Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Floquet Prethermalization with Lifetime Exceeding 90 s in a Bulk Hyperpolarized Solid

Here, we report the observation of long-lived Floquet prethermal states in a bulk solid composed of dipolar-coupled 13 C nuclei in diamond at room temperature. For precessing nuclear spins prepared in an initial transverse state, we demonstrate pulsed spin-lock Floquet control that prevents their decay over multiple-minute-long periods. We observe Floquet prethermal lifetimes $T^{'}_{2}$≈90.9 s, extended >60 000-fold over the nuclear free induction decay times. The spins themselves are continuously interrogated for ~10 min, corresponding to the application of ≈5.8×10 6 control pulses. The 13 C nuclei are optically hyperpolarized by lattice nitrogen vacancy centers; the combination of hyperpolarization and continuous spin readout yields significant signal-to-noise ratio in the measurements. This allows probing the Floquet thermalization dynamics with unprecedented clarity. We identify four characteristic regimes of the thermalization process, discerning short-time transient processes leading to the prethermal plateau and long-time system heating toward infinite temperature. This Letter points to new opportunities possible via Floquet control in networks of dilute, randomly distributed, low-sensitivity nuclei. In particular, the combination of minutes-long prethermal lifetimes and continuous spin interrogation opens avenues for quantum sensors constructed from hyperpolarized Floquet prethermal nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing spin waves in Co 3 O 4 nanoparticles for magnonics applications

The magnetic properties of spinel nanoparticles can be controlled by synthesizing particles of a specific shape and size. The synthesized nanorods, nanodots and cubic nanoparticles have different crystal planes selectively exposed on the surface. The surface effects on the static magnetic properties are well documented, while their influence on spin waves dispersion is still being debated. Our ability to manipulate spin waves using surface and defect engineering in magnetic nanoparticles is the key to designing magnonic devices. We synthesized cubic and spherical nanoparticles of a classical antiferromagnetic material Co 3 O 4 to study the shape and size effects on their static and dynamic magnetic proprieties. Using a combination of experimental methods, we probed the magnetic and crystal structures of our samples and directly measured spin wave dispersions using inelastic neutron scattering. We found a weak, but unquestionable, increase in exchange interactions for the cubic nanoparticles as compared to spherical nanoparticle and bulk powder reference samples. Interestingly, the exchange interactions in spherical nanoparticles have bulk-like properties, despite a ferromagnetic contribution from canted surface spins.

36 MATERIALS SCIENCE↗

Magnetically Tunable Polariton Cavities in van der Waals Heterostructures

Nanophotonic cavities are the foundation for a broad spectrum of applications, including quantum sensing, on-chip communication, and cavity quantum electrodynamics. In van der Waals (vdW) materials, these cavities can harness polaritons, which are quasiparticles emerging from photon interactions with excitons, plasmons, or phonons that are confined in microscopic sample flakes. Hybrid phonon–plasmon cavities leverage the long lifetimes of phonons and good tunability of plasmons, but their reconfigurability remains fundamentally limited. Here, in this work, we introduce a magnetic-field-tuning mechanism for polaritonic cavities in a vdW heterostructure. Specifically, we demonstrate that the primary Landau transition in magnetized charge-neutral graphene can be harvested for controlling polaritonic cavity modes in a graphene-based phononic heterostructure. Additionally, we predict a magnetic-field-induced topological transition in the polariton isofrequency contour, causing a nontrivial cavity mode profile redistribution. Our study underscores the versatility of Landau-based nanophotonic cavities, offering new paradigms for the design and manipulation of light–matter interactions at the nanoscale.

36 MATERIALS SCIENCE↗

Generation and Control of Self-Organized Nonlinear Kinetic Structures in High Energy Density Plasmas in the Presence of Intense Magnetic Fields and Ultrashort Laser Pulses

Goals were to study the interplay between electron plasma waves (EPW), KEEN waves and externally generated magnetic fields. In particular, the Weibel instability B field generation process and its interrelationship with the existence of nonlinear EPWs in high energy density plasmas. We focused on a number of models of how Kinetic, Nonlinear Electron Plasma Waves, KNL-EPW and KEEN waves create anisotropic electron velocity distribution functions, e- VDF, and how these anisotropic e- VDFs in turn drive the Weibel instability and generate B fields. Our goal is to control the SRS and SKEENS processes that generate the KNL-EPW, control the anisotropy, and thus also control the dynamics of the resulting B fields, their influence on the transport coefficients and heat transport that results, their modification of SRS itself and the reinforced anisotropy driven loop gain.

(Kinetic electrostatic electron nonlinear) KEEN wa↗

Performance of large electron energy filter in large volume plasma device

This paper describes an in-house designed large Electron Energy Filter (EEF) utilized in the Large Volume Plasma Device (LVPD) [S. K. Mattoo, V. P. Anita, L. M. Awasthi, and G. Ravi, Rev. Sci. Instrum. 72, 3864 (2001)] to secure objectives of (a) removing the presence of remnant primary ionizing energetic electrons and the non-thermal electrons, (b) introducing a radial gradient in plasma electron temperature without greatly affecting the radial profile of plasma density, and (c) providing a control on the scale length of gradient in electron temperature. A set of 19 independent coils of EEF make a variable aspect ratio, rectangular solenoid producing a magnetic field (B{sub x}) of 100 G along its axis and transverse to the ambient axial field (B{sub z} ∼ 6.2 G) of LVPD, when all its coils are used. Outside the EEF, magnetic field reduces rapidly to 1 G at a distance of 20 cm from the center of the solenoid on either side of target and source plasma. The EEF divides LVPD plasma into three distinct regions of source, EEF and target plasma. We report that the target plasma (n{sub e} ∼ 2 × 10{sup 11} cm{sup −3} and T{sub e} ∼ 2 eV) has no detectable energetic electrons and the radial gradients in its electron temperature can be established with scale length between 50 and 600 cm by controlling EEF magnetic field. Our observations reveal that the role of the EEF magnetic field is manifested by the energy dependence of transverse electron transport and enhanced transport caused by the plasma turbulence in the EEF plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DIII-D research advancing the physics basis for optimizing the tokamak approach to fusion energy

DIII-D physics research addresses critical challenges for the operation of ITER and the next generation of fusion energy devices. This is done through a focus on innovations to provide solutions for high performance long pulse operation, coupled with fundamental plasma physics understanding and model validation, to drive scenario development by integrating high performance core and boundary plasmas. Substantial increases in off-axis current drive efficiency from an innovative top launch system for EC power, and in pressure broadening for Alfven eigenmode control from a co-/counter-I p steerable off-axis neutral beam, all improve the prospects for optimization of future long pulse/steady state high performance tokamak operation. Fundamental studies into the modes that drive the evolution of the pedestal pressure profile and electron vs ion heat flux validate predictive models of pedestal recovery after ELMs. Understanding the physics mechanisms of ELM control and density pumpout by 3D magnetic perturbation fields leads to confident predictions for ITER and future devices. Validated modeling of high-Z shattered pellet injection for disruption mitigation, runaway electron dissipation, and techniques for disruption prediction and avoidance including machine learning, give confidence in handling disruptivity for future devices. For the non-nuclear phase of ITER, two actuators are identified to lower the L–H threshold power in hydrogen plasmas. With this physics understanding and suite of capabilities, a high poloidal beta optimized-core scenario with an internal transport barrier that projects nearly to Q = 10 in ITER at ~8 MA was coupled to a detached divertor, and a near super H-mode optimized-pedestal scenario with co-I p beam injection was coupled to a radiative divertor. The hybrid core scenario was achieved directly, without the need for anomalous current diffusion, using off-axis current drive actuators. Also, a controller to assess proximity to stability limits and regulate β N in the ITER baseline scenario, based on plasma response to probing 3D fields, was demonstrated. Finally, innovative tokamak operation using a negative triangularity shape showed many attractive features for future pilot plant operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Permanent magnets for ELM suppression in tokamaks: feasibility and operational compatibility

Permanent magnets can provide static magnetic fields without power supplies or feed lines, offering a simpler alternative to conventional electromagnets in tokamaks. This work examines permanent magnet arrays (PMAs) for edge localized mode (ELM) control in double-null (DN) configurations, where traditional RMP coils exhibit limited effectiveness. Linear plasma response calculations using IPEC assess high-field-side (HFS) permanent magnet placement, benchmarking performance against DIII-D low-field-side (LFS) internal coils (I-coils) while evaluating engineering constraints. Modeling results demonstrate that HFS permanent magnet configurations generate HFS plasma response amplitudes more than 5 times larger than conventional I-coil systems. While other resonant response metrics show comparable or reduced response relative to I-coils, the combination of conventional RMP systems and permanent magnets is expected to provide enhanced performance. Operational impact assessments of persistent magnetic fields, including sideband field effects and startup/ramp-up compatibility, reveal acceptable performance within established operational boundaries. This analysis establishes PMAs as a technically viable approach for DN ELM control with reductions in system complexity, motivating further experimental validation on existing tokamak facilities.

3D magnetic perturbation↗

Magnetic shear effects on plasma transport and turbulence at high electron to ion temperature ratio in DIII-D and JT-60U plasmas

We demonstrated negative magnetic shear in DIII-D and JT-60U in order to mitigate the confinement degradation typically observed with increasing the electron to ion temperature ratio (T-e/T-i). In recent experiments in DIII-D negative central magnetic shear (NCS) discharges, the thermal transport in the internal transport barrier formed around the radius of the minimum safety factor (q(min)) remained almost constant and modestly increased in the region outside of q(min) compared to the positive shear (PS) case, when T-e/T-i increased from about 0.8 to 1.1 through electron cyclotron heating (ECH). The benefit of NCS extending into the region outside of qmin can be explained by the lower magnetic shear in the NCS plasma over the plasma radius relative to the PS plasma. Reduced confinement degradation at high T-e/T-i with NCS plasmas was commonly observed in DIII-D and JT-60U. Furthermore, the mechanism of the different transport responses between the NCS and PS plasmas has been assessed in terms of fluctuation measurements and gyrokinetic simulations in DIII-D; NCS gave a smaller rise in the low-wavenumber broadband turbulent fluctuations with the increase in T-e/T-i compared with the PS case. This is consistent with gyrokinetic simulations, and this shows a smaller rise in the growth rates of the ion temperature gradient mode in the NCS plasmas, with increasing T-e/T-i. Gyrokinetic simulations also showed a change in the stability of the electron modes with ECH applied, consistent with higher-wavenumber fluctuation measurements, although more detailed simulations are needed to give a quantitative explanation for the experimental observations. Control of q-profile and magnetic shear will allow confinement improvement in future machines with dominant electron heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in 3D transient plasma dynamics and control through MHD and hybrid fluid-kinetic simulations with JOREK

Transient phenomena and their control are of high relevance in magnetic confinement fusion plasmas to guarantee a stable and safe plasma operation. Interpretative simulations can maximize the insights gained from experiments on present machines and predictive simulations can help in the preparation of design, mitigation techniques and operational scenarios for future devices. In this article, we provide an overview of recent advances and novel scientific results obtained with the 3D non-linear hybrid fluid-kinetic code JOREK, covering physics of plasma transients from the core to the scrape-off layer (SOL) both for tokamak and stellarator devices. Substantial progress was made in the physics understanding, model validation with experiments and experiment interpretation, thus, giving confidence for predictions to devices like DTT, ITER and DEMO. The topics addressed comprise a wide range: the edge physics of new operation scenarios and edge localized mode suppression; major disruptions with a focus on runaway electrons and vertical displacement events as well as disruption mitigation by shattered pellet injection; the physics mechanisms and operational limits of the flux pumping regime for sawtooth control; MHD limits of stellarators and work towards incorporating advanced edge/SOL/exhaust dynamics; continuing improvements of the code for more efficient hybrid simulations on conventional and accelerated high performance computing architectures.

disruptions↗

SU-F-BRA-02: Electromagnetic Tracking in Brachytherapy as An Advanced Modality for Treatment Quality Assurance

Purpose: To present the use of Electromagnetic Tracking (EMT) for quality assurance in brachytherapy by means of phantom studies and to assess the clinical applicability of EMT during HDR breast brachytherapy. Methods: An EMT system was investigated to examine its suitability for clinical applications in brachytherapy. A field generator served as electromagnetic field emitter. Sensors (magnetic sensitive only), connected to a control unit, were used and their respective position and orientation inside a pre-defined measurement volume (500 mm cube length) determined. Up to three 6DoF sensors were placed on the phantom’s surface to obtain additional reference coordinates used to derive relative measured positions of a smaller 5DoF sensor inserted in the 6F catheters of the implant. The catheters were successively measured by manual displacement of the sensor at ∼40 mm/s. The measured catheter tracks, acquired multiple times at various locations (CT and treatment room), were smoothed, divided into intervals (2.5 mm dwell step size), registered (rigid Iterative Closest Point transformation) and compared against the known phantom geometry. Results: The reference coordinates were used to exclude the influence of external (e.g., respiratory-induced) motion. Precision tests in a clinical setting showed variances below 1 mm (translational) and 1° (rotational), respectively. Our method for catheter reconstruction preserved the length of the tracked catheter (within 1 mm). The measured tracking accuracy was 1±0.3 mm (maximum: 2 mm). The results are less accurate in environments potentially interfering with the magnetic field, e.g., in the vicinity of ferromagnetic table components. Conclusion: Our EMT system is able to perform reproducible and accurate catheter tracking and reconstruction. Currently, measurements of the implant geometry in HDR breast treatments are initiated. Online implant monitoring by means of EM tracking may be a first step towards advanced brachytherapy treatment QA. The study was financially supported by ELEKTA | Nucletron. There are no further disclosures and conflicts.

60 APPLIED LIFE SCIENCES↗

Modulating Oxide‐Based Quantum Materials by Ion Implantation

Ion implantation has emerged as a powerful tool for manipulating and investigating oxide quantum materials, where strong electron correlations give rise to exotic phases and functionalities. This Review examines how controlled ion bombardment enables targeted modulation of structural, electronic, and magnetic properties in complex oxides. Recent advances in ion beam techniques is analyzed that provide unprecedented control over defect profiles, from point defects to extended damage cascades. In application, ion irradiation has demonstrated the ability to tune quantum phenomena including metal‐insulator transitions, magnetism, and superconductivity through selective doping, defect creation, and lattice strain. The ability to write quantum states with nanoscale precision using focused ion beams is opening new paths for quantum device fabrication. Challenges in understanding radiation damage mechanisms in strongly correlated systems is discussed, and identify opportunities for designing quantum functionality through defect‐engineering approaches. The technique's demonstrated capability to write quantum states with nanoscale precision, combined with its compatibility with existing semiconductor processing infrastructure, suggests a clear pathway for translating fundamental discoveries in quantum materials into practical technological applications.

defect engineering↗

The CNAO dose delivery system for modulated scanning ion beam radiotherapy

Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing comparable performances and are presently in use on the CNAO beam lines for clinical activity. Conclusions: The dose delivery system described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. At the time of writing, it has been used to treat more than 350 patients and it has proven to guide and control the therapeutic pencil beams reaching performances well above clinical requirements. In particular, in terms of dose accuracy and stability, daily quality assurance measurements have shown dose deviations always lower than the acceptance threshold of 5% and 2.5%, respectively.

60 APPLIED LIFE SCIENCES↗

An NCN-pincer ligand dysprosium single-ion magnet showing magnetic relaxation via the second excited state

Single-molecule magnets are compounds that exhibit magnetic bistability purely of molecular origin. The control of anisotropy and suppression of quantum tunneling to obtain a comprehensive picture of the relaxation pathway manifold, is of utmost importance with the ultimate goal of slowing the relaxation dynamics within single-molecule magnets to facilitate their potential applications. Combined ab initio calculations and detailed magnetization dynamics studies reveal the unprecedented relaxation mediated via the second excited state within a new DyNCN system comprising a valence-localized carbon coordinated to a single dysprosium(III) ion. The essentially $C_{2v}$ symmetry of the Dy III ion results in a new relaxation mechanism, hitherto unknown for mononuclear Dy III complexes, opening new perspectives for means of enhancing the anisotropy contribution to the spin-relaxation barrier.

36 MATERIALS SCIENCE↗

Behavior of moving plasma in solenoidal magnetic field in a laser ion source

In a laser ion source, a solenoidal magnetic field is useful to guide the plasma and to control the extracted beam current. However, the behavior of the plasma drifting in the magnetic field has not been well understood. Therefore, to investigate the behavior, we measured the plasma ion current and the total charge within a single pulse in the solenoid by changing the distance from the entrance of the solenoid to a detector. We observed that the decrease of the total charge along the distance became smaller as the magnetic field became larger and then the charge became almost constant with a certain magnetic flux density. The results indicate that the transverse spreading speed of the plasma decreased with increasing the field and the plasma was confined transversely with the magnetic flux density. We found that the reason of the confinement was not magnetization of ions but an influence induced by electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-controlled direct laser acceleration enabled by longitudinal variation of the laser-driven quasi-static plasma magnetic field

Direct laser acceleration (DLA) enables energy transfer from an ultra-high-intensity laser to plasma electrons and underpins many laser-driven particle and radiation-source concepts. A laser-driven azimuthal plasma magnetic field is a key player in this process: it confines energetic electrons, induces betatron oscillations, and makes possible a resonant interaction between the betatron motion and the laser field. While this betatron resonance can enhance electron energy gain, the gain itself generally drives frequency detuning and promotes largely reversible energy exchange that limits net acceleration. Here we show, using a test-electron model with prescribed fields, that a slow longitudinal increase of the quasi-static plasma magnetic field qualitatively changes DLA by introducing hysteresis in the ratio of the betatron frequency to the laser frequency experienced by the electron, so that this ratio depends on the prior evolution of the electron even at the same energy. This hysteresis enables phase control of the electron-laser energy exchange and suppresses the usual reversibility of DLA, allowing electrons to retain the acquired energy and sustain energy gain without intermittent losses.

direct laser acceleration↗

Tuning the magnetic properties of the spin-split antiferromagnet MnTe through pressure

The hexagonal antiferromagnet MnTe has attracted enormous interest as a prototypical example of a spin-compensated magnet in which the combination of crystal and spin symmetries lifts the spin degeneracy of the electron bands without the need for spin-orbit coupling, a phenomenon called nonrelativistic spin splitting (NRSS). Subgroups of NRSS are determined by the specific spin-interconverting symmetry that connects the two opposite-spin sublattices. In MnTe, this symmetry is rotation, leading to the subgroup with spin splitting away from the Brillouin zone center, often called altermagnetism. MnTe also has the largest spontaneous magnetovolume effect of any known antiferromagnet, implying strong coupling between the magnetic moment and volume. This magnetostructural coupling offers a potential knob for tuning the spin-splitting properties of MnTe. Here, we use neutron diffraction with in situ applied pressure to determine the effects of pressure on the magnetic properties of MnTe and further explore this magnetostructural coupling. We find that applying pressure significantly increases the Néel temperature, but decreases the ordered magnetic moment. We explain this as a consequence of strengthened magnetic exchange interactions under pressure, resulting in higher 𝑇 N , with a simultaneous reduction of the local moment of individual Mn atoms, described here via density functional theory. This reflects the increased orbital hybridization and electron delocalization with pressure. In conclusion, these results shed light on the competition between magnetic exchange interactions and the strength of individual magnetic moments and show that the magnetic properties of MnTe can be controlled by pressure, opening the door to improved properties for spintronic applications through tuning via physical or chemical pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photon assisted tunneling through three quantum dots with spin-orbit-coupling

The effect of an ac electric field on quantum transport properties in a system of three quantum dots, two of which are connected in parallel, while the third is coupled to one of the other two, is investigated theoretically. Based on the Keldysh nonequilibrium Green's function method, the spin-dependent current, occupation number, and spin accumulation can be obtained in our model. An external magnetic flux, Rashba spin-orbit-coupling (SOC), and intradot Coulomb interactions are considered. The magnitude of the spin-dependent average current and the positions of the photon assisted tunneling (PAT) peaks can be accurately controlled and manipulated by simply varying the strength of the coupling and the frequency of the ac field. A particularly interesting result is the observation of a new kind of PAT peak and a multiple-PAT effect that can be generated and controlled by the coupling between the quantum dots. In addition, the spin occupation number and spin accumulation can be well controlled by the Rashba SOC and the magnetic flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controllable strain-induced uniaxial anisotropy of Fe{sub 81}Ga{sub 19} films deposited on flexible bowed-substrates

We propose a convenient method to induce a uniaxial anisotropy in magnetostrictive Fe{sub 81}Ga{sub 19} films grown on flexible polyethylene terephthalate (PET) substrates by bending the substrate prior to deposition. A tensile/compressive stress is induced in the Fe{sub 81}Ga{sub 19} films when PET substrates are shaped from concave/convex to flat after deposition. The stressed Fe{sub 81}Ga{sub 19} films exhibit a significant uniaxial magnetic anisotropy due to the internal stress arising from changes in shape of PET substrates. The easy axis is along the tensile stress direction and the coercive field along easy axis is increased with increasing the internal tensile stress. The remanence of hard axis is decreased with increasing the compressive stress, while the coercive field is almost unchanged. A modified Stoner-Wohlfarth model with considering the distribution of easy axes in polycrystalline films is used to account for the magnetic properties tuned by the strain-controlled magnetoelastic anisotropy in flexible Fe{sub 81}Ga{sub 19} films. Our investigations provide a convenient way to induce uniaxial magnetic anisotropy, which is particularly important for fabricating flexible magnetoelectronic devices.

36 MATERIALS SCIENCE↗