Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Pack-boriding of Fe-Mn binary alloys: Characterization and kinetics of the boride layers

In this work, the boronizing of Fe-Mn binary alloys at 0.42, 0.76 and 0.94 wt.% Mn was carried out in a solid medium using the powder pack method. In this method, commercial Ekabor-II boron source and activator (ferro-silicon) were thoroughly mixed to form the boriding medium. The samples were boronized in an electrical resistance furnace for exposure times of 2, 4, 6 and 8 h at 1173 K under atmospheric pressure and a series of boronized samples in the temperature range 1073-1373 K for 3 h. After the furnace process, boronized samples were removed from the furnace and cooled in air. Afterwards, the boride layers generated by the pack-boronizing process were characterized by optical microscopy, scanning electron microscopy, XRD analysis, Vickers microhardness and tensile testing. The generated boride layers, showing a saw-tooth morphology, had a surface microhardness in the range 1400-1270 HV0.1. It was shown that the values of yield stresses and ultimate tensile stresses were increased as the Mn content increases in the boronized Fe-Mn binary alloys. In contrast, the values of elongations determined from the stress-strain curves were decreased. Furthermore, it was found that the calculated mean value of the activation energy of boron diffusion was close to 119 J/mol.

36 MATERIALS SCIENCE↗

Experiment vs simulation RT WFNDEC 2014 benchmark: CIVA results

The French Atomic Energy Commission and Alternative Energies (CEA) has developed for years the CIVA software dedicated to simulation of NDE techniques such as Radiographic Testing (RT). RT modelling is achieved in CIVA using combination of a determinist approach based on ray tracing for transmission beam simulation and a Monte Carlo model for the scattered beam computation. Furthermore, CIVA includes various detectors models, in particular common x-ray films and a photostimulable phosphor plates. This communication presents the results obtained with the configurations proposed in the World Federation of NDEC 2014 RT modelling benchmark with the RT models implemented in the CIVA software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Role of Mathematical Methods in Efficiency Calibration and Uncertainty Estimation in Gamma Based Non-Destructive Assay - 12311

Mathematical methods are being increasingly employed in the efficiency calibration of gamma based systems for non-destructive assay (NDA) of radioactive waste and for the estimation of the Total Measurement Uncertainty (TMU). Recently, ASTM (American Society for Testing and Materials) released a standard guide for use of modeling passive gamma measurements. This is a testimony to the common use and increasing acceptance of mathematical techniques in the calibration and characterization of NDA systems. Mathematical methods offer flexibility and cost savings in terms of rapidly incorporating calibrations for multiple container types, geometries, and matrix types in a new waste assay system or a system that may already be operational. Mathematical methods are also useful in modeling heterogeneous matrices and non-uniform activity distributions. In compliance with good practice, if a computational method is used in waste assay (or in any other radiological application), it must be validated or benchmarked using representative measurements. In this paper, applications involving mathematical methods in gamma based NDA systems are discussed with several examples. The application examples are from NDA systems that were recently calibrated and performance tested. Measurement based verification results are presented. Mathematical methods play an important role in the efficiency calibration of gamma based NDA systems. This is especially true when the measurement program involves a wide variety of complex item geometries and matrix combinations for which the development of physical standards may be impractical. Mathematical methods offer a cost effective means to perform TMU campaigns. Good practice demands that all mathematical estimates be benchmarked and validated using representative sets of measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain age cracking in a simulated heat affected zone of Inconel 740H laser-powder bed fusion components

Inconel® 740H components produced via laser-powder-bed fusion (L-PBF) additive manufacturing are ideal for supercritical CO2 primary heat exchangers. Arc welding is often needed, and subsequent post-weld heat treatment aging at 790–840 °C is required to improve strength via gamma prime (γ’) precipitation; however, strain age cracking (SAC) can occur in the heat affected zone (HAZ) during this process. This study uses stress relaxation testing at 800 °C on simulated HAZ specimens from vertically and horizontally built L-PBF IN740H to assess SAC susceptibility across heating rates of 40–3480 °C/h and weld-induced strains of 3–10 %. Vertical builds require greater mechanical energy input and exhibit longer times to fracture than horizontal builds, and time to fracture occurs sooner at slower heating rates. Creep voids were observed in γ’-denuded regions along grain boundaries, and cracking propagated along migrated grain boundaries and at interfaces between elongated secondary phases (γ’ or carbides) and the γ-matrix.

14 SOLAR ENERGY↗

A glove-likeability study of specially-treated gloves in the detonator manufacturing and packaging industry

We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate that the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of gamma radiation on zircaloy-4 corrosion - 2016-0029

A key microstructural feature of irradiated oxide films that form on Zircaloy-4 is the development of significant amounts of interconnected porosity or microcracking, particularly along oxide grain boundaries. This development disrupts the protective nature of the barrier layer, effectively resulting in an increase in the observed post-transition corrosion rates. This observation suggests that some aspect of oxide dissolution may be occurring. It is noteworthy that when exposed to photons with energies greater than that of the oxide band gap, n-type semiconducting oxides are prone to dissolution. Because zirconia (ZrO{sub 2}) is an n-type semiconductor, it is plausible that high-energy photons may play an important role in corrosion. In an operating nuclear reactor, neutron and gamma flux levels are closely interrelated because they arise, for the most part, from the same originating process (i.e., the fissioning of nuclear fuel). Thus, it is difficult to isolate the independent effects of neutron and gamma radiation on corrosion. It is, however, theoretically conceivable to assess the role that gamma radiation may have on corrosion by comparing instances where variations in radiation environment exists; specifically by comparing where variations in gamma flux levels relative to neutron flux levels within different regions of a reactor or from reactor to reactor exist. Comparisons of the corrosion rates obtained between two different reactors (the Halden test reactor and the advanced test reactor [ATR]) that have differing gamma-to-neutron ratios were performed. In addition, an examination of corrosion rate data from the ATR, in which a variation in gamma-to-neutron flux ratio exists, was also conducted. Results are presented, from both assessments, which indicate that gamma radiation plays a role in the irradiated corrosion behavior of Zircaloy-4. In addition to a discussion of experimental data, potential mechanisms associated with photon-induced oxide dissolution of n-type semiconducting oxides, such as zirconia, is also provided. (authors)

36 MATERIALS SCIENCE↗

Lost Circulation Materials in Geothermal Drilling: Thermal Degradation, Viscosity, Compression, and Flow Loop Tests

This dataset provides a set of experimental data on the performance of lost circulation materials (LCMs) used in geothermal drilling operations. It includes results from four distinct tests: thermal degradation, viscosity measurements, compression tests, and high-temperature flow loop experiments. The materials tested, such as cedar fiber, cotton seed hulls, magma fiber, microcellulose, and sawdust, were analyzed under a range of conditions to assess their effectiveness in mitigating fluid losses in geothermal wells. Data on thermal degradation explores mass loss, water loss, and gas release for each material when subjected to temperatures between 90C and 250C. Viscosity measurements capture the behavior of LCM mixtures under different temperatures, while compression tests investigate the structural integrity of both undegraded and thermally degraded materials. The high-temperature flow loop experiments simulate geothermal well conditions, analyzing how different materials and mixtures affect fluid flow and sealing performance in a fractured reservoir environment. In addition to the experimental data, the dataset includes photos documenting the materials, schematics of test setups, and several published manuscripts that provide detailed insights into the experimental methods and findings.

15 GEOTHERMAL ENERGY↗

Real-time visualization of impact damage in monolithic silicon carbide and fibrous silicon carbide ceramic composite

Impact resistance from foreign debris is a critical requirement for brittle ceramic and ceramic composite materials intended for use in the hot-section of gas turbine engines. A design to mitigate against such impact failures necessitates a detailed understanding of the driving failure mechanisms. The present study introduces a unique time-resolved experimental method which advances the latter effort. Specifically, a pulsed synchrotron X-ray source, in phase contrast imaging (PCI) configuration, is used as a medium, to visually characterize the evolution of damage inside the target materials during impact. As a proof of concept, two types of ceramic materials were tested: monolithic silicon carbide and fibrous silicon carbide composite. Impact was performed using a light-gas gun and 1.5 mm diameter spheres of partially stabilized zirconia (PSZ) and silicon nitride (Si 3 N 4 ). The retrieved dynamic X-ray image sequences provided clear outlines of the damage features. In the case of the monolithic ceramic, the impact by a PSZ projectile initially produced a cone crack and complete failure resulted by extension of a median crack. By contrast, the fibrous composite deformed readily prior to cone crack formation. Nearly identical damage features were observed in the monolith for the Si 3 N 4 projectile, with the exception of the added vertical tensile crack. For this same projectile, the fibrous ceramic showed very limited surface deformation and enhanced cone cracking and kinking of laminates along the crack path. The latter response is attributed to the change in projectile properties. Some of the target materials were recovered, and post-mortem analysis via scanning electron microscopy (SEM) showed correlation with observed X-ray damage profiles. Furthermore, simple Hertzian contact was used to estimate damage for the elastic portion of impact. This approach was found to yield a reasonable match with experimental results for the surface displacement near the contact interface.

36 MATERIALS SCIENCE↗

Colloidal crystal formation in a semiconductor quantum plasma

The static shielding and the far-field dynamical oscillatory wake potentials in an ion-implanted piezoelectric semiconductor with colloid ions as test particles have been investigated in detail. The dielectric response function of the semiconductor is contributed by the quantum effect of electrons through the Bohm potential and lattice electron-phonon coupling effects. It is found that the quantum effect causes tighter binding of the electrons reducing the quantum Debye shielding length and the effective length of the wake potential to several angstroms. Hence, a quasiquantum lattice of colloid ions can be formed in the semiconductor in the quantum scales giving rise to drastic modifications of the ion-implanted semiconductor properties.

36 MATERIALS SCIENCE↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Construction of a High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory, together with Lawrence Berkeley National Laboratory, is building a new High Field Vertical Magnet Test Facility (HFVMTF) to be situated in the Magnet Test Facility at Fermilab. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences, and will serve as a superconducting cable test facility for both communities. The background magnetic field for test samples is 15 T and will be produced by a magnet provided by LBNL operating at 1.9 K in superfluid helium. The samples will be placed in the background magnetic field, cooled to between 4.5 K and a user-specified upper limit, and will be powered with a super-conducting transformer at up to 100 kA. Additionally, this facility will be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program. Presently, the various tasks of the project are at different stages of execution, from conceptual to ready-for-construction designs. Here, this paper describes the parameters and design status of the pit construction, cryostat, heat exchanger, lambda plate, power system, and quench protection and monitoring systems of the facility.

43 PARTICLE ACCELERATORS↗

Mechanical Properties of Additively Manufactured 316L Stainless Steel Before and After Neutron Irradiation (FY21)

This report presents the materials property data of additively manufactured (AM) 316L stainless steel (SS) accumulated for the assessment of core materials in the Transformational Challenge Reactor (TCR) program. The TCR manufacturing approach includes using the laser powder bed fusion (LPBF) method for metallic (316L and Inconel 718) components. To assess the mechanical performance of printed components in reactor-relevant conditions and build a property database for the AM materials, mechanical tests and evaluations were performed before and after neutron irradiation. Miniature tensile specimens were irradiated in the High Flux Isotope Reactor to 0.2, 2, 8, and 10 dpa at target temperatures of 300 and 600°C. Postirradiation evaluation for the 0.2 and 2 dpa specimens was performed during FY20 and FY21, and the results are presented and discussed in this document.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Shear Strength Correlations for Kaolin/Water Slurries: A Comparison of Recent Measurements with Historical Data

This report documents testing funded by CH2M Hill Plateau Remediation and performed by Pacific Northwest National Laboratory (PNNL) in collaboration with Fauske and Associates, LLC (FAI) to determine the behavior of vessel spanning bubbles. The shear strengths of four samples of kaolin/water mixtures obtained by PNNL from FAI were measured and are reported here. The measured shear strengths of these samples were then used to determine how the Rassat correlation fit these new measurements or if a new correlation was needed. These results were then compared with previously reported data.

54 ENVIRONMENTAL SCIENCES↗

Plastic deformation and creep damage evaluations of type 316 austenitic stainless steels by EBSD

The inspection method of plastic and/or creep deformations has been required as the quantitative damage estimation procedure for structural components especially used in electric power plants. In this study, the method using electron backscatter diffraction (EBSD) was applied to the deformation and damage evaluation of austenitic stainless steels strained by tension or compression at room temperature and also tested in creep at high temperature. It was found that the value of Grain Average Misorientation (GAM) which showed the average misorientation for the whole observed area including over several dozen grains, was a very useful parameter for quantifying the microstructural change as either the plastic or creep strain increased. The unique linear correlation was obtained between GAM and plastic strain in tension and compression. For creep damage evaluation, the difference of grain average misorientation from the value of the unstrained specimen ({Delta}GAM) showed an excellent correlation with the inelastic strain below strain at which the tertiary creep began.

36 MATERIALS SCIENCE↗

Three-dimensional ultrasonic imaging of concrete elements using different SAFT data acquisition and processing schemes

Ultrasonic testing systems using transducer arrays and the SAFT (Synthetic Aperture Focusing Technique) reconstruction allow for imaging the internal structure of concrete elements. At one-sided access, three-dimensional representations of the concrete volume can be reconstructed in relatively great detail, permitting to detect and localize objects such as construction elements, built-in components, and flaws. Different SAFT data acquisition and processing schemes can be utilized which differ in terms of the measuring and computational effort and the reconstruction result. In this contribution, two methods are compared with respect to their principle of operation and their imaging characteristics. The first method is the conventional single-channel SAFT algorithm which is implemented using a virtual transducer that is moved within a transducer array by electronic switching. The second method is the Combinational SAFT algorithm (C-SAFT), also named Sampling Phased Array (SPA) or Full Matrix Capture/Total Focusing Method (TFM/FMC), which is realized using a combination of virtual transducers within a transducer array. Five variants of these two methods are compared by means of measurements obtained at test specimens containing objects typical of concrete elements. The automated SAFT imaging system FLEXUS is used for the measurements which includes a three-axis scanner with a 1.0 m × 0.8 m scan range and an electronically switched ultrasonic array consisting of 48 transducers in 16 groups. On the basis of two-dimensional and three-dimensional reconstructed images, qualitative and some quantitative results of the parameters image resolution, signal-to-noise ratio, measurement time, and computational effort are discussed in view of application characteristics of the SAFT variants.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphite Characterization: Baseline Variability Analysis Report

The Idaho National INL’s Baseline Material Property program provides many measurements of different material properties on a variety of nuclear graphite grades being investigated for irradiation-induced changes in material properties. The baseline material properties provide an unirradiated reference for comparison with measurements of those properties after irradiation. This study describes how uncertainty, or variance, in estimates of important material properties, like compressive strength, may depend on sample size, sample distribution and parameter estimation methods. Compressive strength data from two large collections of specimens from a billet of PCEA graphite (sample size = 230) and a billet of IG-110 graphite (sample size = 48) are used to illustrate these dependencies. The grades of graphite used represent approximate end members in terms of relative variability in strength measurements. Monte Carlo simulation and bootstrapping methods were used to examine variance in Weibull-parameter estimates as a function of sample size. Results were consistent with what previous statistical analyses have shown about the relationship between sample size and width of the confidence interval for maximum likelihood (ML) estimated parameters when samples are repeatedly drawn from a Weibull distribution. As a function of sample size, the precision of the modulus estimate increases faster than that of the characteristic strength. The modulus maximum likelihood estimates (MLEs) are biased for low sample sizes. The American Society for Testing and Materials document ASTM D7846-16 provides equations that describe the dependence of the variance of parameter MLEs on sample size. Using the same methodology, we show that the polynomials provided for variance dependence on sample size are inaccurate for sample sizes greater than ~120. We provide approximations to that relationship that illustrate relative constancy for sample size > ~10, in the logspace relationship of the modulus variance and the log transformed characteristic strength variance. Bootstrapping provided a means of comparing Weibull parameters obtained using ASME’s guidance for specimen collection to those obtained using different weighting in a case where strength is related to position in a billet and to grain orientation and a single distribution is used to characterize the billet. ASME specifies that samples be collected with equal representation in all locations and grain orientations. Parameter values obtained using ASME’s method were different from those obtained using random sampling of the complete data sets, and this was particularly true for the PCEA data. In addition, while the ASME approach yielded more conservative parameters for the PCEA data, the opposite was true for the IG-110 data. The difference observed for the PCEA data set likely reflects the larger number of against-grain specimens collected, which had generally higher strength than the with-grain specimens. This emphasizes the importance of the dependence of strength on location or grain orientation and suggests that it may be prudent to weight specimen collection toward the weaker subgroups if a conservative estimate as desired, as the equal weighting method recommended by ASME would will not always provide the most conservative Weibull parameters. Because spatial correlations commonly exist in certain grades of graphite, future work may involve developing a methodology for parameter inference that relaxes the assumption of independent specimens. ASTM and ASME codes recommend different parameter estimation methods and models of the Weibull distribution in different situations. Descriptions of the effects on parameter estimates for the example billets used in this study provide an example of how the method may affect the parameter estimate, and how—in this case—that compares to differences due to other factors, such as sample size and dependence on grain orientation or sample location.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Production of Uranium from Seawater Using a Novel Polymer Adsorbent – Process Development and Cost Analysis (Final Scientific/Technical Report SBIR Phase II)

Research in developing techniques for extracting uranium from seawater is of considerable current interest. One reason which drives scientists to develop techniques of sequestering uranium from ocean is the prediction that the land-based uranium reserves would be depleted by the end of this century based on the current production rate. Uranium exists in seawater at a very low concentration (about 3 ppb) and as highly stable uranyl tris-carbonato complexes, primarily in the form Ca 2 [UO 2 (CO 3 ) 3 ]. Because of the enormous volume of seawater, the total amount of uranium in ocean is estimated to be a thousand times greater than the land-based uranium resources. As early as 1964, the idea of extracting uranium from seawater was discussed by Davies et al. in a Nature paper. In the past decades, many different materials were tested to evaluate their ability for sequestering uranium from seawater. Among them, amidoxime and carboxylate containing polymer fiber adsorbents appear most promising because of their high uranium adsorption capacity and stability in seawater. The carboxylate groups are necessary to make the polymer adsorbent hydrophilic whereas the amidoxime groups provide strong coordination sites for uranyl ions. Moreover, according to theoretical analysis, the adsorbability of uranium may involve synergistic effects of both amidoxime and carboxyl groups in the fiber adsorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Glass Monocapillary X-ray Optics And Their Applications In X-ray Microscopy

Elliptical, parabolic and Wolter type glass monocapillaries were fabricated for use as x-ray condensers in the energy range of 250 eV to 20 keV. On a routine basis a diameter error of +/-0.4 {mu}m and straightness error of 0.8 {mu}m (peak to valley) can be reached. The final test of condensers was performed at-wavelength by imaging the far field x-ray reflection intensity distribution using a laboratory microfocus x-ray source. For medium length condensers with a total length <80 mm, a total slope error of 40 murad rms was obtained. The applications in full-field x-ray microscopes and the future effort in developing capillary Wolter mirrors based on this technology are reported.

07 ISOTOPE AND RADIATION SOURCES↗