Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Study of {sup 12}C(p-vector,n-vector){sup 12}N(g.s.;1{sup +}) at 296 MeV and Nuclear Correlation Effects

We present measurements of the cross section and a complete set of polarization observables for the Gamow-Teller {sup 12}C(p-vector,n-vector){sup 12}N(g.s.;1{sup +}) reaction at an incident proton energy of 296 MeV. The complete set of polarization observables is used to separate the cross section into spin-longitudinal and spin-transverse components. From the comparison with the distorted wave impulse approximation calculations employing random phase approximation response functions, we found that our data showed the existence of the pionic and rho-mesonic correlations in nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A convolutional neural network approach to calibrating the rotation axis for X-ray computed tomography

This paper presents an algorithm to calibrate the center-of-rotation for X-ray tomography by using a machine learning approach, the Convolutional Neural Network (CNN). The algorithm shows excellent accuracy from the evaluation of synthetic data with various noise ratios. It is further validated with experimental data of four different shale samples measured at the Advanced Photon Source and at the Swiss Light Source. The results are as good as those determined by visual inspection and show better robustness than conventional methods. CNN has also great potential for reducing or removing other artifacts caused by instrument instability, detector non-linearity, etc . An open-source toolbox, which integrates the CNN methods described in this paper, is freely available through GitHub at tomography/xlearn and can be easily integrated into existing computational pipelines available at various synchrotron facilities. Source code, documentation and information on how to contribute are also provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging pion showers with the CALICE analogue hadron calorimeter

The CALICE collaboration investigates different technology options for highly granular calorimeters for detectors at a future electron-positron collider. One of the devices constructed and tested by the collaboration is a 1 m{sup 3} prototype for an imaging scintillator-steel sampling calorimeter for hadrons with analogue readout (AHCAL). The light from 7608 small scintillator cells is detected with silicon photomultipliers. The AHCAL has been successfully operated during electron and hadron test-beam measurements at DESY, CERN, and Fermilab since 2005. The collected data allow for evaluating the novel technologies employed. In addition, these data provide a valuable basis for validating pion cascade simulations. This paper presents the current status of comparisons between the AHCAL data and predictions from different Monte Carlo models implemented in GEANT4. The comparisons cover the total visible energy, longitudinal and radial shower profiles, and the shower substructure. Furthermore, this paper discusses a software compensation algorithm for improving the energy resolution of the AHCAL for single pions. (authors)

43 PARTICLE ACCELERATORS↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE

Analyses of cross section sensitivity data from systems with fissile material allow analysts to associate an importance for each material, nuclide, reaction, and neutron energy by simulating real world criticality scenarios. Although criticality safety validation efforts can be guided by the cross-section sensitivity and uncertainty data generated for a particular system, these calculations can often be computationally expensive and sometimes cumbersome without proper guidance. The TSUNAMI suite within the SCALE code package has several methods for generating sensitivity data, including multigroup and continuous energy (CE) capabilities. The release of SCALE 6.3 has three different CE methods for generating cross section sensitivity data: (1) the Iterated Fission Probability (IFP) method with the KENO Monte Carlo transport solver, (2) the IFP method with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method with the KENO Monte Carlo transport solver. Although the CLUTCH method has additional parameters for generating sensitivity data files relative to the IFP method, all three methods use latent generations, which are the generations between an event (i.e., fission) and the assessment of importance based on the asymptotic population of progeny neutrons. Increasing the number of latent generations in a calculation leads to increased discrimination of the sensitivity coefficients but at the cost of the increased uncertainty associated with those generated values. Analysts must balance the accuracy of the sensitivity calculations and its uncertainty with the associated computational cost involved in generating the values. This paper discusses the impact of adjusting the latent generation parameter for a range of sensitivity values and how these changes compare with the direct perturbation values obtained from a change of ±0.5% Δ k in both benchmark and safety application models. Two benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the MPC-32 dual purpose canister for spent nuclear fuel are used for analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PRISMATIC CORE COUPLED TRANSIENT BENCHMARK

The Prismatic Modular Reactor (PMR) is one of the High Temperature Reactor (HTR) design concepts that have existed for some time. Several prismatic units have operated in the world (DRAGON, Fort St. Vrain, Peach Bottom) and one unit is still in operation (HTTR). The deterministic neutronics and thermal-fluids transient analysis tools and methods currently available for the design and analysis of PMRs have lagged behind the state of the art compared to LWR reactor technologies. This has motivated the development of more accurate and efficient tools for the design and safety evaluations of the PMR. In addition to the work invested in new methods, it is essential to develop appropriate benchmarks to verify and validate the new methods in computer codes. The purpose of this benchmark is to establish a well-defined problem, based on a common given set of data, to compare methods and tools in core simulation and thermal hydraulics analysis with a specific focus on transient events. The benchmark-working group is currently seeking OECD/NEA sponsorship. This benchmark is being pursued and is heavily based on the success of the PBMR-400 exercise.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New Sensors for the Advanced Test Reactor National Scientific User Facility

A key component of the ATR NSUF effort is to develop and evaluate new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the selection strategy of what instrumentation is needed, and the program generated for developing new or enhanced sensors that can address these needs. Accomplishments from this program are illustrated by describing new sensors now available to users of the ATR NSUF with data from irradiation tests using these sensors. In addition, progress is reported on current research efforts to provide users advanced methods for detecting temperature, fuel thermal conductivity, and changes in sample geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expectation-propagation for weak radionuclide identification at radiation portal monitors

We propose a sparsity-promoting Bayesian algorithm capable of identifying radionuclide signatures from weak sources in the presence of a high radiation background. The proposed method is relevant to radiation identification for security applications. In such scenarios, the background typically consists of terrestrial, cosmic, and cosmogenic radiation that may cause false positive responses. We evaluate the new Bayesian approach using gamma-ray data and are able to identify weapons-grade plutonium, masked by naturally-occurring radioactive material (NORM), in a measurement time of a few seconds. We demonstrate this identification capability using organic scintillators (stilbene crystals and EJ-309 liquid scintillators), which do not provide direct, high-resolution, source spectroscopic information. Compared to the EJ-309 detector, the stilbene-based detector exhibits a lower identification error, on average, owing to its better energy resolution. Organic scintillators are used within radiation portal monitors to detect gamma rays emitted from conveyances crossing ports of entry. The described method is therefore applicable to radiation portal monitors deployed in the field and could improve their threat discrimination capability by minimizing “nuisance” alarms produced either by NORM-bearing materials found in shipped cargoes, such as ceramics and fertilizers, or radionuclides in recently treated nuclear medicine patients.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Automating Risk Assessments of Hazardous Material Shipments for Transportation Routes and Mode Selection

The METEOR project at Idaho National Laboratory (INL) successfully addresses the difficult problem in risk assessment analyses of combining the results from bounding deterministic simulation results with probabilistic (Monte Carlo) risk assessment techniques. This paper describes a software suite designed to perform sensitivity and cost/benefit analyses on selected transportation routes and vehicles to minimize risk associated with the shipment of hazardous materials. METEOR uses Monte Carlo techniques to estimate the probability of an accidental release of a hazardous substance along a proposed transportation route. A METEOR user selects the mode of transportation, origin and destination points, and charts the route using interactive graphics. Inputs to METEOR (many selections built in) include crash rates for the specific aircraft, soil/rock type and population densities over the proposed route, and bounding limits for potential accident types (velocity, temperature, etc.). New vehicle, materials, and location data are added when available. If the risk estimates are unacceptable, the risks associated with alternate transportation modes or routes can be quickly evaluated and compared. Systematic optimizing methods will provide the user with the route and vehicle selection identified with the lowest risk of hazardous material release. The effects of a selected range of potential accidents such as vehicle impact, fire, fuel explosions, excessive containment pressure, flooding, etc. are evaluated primarily using hydrocodes capable of accurately simulating the material response of critical containment components. Bounding conditions that represent credible accidents (i.e; for an impact event, velocity, orientations, and soil conditions) are used as input parameters to the hydrocode models yielding correlation functions relating accident parameters to component damage. The Monte Carlo algorithms use random number generators to make selections at the various decision points such as; crash, location, etc. For each pass through the routines, when a crash is randomly selected, crash parameters are then used to determine if failure has occurred using either external look up tables, correlations functions from deterministic calculations, or built in data libraries. The effectiveness of the software was recently demonstrated in safety analyses of the transportation of radioisotope systems for the US Dept. of Energy. These methods are readily adaptable to estimating risks associated with a variety of hazardous shipments such as spent nuclear fuel, explosives, and chemicals.

42 ENGINEERING↗

WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application. A high zresolution is preferred to stabilize statistical iterative reconstruction. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011), China Scholarship Council.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Time-Dependent Reactor and Sensor Physics on Core Power Synthesis (Rev.1)

Online synthesis of power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins and to provide essential knowledge associated with the burnup of the fuel. In light-water reactors, power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report examines the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a pressurized water reactor (PWR), considering the typical low-enriched uranium (LEU, 3%-5% enrichment) fuel cycle as well as the higher enrichment LEU+ (5%-8% enrichment) fuel cycle. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative PWR LEU core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used as well to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori power distribution assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters and the extended nature of the LEU+ fuel cycle in comparison with LEU. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly underapproximated or overapproximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumptions leads to severe levels of error, approaching 25% at maximum (for LEU). The authors also discovered that V SPNDs are extraordinarily robust in both the LEU and LEU+ fuel cycles considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Search for critical point indications in long-range correlations by energy and system size scanning in string fusion approach

The ultrarelativistic collisions of heavy and light ions in the center-of-mass energy range from a few up to a hundred GeV per nucleon have been considered in string fusion approach. A Monte Carlo model of proton-proton, proton-nucleus, and nucleus-nucleus collisions has been developed, which takes into account both the string fusion and the finite rapidity length of strings, implementing the hadronic scattering through the interaction of color dipoles. It well describes the proton-nucleus and nucleus-nucleus collisions at the partonic level without using Glauber model of nuclear collisions. All parameters are fixed using experimental data on inelastic cross section and multiplicity. In the framework of the model, we performed a beam energy and system size scan and studied the behaviour of n-n, pt-n and pt-pt long-range correlation coefficients. The detailed modeling of the event by event charged particles production allowed to provide predictions in the conditions close to the experimental ones allowing a direct comparison to the data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wireless energizing system for an automated implantable sensor

The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel chromenes and benzochromenes bearing arylazo moiety: molecular docking, in-silico admet, in-vitro antimicrobial and anticancer screening

Novel derivatives of benzochromene 9a–e and chromene 10a–e were synthesized via multi components reaction that utilizes azo dyes, malononitrile, and arylaldehydes as starting materials. The structures of the newly synthesized compounds were elucidated by the IR, {sup 1}H-NMR, {sup 13}C-NMR and mass spectral data. The new synthesized compounds were explored for their in-silico ADMET properties. The docking investigations verified good docking outcomes in terms of score and binding affinities of the examined compounds on the desired proteins, namely the GlcN-6-P synthase and PI3Ks. The in-vitro studies, which encompassed the antibacterial activity against two types of Gm +ve and two of Gm –ve, and the antifungal activity against four fungi micro-organisms were evaluated by the well diffusion method for the synthesized compounds. Moreover, the anticancer activity was tested against three human carcinoma cell lines [human colon carcinoma (HCT-116), human breast adenocarcinoma (MCF-7), and liver carcinoma (HEPG-2)], exhibiting promising anticancer activity in comparison to Vinblastine, Colchicine and Doxorubicin as standard drugs. The data suggests that some of the new derivatives of chromene scaffold which emerged promising in the in-silico molecular docking studies displayed good in-vitro antimicrobial and anticancer activities and could be exploited as leads for further optimization.

60 APPLIED LIFE SCIENCES↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AN ESTIMATE OF SPENT NUCLEAR FUEL MECHANICAL LOADS IN THE GENERAL 30 CM PACKAGE DROP SCENARIO

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transport to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. Researchers at Pacific Northwest National Laboratory (PNNL) have completed an extensive finite element study to characterize and estimate the potential mechanical loads on SNF during a hypothetical 30 cm drop of an SNF transportation package. This modeling study is validated with test data collected by the SFWST program during a physical test campaign that included one-third scale package drop tests and full-scale single fuel assembly drop tests. The test campaign was led by Sandia National Laboratories (SNL) and included international collaboration with Equipos Nucleares S.A, S.M.E (ENSA) and Bundesanstalt für Materialforschung und -prüfung (BAM). The key contribution of the modeling study is to go beyond the limitations of the limited number of physical tests to estimate the impact response to variations in impact angle, initial gap conditions, fuel assembly design, burnup and other parameters that affect the mechanical loads. The methodology of this study included a classic parametric study to calculate the impact response of highly detailed fuel assemblies over many combinations of parameters. Models of a 17x17 pressurized water reactor fuel assembly and a generic 10x10 boiling water reactor fuel assembly were both used in this study to cover the major fuel assembly types in the US inventory. Over 2,000 impact responses were calculated. The results of the parametric study were evaluated using traditional methods and basic statistics. The results were also used to construct a damage model using multiple nonlinear regression techniques to predict the mechanical loads over the full range of all input parameters. The damage model was found to work very well for all impact angle cases where the cask came to rest on its side. It was concluded that end drop cases where the cask remained vertical (instead of tipping over onto its side) were not sufficiently characterized by the current set of parametric study cases to include in the damage model, but it was not a priority to fully investigate that range because the highest mechanical loads were observed in the broader range of side impact cases. This modeling work provides sufficient insight into the mechanical loads on SNF during a hypothetical 30 cm package drop that, when considered along with the physical test data collected by the SNL-led team, the SFSWT program can consider the knowledge gap closed.

Klymyshyn, Nicholas A.↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗