situation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Investigation of conformal and intensity-modulated radiation therapy techniques to determine the absorbed fetal dose in pregnant patients with breast cancer

The aim of this research was to investigate the fetal doses of pregnant patients undergoing conformal radiotherapy or intensity-modulated radiation therapy (IMRT) for breast cancers. An Alderson Rando phantom was chosen to simulate a pregnant patient with breast cancer who is receiving radiation therapy. This phantom was irradiated using the Varian Clinac DBX 600 system (Varian Medical System, Palo Alto, CA) linear accelerator, according to the standard treatment plans of both three-dimensional conformal radiation therapy (3-D CRT) and IMRT techniques. Thermoluminescent dosimeters were used to measure the irradiated phantom's virtually designated uterus area. Thermoluminescent dosimeter measurements (in the phantom) revealed that the mean cumulative fetal dose for 3-D CRT is 1.39 cGy and for IMRT it is 8.48 cGy, for a pregnant breast cancer woman who received radiation treatment of 50 Gy. The fetal dose was confirmed to increase by 70% for 3-D CRT and 40% for IMRT, if it is closer to the irradiated field by 5 cm. The mean fetal dose from 3-D CRT is 1.39 cGy and IMRT is 8.48 cGy, consistent with theoretic calculations. The IMRT technique causes the fetal dose to be 5 times more than that of 3-D CRT. Theoretic knowledge concerning the increase in the peripheral doses as the measurements approached the beam was also practically proven.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-A-19A-01: SRT I: Comparison of SRT Techniques

Within the past several years, the field of radiosurgery has seen numerous technological enhancements, including new dedicated devices for stereotactic delivery, the use of re-locatable frames to facilitate fractionated delivery and the image guided frameless approaches. The goal of this symposium is to compare and contrast competing technologies for cranial SRS/SRT. The symposium will open with a review of the general concept of cranial SRS/SRT procedures as well as describe the key differences from conventional radiotherapy. The speakers will then review each of the delivery technique (Gamma Knife, CyberKnife and Conventional linear accelerator) in turn. The focus of each speaker will be to describe the general workflow of each SRS modality, indications and counterindications for treatment. To compare and contrast different technologies, 2–3 cases examples demonstrating interesting treatment situations and expected outcomes, a sample treatment plan (either live or pre-recorded with live commentary) demonstrating the treatment planning technique, and machine and patient-specific QA required for treatment (if applicable). Additionally, workflows and data describing the use of immobilization devices or tracking/monitoring during SRS/SRT delivery will also be discussed. The session will close with a roundtable discussion of methods to evaluate plan quality, and achievable technical and clinical goals for intracranial SRS. Learning Objectives: Understand the key differences between cranial SRS/SRT and conventional treatments. Review Gamma Knife, CyberKnife and Conventional Linac-based radiosurgery delivery techniques and quality assurance Compare and contrast treatment plans, treatment planning strategy and and quality assurance procedures for each technology. Be able to establish cranial SRS/SRT procedure with optimized quality assurance program for each technology.

60 APPLIED LIFE SCIENCES↗

SU-E-T-754: Three-Dimensional Patient Modeling Using Photogrammetry for Collision Avoidance

Purpose: To evaluate photogrammetry for creating a three-dimensional patient model. Methods: A mannequin was configured on the couch of a CT scanner to simulate a patient setup using an indexed positioning device. A CT fiducial was placed on the indexed CT table-overlay at the reference index position. Two dimensional photogrammetry targets were placed on the table in known positions. A digital SLR camera was used to obtain 27 images from different positions around the CT table. The images were imported into a commercial photogrammetry package and a 3D model constructed. Each photogrammetry target was identified on 2 to 5 images. The CT DICOM metadata and the position of the CT fiducial were used to calculate the coordinates of the photogrammetry targets in the CT image frame of reference. The coordinates were transferred to the photogrammetry software to orient the 3D model. The mannequin setup was transferred to the treatment couch of a linear accelerator and positioned at isocenter using in-room lasers. The treatment couch coordinates were noted and compared with prediction. The collision free regions were measured over the full range of gantry and table motion and were compared with predictions obtained using a general purpose polygon interference algorithm. Results: The reconstructed 3D model consisted of 180000 triangles. The difference between the predicted and measured couch positions were 5 mm, 1 mm, and 1 mm for longitudinal, lateral, and vertical, respectively. The collision prediction tested 64620 gantry table combinations in 11.1 seconds. The accuracy was 96.5%, with false positive and negative results occurring at the boundaries of the collision space. Conclusion: Photogrammetry can be used as a tool for collision avoidance during treatment planning. The results indicate that a buffer zone is necessary to avoid false negatives at the boundary of the collision-free zone. Testing with human patients is underway. Research partially supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets

Twenty-three targets in 16 patients treated with stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT) were analyzed in terms of dosimetric homogeneity, target conformity, organ-at-risk (OAR) sparing, monitor unit (MU) usage, and beam-on time per fraction using RapidArc volumetric-modulated arc therapy (VMAT) vs. multifield sliding-window intensity-modulated radiation therapy (IMRT). Patients underwent computed tomography simulation with site-specific immobilization. Magnetic resonance imaging fusion and optical tracking were incorporated as clinically indicated. Treatment planning was performed using Eclipse v8.6 to generate sliding-window IMRT and 1-arc and 2-arc RapidArc plans. Dosimetric parameters used for target analysis were RTOG conformity index (CI{sub RTOG}), homogeneity index (HI{sub RTOG}), inverse Paddick Conformity Index (PCI), D{sub mean} and D5-D95. OAR sparing was analyzed in terms of D{sub max} and D{sub mean}. Treatment delivery was evaluated based on measured beam-on times delivered on a Varian Trilogy linear accelerator and recorded MU values. Dosimetric conformity, homogeneity, and OAR sparing were comparable between IMRT, 1-arc RapidArc and 2-arc RapidArc plans. Mean beam-on times {+-} SD for IMRT and 1-arc and 2-arc treatments were 10.5 {+-} 7.3, 2.6 {+-} 1.6, and 3.0 {+-} 1.1 minutes, respectively. Mean MUs were 3041, 1774, and 1676 for IMRT, 1-, and 2-arc plans, respectively. Although dosimetric conformity, homogeneity, and OAR sparing were similar between these techniques, SRS and SBRT fractions treated with RapidArc were delivered with substantially less beam-on time and fewer MUs than IMRT. The rapid delivery of SRS and SBRT with RapidArc improved workflow on the linac with these otherwise time-consuming treatments and limited the potential for intrafraction organ and patient motion, which can cause significant dosimetric errors. These clinically important advantages make image-guided RapidArc useful in the delivery of SRS and SBRT to intracranial and extracranial targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

Agreement Between Institutional Measurements and Treatment Planning System Calculations for Basic Dosimetric Parameters as Measured by the Imaging and Radiation Oncology Core-Houston

Purpose: To compare radiation machine measurement data collected by the Imaging and Radiation Oncology Core at Houston (IROC-H) with institutional treatment planning system (TPS) values, to identify parameters with large differences in agreement; the findings will help institutions focus their efforts to improve the accuracy of their TPS models. Methods and Materials: Between 2000 and 2014, IROC-H visited more than 250 institutions and conducted independent measurements of machine dosimetric data points, including percentage depth dose, output factors, off-axis factors, multileaf collimator small fields, and wedge data. We compared these data with the institutional TPS values for the same points by energy, class, and parameter to identify differences and similarities using criteria involving both the medians and standard deviations for Varian linear accelerators. Distributions of differences between machine measurements and institutional TPS values were generated for basic dosimetric parameters. Results: On average, intensity modulated radiation therapy–style and stereotactic body radiation therapy–style output factors and upper physical wedge output factors were the most problematic. Percentage depth dose, jaw output factors, and enhanced dynamic wedge output factors agreed best between the IROC-H measurements and the TPS values. Although small differences were shown between 2 common TPS systems, neither was superior to the other. Parameter agreement was constant over time from 2000 to 2014. Conclusions: Differences in basic dosimetric parameters between machine measurements and TPS values vary widely depending on the parameter, although agreement does not seem to vary by TPS and has not changed over time. Intensity modulated radiation therapy–style output factors, stereotactic body radiation therapy–style output factors, and upper physical wedge output factors had the largest disagreement and should be carefully modeled to ensure accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and evaluation of an efficient approach to volumetric arc therapy planning

An efficient method for volumetric intensity modulated arc therapy (VMAT) planning was developed, where a single arc (360 deg. or less) is delivered under continuous variation of multileaf collimator (MLC) segments, dose rate, and gantry speed. Plans can be generated for any current linear accelerator that supports these degrees of freedom. MLC segments are derived from fluence maps at relatively coarsely sampled angular positions. The beam segments, dose rate, and gantry speed are then optimized using direct machine parameter optimization based on dose volume objectives and leaf motion constraints to minimize arc delivery time. The method can vary both dose rate and gantry speed or alternatively determine the optimal plan at constant dose rate and gantry speed. The method was used to retrospectively generate variable dose rate VMAT plans to ten patients (head and neck, prostate, brain, lung, and tonsil). In comparison to step-and-shoot intensity modulated radiation therapy, dosimetric plan quality was comparable or improved, estimated delivery times ranged from 70 to 160 s, and monitor units were consistently reduced in nine out of the ten cases by an average of {approx}6%. Optimization and final dose calculation took between 5 and 35 min depending on plan complexity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated Magnetic Resonance Imaging in the Radiotherapy Clinic

Purpose: To introduce a novel technology arrangement in an integrated environment and outline the logistics model needed to incorporate dedicated magnetic resonance (MR) imaging in the radiotherapy workflow. An initial attempt was made to analyze the value and feasibility of MR-only imaging compared to computed tomography (CT) imaging, testing the assumption that MR is a better choice for target and healthy tissue delineation in radiotherapy. Methods and Materials: A 1.5-T MR unit with a 70-cm-bore size was installed close to a linear accelerator, and a special trolley was developed for transporting patients who were fixated in advance between the MR unit and the accelerator. New MR-based workflow procedures were developed and evaluated. Results: MR-only treatment planning has been facilitated, thus avoiding all registration errors between CT and MR scans, but several new aspects of MR imaging must be considered. Electron density information must be obtained by other methods. Generation of digitally reconstructed radiographs (DRR) for x-ray setup verification is not straight forward, and reliable corrections of geometrical distortions must be applied. The feasibility of MR imaging virtual simulation has been demonstrated, but a key challenge to overcome is correct determination of the skeleton, which is often needed for the traditional approach of beam modeling. The trolley solution allows for a highly precise setup for soft tissue tumors without the invasive handling of radiopaque markers. Conclusions: The new logistics model with an integrated MR unit is efficient and will allow for improved tumor definition and geometrical precision without a significant loss of dosimetric accuracy. The most significant development needed is improved bone imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery

Purpose: To provide real-time lung tumor motion estimation during radiotherapy treatment delivery without the need for implanted fiducial markers or additional imaging dose to the patient.Methods: 2D radiographs from the therapy beam's-eye-view (BEV) perspective are captured at a frame rate of 12.8 Hz with a frame grabber allowing direct RAM access to the image buffer. An in-house developed real-time soft tissue localization algorithm is utilized to calculate soft tissue displacement from these images in real-time. The system is tested with a Varian TX linear accelerator and an AS-1000 amorphous silicon electronic portal imaging device operating at a resolution of 512 × 384 pixels. The accuracy of the motion estimation is verified with a dynamic motion phantom. Clinical accuracy was tested on lung SBRT images acquired at 2 fps.Results: Real-time lung tumor motion estimation from BEV images without fiducial markers is successfully demonstrated. For the phantom study, a mean tracking error <1.0 mm [root mean square (rms) error of 0.3 mm] was observed. The tracking rms accuracy on BEV images from a lung SBRT patient (≈20 mm tumor motion range) is 1.0 mm.Conclusions: The authors demonstrate for the first time real-time markerless lung tumor motion estimation from BEV images alone. The described system can operate at a frame rate of 12.8 Hz and does not require prior knowledge to establish traceable landmarks for tracking on the fly. The authors show that the geometric accuracy is similar to (or better than) previously published markerless algorithms not operating in real-time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of ( n, γ ) cross section of 90 Zr [Abstract]

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σγ/σt ratio at most neutron energies, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σγ, of Zr isotopes. The ENDF/B-VIII.0 library has a relative uncertainty of approximately 10-20% for incident neutron energies < 0.1 MeV, and uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program (NCSP) to embark on a campaign to accurately measure and evaluate these isotopes of Zr. Here we will show energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr. The measurements of isotopically enriched samples are being carried out at the Geel Electron Linear Accelerator (GELINA) facility of the Joint Research Center - Geel (JRC-Geel) of the European Union. As isotopic enrichment is a costly process we are careful not to activate any of the samples, as this may hinder future radiation-sensitive measurements. The activation analysis is presented in a report by Brown et al.. Once we were satisfied that the Zr samples would not be activated by the measurements, the 90 Zr sample was fabricated at Oak Ridge National Laboratory (ORNL) and shipped to GELINA. The dimensions of the cylindrical sample are approximately 0.12 cm thick and a radius of 2.5 cm. Since 90 Zr is not chemically reactive to air, bare metallic samples were employed. The sample was measured at a flight path (FP) length of 60 m, using four C 6 D 6 detectors on FP14. The final paper will include experimental details and measured cross section data for 90 Zr compared to current evaluated nuclear data libraries.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the branching fraction, polarization, and CP asymmetries in B{sup 0}{yields}{rho}{sup 0}{rho}{sup 0} decay, and implications for the CKM angle {alpha}

We study B{sup 0}{yields}{rho}{sup 0}{rho}{sup 0} decays in a sample of 465x10{sup 6} {upsilon}(4S){yields}BB events collected with the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider located at the Stanford Linear Accelerator Center (SLAC). We measure the branching fraction B=(0.92{+-}0.32{+-}0.14)x10{sup -6} and longitudinal polarization fraction f{sub L}=0.75{sub -0.14}{sup +0.11}{+-}0.05, where the first uncertainty is statistical and the second is systematic. The evidence for the B{sup 0}{yields}{rho}{sup 0}{rho}{sup 0} signal has a significance of 3.1 standard deviations, including systematic uncertainties. We investigate the proper-time dependence of the longitudinal component in the decay and measure the CP-violating coefficients S{sub L}{sup 00}=(0.3{+-}0.7{+-}0.2) and C{sub L}{sup 00}=(0.2{+-}0.8{+-}0.3). We study the implication of these results for the unitarity triangle angle {alpha}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-199: Comparison Between Acuros XB and AAA in Homogeneous Phantoms for Volumetric Modulated Arc Therapy Plans

Purpose: To investigate the differences among Acuros XB (AXB) with dose-to-water report mode (AXBw), AXB with dose-to-medium report mode (AXBm) and Anisotropic Analytical Algorithm (AAA), in homogeneous phantoms and for volumetric modulated arc therapy (VMAT) plans. Methods: Nineteen clinically applied VMAT plans were transplanted to a Delta4 phantom and an I’mRT phantom to generate phantom plans, respectively. Each plan was calculated using AXBw, AXBm and AAA, respectively, utilizing the distributed calculation framework (DCF), and the calculation times were recorded. Each plan was delivered by the TrueBeam linear accelerator and measured using the Delta4 phantom and ionization chamber, respectively. The 3D gamma pass rates and point dose deviations were compared among AXBw, AXBm and AAA. Results: In terms of the gamma pass rates with both the criteria of 3 mm/3% (3 mm distance-to-agreement, 3% dose difference) and 2 mm/2%, AXBm demonstrated the significantly worst results, and no significant difference was found between AXBw and AAA. In terms of the point dose, AXBw was slightly closer to the measured dose compared with AAA, and AXBm demonstrated the maximum dose deviation from the measured dose. Moreover, AXB calculation consumed comparable time when the DCF was not busy, and consumed significantly less time when the DCF was busy. Conclusion: In the homogeneous phantoms and for the VMAT plans, AXBw has the best dose accuracy, and AAA is comparable to or slightly worse than AXBw, wheras AXBm has the worst dose accuracy. Furthermore, AXB has higher calculation efficiency than AAA.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.

60 APPLIED LIFE SCIENCES↗

Optima XE Single Wafer High Energy Ion Implanter

The Optima XE is the first production worthy single wafer high energy implanter. The new system combines a state-of-art single wafer endstation capable of throughputs in excess of 400 wafers/hour with a production-proven RF linear accelerator technology. Axcelis has been evolving and refining RF Linac technology since the introduction of the NV1000 in 1986. The Optima XE provides production worthy beam currents up to energies of 1.2 MeV for P{sup +}, 2.9 MeV for P{sup ++}, and 1.5 MeV for B{sup +}. Energies as low as 10 keV and tilt angles as high as 45 degrees are also available., allowing the implanter to be used for a wide variety of traditional medium current implants to ensure high equipment utilization. The single wafer endstation provides precise implant angle control across wafer and wafer to wafer. In addition, Optima XE's unique dose control system allows compensation of photoresist outgassing effects without relying on traditional pressure-based methods. We describe the specific features, angle control and dosimetry of the Optima XE and their applications in addressing the ever-tightening demands for more precise process controls and higher productivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of B{sup +}{yields}{eta}{rho}{sup +} and search for B{sup 0} decays to {eta}'{eta}, {eta}{pi}{sup 0}, {eta}'{pi}{sup 0}, and {omega}{pi}{sup 0}

We present measurements of branching fractions for five B-meson decays to two-body charmless final states. The data, collected with the BABAR detector at the Stanford Linear Accelerator Center, represent 459x10{sup 6} BB pairs. The results for branching fractions are, in units of 10{sup -6} (upper limits at 90% C.L.), B(B{sup +}{yields}{eta}{rho}{sup +})=9.9{+-}1.2{+-}0.8, B(B{sup 0}{yields}{eta}{sup '}{eta})=0.5{+-}0.4{+-}0.1(<1.2), B(B{sup 0}{yields}{eta}{pi}{sup 0})=0.9{+-}0.4{+-}0.1(<1.5), B(B{sup 0}{yields}{eta}{sup '}{pi}{sup 0})=0.9{+-}0.4{+-}0.1(<1.5), and B(B{sup 0}{yields}{omega}{pi}{sup 0})=0.07{+-}0.26{+-}0.02(<0.5). The first error quoted is statistical and the second systematic. For the {eta}{rho}{sup +} mode, we measure the charge asymmetry A{sub ch}(B{sup +}{yields}{eta}{rho}{sup +})=0.13{+-}0.11{+-}0.02.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tumor trailing strategy for intensity-modulated radiation therapy of moving targets

Internal organ motion during the course of radiation therapy of cancer affects the distribution of the delivered dose and, generally, reduces its conformality to the targeted volume. Previously proposed approaches aimed at mitigating the effect of internal motion in intensity-modulated radiation therapy (IMRT) included expansion of the target margins, motion-correlated delivery (e.g., respiratory gating, tumor tracking), and adaptive treatment plan optimization employing a probabilistic description of motion. We describe and test the tumor trailing strategy, which utilizes the synergy of motion-adaptive treatment planning and delivery methods. We regard the (rigid) target motion as a superposition of a relatively fast cyclic component (e.g., respiratory) and slow aperiodic trends (e.g., the drift of exhalation baseline). In the trailing approach, these two components of motion are decoupled and dealt with separately. Real-time motion monitoring is employed to identify the 'slow' shifts, which are then corrected by applying setup adjustments. The delivery does not track the target position exactly, but trails the systematic trend due to the delay between the time a shift occurs, is reliably detected, and, subsequently, corrected. The ''fast'' cyclic motion is accounted for with a robust motion-adaptive treatment planning, which allows for variability in motion parameters (e.g., mean and extrema of the tidal volume, variable period of respiration, and expiratory duration). Motion-surrogate data from gated IMRT treatments were used to provide probability distribution data for motion-adaptive planning and to test algorithms that identified systematic trends in the character of motion. Sample IMRT fields were delivered on a clinical linear accelerator to a programmable moving phantom. Dose measurements were performed with a commercial two-dimensional ion-chamber array. The results indicate that by reducing intrafractional motion variability, the trailing strategy enhances relevance and applicability of motion-adaptive planning methods, and improves conformality of the delivered dose to the target in the presence of irregular motion. Trailing strategy can be applied to respiratory-gated treatments, in which the correction for the slow motion can increase the duty cycle, while robust probabilistic planning can improve management of the residual motion within the gate window. Similarly, trailing may improve the dose conformality in treatment of patients who exhibit detectable target motion of low amplitude, which is considered insufficient to provide a clinical indication for the use of respiratory-gated treatment (e.g., peak-to-peak motion of less than 10 mm). The mechanical limitations of implementing tumor trailing are less rigorous than those of real-time tracking, and the same technology could be used for both.

62 RADIOLOGY AND NUCLEAR MEDICINE↗