Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Two years of on-orbit gallium arsenide performance from the LIPS solar cell panel experiment

The LIPS on-orbit performance of the gallium arsenide panel experiment was analyzed from flight operation telemetry data. Algorithms were developed to calculate the daily maximum power and associated solar array parameters by two independent methods. The first technique utilizes a least mean square polynomial fit to the power curve obtained with intensity and temperature corrected currents and voltages; whereas, the second incorporates an empirical expression for fill factor based on an open circuit voltage and the calculated series resistance. Maximum power, fill factor, open circuit voltage, short circuit current and series resistance of the solar cell array are examined as a function of flight time. Trends are analyzed with respect to possible mechanisms which may affect successive periods of output power during 2 years of flight operation. Degradation factors responsible for the on-orbit performance characteristics of gallium arsenide are discussed in relation to the calculated solar cell parameters. Performance trends and the potential degradation mechanisms are correlated with existing laboratory and flight data on both gallium arsenide and silicon solar cells for similar environments.

Francis, R. W.↗

Laser power stations in orbit.

Potential laser applications for space-borne power generation are discussed in the light of the current state of the art. The feasible ranges of various laser classes with standing waves are estimated. Power and efficiency, mirror factors, phased-array performance and beam patterns are analyzed as selection characteristics. Other topics include the maximum receiving-element size, energy conversion, pointing and tracking, causes of deformation, and mirror distortions. It is theorized that a nuclear-fueled laser satellite could beam power to distances twice the earth-sun distance with predictable pointing accuracies.

Hansen, C. F.↗

High-Burnup BWR LOCA Burst Analysis Using High-Fidelity Multiphysics Simulations

The US nuclear industry is looking to improve on the operating economics of the current fleet of light-water reactors (LWRs). One way of achieving this is by operating fuel to higher burnup. In pressurized water reactors (PWRs), relaxing the current burnup limit will allow for cycle length extensions and power uprates; in boiling water reactors (BWRs) it may allow for improved fuel utilization and reduced feed assemblies, as well as more efficient power uprates and increased capacity factors that will support the Administration’s Executive Order to facilitate 5 GW of power uprates at existing nuclear facilities. However, one of the key limitations to operating fuel to higher burnup is the risk of fuel fragmentation, relocation, and dispersal (FFRD). Recognizing the high interest in extending burnup limits, the US Nuclear Regulatory Commission (NRC) has issued Draft Regulatory Guide DG-1434, which defines an approach that would be acceptable to the NRC for addressing FFRD risk. The approach defined will require better understanding of the phenomena leading to FFRD as well as best-estimate simulation methods to understand FFRD risk in high-burnup cores. The Nuclear Energy Advanced Modeling and Simulation program is supporting the FFRD industry challenge problem through development of state-of-the-art, high-fidelity modeling and simulation LWR analysis capabilities; namely, the BISON fuel performance code and the VERA core simulator software. These tools, along with the US NRC TRACE system analysis code, have been utilized for analysis of FFRD risk in both PWR and BWR cores in recent years. The work documented in this report addresses the lack of high-fidelity research for BWRs and builds on a previous activity where the framework has been applied to Cycles 16 through 18 of Limerick Unit 1, a BWR/4, with introduction of 8 high-burnup lead use assemblies (HBLUAs) that were representative of the 8 HBLUAs loaded into Limerick Unit 2 in 2021. VERA was used in this previous activity to model rod-by-rod depletion in these cycles, and its solution was used to initialize a TRACE simulation of a large-break loss-of-coolant accident (LBLOCA) at the end of Cycle 18. In the work documented in this report, the TRACE model was improved by refining the core mesh and utilizing a new feature that allows for capturing the full 3D VERA power distribution in the model. This allows for a more detailed solution for setting BISON boundary conditions. Furthermore, the solutions from VERA and TRACE were used to set up and perform BISON simulations of about 1,000 rods sampled from the core, including all burnup levels. Utilizing two cladding burst models, it was shown that no fuel rods were predicted to burst during the postulated LBLOCA transient. Additionally, a sensitivity study was performed by artificially increasing linear heat rate during the postulated LBLOCA to identify parameters that correlate with rod burst susceptibility. Burnup, fission gas release, and hoop strain were all found to be positively correlated with rod burst susceptibility. Small-break loss-of-coolant accident (SBLOCA) analyses were also performed; these analyses predicted cladding temperature increases that were bounded by the LBLOCA cladding temperatures for all small break sizes studied for this plant. However, future refinements to the plant response assumptions during the SBLOCA could impact the predicted cladding response. Finally, a benchmark study was performed between CTF and TRACE for LOCA conditions to better qualify CTF for BWR LOCA modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Estimation of SNF amount from various scenarios of power consumption prediction in South Korea - 15394

The Korean government is reviewing the methodology for every condition such as treatment, storage, disposal for the management of spent fuel. In order to establish the control policy of spent fuel, it is necessary to predict how much spent fuel is produced as the time changes. In this thesis the spent fuel production amount was predicted with the basis of the forecast number of the nuclear power plant. Until 2024 the construction plan was applied and until 2035 the number was predicted considering the ratio of nuclear power production. From 2035 to 2100, long term assessment was done assuming the energy consumption in different cases to calculate the necessary power production and then the amount was applied to the of the current power plant production rate to calculate the power production amount by nuclear power plant and the number of necessary nuclear power plants. As the estimated number of the operated power plants of each year and period is correlated with the nuclear power production amount, the main factors of the assessment were spent fuel production amount, the number of operated nuclear power plant, power consumption amount, power production amount, and the proportion of the nuclear power plant to assess. In long-term view the spent fuel production amount differed highly depending on the different conditions so it's thought to be necessary to establish policies after predicting the spent fuel production amount by every case for the management plan of spent fuel. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Thermal excursion can cause bond problems.

The purpose of this paper is to illustrate the failure mode caused by thermal deformation and how thermal deformation affects bond integrity. Wege bonding in small-signal transistors, microcircuits and LSI circuits is the subject of this work. Repeated switching of the devices between high and low power at a rate that allows thermal expansion and contraction in the interconnecting wire causes the wire to flex at the point of reduced cross-sectional area until finally the wire breaks due to metal fatigue. It was observed that the thermal deformation was related to many factors such as device power dissipation, current density in the wire, wi *e dress and length, thermal time constant and frequency of operation.

Nowakowski, M. F.↗

MOCUM: A two-dimensional method of characteristics code based on unstructured meshing for general geometries

A transport theory code MOCUM based on the Method of Characteristics (MOC) as the flux solver with an advanced general geometry processor is developed for two-dimensional lattice and full core neutronics modeling. The core structure is represented by Constructive Solid Geometry (CSG) that uses Boolean operations to build complex geometries from simple polygons. Arbitrary-precision arithmetic is also used in the process of building CSG objects to eliminate the round-off error from the commonly used double precision numbers. Then, the constructed core frame will be decomposed and refined into a conforming Delaunay triangulation to ensure the quality of the meshes. The MOC solver kernel is fully paralleled using OpenMP and the developed numerical code is validated by several benchmarks representing various core geometries. For the cases modeled, the maximum percentage error for multiplication factor and the pin power compared to reference values are 0.1% and 0.7% respectively. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of drought on U.S. steam electric power plant cooling water intakes and related water resource management issues.

This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements their overall research effort by evaluating water availability at power plants under drought conditions. While there are a number of competing demands on water uses, particularly during drought conditions, this report focuses solely on impacts to the U.S. steam electric power plant fleet. Included are both fossil-fuel and nuclear power plants. One plant examined also uses biomass as a fuel. The purpose of this project is to estimate the impact on generation capacity of a drop in water level at U.S. steam electric power plants due to climatic or other conditions. While, as indicated above, the temperature of the water can impact decisions to halt or curtail power plant operations, this report specifically examines impacts as a result of a drop in water levels below power plant submerged cooling water intakes. Impacts due to the combined effects of excessive temperatures of the returned cooling water and elevated temperatures of receiving waters (due to high ambient temperatures associated with drought) may be examined in a subsequent study. For this study, the sources of cooling water used by the U.S. steam electric power plant fleet were examined. This effort entailed development of a database of power plants and cooling water intake locations and depths for those plants that use surface water as a source of cooling water. Development of the database and its general characteristics are described in Chapter 2 of this report. Examination of the database gives an indication of how low water levels can drop before cooling water intakes cease to function. Water level drops are evaluated against a number of different power plant characteristics, such as the nature of the water source (river vs. lake or reservoir) and type of plant (nuclear vs. fossil fuel). This is accomplished in Chapter 3. In Chapter 4, the nature of any compacts or agreements that give priority to users (i.e., which users must stop withdrawing water first) is examined. This is examined on a regional or watershed basis, specifically for western water rights, and also as a function of federal and state water management programs. Chapter 5 presents the findings and conclusions of this study. In addition to the above, a related intent of this study is to conduct preliminary modeling of how lowered surface water levels could affect generating capacity and other factors at different regional power plants. If utility managers are forced to take some units out of service or reduce plant outputs, the fuel mix at the remaining plants and the resulting carbon dioxide emissions may change. Electricity costs and other factors may also be impacted. Argonne has conducted some modeling based on the information presented in the database described in Chapter 2 of this report. A separate report of the modeling effort has been prepared (Poch et al. 2009). In addition to the U.S. steam electric power plant fleet, this modeling also includes an evaluation of power production of hydroelectric facilities. The focus of this modeling is on those power plants located in the western United States.

09 BIOMASS FUELS↗

Performance Testing of an Integrated Magnetic Power Take-Off

A wave energy converter (WEC) and the power take-off (PTO) generator system can be represented by using a mass-spring-dampener model. By incorporating a negative stiffness spring within the PTO, the overall stiffness of the PTO can be lowered allowing the impedance of the PTO to be more closely matched with the WEC. By designing for impedance matching the WEC can greatly enhance its power generation capability. This project has involved the design, fabrication and testing of a new type of linear-stroke length and rotary stroke length adjustable negative stiffness magnetic springs for use within a wave energy converter (WEC). The magnetic springs were studied by using 3-D finite element analysis with the objective of creating high energy density and a long linear stroke length. After the construction and testing of both a proof-of-principle adjustable linear and rotary magnetic spring prototype the rotary (torsional) magnetic spring was selected for scaling up analysis. The selected scaled-up proof-of-principle magnetic spring had a peak torque of 850 Nm with a ±45 degree stroke length. By translating the inner rotor relative to the outer rotor, the stiffness could be adjusted to be either negative or positive stiffness. During this project a magnetic lead screw was also studied, and it was shown that by combining the magnetic lead screw with a linearly translating magnetic spring a very long rotary stroke length could be attained. However, as the magnetic lead screw increased complexity and reduced overall energy density relative to a rotary (torsional) spring, this design approach was not further pursed. Dynamometer testing of the variable stiffness magnetic springs was first completed by Portland State University and following this the magnetic spring performance was independently verified by Sandia National Laboratory (Sandia). A WEC analysis when using a variable stiffness magnetic spring was completed by using the WecOptTool. WecOptTool is an open-source WEC optimization software developed by Sandia that supports efficient power take-off (PTO) and control optimization. Wave condition data from the Oregon PacWave test-site was used in this study. The analysis showed that a WEC with a tunable stiffness value could consistently achieve about 80% of its maximum theoretical power production. The use of a tunable stiffness WEC, rather than zero-stiffness or a constant stiffness WEC was also shown to lead to a smaller maximum PTO force requirement. The variable stiffness magnetic spring was integrated into an experimental WEC developed by Sandia, called a Wave-Bot. Sandia successfully completed water-tank testing of the Wave-Bot at the Navy’s Carderock, Maryland, wave-basin test site. The wave-basin testing helped to experimentally demonstrate the operating capabilities and increased power generation capability of a WEC containing an integrated variable stiffness magnetic spring. A WEC capacity factor analysis was also completed. The capacity factor was defined as the ratio of annual average WEC generator power to the maximum (RMS) generated power. This capacity factor provided a means of identifying the ratio of potential revenue to cost. It was calculated that if a tunable variable stiffness magnetic spring has RMS constraints it could operate with a capacity factor above 30%. This is comparable to a wind turbine’s capacity factor.

16 TIDAL AND WAVE POWER↗

Transition Core Modeling for Extended Enrichment & Accident-Tolerant Fuels Using Polaris/PARCS

Commercial light water reactor (LWR) operators and fuel vendors are currently interested in increasing the low-enriched uranium (LEU) fuel enrichments from the current limit of 5.0 $^w/_o$ $^{235}U$ up to 10 $^ w/_o$ $^{235}U$ (referred to as "LEU+") in their current fleets; they are also interested in using accident-tolerant fuel (ATF) with both LEU and LEU+ fuel. This report aims to identify modeling challenges and accuracy concerns in transition core analysis using the SCALE Polaris lattice physics code and U.S. Nuclear Regulatory Commission core simulator PARCS. At the time this study was started, no publicly available LEU+ core designs existed for boiling water reactor (BWR) or pressurized water reactor (PWR) systems. Therefore, fuel lattices were shuffled within a multi-assembly model to mimic neutronically challenging lattice combinations seen in transition cores, such as a fresh LEU+ lattice next to depleted LEU lattices. In addition to multi-assembly models, whole-core BWR transition core calculations were performed for ATF and LEU+ fuel using an existing Hatch-1 Cycle 3 core model. A whole-core BWR model was chosen due to the more heterogeneous core designs compared to those for a PWR core. Since the original core is an old checkerboard core design and no core or fuel design optimization was performed for the modeled fuel types, these core calculations were intended only to provide: (1) Comparisons of core characteristics of interest, such as the pin power distributions and peaking factors, Doppler temperature coefficients (DTCs), and control blade worths (CBWs) under challenging core designs, (2) Identification of reactor physics challenges in modeling LEU+ and ATF cores, and (3) A stress test for the Polaris/PARCS two-step modeling approach, including characterization of the relative accuracy for predicting characteristics of interest such as pin power distributions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High temperature, high intensity solar array

The solar array for the Venus Radar Mapper mission will operate in the high temperature, high intensity conditions of a low Venus orbit environment. To fulfill the performance requirements in this environment at minimum cost and mass while maximizing power density and packing factor on the panel surface, several features were introduced into the design. These features included the use of optical surface reflectors (OSR's) to reduce the operating temperature; new adhesives for conductive bonding of OSR's to avoid electrostatic discharges; custom-designed large area cells and novel shunt diode circuit and panel power harness configurations.

Smith, B. S.↗

High Efficiency 2-Bladed Utility Wind Turbine Enhanced by CoFlow Jet Active Flow Control

The aerodynamic performance and power output of a high efficiency Co-Flow Jet (CFJ) 2-bladed Wind Turbine is studied in this paper. CFJ is a Zero-Net-Mass-Flux (ZNMF) active flow control method that dramatically increases airfoil lift coefficient and suppresses flow separation at a low energy expenditure. The 3D Reynolds Averaged Navier-Stokes (RANS) equations with one-equation Spalart-Allmaras (SA) turbulence model are solved to simulate the 3D flows of the wind turbines. The CFJ-Wind Turbine in this paper is modified from the NREL 3-bladed 3.4 MW reference wind turbine with the same RPM, blade length, distribution of chord, twist, and bending. The CFJ 2-bladed wind turbine utilizes the CFJ-NACA 64 series airfoils at most of the blade span from 31.88\% to the tip. The CFJ injection and suction slots are implemented along the full blade span to enhance the effectiveness and power output. The study shows that the 2-bladed CFJ turbine significantly increases power output compared with the 3-bladed baseline turbine at all wind speeds by 15.8\% at the wind speed of 9.8 m/s and by 25.9\% at 4 m/s respectively. The efficiency enhancement is substantially more at the low wind speed than at high wind speed. This would be very beneficial to increase the annual power output or capacity factor as wind turbines work at the speeds lower than the rated speed for most of the time. The results show that the flow field around the blade surface presents a significant enhanced suction peak near the blade leading edge, which results in a very high tangential force and thus increased wind turbine net power coefficient. Consistent with the previous study for the small NREL Phase VI research wind turbine, this paper demonstrates that CFJ 2-bladed wind turbine is an effective technology to extract more power from the wind at all speeds. This study is just an initial effort to demonstrate the advantage of the CFJ blade with no design optimization. It is believed that there is more potential to further enhance the efficiency improvement.

active flow control↗

Effect of self-generated magnetic fields on x-ray emission in Kr-filled targets at the National Ignition Facility

We examine the effects of self-generated magnetic fields in a Kr gas pipe x-ray source platform. X-ray emission from Kr plasma is dependent on the plasma conditions, as the ionization state is largely a function of temperature. Magnetic fields are known to limit heat conduction, which increases temperature. We show that the emission in simulations of the gas pipe x-ray source is dependent on how self-generated magnetic fields are modeled. The inclusion of self-generated magnetic fields in simulations more accurately captures the emission of lower energy x-ray emission (L-shell), bringing results closer to experiments. The modeled x-ray emission and self-generated magnetic fields are shown to be particularly sensitive to the inclusion of the Nernst effect in simulations. Severely limiting the Nernst effect leads to a hotter Kr plasma, which can account for the discrepancy seen in earlier studies. By modifying the Nernst effect multiplier, we can achieve better experimental agreement in x-ray emission from gas pipes; the value of the multiplier that leads to the best agreement is dependent on the laser power of the drive. Currently, the suppression factor of the Nernst effect needed for high power drives (PL>200 TW) is more restrictive than what is currently put forward by non-local models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The spectral energy distribution of NGC 1275

An analysis of absolute spectral energy distributions for NGC 1275 (Per A) covering the wavelength interval from 3300 A to 10,800 A is presented. The data are consistent with the heavy reddening discovered by Wampler (1971). The H-alpha intensity varied by less than 10% between the times of Wampler's earlier measurements and the two occasions of the present observations. The line-emitting region has a characteristic density of about 10 to the 4.5 power per cu cm, a mass of about 10 to the 5.5 power solar masses, and a volume filling factor of about 10 to the -6th power. The gas may be ionized by shock waves or by nonthermal or stellar radiation. It is suggested, in the vein of Minkowski's (1957) original proposal, that the high-velocity emission-line knots described by Minkowski are H II regions in a Perseus-cluster galaxy or intergalactic gas cloud seen in projection against NGC 1275.

Shields, G. A.↗

Investigation of lower hybrid wave coupling and current drive experiments at different configurations in experimental advanced superconducting tokamak

Using a 2 MW 2.45 GHz lower hybrid wave (LHW) system installed in experimental advanced superconducting tokamak, we have systematically carried out LHW-plasma coupling and lower hybrid current drive experiments in both divertor (double null and lower single null) and limiter plasma configuration with plasma current (I{sub p}) {approx} 250 kA and central line averaged density (n{sub e}) {approx} 1.0-1.3 x 10{sup 19} m{sup -3} recently. Results show that the reflection coefficient (RC) first is flat up to some distance between plasma and LHW grill, and then increases with the distance. Studies indicate that with the same plasma parameters, the best coupling is obtained in the limiter case (with plasma leaning on the inner wall), followed by the lower single null, and the one with the worst coupling is the double null configuration, explained by different magnetic connection length. The RCs in the different poloidal rows show that they have different coupling characteristics, possibly due to local magnetic connection length. Current drive efficiency has been investigated by a least squares fit with N{sub //}{sup peak}=2.1, where N{sub //}{sup peak} is the peak value of parallel refractive index of the launched wave. Results show that there is no obvious difference in the current drive efficiency between double null and lower single null cases, whereas the efficiency is somewhat small in the limiter configuration. This is in agreement with the ray tracing/Fokker-Planck code simulation by LUKE/C3PO and can be interpreted by the power spectrum up-shift factor in different plasma configurations. A transformer recharge is realized with {approx}0.8 MW LHW power and the energy conversion efficiency from LHW to poloidal field energy is about 2%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on Inflationary Gravitational Waves with Two Years of SPT-3G Data

We present a measurement of the $B$-mode polarization power spectrum of the cosmic microwave background anisotropies at 32 $\le$$\ell$$<$ 502 for three bands centered at 95, 150, and 220 GHz using data from the SPT-3G receiver on the South Pole Telescope. This work uses SPT-3G observations from the 2019 and 2020 winter observing seasons of a $\sim$1500 deg$^2$ patch of sky that directly overlaps with fields observed with the BICEP/Keck family of telescopes, and covers part of the proposed Simons Observatory and CMB-S4 deep fields. Employing new techniques for mitigating polarized atmospheric noise, the SPT-3G data demonstrates a white noise level of 9.3 (6.7) $\mu$K-arcmin at $\ell \sim 500$ for the 95 GHz (150 GHz) data, with a $1/\ell$ noise knee at $\ell$=128 (182). We fit the observed six auto- and cross-frequency $B$-mode power spectra to a model including lensed $\Lambda$CDM $B$-modes and a combination of Galactic and extragalactic foregrounds. This work characterizes foregrounds in the vicinity of the BICEP/Keck survey area, finding foreground power consistent with that reported by the BICEP/Keck collaboration within the same region, and a factor of $\sim$ 3 higher power over the full SPT-3G survey area. Using SPT-3G data over the BICEP/Keck survey area, we place a 95% upper limit on the tensor-to-scalar ratio of $r < 0.25$ and find the statistical uncertainty on $r$ to be $\sigma(r) = 0.067$.

Zebrowski, J. A. [Chicago U., KICP; Chicago U., As↗

Power control system modification and simulation of CPR1000 - 181

Due to development of electric power system, the proportion of nuclear power and its needs for load follow operation have become large. Then there would be higher requirements to the power control ability of the nuclear power system. The axial power distribution may change a lot in the operation process and be affected by many factors. In particular, as the power change is performed within a load follow maneuver, several modifications occur in the core from a neutronic view point: the fuel and moderator temperature change, the xenon concentration and distribution are modified, the power distribution skewed axially, etc. These changes need to be adequately counterbalanced to keep both the core critical and the power distribution acceptable. The traditional approach in pressurized water reactors (PWRs) is compensating for the reactivity change due to the power variation by adjusting the soluble boron concentration and moving a limited number of control banks. However, dilution/boronation strategy becomes expensive for short time changes and leads to large volume of liquid effluent, so it is eager about a capability to perform load follow operation without changing soluble boron concentration. CPR1000, one of the main reactor types in China national development, is taken an example in this paper. It adopts a control method called Mode G, using G banks, N banks, R bank and soluble boron to perform the load follow control. According to the analysis of the physics and thermal principle, a two-node dynamic function model was built, putting the coupling coefficient and mutual influence into consideration. By the calculation of these transient parameter values which are acquired by the steady-state calculation of single channel, the core system model of CPR1000 is established. In order to carry out the load follow operation without the boron adjustment, named as BTP mode, the control banks were regrouped to control the average temperature by M banks and axial offset by AO bank. After that, the average temperature control system (M banks control system) and the axial offset control system (AO bank control system) are built. When the optimal control system is connected to the core model simulation platform, the BTP mode load follow operation of the modified CPR1000 is simulated in the end of the paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗