Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORIFICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

The Origin of Carbon-bearing Volatiles in Surprise Valley Hot Springs in the Great Basin: Carbon Isotope and Water Chemistry Characterizations

There are numerous hydrothermal fields within the Great Basin of North America, some of which have been exploited for geothermal resources. With methane and other carbon-bearing compounds being observed, in some cases with high concentrations, however, their origins and formation conditions remain unknown. Thus, studying hydrothermal springs in this area provides us an opportunity to expand our knowledge of subsurface (bio)chemical processes that generate organic compounds in hydrothermal systems, and aid in future development and exploration of potential energy resources as well. While isotope measurement has long been used for recognition of their origins, there are several secondary processes that may generate variations in isotopic compositions: oxidation, re-equilibration of methane and other alkanes with CO2, mixing with compounds of other sources, etc. Therefore, in addition to isotopic analysis, other evidence, including water chemistry and rock compositions, are necessary to identify volatile compounds of different sources. Surprise Valley Hot Springs (SVHS, 41 deg 32'N, 120 deg 5'W), located in a typical basin and range province valley in northeastern California, is a terrestrial hydrothermal spring system of the Great Basin. Previous geophysical studies indicated the presence of clay-rich volcanic and sedimentary rocks of Tertiary age beneath the lava flows in late Tertiary and Quaternary. Water and gas samples were collected for a variety of chemical and isotope composition analyses, including in-situ pH, alkalinity, conductivity, oxidation reduction potential (ORP), major and trace elements, and C and H isotope measurements. Fluids issuing from SVHS can be classified as Na-(Cl)-SO4 type, with the major cation and anion being Na+ and SO4(2-), respectively. Thermodynamic calculation using ORP and major element data indicated that sulfate is the most dominant sulfur species, which is consistent with anion analysis results. Aquifer temperatures at depth estimated by both dissolved SiO2 and Na-K-Ca geothermometers are in the range of 125.0 to 135.4 C, and higher than the values measured at orifices (77.3 to 90.0 C). CO2 and homologs of straight chain alkanes (C1-C5) were identified in gas samples. Carbon isotope values of alkanes increase with carbon numbers. The C-13 fractionation between CO2 and dissolved inorganic carbon suggests they are out of carbon isotope equilibrium. The hypothesis regarding the formation of carbon-bearing compounds in SVHS may involve two processes: 1) Under high heat flow conditions which are caused by regional faulting and crustal extension, original high molecular weight organic compounds (kerogens) in clay-rich rocks decomposed to generate methane and other alkane homologs. 2) The SVHS area is associated with outflow structures, and distant from the heat source. Anaerobic oxidation of methane (AOM) with sulfate at shallow depth (< 90 C) is suggested as being responsible for the generation of CO2 in SVHS.

Fu, Qi↗

Combustion Stability Characteristics of the Project Morpheus Liquid Oxygen/Liquid Methane Main Engine

The Project Morpheus liquid oxygen (LOX) / liquid methane rocket engines demonstrated acousticcoupled combustion instabilities during sea‐level ground‐based testing at the NASA Johnson Space Center (JSC) and Stennis Space Center (SSC). High‐amplitude, 1T, 1R, 1T1R (and higher order) modes appear to be triggered by injector conditions. The instability occurred during the Morpheus‐specific engine ignition/start sequence, and did demonstrate the capability to propagate into mainstage. However, the instability was never observed to initiate during mainstage, even at low power levels. The Morpheus main engine is a JSC‐designed ~5,000 lbf‐thrust, 4:1 throttling, pressure‐fed cryogenic engine using an impinging element injector design. Two different engine designs, named HD4 and HD5, and two different builds of the HD4 engine all demonstrated similar instability characteristics. Through the analysis of more than 200 hot fire tests on the Morpheus vehicle and SSC test stand, a relationship between ignition stability and injector/chamber pressure was developed. The instability has the distinct characteristic of initiating at high relative injection pressure drop (dP) at low chamber pressure (Pc); i.e., instabilities initiated at high dP/Pc at low Pc during the start sequence. The high dP/Pc during start results during the injector /chamber chill‐in, and is enhanced by hydraulic flip in the injector orifice elements. Because of the fixed mixture ratio of the existing engine design (the main valves share a common actuator), it is not currently possible to determine if LOX or methane injector dP/Pc were individual contributors (i.e., LOX and methane dP/Pc typically trend in the same direction within a given test). The instability demonstrated initiation characteristic of starting at or shortly after methane injector chillin. Colder methane (e.g., sub‐cooled) at the injector inlet prior to engine start was much more likely to result in an instability. A secondary effect of LOX sub‐cooling was also possibly observed; greater LOX sub‐ cooling improved stability. Some tests demonstrated a low‐amplitude 1L‐1T instability prior to LOX injector chill‐in. The Morpheus main engine also demonstrated chug instabilities during some engine shutdown sequences on the flight vehicle and SSC test stand. The chug instability was also infrequently observed during the startup sequence. The chug instabilities predictably initiated at low dP/Pc at low Pc. The chug instabilities were always self‐limiting; startup chug instabilities terminated during throttle‐up and shutdown chug instabilities decayed by shutdown termination.

Melcher, J. C.↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system.An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (directionality).The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbmyr. to about 1 lbmday. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ramwake flows and structural shadowing within low Earth orbit.

Leak Locator↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

000000↗

High Current Hollow Cathode Plasma Plume Measurements

Plasma plume measurements are reported for a hollow cathode assembly (HCA) operated at discharge currents of 50, 70, and 100 A at xenon flow rates between 19 - 46 standard cubic centimeter per minute. The HCA was centrally mounted in the NASA-300MS Hall Thruster and was operated in the "spot" and "plume" modes with additional data taken with an applied magnetic field. Langmuir probes, retarding potential analyzers, and optical emission spectroscopy were employed to measure plasma properties near the orifice of the HCA and to assess the charge state of the near-field plasma. Electron temperatures (2-6 electron volt) and plasma potentials are consistent with probe-measured values in previous investigations. Operation with an applied-field yields higher discharge voltages, increased Xe III production, and increased signals from the 833.5 nm C I line. While operating in plume mode and with an applied field, ion energy distribution measurements yield ions with energies significantly exceeding the applied discharge voltage. These findings are correlated with high-frequency oscillations associated with each mode.

High frequency analysis↗

Numerical Simulations of the Partially-Ionized Gas in a 100-A LaB6 Hollow Cathode

Numerical simulations of a hollow cathode with a LaB6 emitter operating at 100 A have been performed for the first time using the 2-D Orificed Cathode (OrCa2D) code. Results for a variety of plasma properties are presented and compared with laboratory measurements. The large size of the device permits peak electron number densities in the cathode interior that are lower than those established in the NSTAR hollow cathode, which operates with a 7.3x lower discharge current and 3.2x lower mass flow rate. Also, despite the higher discharge current in the LaB6 cathode, the maximum electron current density is lower, by 4.2x, than that in the NSTAR cathode due to the larger orifice size. Simulations and direct measurements show that at 12 sccm of xenon flow the peak emitter temperature is in the range of 1594-1630 C. It is also found that the conditions for the excitement of current-driven streaming instabilities and ion-acoustic turbulence (IAT) are satisfied in this cathode, similarly to what was found in the past in its smaller counterparts like the NSTAR cathode. Based on numerical simulations, it has long been argued that these instabilities may be responsible for the anomalously large ion energies that have been measured in these discharges as well as for the enhancement of the plasma resistivity. Confirmation of the presence of IAT in this cathode is presented for the first time in a companion paper.

robotic exploration↗

Development and Testing of High Current Hollow Cathodes for High Power Hall Thrusters

NASA's Office of the Chief Technologist In-Space Propulsion project is sponsoring the testing and development of high power Hall thrusters for implementation in NASA missions. As part of the project, NASA Glenn Research Center is developing and testing new high current hollow cathode assemblies that can meet and exceed the required discharge current and life-time requirements of high power Hall thrusters. This paper presents test results of three high current hollow cathode configurations. Test results indicated that two novel emitter configurations were able to attain lower peak emitter temperatures compared to state-of-the-art emitter configurations. One hollow cathode configuration attained a cathode orifice plate tip temperature of 1132 degC at a discharge current of 100 A. More specifically, test and analysis results indicated that a novel emitter configuration had minimal temperature gradient along its length. Future work will include cathode wear tests, and internal emitter temperature and plasma properties measurements along with detailed physics based modeling.

Kamhawi, Hani↗

Neutralizer Hollow Cathode Simulations and Validation with Experiments

The fidelity of electric propulsion physics-based models depends largely on the validity of their predictions over a range of operating conditions and geometries. In general, increased complexity of the physics requires more extensive comparisons with laboratory data to identify the region(s) that lie outside the validity of the model assumptions and to quantify the uncertainties within its range of application. This paper presents numerical simulations of neutralizer hollow cathodes at various operating conditions and orifice sizes. The simulations were performed using a two-dimensional axisymmetric model that solves numerically a relatively extensive system of conservation laws for the partially-ionized gas in these devices. The results for the plasma are compared directly with Langmuir probe measurements. The computed keeper voltages are also compared with the observed values. Wherever model inputs and/or specific physics of the cathode discharge are uncertain, additional sensitivity calculations have been performed to quantify the uncertainties.

partially ionized gases↗

Highly Inclined Jets in Cross Flow

Results from an experimental investigation of flow field generated by pitched and yawed jets discharging from a flat plate into a cross-flow are presented. The circular jet was pitched at alpha = 20deg and 45deg and yawed between Beta = 0deg and 90deg in increments of 15deg. The measurements were performed with two ×-wires providing all three components of velocity and turbulent stresses. These data were obtained at downstream locations of x = 3, 5, 10 and 20, where the distance x, normalized by the jet diameter, is measured from the center of the orifice. Data for all configurations were acquired at a momentum-flux ratio J = 8. Additionally, for selected angles and locations, surveys were conducted for J = 1.5, 4, and 20. As expected, the jet penetration is found to be higher at larger alpha. With increasing beta the jet spreads more. The rate of reduction of peak streamwise vorticity, ω max, with the downstream distance is significantly less at higher Beta but is found to be practically independent of alpha. Thus, at the farthest measurement station x = 20, ωxmax is about five times larger for Beta = 75deg compared to the levels at Beta = 0deg. Streamwise velocity within the jet-vortex structure is found to depend on the parameter J. At J = 1.5 and 4, 'wake-like' velocity profiles are observed. In comparison, a 'jet-like' overshoot is present at higher J. Distributions of turbulent stresses for various cases are documented. Peak normal stresses are found to occur within the core of the streamwise vortices. With yaw, at lower values of J, high turbulence is also observed in the boundary layer underneath the jet-vortex structure

Milanovic, I. M.↗

Chug and Dynamics of the RS-84 Subscale Preburner

The development of the RS-84 engine began in 2002 as part of the Space Launch Initiative. It was intended to be a reusable liquid oxygen/RP-1 booster engine of approximately 1 Mlbf thrust. Part of the test campaign consisted of testing subscale components to study key technologies such as oxygenrich, liquid oxygen/RP-1 combustion. In late 2003, the subscale preburner completed 4 hot-fire tests at Stennis Space Center with various hardware configurations and operating conditions, but before all planned tests could be completed the RS-84 engine development program was canceled in 2004. Recently, there has been a renewed interest in the development of an oxygen-rich, liquid oxygen/RP-1 combustion engine. Aerojet Rocketdyne and NASA completed testing of the subscale preburner in 2014 at Marshall Space Flight Center in an effort to better understand the chug encountered during the 2003 testing and to collect performance information over a wider range of operating conditions. The 2003 and 2014 data sets included extreme chug oscillations that reached nearly 200% of the chamber pressure and were reduced to well below 10% of the chamber pressure by incorporating a fuel orifice upstream of the fuel manifold. Depending on the hardware configuration and operating condition, a wide range of chug oscillation amplitudes were encountered. The dynamics for both test series were characterized and the data were used in the development of a chug model.

Casiano, M. J↗

Kinetics of Hydrogen Oxidation Downstream of Lean Propane and Hydrogen Flames

The decay of hydrogen was measured downstream of lean, flat, premixed hydrogen and propane-air flames seated on cooled porous burners. Experimental variables included temperature, pressure, initial equivalence ratio and diluent. Sampling of burned gas was done through uncooled quartz orifice probes, and the analysis was based on gas chromatography. An approximate treatment of the data in which diffusion was neglected led to the following rate expression for the zone downstream of hydrogen flames d[H (sub 2)] divided by (d times t) equals 1.7 times 10 (sup 10) [H (sub 2)] (sup 3) divided by (sub 2) [O (sub 2)]e (sup (-8100 divided by RT)) moles per liters per second. On the basis of a rate expression of this form, the specific rate constant for the reaction downstream of hydrogen flames was about three times as great as that determined downstream of propane flames. This result was explained on the basis of the existence of a steady state between hydrogen and carbon monoxide in the burned gas downstream of propane flames.

Fine, Burton↗

Spreadsheet Calculation of Jets in Crossflow: Opposed Rows of Slots Slanted at 45 Degrees

The purpose of this study was to extend a baseline empirical model to the case of jets entering the mainstream flow from opposed rows of 45 degrees slanted slots. The results in this report were obtained using a spreadsheet modified from the one posted with NASA/TM--2010-216100. The primary conclusion in this report is that the best mixing configuration for opposed rows of 45 degrees slanted slots at any down stream distance is a parallel staggered configuration where the slots are angled in the same direction on top and bottom walls and one side is shifted by half the orifice spacing. Although distributions from perpendicular slanted slots are similar to those from parallel staggered configurations at some downstream locations, results for perpendicular slots are highly dependent on downstream distance and are no better than parallel staggered slots at locations where they are similar and are worse than parallel ones at other distances.

Holderman, James D.↗

The Theory of Pulsating Flow in Conical Nozzles

A knowledge of the dynamic characteristics of nozzles and orifices is important in many control and stability analyses of engineering devices. It is usual to assume that the instantaneous flow-rate, for a given set of inlet conditions and outlet pressure, is the same as the nontransient value for the same operating conditions. Recently, in connection with the stability analysis of an externally pressurized thrust bearing, the validity of this assumption was questioned. The analysis presented in this paper was undertaken to provide an answer. The present analysis applies to any fluid, liquid, or gas flowing into a simple conical nozzle. The amplitude and phase of the mass-flux response to a sinusoidally time-varying pressure fluctuation at the nozzle exit are determined. An approximate formula is given for these quantities in terms of the nozzle throat area, the solid angle subtended by the cone, the velocity of the fluid at the nozzle throat, the acoustic velocity at the throat, and the frequency of the pressure fluctuation.

Elrod, H. G., Jr.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Viscous Effects on Impact Probes in a Subsonic Rarified Gas Flow

The problem of time response of pressure gaging systems used with low density flows has been discussed in Ref ]4, and the effect of outgassing on pressure magnitudes was indicated in the same reference. Briefly, gases or vapors adhering to the internal walls of the pressure gaging system behave like gas sources and produce a pressure rise in the gage system which has no relation to the external flow. The effect can also occur in the reverse direction, with "in-gassing" or the action of an effective sink in the gage system as gases entering through the probe orifice are adsorbed to the walls. For given surface conditions, the magnitude of the pressure error to be expected due to out-gassing depends on the dimensions of the probe system. In the present tests, it was desirable to use the smallest possible probe to yield the lowest possible Reynolds number. The lower limit on size was fixed by outgassing effects, evaluated by the following procedure. 2.0 PROCEDURE The pumping system was adjusted to give a pressure, measured at the reservoir, of 9 microns Hg with no flow into the wind tunnel. The upstream metering valve was then opened and the air flow rate adjusted to give a pressure of 100 microns in the reservoir under steady flow conditions, The pressure read by one of the impact tubes, inserted into the flow, was measured. The upstream metering valve was then closed rapid)y, and the reservoir pressure, p0, and the impact probe pressure, Pj, were measured simultaneously at definite time intervals. Another probe was inserted into the flow and the procedure repeated, until the pressure-time data had been obtained for each probe investigated. The results for a series of tests Involving probe Nos.l, 2 and 3 are shown on HYD 2616 300 RESULTS From HYD 2616, It is clear that the smallest probe (No.3) requires the longest time to reach equilibrium. After a sufficient time has elapsed (about 180 seconds), this probe read the same, within the accuracy of measurement, as the other two, When a similar experiment was performed utilizing a probe which was one-half the size of probe No.2, it indicated a pressure, after 180 seconds, which was almost 10 microns Hg higher than the other probes. Accordingly, only probe Nos. 1, 2, 3 and 4 were employed in the experiments, and a time of at least 180 seconds was allowed to elapse between a change of setting and the reading of the instruments0

Kane, E. D.↗

Simplified Methodology to Estimate the Maximum Liquid Helium (LHe) Cryostat Pressure from a Vacuum Jacket Failure

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared astronomical observation experiments. These experiments carry sensors cooled to liquid helium temperatures. The liquid helium supply is contained in large (i.e., 10 liters or more) vacuum-insulated dewars. Should the dewar vacuum insulation fail, the inrushing air will condense and freeze on the dewar wall, resulting in a large heat flux on the dewar's contents. The heat flux results in a rise in pressure and the actuation of the dewar pressure relief system. A previous NASA Engineering and Safety Center (NESC) assessment provided recommendations for the wall heat flux that would be expected from a loss of vacuum and detailed an appropriate method to use in calculating the maximum pressure that would occur in a loss of vacuum event. This method involved building a detailed supercritical helium compressible flow thermal/fluid model of the vent stack and exercising the model over the appropriate range of parameters. The experimenters designing science instruments for SOFIA are not experts in compressible supercritical flows and do not generally have access to the thermal/fluid modeling packages that are required to build detailed models of the vent stacks. Therefore, the SOFIA Program engaged the NESC to develop a simplified methodology to estimate the maximum pressure in a liquid helium dewar after the loss of vacuum insulation. The method would allow the university-based science instrument development teams to conservatively determine the cryostat's vent neck sizing during preliminary design of new SOFIA Science Instruments. This report details the development of the simplified method, the method itself, and the limits of its applicability. The simplified methodology provides an estimate of the dewar pressure after a loss of vacuum insulation that can be used for the initial design of the liquid helium dewar vent stacks. However, since it is not an exact tool, final verification of the dewar pressure vessel design requires a complete, detailed real fluid compressible flow model of the vent stack. The wall heat flux resulting from a loss of vacuum insulation increases the dewar pressure, which actuates the pressure relief mechanism and results in high-speed flow through the dewar vent stack. At high pressures, the flow can be choked at the vent stack inlet, at the exit, or at an intermediate transition or restriction. During previous SOFIA analyses, it was observed that there was generally a readily identifiable section of the vent stack that would limit the flow – e.g., a small diameter entrance or an orifice. It was also found that when the supercritical helium was approximated as an ideal gas at the dewar condition, the calculated mass flow rate based on choking at the limiting entrance or transition was less than the mass flow rate calculated using the detailed real fluid model2. Using this lower mass flow rate would yield a conservative prediction of the dewar’s wall heat flux capability. The simplified method of the current work was developed by building on this observation.

Ungar, Eugene K.↗

Characterization of a Regenerable Impactor Filter for Spacecraft Cabin Applications

Regenerable filters will play an important role in human exploration beyond low-Earth orbit. Life Support Systems aboard crewed spacecrafts will have to operate reliably and with little maintenance over periods of more than a year, even multiple years. Air filters are a key component of spacecraft life support systems, but they often require frequent routine maintenance. Bacterial filters aboard the International Space Station require almost weekly cleaning of the pre-filter screen to remove large lint debris captured in the microgravity environment. The source of the airborne matter which is collected on the filter screen is typically from clothing fibers, biological matter (hair, skin, nails, etc.) and material wear. Clearly a need for low maintenance filters requiring little to no crew intervention will be vital to the success of the mission. An impactor filter is being developed and tested to address this need. This filter captures large particle matter through inertial separation and impaction methods on collection surfaces, which can be automatically cleaned after they become heavily loaded. The impactor filter can serve as a pre-filter to augment the life of higher efficiency filters that capture fine and ultrafine particles. A prototype of the filter is being tested at the Particulate Filtration Laboratory at NASA Glenn Research Center to determine performance characteristics, including particle cut size and overall efficiency. Model results are presented for the flow characteristics near the orifice plate through which the particle-laden flow is accelerated as well as around the collection bands.

air filters↗