Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Insulating state to quantum Hall-like state transition in a spin-orbit-coupled two-dimensional electron system

We study interference and interactions in an InAs/InAsSb two-dimensional electron system. In such a system, spin-orbit interactions are shown to be strong, which result in weak antilocalization (WAL) and thereby positive magnetoresistance around zero magnetic field. After suppressing WAL by the magnetic field, we demonstrate that classical positive magnetoresistance due to spin-orbit coupling plays a role. With further increasing the magnetic field, the system undergoes a direct insulator-quantum Hall transition. By analyzing the magnetotransport behavior in different field regions, we show that both electron-electron interactions and spin-related effects are essential in understanding the observed direct transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Discontinuous finite element space-angle treatment of the first order linear Boltzmann transport equation with magnetic fields: Application to MRI-guided radiotherapy

Purpose: The advent of magnetic resonance imaging (MRI) guided radiotherapy systems demands the incorporation of the magnetic field into dose calculation algorithms of treatment planning systems. This is due to the fact that the Lorentz force of the magnetic field perturbs the path of the relativistic electrons, hence altering the dose deposited by them. Building on the previous work, the authors have developed a discontinuous finite element space-angle treatment of the linear Boltzmann transport equation to accurately account for the effects of magnetic fields on radiotherapy doses. Methods: The authors present a detailed description of their new formalism and compare its accuracy to GEANT4 Monte Carlo calculations for magnetic fields parallel and perpendicular to the radiation beam at field strengths of 0.5 and 3 T for an inhomogeneous 3D slab geometry phantom comprising water, bone, and air or lung. The accuracy of the authors’ new formalism was determined using a gamma analysis with a 2%/2 mm criterion. Results: Greater than 98.9% of all points analyzed passed the 2%/2 mm gamma criterion for the field strengths and orientations tested. The authors have benchmarked their new formalism against Monte Carlo in a challenging radiation transport problem with a high density material (bone) directly adjacent to a very low density material (dry air at STP) where the effects of the magnetic field dominate collisions. Conclusions: A discontinuous finite element space-angle approach has been proven to be an accurate method for solving the linear Boltzmann transport equation with magnetic fields for cases relevant to MRI guided radiotherapy. The authors have validated the accuracy of this novel technique against GEANT4, even in cases of strong magnetic field strengths and low density air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancement of magnetodielectric coupling in 6H-perovskites Ba 3 R Ru 2 O 9 for heavier rare-earth cations ( R = Ho , Tb )

The role of rare-earth ( R ) ions in magnetodielectric (MD) coupling is always intriguing and markedly different for different systems. Although many reports are available concerning this aspect in frustrated 3 d -transition metal oxides, no such reports exist on higher d ( 4 d /5 d )-orbital based systems due to the rare availability of highly insulating 4 d /5 d systems. Here, we systematically investigated the magnetic, dielectric, ferroelectric, and magnetodielectric behavior of the 6H-perovskites Ba 3 R Ru 2 O 9 for different R -ions, namely R = Sm , Tb , and Ho, which magnetically order at 12, 9.5, and 10.2 K, respectively. For R = Tb and Ho, the temperature and magnetic-field-dependent complex dielectric constant traces the magnetic features, which manifests MD coupling in this system. A weak magnetic-field ( H ) induced transition is observed for ~ 30 kOe , which is clearly captured in H -dependent dielectric measurements. No MD coupling is observed for Ba 3 SmRu 2 O 9 . The MD coupling is enhanced by a factor of 3 and 20 times for R = Tb and Ho, respectively, when compared to that of the Nd-counterpart. Here, these results evidence the gradual enhancement of MD coupling with the introduction of heavier R -ions in this series, which is attributed to their larger moment values. Our investigation establishes dominating 4 d (Ru)-4ƒ( R ) magnetic correlation in this series for the heavier R -members.

36 MATERIALS SCIENCE↗

PERIOD CHANGES AND FOUR-COLOR LIGHT CURVES OF THE ACTIVE OVERCONTACT BINARY V396 MONOCEROTIS

This paper analyzes the first obtained four-color light curves of V396 Mon using the 2003 version of the W-D code. It is confirmed that V396 Mon is a shallow W-type contact binary system with a mass ratio q = 2.554({+-}0.004) and a degree of contact factor f = 18.9%({+-}1.2%). A period investigation based on all available data shows that the period of the system includes a long-term decrease (dP/dt = -8.57 x 10{sup -8} days yr{sup -1}) and an oscillation (A{sub 3} = 0.0160 day, T{sub 3} = 42.4 yr). They are caused by angular momentum loss and light-time effect, respectively. The suspect third body is possibly a small M-type star (about 0.31 solar mass). Though some observations indicate that this system has strong magnetic activity, by our analysis we found that the Applegate mechanism cannot explain the periodic changes. This binary is an especially important system according to Qian's statistics of contact binaries as its mass ratio lies near the proposed pivot point about which the physical structure of contact binaries supposedly oscillates.

79 ASTRONOMY AND ASTROPHYSICS↗

Kernel polynomial method for linear spin wave theory

Calculating dynamical spin correlations is essential for matching model magnetic exchange Hamiltonians to momentum-resolved spectroscopic measurements. A major numerical bottleneck is the diagonalization of the dynamical matrix, especially in systems with large magnetic unit cells, such as those with incommensurate magnetic structures or quenched disorder. In this paper, we demonstrate an efficient scheme based on the kernel polynomial method for calculating dynamical correlations of relevance to inelastic neutron scattering experiments. This method reduces the scaling of numerical cost from cubic to linear in the magnetic unit cell size.

97 MATHEMATICS AND COMPUTING↗

Plasma Surface Interactions: Predicting the Performance and Impact of Dynamic PFC Surfaces

This project focused on the development and integration of high-performance simulation tools to predict the operating behavior of Plasma-Facing Components in magnetic confinement fusion systems. A key objective at Illinois was to assess the impact of the dynamic interplay between the evolving material surface and the magnetized plasma sheath, and characterize the impact of tungsten-based PFCs on plasma contamination, including phenomena such as surface erosion, dynamic recycling of fuel species, and tritium retention, which are critical for the success of future magnetic fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional spin liquid behaviour in the triangular-honeycomb antiferromagnet TbInO 3

Spin liquid ground states are predicted to arise within several distinct scenarios in condensed matter physics. The observation of these disordered magnetic states is particularly pervasive among a class of materials known as frustrated magnets, in which the competition between various magnetic exchange interactions prevents the system from adopting long-range magnetic order at low temperatures. Spin liquids continue to be of great interest due to their exotic nature and the possibility that they may support fractionalized excitations, such as Majorana fermions. Systems that allow for such phenomena are not only fascinating from a fundamental perspective but may also be practically significant in future technologies based on quantum computation. Here we show that the underlying antiferromagnetic sublattice in TbInO 3 can undergo a crystal field-induced distortion of its buckled triangular arrangement to one based on a honeycomb. The absence of a conventional magnetic ordering transition at the lowest measurable temperatures indicates that another critical mechanism must govern in the ground-state selection of TbInO 3 . Here, we suggest that anisotropic exchange interactions—mediated through strong spin–orbit coupling on the emergent honeycomb lattice of TbInO 3 —give rise to a highly frustrated spin liquid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Substantially parallel flux uncluttered rotor machines

A permanent magnet-less and brushless synchronous system includes a stator that generates a magnetic rotating field when sourced by polyphase alternating currents. An uncluttered rotor is positioned within the magnetic rotating field and is spaced apart from the stator. An excitation core is spaced apart from the stator and the uncluttered rotor and magnetically couples the uncluttered rotor. The brushless excitation source generates a magnet torque by inducing magnetic poles near an outer peripheral surface of the uncluttered rotor, and the stator currents also generate a reluctance torque by a reaction of the difference between the direct and quadrature magnetic paths of the uncluttered rotor. The system can be used either as a motor or a generator

42 ENGINEERING↗

Magnetic leverage effects in amorphous SmCo/CoAlZr heterostructures

Although magnetic heterostructures are the basis of many magnetic technologies, the mechanisms involved in magnetization reversals in such structures are not fully understood, especially in amorphous multilayers. Here, we report on the SmCo/CoAlZr system and exploit resonant magnetic x-ray scattering to probe the element specific magnetization reversals. When combined into a tri-layer structure, two different switching fields and reversal mechanisms are observed for the Sm and Co sub-lattices. We argue that the decoupling of the sub-lattices arises from the local distribution of atomic species within the amorphous matrix leading to a strong magnetic leverage effect and exchange pinning. The decoupling arises due to strong interactions between regions of high Co density which span the interface. The relatively sparse interactions between Sm and Co induce a localized pinning of the Co-rich areas, resulting in an exchange bias in minor loops and an enhanced coercivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical characterization of experimental magnetized liner inertial fusion stagnation images using deep-learning-based fuel–background segmentation

Significant variety is observed in spherical crystal x-ray imager (SCXI) data for the stagnated fuel–liner system created in Magnetized Liner Inertial Fusion (MagLIF) experiments conducted at the Sandia National Laboratories Z-facility. As a result, image analysis tasks involving, e.g., region-of-interest selection (i.e. segmentation), background subtraction and image registration have generally required tedious manual treatment leading to increased risk of irreproducibility, lack of uncertainty quantification and smaller-scale studies using only a fraction of available data. We present a convolutional neural network (CNN)-based pipeline to automate much of the image processing workflow. This tool enabled batch preprocessing of an ensemble of N scans = 139 SCXI images across N exp = 67 different experiments for subsequent study. The pipeline begins by segmenting images into the stagnated fuel and background using a CNN trained on synthetic images generated from a geometric model of a physical three-dimensional plasma. The resulting segmentation allows for a rules-based registration. Our approach flexibly handles rarely occurring artifacts through minimal user input and avoids the need for extensive hand labelling and augmentation of our experimental dataset that would be needed to train an end-to-end pipeline. Here we also fit background pixels using low-degree polynomials, and perform a statistical assessment of the background and noise properties over the entire image database. Our results provide a guide for choices made in statistical inference models using stagnation image data and can be applied in the generation of synthetic datasets with realistic choices of noise statistics and background models used for machine learning tasks in MagLIF data analysis. We anticipate that the method may be readily extended to automate other MagLIF stagnation imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

JLAB's Super High Momentum Spectrometer's Superconducting Q1 Magnet

Abstract- The commissioning and test results of a super ferric, superconducting, quadrupole magnet, constructed by Scientific Magnetics Inc. for Thomas Jefferson National Accelerator Facility (TJNAF also known as JLAB) will be presented. The quadrupole magnet, named Q1, is the first focusing element in the Super High Momentum Spectrometer (SHMS). The SHMS, located within JLAB's experimental Hall C, consists of all superconducting magnets in a dQQQD configuration and is part of the JLAB's 12 Gev upgrade. Here "d" refers to the small horizontal bend dipole, "Q" stands for focusing quadrupole magnets and "D" is the vertical bending, momentum-selecting dipole magnet. Characterization of the magnet's cryogenic heat loads and magnetic field quality will be presented along with descriptions of the magnet's control system, power supply, and quench detection system.

Superconductor Magnets, Detector Magnets, Cold Iro↗

Oscillatory interlayer coupling in spin Hall systems

Many spintronics applications consist of ultrathin magnetic and nonmagnetic multilayers and require an in-depth understanding of interfacial magnetism and spin transport. Here, we study permalloy/copper/platinum multilayer systems. We find that magnetic damping, perpendicular anisotropy, and proximity magnetization exhibit correlated oscillations as a function of the copper thickness. We ascribe these observations to an oscillatory interlayer coupling between permalloy and platinum. Such interlayer coupling may have a significant impact on the performance of spintronics applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MAGNET Scaling and Methodology

The purpose of this study was to analyze the heat transfer of the Microreactor Agile Non-nuclear Experimental Testbed (MAGNET) within the Dynamic Energy Transport and Integration Laboratory (DETAIL) and develop scaling equations and models to couple with other systems. Hierarchical Two-Tiered Scaling (H2TS) methodologies were applied to DETAIL’s MAGNET facility to scale and project data sets while conserving the observed behavior based on first principles. The MAGNET system was successfully scaled using H2TS and multiple system parameters were determined or calculated from experimental data including steady state and transient data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BXS Re-calibration

Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel indicated that the vacuum chamber was in fact in the proper position with respect to the magnet - not 19 mm off to one side - so the former possibility was discounted. Review of the Fiducial Report and an interview with Keith Caban convinced me that there was no error in the coordinate system used for magnet measurements. I went and interviewed Andrew Fischer who did the magnetic measurements of BXS. He had extensive records, including photographs of the setups and could quickly answer quite detailed questions about how the measurement was done. Before the interview, I had a suspicion there might have been a sign flip in the x coordinate which because of the wedge would result in the wrong path length and a miscalibration. Andrew was able to pin-point how this could have happened and later confirmed it by looking an measurement data from the BXG magnet done just after BXS and comparing photographs. It turned out that the sign of the horizontal stage travel that drives the measurement wire was opposite that of the x coordinate in the Traveler, and the sign difference wasn't applied to the data. The origin x = 0 was set up correctly, but the wire moved in the opposite direction to what was expected, just as if the arc had been flipped over about the origin. To quantitatively confirm that this was the cause of the observed difference in calibration I used the 'grid data', which was taken with a Hall probe on the BXS magnet originally to measure the FINT (focusing effect) term, and combined it with the Hall probe data taken on the flipped trajectory, and performed the field integral on a path that should give the same result as the design path. This is best illustrated in Figure 2. The integration path is coincident with the desired path from the pivot points (x = 0) outward. Between the pivot points the integration path is a mirror image of the design path, but because the magnet is fairly uniform, for this portion it gives the same result. Most of the calibration error resulted simply from the different path length between the design path and the measured path. The results of the integration on the equivalent path are given in Table 1. The corrected calibration has been used to generate a new polynomial for BXS which was implemented in the control system.

43 PARTICLE ACCELERATORS↗

Extended temperature regions of multiferroicity in nanoscale CuO

We have measured the magnetic susceptibility and heat capacity of CuO nanoparticles (16 nm) from 2 K to 400 K using a Quantum Design Physical Properties Measurement System (PPMS). The magnetization curves, acquired at various field strengths from 0 Oe to 50 kOe, are similar to literature data of bulk and nanoscale CuO showing a minimum at about 150 K, an upturn as temperature approaches 0 K, and a broad maximum at high temperatures extending beyond 400 K. The heat capacity data between 200 K and 400 K show several broad peaks. The number of these peaks and the temperatures at which they occur differ significantly from the magnetic transitions known to exist in bulk CuO. To further investigate these transitions in nanoscale CuO, we performed temperature dependent x-ray diffraction (XRD) at temperatures from 90 K to 700 K from which lattice parameters as a function of temperature were derived using a Rietveld refinement. Although no phase transitions were observed in these data, changes in the slopes of the lattice parameters are apparent at the transition temperatures observed in the heat capacity and susceptibility measurements. The various transitions in the heat capacity data are attributed to competing ferromagnetic and antiferromagnetic interactions caused by structural properties that are unique to nanophase CuO, and the temperature range of multiferroicity in nanoscale CuO is shown to extend to temperatures higher than those observed for bulk CuO. The heat capacity and temperature dependent XRD measurements are the first of their kind to be reported for CuO nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics

X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3{+-}2.5nmrms to 5.7{+-}0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic and electron transport properties of Co 2 Si nanomagnets

In this study, magnetotransport and ferromagnetism in thin films of Co 2 Si nanoclusters are investigated experimentally and theoretically. The nanoclusters are fabricated by an inert-gas condensation-type cluster-deposition method and have an average size of 11.3 nm. Unlike the bulk Co 2 Si that exhibits a very weak net magnetic moment only below 10 K, the nanoclusters exhibit room-temperature ferromagnetism with a substantial saturation magnetization. Key features of the system are its closeness to the Stoner transition, magnetic moments induced by spin polarization starting from surface atoms, and nonuniaxial anisotropy associated with the orthorhombic crystal structure of Co 2 Si . A method is introduced to determine the effective anisotropy using the experimental magnetization data of this complex system and its relationship with the two lowest-order nonuniaxial anisotropy constants. On decreasing temperature from 300 K, the nanoclusters show electron-transport properties unusual for a ferromagnetic metal, including an increase of Hall resistivity and a nonmonotonic change of negative magnetoresistance with a peak at around 100 K. The underlying physics is explained on the basis of the large polarization of surface spins and variation in the degree of their misalignments due to temperature-dependent effective anisotropy.

36 MATERIALS SCIENCE↗