Applicability of a Bonner Shere technique for pulsed neutron in 120 GeV proton facility

The data on neutron spectra and intensity behind shielding are important for radiation safety design of high-energy accelerators since neutrons are capable of penetrating thick shielding and activating materials. Corresponding particle transport codes--that involve physics models of neutron and other particle production, transportation, and interaction--have been developed and used world-wide [1-8]. The results of these codes have been ensured through plenty of comparisons with experimental results taken in simple geometries. For neutron generation and transport, several related experiments have been performed to measure neutron spectra, attenuation length and reaction rates behind shielding walls of various thicknesses and materials in energy range up to several hundred of MeV [9-11]. The data have been used to benchmark--and modify if needed--the simulation modes and parameters in the codes, as well as the reference data for radiation safety design. To obtain such kind of data above several hundred of MeV, Japan-Fermi National Accelerator Laboratory (FNAL) collaboration for shielding experiments has been started in 2007, based on suggestion from the specialist meeting of shielding, Shielding Aspects of Target, Irradiation Facilities (SATIF), because of very limited data available in high-energy region (see, for example, [12]). As a part of this shielding experiment, a set of Bonner sphere (BS) was tested at the antiproton production target facility (pbar target station) at FNAL to obtain neutron spectra induced by a 120-GeV proton beam in concrete and iron shielding. Generally, utilization of an active detector around high-energy accelerators requires an improvement on its readout to overcome burst of secondary radiation since the accelerator delivers an intense beam to a target in a short period after relatively long acceleration period. In this paper, we employ BS for a spectrum measurement of neutrons that penetrate the shielding wall of the pbar target station in FNAL.

43 PARTICLE ACCELERATORS↗

Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA–600 kA (corresponding to charging voltage range of 14 kV–18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar–11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10{sup 9} neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear electric dipole moment of {sup 3}He

In the no-core shell model (NCSM) framework, we calculate the {sup 3}He electric dipole moment (EDM) generated by parity- and time-reversal violation in the nucleon-nucleon interaction. While the results are somehow sensitive to the interaction model chosen for the strong two- and three-body interactions, we demonstrate the pion-exchange dominance to the EDM of {sup 3}He, if the coupling constants for {pi}, {rho} and {omega}-exchanges are of comparable magnitude, as expected. Finally, our results suggest that a measurement of {sup 3}He EDM would be complementary to the currently planned neutron and deuteron experiments, and would constitute a powerful constraint to the models of the pion P- and T-violating interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation hardness of three-dimensional polycrystalline diamond detectors

The three-dimensional concept in particle detection is based on the fabrication of columnar electrodes perpendicular to the surface of a solid state radiation sensor. It permits to improve the radiation resistance characteristics of a material by lowering the necessary bias voltage and shortening the charge carrier path inside the material. If applied to a long-recognized exceptionally radiation-hard material like diamond, this concept promises to pave the way to the realization of detectors of unprecedented performances. We fabricated conventional and three-dimensional polycrystalline diamond detectors, and tested them before and after neutron damage up to 1.2 ×10{sup 16 }cm{sup −2}, 1 MeV-equivalent neutron fluence. We found that the signal collected by the three-dimensional detectors is up to three times higher than that of the conventional planar ones, at the highest neutron damage ever experimented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements in Yttrium Hydride Moderator Development

As microreactors evolve to become a more affordable and efficient worldwide energy source, the development of moderator material within the system to decrease the required mass of low-enriched uranium fuel is important. The use of low- instead of high-enriched uranium in small nuclear reactors stems from recent national policies associated with nonproliferation. New designs are being developed for a range of applications and nuclear space systems in particular. Using system geometries such as those described in this paper, the next step is to advance the technology readiness level of moderator material such as delta-yttrium hydride (YH x,x = 1.6–2.0 ) so that it can be qualified for use in a microreactor system. Although characterization of unirradiated material has been documented previously, to fully understand the performance of this material, behavior in relevant irradiation environments must occur. This paper describes the fabrication of yttrium hydride samples through innovative techniques and how these samples were tested in two relevant neutron environments. These two experiments include (1) a critical experiment performed at the National Criticality Experiments Research Center (NCERC) to evaluate reactivity changes in a neutron-critical environment and (2) irradiation in the Advanced Test Reactor (ATR) to assess structural integrity/material form, thermophysical data, hydrogen permeability, and other features post irradiation. For this purpose, hundreds of samples were fabricated for the NCERC and ATR experiments and are described within this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Excess wing in glass-forming glycerol and LiCl-glycerol mixtures detected by neutron scattering

The relaxational dynamics in glass-forming glycerol and glycerol mixed with LiCl is investigated using different neutron scattering techniques. The performed neutron spin echo experiments, which extend up to relatively long relaxation time scales of the order of 10 ns, should allow for the detection of contributions from the so-called excess wing. This phenomenon, whose microscopic origin is controversially discussed, arises in a variety of glass formers and, until now, was almost exclusively investigated by dielectric spectroscopy and light scattering. In conclusion, we show here that the relaxational process causing the excess wing can also be detected by neutron scattering, which directly couples to density fluctuations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2011 Status of the Automatic Alignment System for the National Ignition Facility

Automated alignment for the National Ignition Facility (NIF) is accomplished using a large-scale parallel control system that directs 192 laser beams along the 300-m optical path. The beams are then focused down to a 50-micron spot in the middle of the target chamber. The entire process is completed in less than 50 minutes. The alignment system commands 9,000 stepping motors for highly accurate adjustment of mirrors and other optics. 41 control loops per beamline perform parallel processing services running on a LINUX cluster to analyze high-resolution images of the beams and their references. This paper describes the status the NIF automatic alignment system and the challenges encountered as NIF development has transitioned from building the laser, to becoming a research project supporting a 24 hour, 7 day laser facility. NIF is now a continuously operated system where performance monitoring is increasingly more critical for operation, maintenance, and commissioning tasks. Equipment wear and the effects of high energy neutrons from fusion experiments are issues which alter alignment efficiency and accuracy. New sensors needing automatic alignment assistance are common. System modifications to improve efficiency and accuracy are prevalent. Handling these evolving alignment and maintenance needs while minimizing the impact on NIF experiment schedule is expected to be an on-going challenge for the planned 30 year operational life of NIF.

42 ENGINEERING↗

Multiple small angle neutron scattering: A new two-dimensional ultrasmall angle neutron scattering technique

We report on the demonstration experiment of the multiple small angle neutron scattering (MSANS) technique at a 5.6 m long neutron beam line, leading to a q resolution of 3x10{sup -4} A{sup -1}. The MSANS technique is based on two two-dimensional multihole apertures placed at the front end of the collimator and close to the sample, respectively. By choosing the proper MSANS geometry, individual diffraction patterns are superimposed leading to a large gain in intensity. Using MSANS as an option for standard small angle neutron scattering beam lines, the q resolution could be increased to 10{sup -5} A{sup -1} without dramatically sacrificing intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detailed Investigations of Neutron–Neutron Angular Correlations in Slow-Neutron-Induced Fission of {sup 233}U, {sup 235}U, and {sup 239}Pu

An experiment devoted to studying neutron–neutron angular correlations in the slow-neutroninduced fission of {sup 233}U, {sup 235}U and {sup 239}Pu nuclei was performed. The experimentally determined angular dependence of the number of neutron–neutron coincidences was compared with the results of a Monte Carlo simulation for various values of the neutron-detection threshold in the range between 490 and 2080 keV. It was found that the experimental angular distributions in question can be described well under the assumption that 2% to 5% of all prompt fission neutrons are emitted isotropically in the laboratory frame. Probably, such neutrons can be interpreted as so-called scission neutrons directly associated with the nuclear-rupture instant. Energy distributions of this component were also obtained from the present analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Integral Experiment Request 523 Feasibility Study (Summary Report)

This report documents the feasibility phase of the Critical Experiment Design (CED) conducted as part of integral experiment request (IER) 523. The purpose of IER-523 is to explore the effects of using 35 weight percent enriched uranium dioxide-beryllium oxide (UO 2 -BeO) material on critical configurations using the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories (Sandia). Preliminary experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The 20 Ne(d,p) 21 Ne Transfer Reaction in Relation to the s-Process Abundances

A study of the Ne-20(d,p)Ne-21 transfer reaction was performed using the Quadrupole Dipole Dipole Dipole (Q3D) magnetic spectrograph in Garching, Germany. The experiment probed excitation energies in Ne-21 ranging from 6.9 MeV to 8.5 MeV. The aim was to investigate the spectroscopic information of Ne-21 within the Gamow window of core helium burning in massive stars. Further information in this region will help reduce the uncertainties on the extrapolation down to Gamow window cross sections of the O-17(alpha,gamma)Ne-21 reaction. In low metallicity stars, this reaction has a direct impact on s-process abundances by determining the fate of O-16 as either a neutron poison or a neutron absorber. The experiment used a 22-MeV deuteron beam, with intensities varying from 0.5-1 mu A, and an implanted target of Ne-20 of 7 mu g/cm(2) in 40 mu g/cm(2) carbon foils. Sixteen Ne-21 peaks have been identified in the E-x = 6.9-8.5 MeV range, of which only thirteen peaks correspond to known states. Only the previously-known E-x = 7.960 MeV state was observed within the Gamow window.

Nsangu, C. T.↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Neutron powder diffraction study of the layer organic-inorganic hybrid iron(II) methylphosphonate-hydrate, Fe[(CD{sub 3}PO{sub 3})(D{sub 2}O)]

The crystal and magnetic structures of the hybrid organic-inorganic layer compound Fe[(CD{sub 3}PO{sub 3})(D{sub 2}O)] have been studied by neutron powder diffraction as a function of temperature down to 1.5 K. The neutron diffraction pattern recorded at 200 K shows that the fully deuterated compound crystallizes in one of the two known forms of the undeuterated Fe[(CH{sub 3}PO{sub 3})(H{sub 2}O)]. The crystal structure is orthorhombic, space group Pmn2{sub 1}, with the following unit-cell parameters: a=5.7095(1) A, b=8.8053(3) A and c=4.7987(1) A; Z=2. The crystal structure remains unchanged on cooling from 200 to 1.5 K. Moreover, at low temperature, Fe[(CD{sub 3}PO{sub 3})(D{sub 2}O)] shows a commensurate magnetic structure (k=(0,0,0)). As revealed by bulk susceptibility measurements on Fe[(CH{sub 3}PO{sub 3})(H{sub 2}O)], the magnetic structure corresponds to a canted antiferromagnet with a critical temperature T{sub N}=25 K. Neutron powder diffraction reveals that below T{sub N}=23.5 K the iron magnetic moments in Fe[(CD{sub 3}PO{sub 3})(D{sub 2}O)] are antiferromagnetically coupled and oriented along the b-axis, perpendicular to the inorganic layers. No ferromagnetic component is observable in the neutron powder diffraction experiment, due to its too small value (<0.1{mu}{sub B}). - Graphical abstract: Crystal structure and magnetic structure of Fe[(CD{sub 3}PO{sub 3})(D{sub 2}O)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Restart of the Transient Reactor Test (TREAT) Facility Neutron Radiography Program

The TREAT radiography system is used to perform neutron radiography of fuels, experiments, and other specimens before and after irradiation within the TREAT reactor. The TREAT neutron radiography facility performed approximately 5,000 radiographs by the spring of 1977. Originally built in 1958, the TREAT Facility was in operation until it was placed in a shutdown status in 1994. Following the Fukishima disaster and seeing a need for enhanced accident tolerant fuels, the United Stated Department of Energy decided to restart the TREAT facility and resume transient operations. In November 2017, the TREAT reactor was successfully restarted and is currently performing operational testing in preparation for initial experiment irradiations and transient testing. This paper discusses efforts to reactivate the TREAT neutron radiography facility. To characterize the neutron beam, gold foil activation measurements were made to determine an average neutron flux and flux profile. An open beam image provides the information about variations in the beam profile. In conclusion, a series of system qualification radiographs have been acquired to determine the effective image acquisition parameters, resulting image quality, and the relationships between the two.

36 MATERIALS SCIENCE↗

The LIBRA Experiment: Investigating Robust Tritium Accountancy in Molten FLiBe Exposed to a D-T Fusion Neutron Spectrum

The Liquid Immersion Blanket: Robust Accountancy (LIBRA) experiment will be a first-of-a-kind experiment to explore and develop the liquid immersion blanket (LIB) concept. The LIB is a radically simple molten–LiF-BeF2 (FLiBe)–salt tritium breeding blanket for deuterium-tritium (D-T)–fueled fusion power plants (FPPs) achieving a high tritium breeding ratio (TBR) in neutronics models. However, tritium breeding in FLiBe is inherently difficult to study experimentally. As a result, the coupled issues of FLiBe radiochemistry and tritium (T) transport are poorly understood. LIBRA approaches this challenge by simulating an FPP blanket environment using a D-T neutron generator and ≈ 1000 kg of FLiBe. LIBRA will investigate T breeding, containment, and extraction, coupled with FLiBe redox control and radiochemistry. The primary goal of LIBRA is to demonstrate robust T accountancy in blanket prototypical conditions. Here, T accountancy encompasses accurate predictions of T breeding in the FLiBe; detection and measurement of all T bred in LIBRA; and speciation of the T extracted from the FLiBe. Initial neutronics simulations of LIBRA indicate that a global TBR of ~ 1 is possible, where the TBR is defined as the number of tritons bred and extracted from FLiBe relative to the number of neutrons produced by D-T fusion reactions in the neutron generator. In this paper, we present the LIBRA concept and its scientific goals in the context of T breeding experiments. We also consider the potential impact of the LIB on the future fusion power industry, motivating further development of FLiBe-based T breeding research activities such as LIBRA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tabletop, ultrashort pulse photoneutron source driven by electrons from laser wakefield acceleration

Relativistic electron beams driven by laser wakefield acceleration were utilized to produce ultrashort neutron sources. The experiment was carried out on the 38 fs, ∼0.5 J, 800 nm Ti:Sapphire laser in the 10 TW UT3 laser lab at University of Texas at Austin. The target gas was a high density pulsed gas jet composed of 90% He and 10% N2. The laser pulse with a peak intensity of 1.5 × 1018 W/cm2 interacted with the target to create a cylindrical plasma channel of 60 μm radius (FWHM) and 1.5 mm length (FWHM). Electron beams of ∼80 pC with the Gaussian energy distribution centered at 37 MeV and a width of 30 MeV (FWHM) were produced via laser wakefield acceleration. Neutron fluences of ∼2.4 × 106 per shot with hundreds of ps temporal length were generated through bremsstrahlung and subsequent photoneutron reactions in a 26.6 mm thick tungsten converter. Results were compared with those of simulations using EPOCH and GEANT4, showing agreement in electron spectrum, neutron fluence, neutron angular distribution and conversion rate.

Jiao, X. J.↗

Critical Unresolved Region Integral Experiment Execution

Integral Experiments are a key aspect of validating nuclear data behavior and simulation capabilities. Further, integral experiments are the earliest form of validation of equations and codes. They have been used extensively since the 1940s. Today, simulation and predictive capabilities have improved greatly from 75 years ago, but nonetheless, integral experiments are still needed. As simulation capabilities improve, their uncertainties get much smaller. The current focus of many new experiments is understanding the intermediate energy range. The intermediate energy range does not have a wide application space and it can be challenging to design experiments that are sensitive to neutron energies in this region. The Zeus experiments evaluated highly enriched uranium (HEU) in the intermediate energy region. Building on the success and knowledge gained from the Zeus experiments, the Critical Unresolved Region Integral Experiment (CURIE) experiments were designed to evaluate HEU in the narrower unresolved resonance region (URR). These experiments were executed during June and July 2020 at the National Criticality Experiments Research Center (NCERC). The National Criticality Experiments Research Center (NCERC), operated by Los Alamos National Laboratory, is the only general purpose critical experiments facility in the United States of America. NCERC regularly designs and executes critical experiments and other measurements useful to a wide variety of fields including nuclear criticality safety, commercial nuclear energy, nonproliferation, and nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗